| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion & making good disturbed ground embedded in Concrete, brick work, masonry, etc. Complete all as specified and directed. |
| 2 | M&L providing cement concrete type C1 1:3:6 (using 20mm graded aggregate) as in bed blocks, bed plates etc including necessary formwork all as specified and directed. |
| 3 | M&L for Plain cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate ) in foundations, filling and mass concrete all as specified and directed. |
| 4 | S&F Mild steel Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled & countersunk for balusters running bars, for doors,balusters,nosing to steps including embeding in concrete & screwing etc. wind ties for roof including securing bolts; posts & struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., & similar work conforming to Fe 290-0 Gde E-165. Complete all as specified and directed. |
| 5 | M&L for preapration of new steel or iron surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint one coat of red oxide, zinc chrome paint complete all as specified and directed. |
| 6 | S&F in repair Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings & straining & fixing to any type of standard rails straining bolts, including, securing or tying at crossings with & provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured). Complete all as specified and directed. |
| 7 | Restraining resecuring including making good galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings & straining & fixing to any type of standard rails straining bolts, including, securing or tying at crossings with & provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured). Complete all as specified and directed. |
| 8 | Dismantling fencing wire mesh, any type. Complete all as specified and directed. |
| 9 | Supply only Chain link MS galvanisd fencing, any size or type fixed to post struts or steel members complete all as directed. |
| 10 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire all as specified and directed. |
| 11 | S&F for mild steel screw bolts (machine cut) with hexagonal or square heads at one end and srewed the other or screwed both ends each screwed end to be fitted wth washers and one hexagonal or square not exceeding 5 cm long and diameter of neck 5 to 10mm complete all as specified and directed. |
| 12 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 13 | S&F mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed. |
| 14 | Dismantling of collapsible/rolling any type and size. |
| 15 | S&F of Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed. |
| 16 | S&F 1.25mm thick steel rolling shutters, with/without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position gear operated type with bevel gear box and crank handle including necessary scaffolding, safety measure as indicated, complete all as specified and directed. |
| 17 | Demolition of Brick/precast concrete block/Stone/boulder masonry walling built in cement mortar all as specified and directed. |
| 18 | M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonry exc 10cm in width with solid block masonry and setting in cement mortar 1:6 all as Specified and directed. |
| 19 | M&L Cement concrete type C-2 1:3:6 (using 40mm graded stone aggregate) as in surface channels and drains all as Specified and directed. |
| 20 | Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key, scrubbing down with water etc complete all as specified and as directed |
| 21 | M&L for 15 mm thick rendering on brick work/block masonary surface finished even and fair without using extra cement in cement mortar 1: 4 complete all as specified and as directed |
| 22 | M&L for preperation of new plastered wall surface of any description and applying two coat of cement based paint complete all as specified and as directed. |
| 23 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and as directed. |
| 24 | M&L 100mm thick Plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in hardstanding/path including use and waste of formwork/ screed strip and to divide the area in panels complete all as specified and as directed. |
| 25 | M&L 75 mm thick Cement concrete type D- 2, 1:4:8 (using 40mm graded aggregate) as in sub-base all as specified and as directed. |
| 26 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed |
| 27 | M&L coloured chequered cement concrete tiles 30cm x 30cm x 20-25mm thick, set, jointed and pointed in neat cement slurry in floors with grey pigment cement and pigment including over 15mm thick screed bed in CM 1:4 complete all as specified and as directed |
| 28 | M&L Plain Cement Concrete type B-1 1:2:4 (using 20mm graded stone aggregate) as in coping all as specified and as directed |
| 29 | Removing demolished building materials etc. to a distance of exc 1.00 KM including loading and disposing off from out side of the MoD land by the contractor on own arrangement (1 load= 3Cum). |
| 30 | M&L for preperation of old plastered wall surface of any description and applying one coat of cement based paint. Complete all as specified and as directed. |
| 31 | S&F in repair punched tape concertina coil of 600mm/900mm/1050 mm dia , 56 loops, 2.5 mm core wire, heavy galvanised (wire-275 GSM), tensile strength of wire 1450- 1500 N/Sqmm, (weight 15.20 Kg/Coil +/- 5%), stretchable length 15 m including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as required in isolated patches complete all as directed. |
| 32 | S & F Rotational moulded polyethylene water storage tanks of 500 ltrs capacity (cylin-drical vertical with closed top) hoisted and fixed in position including dismantling water tanks of any type of capacity exc 250 but n.exc 500 liters and including S & F of Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed to 20 mm bore pipe complete all as specified and directed. |
| 33 | M&L 100mm thick Cement concrete type D- 2, 1:4:8 (using 40mm graded aggregate) as in sub-base all as specified and directed. Please Enable Macros to View BoQ information |