| 1 | Supply, laying, jointing and testing of 25 sqmm,4 core, Low Tension (LT) XLPE insulated in replacement , armoured, heavy duty, electric power cable, aluminum conductor 1100 volts grade underground cable (including both side connection with cable lugs etc, and the connecting the cable to cable glands in looping box) , laid in trench/ passing through pipes / laid over walls etc, including taking old unserviceable cable complete all as specified and as directed Note : Cable gland shall be measured and paid seperately in looping box . |
| 2 | As per item No.1 here in before but for 16 sqmm,4 core,1100 volts grade cable |
| 3 | Excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables/pole and getting out of excavated material complete all as specified and directed. |
| 4 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed. |
| 5 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. |
| 6 | Supply and laying double walled corrugated HDPE pipe of nominal size 50 mm ( inner dia approx 38 mm) along with accessories to pipe joints , as per IS: 16205 part-24, The pipe shall be with the following properties: outer wall corrogated, inner wall plain surface, preferably orange colour,Anti rodency,Non-flame propagation property, permanently lubricated silicone inner layer for smooth cable insertion,Anti-termite property, Pliable , to be used for cable protection & laid in trench complete all as specified and directed |
| 7 | Material & Labour for PCC in foundation, filling and mass concrete, coping etc type B1 1:2:4 (20mm graded stone aggregate). complete all as specefied and directed. |
| 8 | Supply and fixing in replacement LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics, including removing old unserviceable cable, complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge |
| 9 | Supply and fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (9.5 metres long) incl dismantling and taking down old unsv poles complete all as specified and directed by Engr-in-Charge. |
| 10 | M & L in replacement of GI bracket made out of 32 mm dia medium grade GI pipe of length 1.50m, bent to an angle of 30 degree and fixed with 40mm x 6mm flat iron, including suitable 02 set of clamps with nut , bolts ,and washers for fixing of light to pole complete all as specified and as directed. |
| 11 | Material and labour for preparation of old steel surface /pole including scraping and cleaning to remove dust, grease, plaster or any other foreign materials and complete removal of existing treatment and applying one coat of zinc chrome primer & two coats of synthetic enamel all specified and as directed. |
| 12 | Supply and fix in repairs pole mounting type FRP cable looping box with connector , of inner dimension 280 x 235 x 135 mm , with DIN rail for fixing MCB , including brass gland (two nos.) of size selected based on outer dia of 4C x 16 / 25 sqmm cable (approx. 22 mm) and the looping box to be fixed on street light with suitable flat iron arrangement / flushed into foundation platform complete all as specified and as directed. |
| 13 | Supply and fixing in replacement 240V, 10 KA 'B' curve (MCB) of single poles and current carrying capacity 6 to 10 Amp, complete with connection testing and commissioning complete all as specified and as directed. |
| 14 | Supply and fix in replacement PVC insulated two single core 1.5 sqmm FRLS copper conductor and one run of 1.5 sqmm multistranded copper conductor as earth continuity conductor drawn through and including 20mm dia heavy duty non metallic rigid PVC conduit and accessories complete all as specified and as directed.Note : (i)Two runs of 1.5 Sqmm of single core, one run of 1.5 sqmm earth conductor and PVC conduit will be measured as one RM. |
| 15 | Supply and fixing in replacement GI pipe light grade with necessary fittings in floor /piller/fixed on pole of size 40 mm dia complete all as specified |
| 16 | Material and labour for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation of poles including form work and fair finishing to exposed surfaces complete all as specified and as directed by the Engineer-in-Charge. |
| 17 | Material and labour for PCC 1:2:4 type B2 using 40 mm graded stone aggregate as in foundation , coping for poles etc including form work and fair finishing to exposed surfaces complete all as specified and as directed by the Engineer-in-Charge. |
| 18 | Demolition of PCC (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge. |
| 19 | M & L for 100 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed. |
| 20 | Material and labour for writing letters or figures (Block.Roman, Italic or Indian) 5 cm high in blue/ black coloured background circle complete all specified and as directed. |
| 21 | Supply & fix in replacement and testing of Search light LED 200 watts, 230 volts suitable with suitable electronic driver , fixed in 1 meter height tripod stand with castrol wheels , with following specifications :- Housing : Die Cast Aluminium Alloy Housing having high conductivity heat sinks, LED lumen output ≥ 156 lm/W, Luminar Efiicacy>90%, CRI - 70, THD< 10%, IP 66, Protections: External 10 kV surge protection & internal 4kV surge protection, short circuit , overcurrent, overvoltage, over temperature protection. The fitting shall be supplied with W optic lense for uniform light distribution. Make : SIGMA Type No 24831L - TS or its equivalent in HAVELLS/CG/PHILIPS/HPL |
| 22 | Supply and fix in replacement PVC insulated two single core 2.5 sqmm FRLS copper conductor and one run of 2.5 sqmm multistranded copper conductor as earth continuity conductor drawn through and including 20 mm dia heavy duty non metallic rigid PVC conduit and accessories complete all as specified and as directed.Note : (i)Two runs of 2.5 Sqmm cable, one run of 2.5 sqmm earth conductor and PVC conduit will be measured as one RM |
| 23 | Supply and fix Sheet metal enclouser with socket plug top and MCB SPN 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for Search light ) including taking down old unserviceable old unserviceable Sheet metal enclousers with socket plug top complete all as specified and directed. |
| 24 | M & L for earthing in replacement complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 in SSR part 1 (2010 edition) connected to earthing test point,including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip and etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wiremesh ,funnel,lugs and charcoal,salt etc all as applicable complete all as specified and as directed by the Engineer-in-ChargeNote : GI strip and protection pipes 20 mm GI light grade up to 7.5 metre is included in unit rate and beyond that the same will be measured separately. |
| 25 | Supply & fixing in replacement for GI wire 4 mm on wall/batten or recessed or buried in ground all as directed |
| 26 | Supply and fixing in replacement Cable gland suitable for 4C x 16 Sqmm cable of overall dia 20.0-23.0 mm and fixing the cable gland to looping box and making connecion to cable |
| 27 | Supply and fixing in replacement Cable gland suitable for 4C x 25 Sqmm cable of overall dia 23.0-26.0 mm and fixing the cable gland to looping box and making connecion to cable |
| 28 | M & L Sub main wiring in replacement with four run single core 4 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 4 sq mm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 25 mm dia including conduit accessories all as specified and directed. Note: Five runs of 4 Sqmm cable and one run of 25 mm conduit will be measured as one unit length. |
| 29 | Point wiring concealed in walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 sq mm (nominal area) multi stranded copper conductor cable drawn though in and including non metallic medium grade in stove enamelled steel conduit, conduit heavy grade accessories, ISI marked, 20 mm dia including all accessories, concealed in walls by cutting chases using machine and making good the disturbed surface, with and including suitable 1.5 sq mm copper earth continuity wire connected to earth dolly complete for One light point/ fan point controlled by one switch. |
| 30 | As per item No.29 here in before but for One 3 pin socket outlet point. 15 amps, independent point, with cables of 4 sq.mm size |
| 31 | Supply and fix Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body |
| 32 | Supply and fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as directed. |
| 33 | Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor. |
| 34 | Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size. complete all as specified and as directed. |
| 35 | Supply and fix new sheet metal enclosure powder coated double door for Distribution Board, VTPN 4 way DB suitable for MCCB incomer (upto 125 A ),415 V with Detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including disconnecting electric connections and dismantling from position unserviceable DBs complete for taking into credit all as specified and as directed. |
| 36 | Supply and fix new MCB TPN 40A- 100 A , B curve 10 kA including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed. |
| 37 | Supply and fix new MCB SP 5 A to 32 A , B curve, 10 kA including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed. |
| 38 | Supply and fix new MCCB 100 A, 16 KA, with thermal magnetic protection including disconnecting electric connections, dismantling from position unserviceable MCCB for taking into credit complete all as specified and as directed. |
| 39 | Supply and fix new MCCB 63 A, 16 KA, with thermal magnetic protection including disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed. |
| 40 | Supply and fix flame proof exhaust fan 300 mm complete all as specified and as directed. Please Enable Macros to View BoQ information |