| 1 | Estab. of 765kV Kolhapur (PG) GIS SsSUPPLY- GIS : 765kV, 50KA FOR 1S, GAS INSULATED SWITCHGEAR (GIS) AS PER TS (for item sl. No. 1.01-1.11):800kV, 3150 A, 50 kA, SF6 GIS ICT feederbay module as per Section-Project,Technical specification |
| 2 | 800kV, 3150A, 50kA, SF6 GIS Bus Reactorfeeder bay module as perSection-Project, Technicalspecification |
| 3 | 800kV, 3150A ,50kA, GIS Line feeder baymodule (with PIR) as perSection-Project, Technicalspecification |
| 4 | 800 kV, 3150A, 50kA, SF6 GIS Tie baymodule(with PIR) as perSection-Project, Technicalspecification |
| 5 | 800kV, 3150A, 50kA, SF6 GIS Auxiliarybus module for spare transformer as perSection-Project, Technicalspecification |
| 6 | 800 KV, 3150A, 50KA, SF6 GIS AUXILIARY BUS MODULE FOR SPARE REACTOR ASPER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 7 | 800kV, 3000/3150 A, 50kA, Single phase, SF6 Gas Insulated Bus Duct (GIB) outside GIS Hall along with associated support structure. |
| 8 | Controlled Switching Device for 765 kV, 3-ph Circuit Breaker |
| 9 | 765KV, 3150A, 50KAFOR 1 SEC, SINGLE PHASE, SF6 TO AIR BUSHINGALONGWITH ASSOCIATED SUPPORT STRUCTURE |
| 10 | 800kV, 3150A, 50kA, SF6 GIS SwitchableLine Reactor feeder bay module as perSection-Project, Technicalspecification |
| 11 | 800KV, 5000A, 50KA, SF6 GIS BUS BAR MODULE as perSection-Project, Technicalspecification |
| 12 | SUPPLY- GIS : 765KV, SPECIAL TOOLS AND TESTING & MAINTENANCE EQUIPMENTS AS PER TS (for ietm sl. No. 2.01-2.05):SF6 Gas Filling and Evacuation Plant for 800kV GIS station |
| 13 | Portable Partial Discharge measurement test kitwith all necessary accessories,Industrial Grade Laptop and licensedsoftware as per Technicalspecification. |
| 14 | SF6 GAS ANALYZER |
| 15 | SF6 Gas Leakage Detector |
| 16 | SCISSOR LIFT |
| 17 | SPARES- GIS : 765KV, 50KA FOR 1S, MANDATORY SPARES AS PER TS (For ietm sl. No. 3.01-3.53):765KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE |
| 18 | SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-765KV GIS |
| 19 | COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-765KV GIS |
| 20 | RUBBER GASKETS, 'O' RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-765KV GIS |
| 21 | 765KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) |
| 22 | CONTROL VALVES FOR SF6 GAS OF EACH TYPE-765KV GIS |
| 23 | 765KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) |
| 24 | LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES IN CLOSE OR OPEN POSITION IN CASEOF REMOVAL OF THE DRIVING MECHANISM-765KV GIS |
| 25 | UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 765KV GIS |
| 26 | 765KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS |
| 27 | 765KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS |
| 28 | 765KV GIS- 3150A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT |
| 29 | LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES, LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-765kV GIS |
| 30 | 765KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITHOUT PIR WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETEIN ALL RESPECT |
| 31 | 765KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITH PIR WITH INTERRUPTER,MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALLRESPECT |
| 32 | Trip coil assembly with resistor for765kV GIS Circuit Breaker (asapplicable) |
| 33 | Closing coil assembly with resistor for765 kV GIS Circuit Breaker (asapplicable) |
| 34 | RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 765KV GIS CIRCUIT BREAKER |
| 35 | Auxiliary switch assembly of each type for 765kV GIS Circuit Breaker |
| 36 | 765KV GIS CIRCUIT BREAKER-OPERATION COUNTER |
| 37 | 765KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) |
| 38 | HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-765KV GIS CIRCUIT BREKAER |
| 39 | 765KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) |
| 40 | 765KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) |
| 41 | VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-765KV GIS CIRCUIT BREKAER |
| 42 | PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER |
| 43 | PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-765KV GIS CIRCUIT BREKAER |
| 44 | PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER |
| 45 | 765KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) |
| 46 | PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-765KV GIS CIRCUIT BREKAER |
| 47 | 765KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) |
| 48 | 765KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) |
| 49 | PRESSURE SWITCHES OF EACH TYPE FOR 765KVGIS CIRCUIT BREAKER (ForHydraulic-Spring Operated Mechanism, ifapplicable) |
| 50 | PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER |
| 51 | 765kV GIS- Single phase of 3150Adisconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect |
| 52 | 765KV GIS- SINGLE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT |
| 53 | 765KV GIS - SINGLE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT |
| 54 | OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 765KV GIS DISCONNECTORSWITCH |
| 55 | OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 765KV GIS MAINTENANCE EARTHSWITCH |
| 56 | OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 765KV GIS FAST EARTHINGSWITCH |
| 57 | LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-765KV GIS |
| 58 | LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-765KV GIS |
| 59 | LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-765KV GIS |
| 60 | DRIVE MECHANISM FOR 765KV GIS DISCONNECTOR SWITCH |
| 61 | DRIVE MECHANISM FOR 765KV GIS MAINTENANCE EARTH SWITCH |
| 62 | DRIVE MECHANISM FOR 765KV GIS FAST EARTHING SWITCH |
| 63 | MOTOR FOR DRIVE MECHANISM FOR 765KV GIS DISCONNECTOR SWITCH |
| 64 | MOTOR FOR DRIVE MECHANISM FOR 765KVGIS MAINTENANCE EARTH SWITCH |
| 65 | MOTOR FOR DRIVE MECHANISM FOR 765KV GIS FAST EARTHING SWITCH |
| 66 | 765KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (3 CORES, TYPE-CTA)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT |
| 67 | 765KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (2 CORES, TYPE-CTB)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT |
| 68 | 765KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT |
| 69 | Controlled Switching Device for 765 kV, 3-ph Circuit Breaker |
| 70 | SUPPLY- GIS : 765KV, 50KA FOR 1S, REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS (UNIT PRICES OF INDIVIDUAL EQUIPMENT INCLUDED HERE OR IN MANADATORY SPARES ARE REQUIRED FOR ANY ADDITION/DELETION OF EQUIPMENT AND REPLACEMENT OF DAMAGED ITEMS. VENDOR TO ENSURE THAT THE UNIT PRICES HAVE A LOGICAL RELATIONSHIP WITH PRICES OF ASSEMBLIES IN MAIN ITEMS. QUOTING FOR UNIT PRICES IS MANDATORY AND SHALL BE CONSIDERED FOR EVALUATION) (For item sl. No. 4.01-4.06): SUPPLY- GIS : 765KV, SINGLE PHASE BUS BAR |
| 71 | SUPPLY- GIS : 765KV, GIS METALLIC ENCLOSURE |
| 72 | SUPPLY- GIS : 765KV, EXPANSION BELLOWS/ JOINTS |
| 73 | SUPPLY- GIS : 765KV, TEE BEND |
| 74 | SUPPLY- GIS : 765KV, ANGLE BEND |
| 75 | SUPPLY- GIS : 765KV, L-BEND |
| 76 | SERVICES- GIS : 765KV, 50KA FOR 1S, GAS INSULATED SWITCHGEAR (GIS) AS PER TS (For item sl. No. 5.01-5.09):SERVICES- GIS : 765KV, SUPERVISION OF ERECTION OF GIS |
| 77 | SERVICES- GIS : 765KV, SUPERVISION OF ERECTION OF GAS INSULATED BUS DUCT |
| 78 | SERVICES- GIS : 765KV, SUPERVISION OF ERECTION OF SF6 TO AIR BUSHING |
| 79 | SERVICES- GIS : 765KV, TESTING & COMMISSIONING OF GIS |
| 80 | SERVICES- GIS : 765KV, TESTING & COMMISSIONING OF GAS INSULATED BUS DUCT |
| 81 | SERVICES- GIS : 765KV, TESTING & COMMISSIONING OF SF6 TO AIR BUSHING |
| 82 | SERVICES- ETC OF CONTROLLED SWITCHING DEVICE FOR 765 KV, 3-PH CIRCUIT BREAKER |
| 83 | SERVICES- GIS : 765KV, FINAL SUCCESSFUL HV/ POWER FREQUENCY TESTING OF GIS INCLUDING ARRANGING OF HV TEST KIT ALONG WITHOPERATOR |
| 84 | SERVICES- GIS : INSULATION CO-ORDINATION STUDIES FOR GIS SYSTEM |
| 85 | SERVICES- GIS : 765KV, 50KA FOR 1S, REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICESSERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES(UNIT PRICES OF INDIVIDUAL SERVICES INCLUDED HERE ARE REQUIRED FOR ANY ADDITION/DELETION OF EQUIPMENT AND REPLACEMENT OF DAMAGED ITEMS. VENDOR TO ENSURE THAT THE UNIT PRICES HAVE A LOGICAL RELATIONSHIP WITH PRICES OF ASSEMBLIES IN MAIN ITEMS. QUOTING FOR UNIT PRICES IS MANDATORY AND SHALL BE CONSIDERED FOR EVALUATION) (For item sl. No. 6.01-6.05):SERVICES- GIS : 765KV, REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR SUPERVISION OF ERECTION OF GIS |
| 86 | SERVICES- GIS : 765KV, REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR TESTING & COMMISSIONING OF GIS |
| 87 | SERVICES- GIS : 765KV, DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GIS ERECTION SUPERVISION TEAM |
| 88 | SERVICES- GIS : 765KV, DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GIS TESTING & COMMISSIONING TEAM |
| 89 | SERVICES- GIS : 765KV, DEMOBILIZATION & REMOBILIZATION CHARGES OF HV TEST KIT ALONG WITH OPERATOR |
| 90 | Extn. of 400kV Kolhapur (PG) GIS SsSUPPLY- GIS : 400kV, 63KA FOR 1S, GAS INSULATED SWITCHGEAR (GIS) AS PER TS (for item sl. No. 1.01-1.10):420kV, 3150 A, 63 kA, SF6 GIS AuxiliaryBus module for Spare Transformer as perSection-Project, Technicalspecification |
| 91 | 420KV, 3150A, 63KA SF6 TO AIR BUSHING including support structure |
| 92 | Controlled Switching Device for 420 kV, 3-ph Circuit Breaker |
| 93 | 420KV, 3150 A, 63 KA, SF6 GIS ICT FEEDER BAY MODULE FOR IV SIDECONNECTION WITH 765KV ICT AS PER SECTION-PROJECT, TECHNICALSPECIFICATION |
| 94 | 420KV, 3000A, 63KA, SINGLE PHASE, SF6 GAS INSULATED BUS DUCT (GIB)OUTSIDE GIS HALL ALONGWITH ASSOCIATED SUPPORT STRUCTURE, ETC. AS PERTECHNICAL SPECIFICATION |
| 95 | 420 kV, 3150 A, 63 kA, SF6 GIS Linefeeder bay module(with PIR) as perSection-Project, Technicalspecification |
| 96 | 420kV, 3150 A, 63 kA, SF6 GIS Tie baymodule(with PIR) as perSection-Project, Technicalspecification |
| 97 | 420KV, 4000A,63KA GIS BUSBAR MODULE EXTENSION |
| 98 | 420KV,4000A, 63KA, 3-PHASE GIS EXTENSION PIECE (INTERFACE) MODULESUITABLE FOR EXTENDING EXISTING HITACHI MAKE GIS BUS BAR/DUCT AS PERTECHNICAL SPECIFICATION |
| 99 | 420KV, 3150 A, 63 KA, SF6 GIS SWITCHABLE LINE REACTOR BAY MODULE ASPER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 100 | SPARES- GIS : 400kV, 63KA FOR 1S, MANDATORY SPARES AS PER TS (for ietm sl. No. 2.01-2.52):400KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE |
| 101 | SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-400KV GIS |
| 102 | COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-400KV GIS |
| 103 | RUBBER GASKETS, 'O' RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-400KV GIS |
| 104 | 400KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) |
| 105 | CONTROL VALVES FOR SF6 GAS OF EACH TYPE-400KV GIS |
| 106 | 400KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) |
| 107 | LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES IN CLOSE OR OPEN POSITION IN CASEOF REMOVAL OF THE DRIVING MECHANISM-400KV GIS |
| 108 | UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 420KV GIS |
| 109 | 400KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS |
| 110 | 400KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS |
| 111 | 400KV GIS- 3150A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT |
| 112 | LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES,LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-400kV GIS |
| 113 | 400KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITHOUT PIR WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETEIN ALL RESPECT |
| 114 | 400KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITH PIR WITH INTERRUPTER,MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALLRESPECT |
| 115 | Trip coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable) |
| 116 | Closing coil assembly with resistor for420kV GIS Circuit Breaker (asapplicable) |
| 117 | RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (ASAPPLICABLE) OF EACH TYPE FOR 400KV GIS CIRCUIT BREAKER |
| 118 | Auxiliary switch assembly of each type for 420kV GIS Circuit Breaker |
| 119 | 400KV GIS CIRCUIT BREAKER-OPERATION COUNTER |
| 120 | 400KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) |
| 121 | HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-400KV GIS CIRCUIT BREKAER |
| 122 | 400KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) |
| 123 | 400KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) |
| 124 | VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER |
| 125 | PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER |
| 126 | PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER |
| 127 | PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER |
| 128 | 400KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) |
| 129 | PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-400KV GIS CIRCUIT BREKAER |
| 130 | 400KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) |
| 131 | 400KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) |
| 132 | PRESSURE SWITCHES OF EACH TYPE FOR420KV GIS CIRCUIT BREAKER (ForHydraulic-Spring Operated Mechanism, ifapplicable) |
| 133 | PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER |
| 134 | 400kV GIS- Single phase of 3150A disconnector switch including maincircuit, enclosure, driving mechanismand support insulator etc., complete inall respect |
| 135 | 400KV GIS- SINGLE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT |
| 136 | 400KV GIS - SINGLE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT |
| 137 | OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS DISCONNECTORSWITCH |
| 138 | OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS MAINTENANCE EARTHSWITCH |
| 139 | OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS FAST EARTHINGSWITCH |
| 140 | LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-400KV GIS |
| 141 | LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-400KV GIS |
| 142 | LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-400KV GIS |
| 143 | DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH |
| 144 | DRIVE MECHANISM FOR 400KV GIS MAINTENANCE EARTH SWITCH |
| 145 | DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH |
| 146 | MOTOR FOR DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH |
| 147 | MOTOR FOR DRIVE MECHANISM FOR 400KVGIS MAINTENANCE EARTH SWITCH |
| 148 | MOTOR FOR DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH |
| 149 | 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (3 CORES, TYPE-CTA)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT |
| 150 | 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (2 CORES, TYPE-CTB)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT |
| 151 | Controlled Switching Device for 420 kV, 3-ph Circuit Breaker |
| 152 | SUPPLY- GIS : 400kV, 63kA FOR 1S, REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS (Unit Prices of Individual Equipment included here or in manadatory spares are required for any Addition/Deletion of Equipment and replacement of damaged items. Vendor to ensure that the unit prices have a logical relationship with prices of assemblies in main items. Quoting for unit prices is mandatory and shall be considered for evaluation) (For item sl. No. 3.01-3.06): SUPPLY- GIS : 400kV, SINGLE PHASE BUS BAR |
| 153 | SUPPLY- GIS : 400kV, GIS METALLIC ENCLOSURE |
| 154 | SUPPLY- GIS : 400kV, EXPANSION BELLOWS/ JOINTS |
| 155 | SUPPLY- GIS : 400kV, TEE BEND |
| 156 | SUPPLY- GIS : 400kV, ANGLE BEND |
| 157 | SUPPLY- GIS : 400kV, L-BEND |
| 158 | SERVICES- GIS : 400kV, 63kA FOR 1S, GAS INSULATED SWITCHGEAR (GIS) AS PER TS (For item sl. No. 4.01-4.09):SERVICES- GIS : 400kV, SUPERVISION OF ERECTION OF GIS |
| 159 | SERVICES- GIS : 400kV, SUPERVISION OF ERECTION OF GAS INSULATED BUS DUCT |
| 160 | SERVICES- GIS : 400kV, SUPERVISION OF ERECTION OF SF6 TO AIR BUSHING |
| 161 | SERVICES- GIS : 400kV, TESTING & COMMISSIONING OF GIS |
| 162 | SERVICES- GIS : 400kV, TESTING & COMMISSIONING OF GAS INSULATED BUS DUCT |
| 163 | SERVICES- GIS : 400kV, TESTING & COMMISSIONING OF SF6 TO AIR BUSHING |
| 164 | SERVICES- ETC OF CONTROLLED SWITCHING DEVICE FOR 420 KV, 3-PH CIRCUIT BREAKER |
| 165 | SERVICES- GIS : 400kV, FINAL SUCCESSFUL HV/ POWER FREQUENCY TESTING OF GIS INCLUDING ARRANGING OF HV TEST KIT ALONG WITHOPERATOR |
| 166 | SERVICES- GIS : INSULATION CO-ORDINATION STUDIES FOR GIS SYSTEM |
| 167 | SERVICES- GIS : 400kV, 63kA FOR 1S, REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICESSERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES(Unit Prices of Individual services included here are required for any Addition/Deletion of Equipment and replacement of damaged items.Vendor to ensure that the unit prices have a logical relationship with prices of assemblies in main items. Quoting for unit prices is mandatory and shall be considered for evaluation) (For item sl. No. 5.01-5.05):SERVICES- GIS : 400kV, REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR SUPERVISION OF ERECTION OF GIS |
| 168 | SERVICES- GIS : 400kV, REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR TESTING & COMMISSIONING OF GIS |
| 169 | SERVICES- GIS : 400kV, DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GIS ERECTION SUPERVISION TEAM |
| 170 | SERVICES- GIS : 400kV, DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GIS TESTING & COMMISSIONING TEAM |
| 171 | SERVICES- GIS : 400kV, DEMOBILIZATION & REMOBILIZATION CHARGES OF HV TEST KIT ALONG WITH OPERATOR Please Enable Macros to View BoQ information |