| 1 | RESOURCE RECOVERY CENTRE |
| 2 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand,silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering, and baling out water wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15cm thick well rammed and completed depositing the surplus excavated soil with in the compound in places shown by the departmental officers with intial lead and lifts and cleaning and levelling the site etc.,complete as per TNSS 23 & 24, V, VI (S2), VII, 9,10 |
| 3 | Supply delivery and filling of Stone dust Layer of not more than 15cm thick including watering with all layers and consolidation complying with standard specification including cost and conveyance of sand at site and all labour charges and all other incidential charges etc., complete as per Standard Specification TNSS No. 24 & 25. |
| 4 | Plain Cement Concrete of mix 1 : 4 : 8 (One part of Cement four part of sand eight part of aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. TNDSS NO: 28 V, VI (S2) V,VI (S5A) VII |
| 5 | Supplying and errecting centering for Sides and Soffits including necessary supports and strutting upto3.29mt height for plane surfaces as detailed below in all floors with all cross bracings using mild steel sheets of size 90mm x60mm and 10BG stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 90cm centre to centre and supported by casurina props of 10cm to 13cm dia supported at not more than 75cm centre to centre etc complete Complying with standard Specification without Strutting.( TNSS NO or NBC No 30(S) 86 86 A V, VI(S3)VII |
| 6 | Below Ground Level |
| 7 | Ground Floor Column |
| 8 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. (No separate payment will be made by the Department for the excess usage of materials) -Footing, Plinth beam, Tie beam/Lintel, Ground Floor Roof beam, salbs, Sloped roof beam and slabs 30 V, VI (S5) VII & 13 |
| 9 | BELOW G.L. |
| 10 | Ground Floor |
| 11 | Supplying and fabrication & placing in position Steel Reinforcement using TMT rods for all RCC works as per the design given including cost of steel and binding wire etc., Complete Complying with Std Specification TNSS No. 86 & 86 AV, VI (S3) ( S6 ) VII |
| 12 | BELOW G.L. |
| 13 | Ground Floor |
| 14 | Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9\\"X43/8\\"X 23/4\\" standard specification including finishing, curing,etc., complete complying with standard specification 31 & Similar to 31C V, VI (S5) VII |
| 15 | Plastering in Cement Mortor 1:5 Mix (one part of Cement,, five part of sand)12mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications.TNDSS NO: 56, 57 |
| 16 | Supply and filling of U/S Gravel in layers of not more than 15cm.thick well rammed watered and compacted with surface vibrator, watered and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 17 | Supply and fixing of following Steel Box section including cost of Material conveyance of all material, fabrication and fixing charges etc.Complete as per ISI with rust preventive primer & ready to assemble condition for easy installation at site including dismantling making necessary with power drill to the accessories such as supplying and fixing holdfasts, plastic bush inserts receiver runner bottom shock absorbers etc. and Steel Window Complete as Directed by the Departmental Officer. |
| 18 | Painting the new iron works such as steel doors, Windows,Ventilators windows bars,balustrades etc, in all floor with two coats of best approved first quality and colour of synthetic enamel paint of approved quality, colour and brand (to be approved by executive engineer before use on works ) over one the existing red oxide priming coat in all floors excluding cost of priming coat etc, complete complying with Standard Specification. ( The Make, Quality and colour of paint should be got approved by the engineer in charge before use on works )( TNSS NO or NBC No 61 V VI (54) 3) |
| 19 | Fabricating, Supplying and fixing of per painted Color Galvalum iron sheets with the following specifications, the material shoud be of PPGI tile profile with a red clolour or any other approved design 0.47 mm thick 24 guage having width 1050 mm. The sheet should be G.I. base pre painted hot dipped galvanuzed iron sheet and to be fixed with shelf tappin galvanized iron sheet and to be fixed wth shelf tapping screws plastic washer. the washer and screws to be fixed by using minute power machin drilled with out damaging the sheetspaint coating to be regilar modified polyster coat with zinc coating of Z 120 GSM paint thickness the fininsh optional matt finish. The Sheet to be Fixed with making sutiable Corrugate, Cutting the sheet in to the required size and making ornamental designs as per the site condition and as directed by the departmental officers. |
| 20 | Plain Cement Concrete of mix 1 : 2 : 4 (One part of Cement two part of sand four part of aggregates) using 20mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. TNDSS NO: 28 V, VI (S2) V,VI (S5A) VII |
| 21 | Painting the new plastered walls with two coats of Exterior emulsion paint (weather proof ) first class quality and of approved colour over a priming coat including thorough scrapping clean removal of dirt etc. complete and including necessary plaster paris putty etc. wherever required.as per (ISI STD) (It mustprovide excellent resistance against the growth of algae and fungi on the walls. And it must offer excellent protection against alkali and UV degradation and the durability period should be 5 years. 61 V, VI (S4) 3 |
| 22 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \\"U\\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification..107 V, VI (S1) VII |
| 23 | Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For Electronic regulator). etc, complete as per standard specifications.SD 25 |
| 24 | Supplying and Fixing of single box type 2 x 20 W LED Light fitting complete with Electronic Choke and Teakwood Round blocks on wall or ceiling with fluorescent tube with PVC unsheathed copper leads from terminals to the fitting. [ PWD SOR Page No ; 168 Sl. No : M 1273 ] Please Enable Macros to View BoQ information |