| 1 | 'Notes: (i) Please refer Schedule 'A' Notes of tender documents. |
| 2 | M&L for removing all connections, bindings etc of ACSR/AAC conductor on existing LT poles & stretching of ACSR/AAC conductor upto required sag of any size and cross section of conductor and stretching of GI wire on existing pole including making necessary connection & binding with binding wire including cutting of tree branches from both sides upto the stress on each side complete all as specified and as directed. |
| 3 | Taking down unsv pin type insulator and providing new pin type, porcelain vitreous white brown or green insulator including one galvanized mild steel spindles, two galvanized iron washers and one galvanized iron nut 100mm height, 65 mm dia for 1100 Volt grade complete all as specified and as directed. |
| 4 | M&L for replacement of shackle type porcelain, vitreous white brown or insulator working under 1100 volts grade , pressure of height 75 mm & 90mm dia insulators, dia of bolt 12mm , section of straps 31 x 3mm, washers, nuts complete all as specified & directed. |
| 5 | Taking down U/S stay assy and M&L for stay assy comprising of MS stay plate of size 23cmx23cmx6mm thick, stay rod with nuts 215cm ling 16mm dia , MS/GI stay bow 40cm lingh with 2 Nos GI thimbles, galvanized stay wire standard size 7/4mm of suitable length, loop insulation size 65x90mm clearance of hole 16mm & other accessories including excavation earth work & PCC work complete all as per SSR Pt-1 plate No-1 complete all as specified and as directed.Note : MS clamps will be measured & paid separately in respected items. |
| 6 | M&L for cleaning away all grass, vegetation, saplings, shrubs, undergrowth, roots and trees up to 50 cm girth from the area surrounding of E/M installations, under HT< over head lines, 4/2 pole structures, transforemer, installations, yards, surrounding valve chamers and removing the rubbish upto a distance 50 mtr outside the periphery of the area under clearance and dressing the area etc complete all as specified and directedNote : Photographic evidence (before and after) of the area to be deemed be produced before claiming payment. Please note otherwise no payment shall be made for the same. |
| 7 | Taking down rusted/unsv mild steel work and M&L for mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot , drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. |
| 8 | M&L in replacement of cradles, hexagonal/ rectangular fabricated with galvanised steel wire of size 4mm dia complete all as specified and directed. |
| 9 | M&L in repalcement of existing any type or any size aluminium conductor, steel reinforced including binding wire and jumper connect with PG clamp made out of aluminium alloy accodring to IS-617 complete all as specified and directed. |
| 10 | Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of pipes and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and as directed. |
| 11 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed. |
| 12 | Removing surplus spoil to a distance not exceeding 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and directed. |
| 13 | Supply and laying sand river for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed.(Note: Thickness after punning shall be measured for payment ) |
| 14 | Supply and laying brick protection cable cover using sub class ‘B’ bricks laid flat adjacent to each other across the length of cable laid dry complete all as specified & directed. |
| 15 | Supply & Fixing in replacement of existing PCC/Steel pole with new steel tubular poles complete with cast M&L for iron base plate, final taper, plug, bolts, nuts & washers as specified type 410 SP-31 (9.0 mtr long) including re-fixing of removed accessoreis such as ACSR/AAC conductor, cables, street light fittings, clamps, nuts & bolts etc complete all as specified and directed.Note :- Excavation, MS work and PCC work will be measured and paid separately. |
| 16 | M&L for PCC work type D-2 (1:4:8) with 40mm graded aggregate for foundation to poles / stays/strutus or basements etc complete all as specified and directed. |
| 17 | M&L for PCC work type C-2 (1:3:6) with 40mm graded aggregate for foundation to poles / stays/strutus or basements etc complete all as specified and directed. |
| 18 | M & L for PCC work type B-1(1:2:4) with 20 mm graded aggregate for coping ( new and old damage coping) to poles / stays/strutus or basements etc complete all as specified and directed. |
| 19 | Taking down old rusted galvanized iron pipe and providing galvanized pipe 80 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. |
| 20 | Taking down old rusted galvanized iron pipe and providing galvanized pipe 40 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. |
| 21 | Taking down old rusted galvanized iron pipe and providing galvanized pipe 100mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc, complete all as specified and directed. |
| 22 | M&L for supply, laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 240 sqmm 3.5 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed.Note :-(i) Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately |
| 23 | All as per item No. 22 here-in before but cable of size 3.5 core 120 sqmm complete all as specified and directed. |
| 24 | All as per item No. 22 here-in before but cable of size 3.5 core 95 sqmm complete all as specified and directed. |
| 25 | All as per item No. 22 here-in before but cable of size 3.5 core 70 sqmm complete all as specified and directed. |
| 26 | All as per item No. 22 here-in before but cable of size 3.5 core 50 sqmm complete all as specified and directed. |
| 27 | All as per item No. 22 here-in before but cable of size 4 core 25 sqmm complete all as specified and directed. |
| 28 | All as per item No. 22 here-in before but cable of size 4 core 16 sqmm complete all as specified and directed. |
| 29 | All as per item No. 22 here-in before but cable of size 04 core 10 sqmm complete all as specified and directed. |
| 30 | All as per item No. 22 here-in before but cable of size 02 core 10 sqmm complete all as specified and directed. |
| 31 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 250 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. |
| 32 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 200 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. |
| 33 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 160 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. |
| 34 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 125 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 25 kA complete all as specified and directed. |
| 35 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range100 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz25 kA complete all as specified and directed. |
| 36 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 63 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 16 kA complete all as specified and directed. |
| 37 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range100 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz25 kA complete all as specified and directed. |
| 38 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 315 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. |
| 39 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 400 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. |
| 40 | S&F Digital Voltmeter of rating 0-500 V, size 96mm square type complete all as specified and as directed. |
| 41 | S&F Digital Ammeter of rating upto 0-600 Amp, size 96mm square type complete all as specified and as directed. |
| 42 | S&F selector switch rotary type as per existing size complete all as specified and as directed. |
| 43 | S&F LED Indicator assy with colour red/ yellow/ blue, complete all as specified and as directed. |
| 44 | Copper Current transformer (CT) ratio 200/5 Amp (Set of 3 Nos), complete all as specified and as directed. |
| 45 | Copper Current transformer (CT) ratio 800/5 Amp (Set of 3 Nos), complete all as specified and as directed. |
| 46 | Copper Current transformer (CT) ratio 600/5 Amp (Set of 3 Nos), complete all as specified and as directed. |
| 47 | Copper Current transformer (CT) ratio 500/5 Amp (Set of 3 Nos), complete all as specified and as directed. |
| 48 | S&F in replacement of MCCB with adjustable thermal and magentic setting type Release Range 630 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 50 kA, 50kA,thermal magnitc O/L and S/C protection, complete all as specified and as directed. |
| 49 | S&F in replacement of ACB Microprossessor relese based type 50Hz, 4 Pole 630Amp 50 KA with electronic protection unit with LSI/ LSIg+NEUTRAL O/L+OVER TEMPERATURE PROTECTION complete all as specified and directed |
| 50 | S&F in replacement of ACB Microprossessor relese based type 50Hz, 4 Pole 800Amp 70 KA,with electronic protection unit with LSI/LSIg+NEUTRAL O/L+OVER TEMPERATURE PROTECTION complete all as specified and directed. |
| 51 | Supply and fix LT spacer 05 way Fix type made out of PVC material and suitable to work on 1100 volts fixed between 05 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed. |
| 52 | Supply and fix LT spacer 04 way Fix type made out of PVC material and suitable to work on 1100 volts fixed between 04 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed. |
| 53 | Supply and fix LT spacer 03 way Fix type made out of PVC material and suitable to work on 1100 volts fixed between 03 conductors in any position along the LT line for any size of conductor along the feeder complete all as specified and directed. |
| 54 | M&L earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.3 mm thick, burried directly in ground vertically in pit of size 900 x 900cm depth not less than 4.0 metre below normal ground level with top edge of the earth plate at a depth not less than 3.4 metre below normal ground level and covered surrounded from all sides with mixture of charcoal and common salt in alternate layers (each layer of 0.23 cu. m) upto 15cm above top of plate and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and as directed.NOTE: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point. |
| 55 | M&L for replacement of unserviceable sheet metal enclosure power distribution board for independent mounting DRX 100 MCCB enclosure, including 63 Amp four pole, 415 volt,10kA and including necessary connection complete all as specified and directed. |
| 56 | M&L for replacement of unserviceable sheet metal enclosure power TPN , 4 way, DPX3 160 MCCB enclosure distribution board, complete all as specified and directed. |
| 57 | S&F in replacement of u/s MCB TP 32 Amp, 415 Volt, 'C' curve including necessary connection complete all as specified and directed. |
| 58 | S&F in replacement of u/s MCB SP 6 to 32 Amp, 415 Volt,'c' curve including necessary connection complete all as specified and directed. |
| 59 | M&L for paint to existing steel tubular 11 mtr pole of any type complete with two coat of aluminium synthetic enamel paint from bottom to top of the pole inculding black and yellow paint upto 1.5 Mtr height from bottom alernaterely strip 30 cm each including providing pole number with white enamel paint and 100 mm dia (round) background of blue enamel paint at site complete all as specified and directed. |
| 60 | All as per ser no 59 here-in before but LT Pole upto 9 mtr, complete all as specified and as directed. |
| 61 | Dismentaling of old steel tubular pole LT/HT after excavation of PCC and disconecting of cross arm and insulators,and shifting it to new location as required on site including all ACSR conductor any size/ cross arm/insulators connections including PCC work with ratio 1:3:6 and coping and testing of overhead line complete all as specified and as directed. |
| 62 | M&L and testing for end termination jointing kit suitable for 1100V, 16- 50 sqmm x 3.5 core XLPE cable heat shrinkable joint Outdoor complete with jointing material & assessories suitable 1.1KV grade cable for end complete all as specified and directed |
| 63 | M&L and testing for end termination jointing kit suitable for 1100V, 70-120 sqmm x 3.5 core XLPE cable heat shrinkable joint outdoor complete with jointing material & assessories suitable 1.1KV grade cable for end complete all as specified and directed |
| 64 | M&L for XLPE grade cable for straight through joint kit suitable for 1100V, 70-150 sqmm, 3.5 core XLPE cable heat shrinable joint, complete all as specified and as directed. |
| 65 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for finding of the cable fault in underground cable and returning filling (including old bricks and sand) the same after rectification of the cable fault in any type of soil complete all as specified and directed. Please Enable Macros to View BoQ information |
| 66 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for finding of the cable fault in underground cable and returning filling (including old bricks and sand) the same after rectification of the cable fault in any type of soil complete all as specified and directed. Please Enable Macros to View BoQ information |