| 1 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer incharge:1:3:6 or richer mix (i/c equivalent design mix) |
| 2 | Making the opening for door/window/clerestory window in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground. |
| 3 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge in all kind of soil. |
| 4 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil |
| 5 | Extra for every additional lift of 1.5 M or part therefore in all kinds of soil. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate) 40mm nominal size crushed. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 8 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with:1:1½:3 (1 cement :1½ coarse sand: 3 graded stone aggregate 20 mm nominal size)). |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as perapproved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. All works upto plinth level. |
| 11 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as perapproved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge.All works above plinth level upto floor V level. |
| 12 | Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete TMT bars.((Thermo-Mechanically Treated bars of grade Fe-500D or more.)) |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form work for :- |
| 14 | Foundations, footings, bases of columns etc. For mass concrete. |
| 15 | Column, Pillars, Piers, Abutments, Posts and Struts. |
| 16 | Lintel, beams, plinth beam, girders, bressumers and cantilevers. |
| 17 | Suspended floors, roofs, landings, balconies and access platforms. |
| 18 | Edges of slabs and breaks in floors and walls upto 20cm wide. |
| 19 | Brick work with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 fine sand).(Below Plinth) |
| 20 | Brick work with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:6 (1 cement : 6 fine sand). |
| 21 | Extra for brick work in super structure above plinth level upto floor V-level. |
| 22 | 6mm Cement Plaster to Ceiling of Mix 1:3(1 Cement:3 Fine Sand) |
| 23 | 12mm Cement Plaster of Mix 1:6 (1 Cement :6 Fine Sand) |
| 24 | 15mm Cement Plaster on the rough side of single or half brick wall of Mix 1:6 ( 1 Cement: 6 Fine Sand) |
| 25 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead upto 50Mt & lift upto 1.50M. |
| 26 | Supplying and filling in plinth with fine sand under floors including, watering, ramming consolidationg and dressing complete. |
| 27 | Making of grove 12mm x 10mm between brick and RCC. |
| 28 | Making plinth protection 50mm thick cement concrete 1:3:6 (1 cement : 3 course sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth crushed. |
| 29 | Brick edging 7 cm wide 11.4cm deep to plinth protection with bricks of class designation 75mm including grouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 30 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size below flooring, retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing. |
| 31 | Providing and laying 75mm thick compacted bed of dry brick aggregate 40mm thick nominal size including spreading, well rammed, consolidated and grouted with fine sand including finishing smooth etc. complete as per direction of Engineer-in-charge |
| 32 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc. (Make Armocreate of SWC Chryso France) consisting of (a) applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks / brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining was upto 300mm height including rounding of junction of walls and slaps.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. (iv) Finishing the surface with 20mm thick joint less cement mortar of mix 1: 4 admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fiber cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm / sq 3mm deep. (e) The whole terrace so finished shall be flooded with water far a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer-in-charge. With average thickness of 120mm and minimum thickness at khurras as 65mm |
| 33 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 34 | Providing and laying Vitrified tiles in different sizes (thickness to bespecified by manufacturer), with water absorption less than 0.08 % andconforming to I.S. 15622, of approved make, in all colours and shades,in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), including grouting the joint with white cementand matching pigments etc. complete.11.56.1 Size of tile 500x500 mm |
| 35 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 36 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 37 | Extra for providing edge moulding to 18/16 mm thick Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. |
| 38 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Raj Nagar plain white marble/Udaipur green marble/zebra black marble (Area of slab upto 0.5 sqm) |
| 39 | Providing and fixing aluminium work for doors, windows, ventilators andpartitions with extruded built up standard tubular sections/appropriate Z. sections and other sections of approved make conforming to IS : 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junctions at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge (glazing and panelling to be paid for separately).a) For fixed portion using Powder coated aluminium (minimum thickness of powder coated 50 microns). |
| 40 | For shutters of doors, windows and ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coated 50 microns). |
| 41 | Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S Flat 15x3 mm and nuts and bolts complete.10.29.2 Stainless steel (grade 304) wire gauze of 0.5mm dia wire and 1.4 mm aperture on both sides. |
| 42 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partition etc. with PVC / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item). With glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm). |
| 43 | Beading |
| 44 | Filling the gap in between aluminum frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 45 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 46 | 150X10mm |
| 47 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 48 | Providing and fixing bright/ matt finished stainless Steel handles of approved quality & make with necessary screws etc. All complete |
| 49 | 100MM |
| 50 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Single socketed pipes of 110mm diameter. |
| 51 | Providing and fixing un-plasticised -PVC pipe clips of approved design to un-plasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 52 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams. |
| 53 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including elding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary tainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 54 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 55 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacture,over the plasterted wall surface to prepare the surface even and smooth complete |
| 56 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm |
| 57 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over andincluding priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 58 | Providing and fixing G.I. pipes complete with G.I. fittings excludingtrenching and refilling etc. (external work) 32 mm dia. nominal bore (Medium) |
| 59 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work. |
| 60 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer, |
| 61 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 62 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 meter lead as per direction of Engineer-in-Charge. |
| 63 | Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in- charge. |
| 64 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. |
| 65 | Carriage of material by Mechanical Transport including loading / unloading and stacking at site complete. |
| 66 | Sand for an average lead of 15 Kms. |
| 67 | Stone aggregate below 40mm size for an average lead of 15 Kms. |
| 68 | Stone aggregate above 40mm size for an average lead of 15 Kms. |
| 69 | Bricks for an average lead of 20 Kms |
| 70 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group-A |
| 71 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loopearthing as required. |
| 72 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. |
| 73 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 74 | 2 x 10 sq. mm + 1 x 6 sq. mm earth wire |
| 75 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.1 x 1.5 sq. mm |
| 76 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 77 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 78 | 5/6 A switch |
| 79 | 3 pin 5/6 A socket outlet |
| 80 | 15/16 A switch |
| 81 | 6 pin 15/16 A socket outlet |
| 82 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 83 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 84 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 85 | Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc. |
| 86 | 4 Way (4+12), (Double door ) (TPN type) |
| 87 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. ,conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. |
| 88 | Single pole 6/10/16/32 Amp |
| 89 | Single pole and neutral 40 Amp |
| 90 | Single pole and neutral 63 Amp |
| 91 | Supplying, Installation, Testing & Commissioning of 36 watt Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained tilllife ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(StandardDeviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 92 | Supplying and fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuitprotection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more thanthe specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved byEngineer in charge.20/22 watt LED 4 feet with min. lumen output (2000- 2200) lm |
| 93 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 94 | Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required. |
| 95 | Ceiling fan 1200 mm sweep alongwith rod upto 1'-6\\" long (3 Star) |
| 96 | Exhaust fan 300 mm size (Metalic) |
| 97 | Exhaust fan 300 mm size (PVC ) with lovers |
| 98 | Supplying & fixing of following electrical items |
| 99 | Deep Box 4\\" |
| 100 | Ceiling Rose |
| 101 | Fan Box (Ceiling) 5\\" |
| 102 | Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces also includes erection on pole, as required/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench (Armoured cable) alongwith thimbles, nuts bolts of sizes etc. as required. |
| 103 | 70 sq. mm 3.5 core |
| 104 | 95 sq. mm 3.5 core |
| 105 | 300 sq. mm 3.5 core Please Enable Macros to View BoQ information |