| 1 | Providing and fixing of panels for wall and roof. The roof shall be provided 50 mm thick puff insulated panel make Sintex or Equivalent 0.50 m thick precoated precoloured sheets. The roof sheet are laid over a frame work of trusses and purlins and rafters fixed using suitable fasteners. A 0.50 mm precoated/ precoloured steel sheets ridge cover of 0.40 mm from the eyes wall and 0.30 mm from the gable wall. The wall shall be made in sandwich panel system using 2 No's of precoated precoloured sheets of 0.50 mm thick fitted fitted with 75 mm thick puff with bulk density of 40 kg/cum. The puff panels shall be make Sintex/Llyod/Jindal or equivalent continuous panel system. The panels shall be inserted one by one in \\"U\\" shaped ground track of size 52.5x35x1.25 mm thick made from G.I sheet/sheet coil. The bottom track shall be fixed to the concrete platform level by suitable fasteners screwed on the PVC expandable screw cap. The top of the walls would be concealed with \\"U\\" shaped top track of size52.5x35x1.25 mm thick made from G.I sheet/sheet coil. The roof shall be 1:4 approximately as per seismic Zone -IV . The walls height shall be 3 Mts at eyes and 3.36 Mts at centre gable. |
| 2 | Structural steel work rivted and bolted in built up section trusses/tubular section and frame work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as per directions of EIC |
| 3 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up heavy standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e. at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 4 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades,in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. Size of tile 600x600 mm along with scredding below it. |
| 5 | Providing and fixing tiled False Ceiling of specified materials 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard manufactured from natural gypsum as per IS 2095 Part-1 and laminated with white 0.16 mm thickof interlocking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms/sqm both side inclusive ) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200 x 600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using OI slotted cleats of size 27x37x25x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.8 mm spaced at 1200 mm center to center along size 85x30x0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 6 | Including necessary electrification and allied works including 1 no. ceiling fan (56 inch sweep) of (Brand - Havells, Crompton or equivalent) as per the directions of EIC(Complete Job) Control room with Pantry & wash Room |
| 7 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 8 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 9 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 10 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 11 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Cold twisted bars |
| 15 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid |
| 16 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : 18.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. (CERA/ HINDWARE) |
| 17 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 18 | Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS : 8931 |
| 19 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. |
| 20 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms |
| 21 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm |
| 22 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 23 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing |
| 24 | 15mm nominal outer dia pipes |
| 25 | 25mm nominal outer dia pipes |
| 26 | 32mm nominal outer dia pipes. |
| 27 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes |
| 28 | 75 mm diametre |
| 29 | 110 mm diametre |
| 30 | Providing and Fixing 500 Litre PVC Water Tank including Allied Works of ISI Mark (Vectus, Supreme or equivalent) |
| 31 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 470x420mm bowl depth 178mm |
| 32 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 33 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete:Semi rigid pipe 32 mm dia |
| 34 | Providing and fixing 100 mm sand cast iron grating for gully trap. |
| 35 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 36 | Providing and laying river bed material in plinth by way of spreading the same in uniform layers not exceeding 20cm in depth, watering and compacting with woden/ steel rammers including carriage of material from source to site of work (all lead lift complete job) |
| 37 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 38 | Supply of Brick Bats |
| 39 | Supply of Brick Aggregate (Single size) 20 mm nominal size |
| 40 | 12mm Cement plaster finished with a floating coat of neat cement of mix: 1:3 ( 1 cement : 3 fine sand) |
| 41 | Supply and Installation of inverter with battery exide/Luminous/microtek brand with battery 150 AH complete fitting and wiring |
| 42 | Supply of 1 no. Wooden Bed (size 4'x 6'), 1 No. Table & 4 chairs of (Brand - Neelkamal / Supreme or equivalent) |
| 43 | Supply and Installation of Air Cooler (Brand Symphony or equivalent) |
| 44 | Carriage of material from source to site of work including loading, unloading complete |
| 45 | Sand average distance 10 km by MT |
| 46 | Stone aggregiate average distance 10 km by MT |
| 47 | Bricks average distance 20 km by MT Please Enable Macros to View BoQ information |