| 1 | Taking down cement plaster or cement lime plaster on PCC/stone surfcae/brick surfaces including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 2 | M & L rendering 10mm thick on brick wall or concrete surface in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed. |
| 3 | M & L rendering 15mm thick on brick wall or concrete surface or other than fair faces in cement mortar (1:4), finished without using extra cement, with water proofing compound, complete all as specified and directed. |
| 4 | M & L for rendering 5mm thick in cement mortar (1:3) on ceiling surfaces, finished even and smooth without using extra cement complete all as specified and directed. |
| 5 | Supply only integral water proofing compund, complete all as specified and directed. |
| 6 | M & L preparation of new plastered surfaces of walls and applying one coats of oil bound distemper over a coat of 1mm putty of approved tint, complete all as specified and directed. |
| 7 | M & L preparation of new plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed. |
| 8 | M & L applying two coats of cement base paint on newly plastered or unplastered wall surface over a coat of cement primer including preparation of surfaces, complete all as specified and directed. |
| 9 | M & L for preparation of newly plastered/unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 10 | M & L for preparation of newly plastered/ unplastered surfaces of ceiling and applying two coats of oil bound distemper complete all as specified and directed. |
| 11 | M & L for preparation of old plastered surfaces of walls including Washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of oil bound distermper, complete all as specified and directed. |
| 12 | M & L for preparation of old plastered surfaces of walls including Washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of oil bound distermper, complete all as specified and directed. |
| 13 | M & L for preparation of old plastered surfaces of walls and applying one coat of cement based paint of approved shade/tint complete all as specified and directed. |
| 14 | M & L for preparation of old plastered surfaces of walls including cornices etc and apllying two coats of white wash, complete all as specified and directed. |
| 15 | M & L for complete removal of existing treatment on walls including Washing, rubbing down and stopping of distempered and painted surfaces and preparation of surfaces of walls and applying 1mm thick wall care putty, complete all as specified and directed. |
| 16 | M & L for complete removal of existing treatment on ceiling including Washing, rubbing down and stopping of distempered and painted surfaces and preparation of surfaces of Ceiling and applying 1mm thick wall care putty, complete all as specified and directed. |
| 17 | M & L for preparation of old wooden surfaces of any description over 10cm girth or widhth no otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 18 | M & L for preparation of old wooden surfaces of any description over 10cm girth or widhth no otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 19 | M & L for preparation of old steel surfaces of any description over 10cm girth or widhth no otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 20 | M & L for preparation of old steel surfaces of any description over 10cm girth or widhth no otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 21 | M & L for hacking out old broken glass(any thickness or size)from wooden, steel, metal, concrete surfaces including punching or drilling out old glazing pins/spring clips and providing and fixing new ones for openings, complete all as specified. |
| 22 | S & F 4.00mm thick plain glass sheet ordinary quality in squares n exe 0.5sqm each and glazing with oil putty/ fixing to the metal frame with necessary pins/spring clips and painting/oiling to the new putty to match the new/existing surfaces, complete all as specified and directed.Note:- The rate includes necessary scaffholding/shuttering or any mechanical means required to reach the requisite floors upto (G+5) from ground level, complete all as specified and directed by Eng-in-Charge. |
| 23 | S & F 4.00mm thick figured glass, pinhead type in squares n exc 0.5 sqm each pane and glazing with oil putty complete all as specified and directed. |
| 24 | M & L for preparation of old existing AC sheet/zincalume sheet/concrete surfaces/previously plastered surfaces of any description and in any position not otherwise described over 10cm width or girth and applying two coats of weather proof exterior emulsion paint over a coat of primer, complete all as specified and directed.Note:- (i) The new pattern camouflaging/(sigma pattern) of color shall be approved by Eng-in-Charge/ Airforce Authority.(ii) The rate quoted by the tenderer is deemed to be included in item for doing new pattern camouflaging(Sigma pattern), any type of building (G+4), walls, including any height and width at AF Stn Sarsawa shall be made good by the contractorwithout any extra cost, complete all as specified and directed by Eng-in-Charge. |
| 25 | M & L for preparation of old existing AC sheet/zincalume sheet/concrete surfaces/previously plastered surfaces of any description and in any position not otherwise described over 10cm width or girth and applying one coat of weather proof exterior emulsion paint over a coat of primer, complete all as specified and directed.Note:- (i) The new pattern camouflaging/(sigma pattern) of color shall be approved by Eng-in-Charge/ Airforce Authority.(ii) The rate quoted by the tenderer is deemed to be included in item for doing new pattern camouflaging(Sigma pattern), any type of building (G+4), walls, including any height and width at AF Stn Sarsawa shall be made good by the contractorwithout any extra cost, complete all as specified and directed by Eng-in-Charge. |
| 26 | M & L for preparation of old painted steel, galvanized sheet and iron surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint in camouflague pattern or plain pattern as decided by Eng-in-Charge, complete all as specified and directed.Note:- The rate quoted by the tenderer is deemed to be included in item for painting in any type of Rolling shutters and any typeof Hangers including any height and width at AF Stn Sarsawa shall be made good by the contractor without any extra cost, complete all as specified and directed by Eng-in-Charge. |
| 27 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-Charge. |
| 28 | Demolition of brick work built in cement mortar incl quoins and arches all as specified and directed by Engineer – in - Charge. |
| 29 | M & L Brick work with sub class 'B' Bricks, straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 30 | M & L for PCC (1:5:10) type E-2 (using 40 mm graded stone aggregate) as in foundation, subbase masonary complete all as specified and directed. |
| 31 | M & L for PCC (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) as in benching, coping etc. including necessary form work complete all as specified and directed. |
| 32 | Taking down chowkats or framed with shutter (with out taking off shutters from the frame) area not exc 1.50 sqm each complete all as specified and directed. |
| 33 | Taking down chowkats or framed with shutter (with out taking off shutters from the frame) area exc 1.50 sqm but n. exc. 4sqm each complete all as specified and directed. |
| 34 | S & F anodised aluminium frame powder coated for doors & windows with one or more rebates including joining cleat for fixing etc complete all as specified and directed. |
| 35 | S & F anodised aluminium windows and ventilators powder coated with frames & shutters with one or more rebates including joining cleats, glazing clips, rubber padding, anodised aluminium snap beading screws etc and necessary aluminium iron mongary for fixing etc complete all as specified and directed. |
| 36 | S & F 5.00 mm thick Plain sheet glass, one side sheet glass is groundor obscured or frosted in squares exc 0.5 sqm each pane and glazing with metal beads including Solar control film 25 micron reflective type sticked to glass panes all as specified all as specified and directed. |
| 37 | S & F 5.00 mm thick figured glass, one side sheet glass is groundor obscured or frosted in squares exc 0.5 sqm each pane all as specified all as specified and directed. |
| 38 | S & F Powder coated Anodised aluminium door shutters,weighing 0.55 kg/Rm, aluminium section including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed. |
| 39 | S & F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge complete all as specified and directed. |
| 40 | S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples and screwed, complete all as specified and directed. |
| 41 | M & L for cutting opening through walls for doors, windows and other openings or enlarging existing openings etc or cutting out defective masonary for underpinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to store and rubbish off the premises, complete all as specified and directed. |
| 42 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation board/slabs/blankets/AC boards, cupboard shelves etc any thickness complete all as specified and directed. |
| 43 | M & L for False ceiling made out of E-board classic of size 595x595x4 mm thick, inseted to timber/aluminium/ GI frame work, complete all as specified and directed. |
| 44 | M & L for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equalflanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting levelfixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners12.5mm dia. 40mm long complete all as specified and directed. |
| 45 | M & L for Complete removal of existing treatment on wall, roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean,free from dust, loose paint etc by skilled labour complete all as specified and directed. |
| 46 | M & L for waterproof cement based putty @ 1 Kg(undiluted) per sq mtr. of thickness 2 mm over the plastered/old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:-Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute.Step 2) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI.Step 3) Allow 6-8 hrs time to dry the putty surface. |
| 47 | M & L for applying two coats of oil bound distemper on walls using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. Note : Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paint application). Please Enable Macros to View BoQ information |
| 48 | M & L for applying two coats of oil bound distemper on walls using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. Note : Sanding of surface to be done by mechanical sander with 1500 - 2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paint application). Please Enable Macros to View BoQ information |