| Sl. No. | Item Description |
| 1 | BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER, UDHAMPUR Name of Work: REPAIR/ MAINTENANCE HT ELECTRIC SUPPLY SYSTEM AT WATER SUPPLY INSTALLATIONS UNDER GE (UTILITIES) UDHAMPUR Contract No: CWE/U(U)-42/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolation of concrete excavation and earth work as reqd and removing the same from Site complete all as specified and as directed. |
| 3 | Dismantling of old U/S GOD 11 KV and DO fuse unit unit of any type and capacity complete all as specified and directed. |
| 4 | Dismantling of old UNSVdamage/rusted PCC pole/steel tubular poles of any Size necessary disconnecting cables/over head condcutor and removing unserviceable pole from Site complete all as specified and directed. |
| 5 | Dismantling of insulator of any type and Size from existing poles after opening nuts, bolts and removing from Site all as directed. |
| 6 | Dismantling of existing UNSV HT lightning arrestor form the electric pole and removing from Site complete all as directed. |
| 7 | Dismantling HT Danger notice plate from existing postion and removing from Site complete. |
| 8 | Supply and fix HT 11 KV, 150 mm height and 150 mm dia pin type insulator, porcelain, vitreous, white/brown/green, conforming to IS-2486 for 11000 Volts grade including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut complete all as specified and directed. |
| 9 | Supply and fix disc type insulator, porcelain, vitreous, 145mm high and 255mm dia ball and socket type, white, brown or green, Single disc assembly for working pressure 11000 Volts, conforming to IS-731 and IS-3188 including tenSSRon clamp complete all as specified and directed. |
| 10 | Supply and laying Galvanised steel wire 4.00 mm dia as continuous earth wire on over head conductor, Guard cradles on road crossing and stretching the same with required span, sag and binding the conductor with GI binding wire of approximate Size all complete all as specified and directed. |
| 11 | Supply and erection of steel tubular swaged pole 11.00 metres long designation 410-SP-55 complete with cast iron base plate, finial taper plug, bolts, nuts and screws etc. complete all as specified and directed. [Note :- Earth work and concrete foundation shall be measured and paid seperately under relevant items of Sch 'A'). |
| 12 | Excavation in trenches not exc. 1.5 metre wide and not exc. 1.50 mtr depth for laying of underground cable, erection of poles etc. and getting out in hard/loose soil including separating serviceable bricks for re-use at Site obtained during excavation complete all as specified and directed. |
| 13 | All as per item No 12 here-in-before but exc. 1.50 metre depth and not exc. 3.00 metre deep. |
| 14 | Returning, filling in, including, spreading, leveling, watering and well ramming in layers n.exc. 25 cm in soils complete all as specified. |
| 15 | Removing excavated soil n. exc 50 m and depositing where directed at a level n.exc. 1.5 mtr above the starting point completed all as specified. |
| 16 | M&L PCC 1:4:8 type C-2 (using 40mm graded stone aggregate) as in foundation of pole etc. complete. |
| 17 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate ) as in coping/stay including necessary form work complete for pole etc. |
| 18 | S&F double walled corrugated (DWC) pipe of size 120/103mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete all as specified and directed. Make: REX/Tirupati Plastomatics Pvt Ltd |
| 19 | S&F double walled corrugated (DWC) pipe of size 180/152 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete all as specified and directed. Make: REX/Tirupati Plastomatics Pvt Ltd |
| 20 | Taking up/down under ground cable 11000 Volt grade of Size 95 Sqmm to 185 Sqmm Sqmm, 03 core from trenches, ducts, floor, pipes and removing materials from Site of work complete all as directed by Engineer-in-Charge.(Note: Excavation and earth work shall be measured separately) |
| 21 | Supply, laying, connecting and testing XLPE insulated ,Earthed cable in trenches/or fixed on pole etc in screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 Volt grade, cross sectional area 95 Sqmm, 3 Core Conforming to IS-7098 (Part-II)-1985 complete all as specified and directed.(Note: Excavation & earth work shall be measured and paid separately) |
| 22 | Supply, laying, connecting and testing XLPE insulated ,Earthed cable in trenches/or fixed on pole etc in screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 11000 Volt grade, cross sectional area 120 Sqmm, 3 Core Conforming to IS-7098 (Part-II)-1985 complete all as specified and directed.(Note: Excavation & earth work shall be measured and paid separately) |
| 23 | M&L for Premix ready mix road repair patching compound for instant road repair manufactured with a blend of bitumen, aggregates and high grade polymer to ensure immediate bonding with existing surface available in bag of 25 Kg Complete all as specified and as directed. |
| 24 | Supplying, laying, testing and connecting in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable of size 120 sqmm 3 core (heavy duty) with multistranded aluminum conductors,33 KV grade,IS 7098 (Part-2) 2011 marked, suitable for HT 33 KV(E) system, laid in trenches / ducts / encased in GI, HDPE pipe / fixed to pole etc or against re-routing / diversion from residential buildings/ road/ footpath etc, including jointing & testing complete all as specified and directed by Engr In Charge. |
| 25 | Supplying, laying, testing and connecting in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable of size 185 sqmm 3 core (heavy duty) with multistranded aluminum conductors, 11 KV grade,IS 7098 (Part-2) 2011 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI, HDPE pipe / fixed to pole etc or against re-routing / diversion from residential buildings/ road/ footpath etc, including jointing & testing complete all as specified and directed by Engr In Charge. |
| 26 | M&L for cutting/boring the existing bitumen us road/payment/footpath upto 0.75 mtr in depth, 0.45 mtr in width and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road all as directed by Engr-in-Charge. Note :-(i) M&L for laying of pipe shall be measured and paid separately. |
| 27 | Supply, fixing and testing heat shrinkable type end termination cable jointing kit, outdoor type suitable for XLPE insulated cable, 120 to 185 Sqmm Size 3 core, 11 KV, as fixed in repairs complete all as specified and directed. |
| 28 | Supply, fixing and testing heat shrinkable type end termination cable jointing kit, outdoor type suitable for XLPE insulated cable, 50 to 95 Sqmm Size 3 core, 11 KV, as fixed in repairs complete all as specified and directed. |
| 29 | Supply, fixing and testing heat shrinkable type end termination cable jointing kit, indoor type suitable for XLPE insulated cable, 120 to 185 Sqmm Size 3 core, 11 KV, as fixed in repairs complete all as specified and directed. |
| 30 | Supply, fixing and testing heat shrinkable type end termination cable jointing kit, indoor type suitable for XLPE insulated cable, 50 to 95 Sqmm Size 3 core, 11 KV, as fixed in repairs complete all as specified and directed. |
| 31 | Supply, fixing and testing heat shrinkable type, straight through cable jointing kit, outdoor type suitable for XLPE insulated cable, upto 120 to 185 Sqmm Size 3 core, 11 KV, as fixed in repairs complete all as specified and directed. |
| 32 | Supply, fixing and testing heat shrinkable type end termination cable jointing kit, outdoor type suitable for XLPE insulated cable, 120 Sqmm Size 3 core, 33 KV, as fixed in repairs complete all as specified and directed. |
| 33 | Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz, with 12 insulator of rating upto 400 Amps including taking down existing GOD complete and removing from SSRte complete all as specified and as directed. |
| 34 | Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz, with 9 insulator of rating upto 200 Amps including taking down existing GOD complete and removing from SSRte complete all as specified and as directed. |
| 35 | S & F drop out fuse unit Single pole mounted on insulator, 11000 Volts grade double pole steel frame of current rating 50 Amps including taking down existing DO fuse unit complete and removing from Site complete all as specified and directed. |
| 36 | S & F Loop type insulator, vitreous porcelain, white or brown small Size with overall dimension 65mm x 90 mm and clearance of hole 16mm complete all as specified. |
| 37 | S & F HT lightning arrestor for out door use expulsion type complete with all fittings,65 Kilo amps discharge capacity, distribution class. |
| 38 | S & F HT 11000 volts Danger notice plate of Size 25cm x 20cm made of 1.6mm thick mild steel plate, vitreous enamelled white, with letters, figures and conventional skull and bones in Signal red colour and fixed with MS clamps, bolts and nuts of approved Size complete all as specified and directed. |
| 39 | Earthing complete with copper earth plate electrode 60 cm x 60cmx 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to copper strips 20x3 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion |
| 40 | Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron strips 32 x 6 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion |
| 41 | Supply and fix in repair Earth continuity conductor or main earthing lead fixed to wal on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of 25x4 mm galvanised iron strip. |
| 42 | Supply and fix in repair Earth continuity conductor or main earthing lead fixed to wal on batten or recess or chasses or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation of earthing lead of 4 mm dia galvanised. |
| 43 | S&F Stay assembly complete with all accessories with stay clamps as shown in electrical plate No 1 of SSR Part-I with using stay rod 16mm dia all complete as specified and directed.[Note :- Loop type insulator, excavation and concrete foundation shall be measured and paid separately under relevant items of Sch 'A'] |
| 44 | M & L for galvanised stay stand in repair of, Size 7/4 mm complete all as specified and directed. |
| 45 | Dismantling of cross arms fixed on steel tubular poles carefully and removing from Site complete all as specified and directed. |
| 46 | Supply and fixing cross arms of mild steel channel or angle sections of any Size and shape including clamps, back plate with bolts, nuts, washers drilled for insulator bolt, welding, bending cold or hot in any shape or Size as directed and painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. |
| 47 | Dismantling of overhead ACSR (Aluminium conductor steel reinforced) from existing electric pole and removing unserviceable ACSR from Site complete all as directed. |
| 48 | M&L for Aluminium conductor steel reinforced (ACSR) on overhead electric lines and stretching the same with required span sag and binding the conductor with pin/shackle insulator and jumpers with aluminium binding wire not less than 2.00 mm dia complete all as specified and directed for any Size. |
| 49 | S & F GI tubing 80mm dia light grade in protection of cable of different dia laid in trench under road/foot path or fixed on pole with necessary clamps with bolts etc all as directed. |
| 50 | Preparing surfaces of steel tubular swaged pole 11 Mtr long with scraping out old paint by emmery paper, castic soda complete and painting with two coats of aluminium paint over a red oxide primer and writing the No of poles and feeder name complete all as specified and directed by Engr-in-Charge and stripping with black paint & yellow paint (300 mm each stripe) 5 Nos at equal distance from bottom (above PCC coping) upto a height of 1500 mm complete all as specified and as directed. |
| 51 | S & F HT UG cable PCC route marker of Size 900mmx80x50mm dully written HT UG Cable, GE (U) UDHAMPUR with red strip marking of suitable Size inclued embeded in earth with necessary PCC works 40cmx40cmx40cm complete all as specified and directed by Engr-in-Charge. |
| 52 | Re-adjustment, cleaning of contact, greasing and testing of out door type air break switch 11 KV current rating upto 200 Amps including all materials required for alignment for AB/GO 11 KV switch in posting and replacement of unserviceable parts connections with and including lugs, GI nuts, bolts etc complete all as directed. (Note :- Replacement of unserviceable parts shall be measured and paid separately under relevant items). |
| 53 | Brass terminal plate for mounting male contact of AB/GO 11 KV 200 Amp switch insulator in replacement of old unserviceable plate including GI nuts and bolts washers etc as required complete. |
| 54 | Male contact for AB/GO 11 KV 200 Amp switch in replacement of unserviceable old male contact complete all as specified and directed. |
| 55 | Female contact for AB/GO 11 KV 200 Amp switch in replacement of unserviceable old male contact complete all as specified and directed. |
| 56 | M&L in replacement Post insulator for AB switch with metal part Suitable for HT 11 KV conforming to IS 5572-1972 complete all as specified and directed. |
| 57 | Dismanting and taking down carefully existing UNSV air breather from out door/in door type step down power transformer of any capacity complete all as specified and directed. |
| 58 | Supply and fix air breather complete with Silica gel suitable for out door type step down power transformer up to 63 KVA to 200 KVA complete all as specified and directed. |
| 59 | Supply and fix air breather complete with Silica gel suitable for out door type step down power transformer up to 320 KVA to 1000 KVA complete all as specified and directed. |
| 60 | Disconnecting HT/LT Side electrical connection carefully existing 11 KV/415 Volt step down transformer of any capacity, draining out and refilling of existing transformer oil after filteration dehydration and measuring the dielectric strength which should not less than 50 KV including reinstallation of transformer satisfactory on its original position connecting testing and commissioning complete including all lighting arrangement with cable and other items for dehydration machine all as directed by Engr-in-Charge. |
| 61 | Supply only transformer oil of approved quality (Dielectric strength not less than 40 KV) ISI marked for filling in transformer for topping up all as directed by Engr-in-Charge |
| 62 | Disconnecting of all electric connection of defective distribution transformer 11/0.433 KV outdoor /indoor type , Opening top cover of transformer , taking out insulating oil upto lower level of bushing and keeping in clean & dry container (oil to be reused) for replacement of LT Bushing , gaskets etc incuding refixing the same and refilling the drained out transformer oil complete, reconnection etc complete all as specified and directed :- Note :- Spare part and repair will be measured and paid for separately. |
| 63 | Supply and fix in repair HT bushing suitable for out door type 100/200/320/1000 KVA transformers confirming to IS-334 complete with nut bolts brass studs and gasket of synthetic rubber bonded cork sheet all as specified and directed by Engr-in-Charge. |
| 64 | Replacement of ceramic bushing and Gasket on HT side of transformers of capacities 63 to 1000 KVA capacities complete all as specified and directed. |
| 65 | Replacement of ceramic bushing and Gasket on LT side of transformers of capacities 63 to 1000 KVA capacities complete all as specified and directed. |
| 66 | Supply and fix in repair LT bushing 1100 volt grade complete with nut bolts, brass studs, insulator and gasket etc suitable for out door transformer complete all as specified and directed. |
| 67 | Replacement of ceramic bushing and Gasket on HT side of transformers of capacities 3.15 MVA capacities complete all as specified and directed. |
| 68 | Replacement of ceramic bushing and Gasket on LT side of transformers of capacities 3.15 MVA capacities complete all as specified and directed. |
| 69 | Supply and fix in repair LT bushing 3.15 MVA grade complete with nut bolts, brass studs, insulator and gasket etc suitable for out door transformer complete all as specified and directed. |
| 70 | Supply and fix in repair HT bushing 3.15 MVA grade complete with nut bolts, brass studs, insulator and gasket etc suitable for out door transformer complete all as specified and directed. |
| 71 | M&L for replacement of Off load tap changer of Transformer Rating from 315 KVA to 1000 KVA as per the existing make of transformer complete all as specified and directed. |
| 72 | M&L for painting of transformer after cleaning the body surface of transformer 100 KVA to 200 KVA by rubbing with emery Ppper to remove oil stains, dust etc and applying two coat of snthetic enamel paint by spray paint incl writing SM No/MES No , capacity of transformers of following capacity all as directed by Engr-in-Charge. The contractor has to arrange their own local generator for supply to the spray painting machine. |
| 73 | M&L for painting of transformer after cleaning the body surface of transformer 320 KVA to 1000 KVA by rubbing with emery Ppper to remove oil stains, dust etc and applying two coat of snthetic enamel paint by spray paint incl writing SM No/MES No , capacity of transformers of following capacity all as directed by Engr-in-Charge. The contractor has to arrange their own local generator for supply to the spray painting machine. |
| 74 | Replacement of arc horn surge arrester complete with amounting ring, nut bolt etc of approved make suitable for transformers of capacity from 100KVA to 1000 KVA. |
| 75 | M&L for rewinding of HT/LT coils of transformer of capacity 63 KVA to 1000 KVA with super enamelled copper winding wire of existing gauge and proper number of turns alongwith insulating material i.e leatheroid, paper insulation, cotton tapes, empire tapes, wooden block packings, PVC sleeves, soldering and varnishing with insulating varnish , heating/drying etc complete all as specified and directed. |
| 76 | Taking down/dismantling and refixing of transformer upto 1000 KVA by using Hydra mechine complete and including tranportation shifting to approved manufacturer/Workshop including testing and commissioning all as directed. |
| 77 | Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 11KV grade stranded and compact aluminium phase conductor of size 3x120 sqmm + 1x70 sqmm (bare messenger) with Aluminium alloy as per IS-8130-1984 ans ISD 398(Part-4)-1979. The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14255-1995 & IS-7098(Part-2)-1985 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed. |
| 78 | Caliberation of VCB 11 KV and 33 KV of Micro processor based numerical relay/IDMT Relay by conducting primary injection on rescpective CTs and secondary injection tests on relays,checking of current transformer including CTR Ratio, IR Value, CT Secondary Resistance Measurement Test, rectifiation of defects in control wiring for proper tripping of circuit breakers through CTs, relays and tripping coils,adjustment/setting of the relay to restrict fault to upstream breakers,re-installation of the relay in circuit complete all as specified and as directed.NOTE:- (a) The contractor shall provide necessary testing kits, testisng equipments,tools etc and shall also prepare the detailed test reports panel wise duly bound and submit to the department. Rate for the kits and equipment is deemed to be included in rate quoted. Testing and turning shall be carried out in the presence of Engineer-in-Charge to the satisfaction of department, failing which payment for the above item will not be made to the contractor. No claim from the contractor be enterained on this account.(b) Rate is inclusive of setting the parameters in differential relay and connecting after carrying out necessary polarity tests etc |
| 79 | Cont.. serial item no 77(c) This item includes all routine test of VCB for proper tripping in case of fault and tripping time should be set lesser than GE (U) Tawi filter and Jackwell 11 KV Grid end so as to fault will not feed back to GE (U) 33 KV Tawi power house . The contractor has to collect the data of tripping time from GE (U) Tawi filter and Jackwell 11 KV Grid and tripping time should be set lesser timing in our end. All control wiring of VCB should be cleaned and serviced and change the unserviceable part as per directed by Engr-in-Charge. The u/s item will be paid sepeartely. (d) Contractor will take the prior permission for shutdown of HT Line in written at least one week in advance for getting permission from user by MES to avoid any administration issue.Note- The test should by done be authorised dealer of VCB/OEM. |
| 80 | Taking down the HT vacuum circuit breaker indoor/outdoor of capacity up to 200Amp to 400 Amp, of any make, 11 KV, through authorised VCB rep/OEM for servicing and re-assembling complete, comprising of the following including testing and commissioning to the entire satisfaction of Engineer-in-Charge. Note: Quoted rate is inclusive for the following services:-(i)Taking out the VCB from the enclosure & checking the serviceability of the following parts carefully including cleaning, adjustments and re-assembling the unit complete.(ii) Cleaning the external surface of bushings with CTC/CRC or Liquid ammonia to remove the accumulation of dirt or any other deposits. Inspection of bushings and make sure that vibration due to breaker operation have not caused the bushings to move resulting misallignment of contacts.(iii) Checking the breaker bushing of bus bar and circuit side inspecting the interval surface carefully for any charging/trackings,replacement of bushings.(iv) Dismantling the spring charging mechanism of the VCB, checking the operations of the closing/tripping trough closing/tripping coils electrically as well as manual charging including cleaning adjustments complete for the following. |
| 81 | Cont.. serial item no 78(v) Checking the condition of the spring charging motor along with gear box including servicing to the motor commulator bushes, lubrication of bearing surfaces etc.(vi) Cost of additional hardware like, bolts, nuts , washers and spring washers, petrolium jelly ctc, to put the breaker in serviceable condition is deemed to be included in the rates quoted. (vii) Making functional by carrying out minor repairs all the non functional circuits and indicating system like VCB Trip, CB ON, CB OFF, CB Service, Spring Charging etc(viii) Test shall include IR, CRM and time Test.(ix) Contractor will take the prior permission for shutdown of HT Line in written at least one week in advance for getting permission from user by MES to avoid any administration issue. Note : The u/s item will by paid sepeartely. Note- The test should be done be authorised dealer of SF6. |
| 82 | Maintenance and complete overhauling of 33 KV outdoor VCB 1250 Amp breaking capacity-26.3 kA operating duty: 0-0.3Sec-CO-3Min-COMake: Crompton including disassembling of operating mechanism parts, well cleaning with petrol & CRC-226 and reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonizing all joints bus bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete and replacing unserviceable parts and components etc complete all as specified and directed by Engr-in-Charge.Note: (i) Spare parts will be measured and paid separately as under relevant items as supply only. The labour charges for fixing shall be included in this item. |
| 83 | Close shaft assembly of existing specifications and make with spring and close strips indoor type 33 KV VCB in replacement, complete all as specified and directed. |
| 84 | TNC switch/(Tripping neutral & closing) of existing specifications and make with coil suitable for 33 KV VCB 1250 Amps in replacement, complete all as specified and directed. |
| 85 | Over current/Earth fault relay Numerical 3 Pole, OC/EF Protection Relay ,Model:- ADR 131A, suitable for 33 KV VCB in replacement, complete all as specified and directed by Engr-in-Charge. |
| 86 | Replacement of IDMT relay suitable for VCB 33 KV complete with necessary electricial connection complete all as specified and directed. |
| 87 | Replacement of Master Trip Relay, 1 Element 4NO+3NC, voltage-24-30VDC suitable for 33 KV VCB as per existing make and model complete with necessary electricial connection as directed. |
| 88 | Replacement of Trip supervisory relay , Auxilary voltage-24-30VDC suitable for 33 KV VCB as per existing make and model complete with necessary electricial connection as directed. |
| 89 | S&F in repair HRC fuse link type NSD 20 Amp, 500V ISI marked type -uitable for 33 KV VCB in replacement, complete all as specified and directed. |
| 90 | Replacement of Motor charged mechanasim assembly and charging handle suitable for VCB 11 KV, with all mechanical connection complete as per existing make and model complete with necessary electricial connection as directed. |
| 91 | Alarm annunciator relay, suitable for 20-60VAC/DC for 33 KV VCB complete with necessary electricial connection complete all as specified and directed. |
| 92 | Push Button Bracket assembly of existing specifications and make suitable for 33 KV VCB in replacement, complete all as specified and directed. |
| 93 | Charged/Discharged indicator assembly of existing specifications and make suitable for 33 KV VCB in replacement, complete all as specified and directed. |
| 94 | Triping spring assembly of existing specifications and make suitable for 33 KV VCB in replacement, complete all as specified and directed. |
| 95 | Trip shaft assembly of existing specifications and make with spring and trip strips suitable for 33 KV VCB in replacement, complete all as specified and directed. |
| 96 | Dismantling/Disconnecting the UNSV CT PT from the site supply and fix new outdoor three phase 33 kv CT PT. CT Ratio-100/.5A, and Pt Ratio 33KV/110V,Class-0.5 Combined metering unit 33 KV of same size and capacity of existing, complete all as specified and as directed. |
| 97 | Supplying, installation, commissioning and testing in replacement of 33 KV Current Transformer (CT`s), outdoor oil cooled type, HSV-36 Kv,STC-25KA for 1 secRatio 250-125/5-5-2.89 A, single phase accuracy-0.2as per IS-2705 including associated wiring complete all as specified and directed. |
| 98 | Push Button Bracket assembly of existing specifications and make suitable for 11 KV VCB in replacement, complete all as specified and directed. |
| 99 | Replacement of IDMT relay suitable for VCB 11 KV complete with necessary electricial connection complete all as specified and directed. |
| 100 | Replacement of Master Trip Relay, 1 Element suitable for 11 KV VCB as per existing make and model complete with necessary electricial connection as directed. |
| 101 | Replacement of Auxiliary Relay, 3 Element suitable for 11 KV VCB as per existing make and model complete with necessary electricial connection as directed. |
| 102 | Replacement of common 8 window microprocessor based alarm annunciator suitable for 33/11 KV VCB as per existing make and model complete with necessary electricial connection as directed. |
| 103 | Replacement of AC/DC fail Relay, suitable for 11 KV VCB complete as per existing make and model complete with necessary electricial connection as directed. |
| 104 | Supplying, installation, commissioning and testing in replacement of 11 KV Current Transformer (CT`s), indoor type, epoxy cast resin having ratio 200/100/5-5 Amps, core -1, Class 5 P10, 15 VA for protection, Core 2 Class 0.5 , 15 VA for metering, Short circuit time rating 13.4 kA for 3 Sec including associated wiring complete all as specified and directed. |
| 105 | Supplying, installation, commissioning and testing in replacement of PT unit three phase, three limbs, upto 11 KV draw-out type,Il 35/75KV, HSV-12kV, single ratio having primary voltage 11 KV & secondary voltage 110 volts, 50 VA class-0.5 , VF: 1.2including necessary bus bar connections & wiring for metering complete all as specified and directed . |
| 106 | Supply & Fixing in replacement of Digital Amp meter (CT secondary site selectable 5A), Cl-1 for 11 KV VCB Control Panel as per existing make and model complete with necessary electricial connection as directed. |
| 107 | Supply & Fixing in replacement of Digital Volt meter, Cl-1, Secondary voltage 110 V for 11 KV VCB Control Panel as per existing make and model complete with necessary electricial connection as directed. |
| 108 | Replacement of TNC switch, suitable for 11 KV VCB as per existing make and model complete with necessary electricial connection as directed. |
| 109 | Replacement of local remote switch, suitable for 11 KV VCB complete as per existing make and model complete with necessary electricial connection as directed. |
| 110 | Replacement of Spring Charging motor suitable for 11 KV VCB complete as per existing make and model complete with necessary electricial connection as directed. |
| 111 | Replacement of Big Gear, Small Gear and & Half Gear Set assembly suitable for VCB 11 KV complete as per existing make and model complete with necessary electricial connection as directed. |
| 112 | Replacement of Spring Charging motor asembly suitable for 11 KV VCB complete as per existing make and model complete with necessary electricial connection as directed. |
| 113 | S & F in replacement of LED indication lamp ( different colour) 24/110 Volts for breaker ON/OFF /TRIP/ Breaker Spring Charged/R-Y-B etc for 11 KV control panel/ 33 KV Control Panel including associated wiring, if reqd, complete all as specified and directed. |
| 114 | Replacement of Push Button suitable for 11 KV VCB complete as per existing make and model complete with necessary electricial connection as directed. |
| 115 | Replacement of Vaccum Interrupter suitable for 11 KV VCB complete with necessary electricial and mechanical connection as per existing make and model complete with necessary electricial connection as directed. |
| 116 | Replacement of Housing for Vaccum Interrupter suitable for 11 KV VCB complete with necessary electricial and mechanical connection as per existing make and model complete all as directed. |
| 117 | Replacement of Hooter suitable for 11 KV VCB complete with necessary electricial and mechanical connection as per existing make and model complete all as directed. |
| 118 | Replacement of multifunction meter suitable for 11 KV VCB complete with necessary electricial and mechanical connection as per existing make and model complete all as directed. |
| 119 | Replacement of Auxiliary switch suitable for 11 KV VCB complete with necessary electricial and mechanical connection as per existing make and model complete all as directed. |
| 120 | Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as directed. |
| 121 | Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 33 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as directed. |
| 122 | Supply and spread stone aggregate of size 20 mm in sub-stations/electric yards including levelling complete all as specified. Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail