|
| 1 | OD47670/2026-2027:Earthwork in excavation by manual means in hill/forest terrain in hard soil mixed with small rock fragments, including excavation and incidental handling, complete, executed under restricted site conditions with no scope for mechanical means, resulting in reduced labour productivity and increased manual effort. |
| 2 | 60.5.1:DOWEL BARS - Supplying and providing MS dowel bars of size 20 mm dia , 1.5m long (1m in rock and 0.5 m in concrete ) including drilling holes of 25mm dia and filling the gap with cement grout ( 0.25kg/each) etc complete |
| 3 | 4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 5 | 5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 6 | 10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 7 | 10.16.1:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 8 | OD25922/2026-2027:Providing and threading of MS anchor rods of specified diameter including cutting to length, machining of threads to required length, finishing, and making suitable for fixing with nuts and washers, complete. |
| 9 | OD25916/2026-2027:Providing and hot dip galvanizing of structural steel members including surface preparation by degreasing, pickling in acid, rinsing, fluxing, drying and dipping in molten zinc to achieve uniform zinc coating of required thickness, including finishing, handling and transportation to and from galvanizing plant, complete as per relevant IS codes (IS 4759).with minimum zinc coating of 610 g/sqm (or specified) |
| 10 | 13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work |
| 11 | OD25932/2026-2027:Hiring 7.5 KVA Generator on hire basis, including transportation to site, installation, fuel, etc complete |
| 12 | OD25943/2026-2027: Transport of materials through forest terrain in 1.4 cum pik-up under rough terrain conditions with reduced speed and higher fuel and maintenance needs compared to paved-road operations |
| 13 | OD25945/2026-2027:Engaging coolies for manual loading and unloading of materials carried as head loads through forest areas or trek paths. |
| 14 | 90.3.17.3:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe |
| 15 | 6.2:Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 16 | 90.16.3.10:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 6 mm copper strip |
| 17 | 5.10:Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 18 | OD26420/2026-2027:Earthing with maintenance-free chemical earthing electrode of 50 mm dia copper bonded/GI, 1.2 m long, complete with backfill compound, testing as required. including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as required |
| 19 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 20 | OD26346/2026-2027:Supply, Installation, Testing and Commissioning of SPD for 3 phase MSB- Prewired, sparkgap-based type 1 + type 2 combined lightning current and surge arrester consisting of a base part and plug-in protection module SPD according to EN 61643-11 / ... IEC 61643-11 type 1 + type 2 / class I + class II Energy coordination with terminal equipment ( 10 m) type 1 + type 2 + type 3 Nominal voltage (a.c.) (UN) 230 / 400 V (50 / 60 Hz) V Max. continuous operating voltage (a.c.)[L-N]/[N-PE] (UC) 255 V (50 / 60 Hz) Lightning impulse current (10/350 µs)[L1+L2+L3+N-PE] (Itotal) 100 kA Specific energy [L1+L2+L3+N-PE] (W/R) 2.50 MJ/ohms Lightning impulse current (10/350 µs) [L-N]/[N-PE] (Iimp) 25 / 100 kA |
| 21 | OD26479/2026-2027:Engaging wire man |
| 22 | OD26356/2026-2027:Supply and installation of solar panel 250W/24V with 10 year warranty |
| 23 | OD26376/2026-2027:Supply and installation of battery (tubular) 150Ah/12V, C-10 with 5 year warranty |
| 24 | OD26375/2026-2027:Battery Charge Controller Solar charge controller to regulate charging of battery 5yr warranty |
| 25 | OD26374/2026-2027:Energiser Saftey standards with BIS 302-2-76 IEC 335-2-76, switch High- Medium-Low power setting. Solar panel option to recharge 12V battery, full and reduced power output terminals operate different fences independently |
| 26 | OD26372/2026-2027:Supply and fixing corner post assembly 8 feet 2', 14 gauge thickness including cost of G.I pipe cutting, welding, painting and fixing |
| 27 | OD26371/2026-2027:Supply and installation of Supporting posts 8 ft 1', 14 gauge thickness |
| 28 | OD26370/2026-2027:Intermediate posts 8 ft (25mmx25mmx3mm) T post or 16mm TMT rod, including cost of T post, Cutting welding charges etc., (Limit to actual) |
| 29 | OD26369/2026-2027:Strain insulator Must of Polypropelene plastic rated for 15 KV, UV stabilised |
| 30 | OD26373/2026-2027:Leadout cable Double insulated with standing 15 KV voltage and inner core wire must be hot dip galvanised |
| 31 | OD26368/2026-2027:PP Reel Insulator Must be of virging plastic material polypropelene or equivalent |
| 32 | OD26364/2026-2027:Gate Set 02 Gate, with 05 Steel rope with handle (Five handles for one gate) and spring assembly. Handle to be made of polythelene |
| 33 | OD26366/2026-2027:Tension Spring 15 cm length with stand 300kg |
| 34 | OD26360/2026-2027:14 guage winding wire High quality zinc coated wire |
| 35 | OD26362/2026-2027:Supply of 12 Guage ACSR wire 12 guage 2.5mm wire dia |
| 36 | OD26363/2026-2027:Earth Device Steel Rod with earthing mixture (1.5" pipe) 6 ft pipe must contain earth mixture capable of retaining moisture and 8mm dia copper plated IS-3043 rod non-rusting quality with earthing compound 10kg/km |
| 37 | OD26361/2026-2027:Supply of C- clamp 60 Micron thick |
| 38 | OD26365/2026-2027:Wire tightener In suit tightners for proper tensioning of wires should be made from alloy-nonrusting quality |
| 39 | OD26359/2026-2027:Tool Kit Includes wire tighting handle, twisting tool, Pilers, Double handed spanner |
| 40 | OD26367/2026-2027:Joint Clamps with Nut and Bolts Spring steel capable of taking compression loads, galvanised |
| 41 | OD26357/2026-2027:Digital Volt meter Must disply Fence voltage, digitally upto 12KV, made of non-shocking material |
| 42 | OD26358/2026-2027:Base unit box with stand 18 guage thickness lockable GI steel box, GI sheet painted and fixed on 100 NB class and should be capable of housing Battery and Energiser |
| 43 | OD26480/2026-2027:Engaging wire man |
| 44 | GST Please Enable Macros to View BoQ information |