Tender For The Construction Of Health Sub-Centers (Hscs) & Health And Wellness Centers (Hwcs) At Gram Ulau Khera.
Tender Value
35.87 Lakhs
Estimated cost
Bid Submission
09 Jul 2026
5 days left
EMD
71750
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Firozabad → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for The Construction Of Health Sub-Centers (Hscs) & Health And Wellness Centers (Hwcs) At Gram Ulau Khera.
BOQ
| Sl. No. | Item Description |
| 1 | Clearing jungle including uprooting of rank vegetation, grass, brush wood trees and saplings of girth up to 30cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared. |
| 2 | Earth work in excavation by mechanical means (Hydralic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms lift upto 1.5m including getting out the excaveted soil and disposal of surplus excavated soil as directed within a lead of 50m All kind of soil. |
| 3 | Excavating supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20cm in trenches plinth sides of foundation etc complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shutring - All work up to plinth level 1:4:8 (1 cement : 4 coarse sand (zone-III): 8 graded Stone aggregate 40 mm nomial size) including supply of all materials, labour T & P rtc required for proper completion of the work. |
| 5 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate) fifnished with a floating coat of neat cement including cement slurry but excluding the cost of nosing of steps etc. complete 4.0mm thick with 20mm nominal size stone aggregate |
| 6 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 7 | Treatment of sioil under existing floor using chemical emulsion @ one litre per hole, 300mm apart Including drilling 12mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 Coarse sand) to match the existing floor : with chlorpyriphos/Lindane E.C 20% with 1% concentration. |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal siza) |
| 9 | Reinforced cement concrete work in beams suspended , floors roofs having slope upto 15 landings, balconies, shelves, chajjas, lintes, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five levels exluding the cost of centring shutring finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal siza). |
| 10 | Reinforced cement concrete work in wall (any thickness) including attached pilasters buttresses plinth and string courses fillets columns pillars, piers abutments, posts and struts etc. above plinth level up to floor five levels exluding the cost of centring shutring finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal siza). |
| 11 | M-150 brick work in 1:6 cement and coarse sand of 2.25 finess modulus mortar in foundation & plinth including supply of all materials, labour, T & P etc required for proper completion of the work. |
| 12 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proofcourse after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 13 | M-150 brick work in 1:6 cement and coarse sand of 2.25 fineness modulus above but in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of brick work as required and also including honeycomved brick work in thickness of wall more than 12 cms. |
| 14 | Half brick masonary with comman brunt clay (non modular) bricks of class-150 brick work in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for all heights: |
| 16 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 17 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 18 | Suspended floors, roofs, landings, balconies and access platform |
| 19 | Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 20 | Steel reinforcement for RCC work including straightening, cutting bending, placing in position and binding all complete upto plinth level. Thermo-Machenically Treated bars of grade Fe-500D or more |
| 21 | 15mm cement plaster in single coat on rough side of single of half brick wall for interior plastering upto floor two level including internal rounded angles chamfers, and / or rounded angles not exceeding 80mm in girth and finished even and smooth. (1) 1 cement : 6 coarse sand |
| 22 | 12 mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth & finished even & smooth (1) 1 cement : 6 coarse sand |
| 23 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 24 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 25 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of pproved make, in all colours, shades except urgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 26 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut of 225 with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size 600x600mm. |
| 27 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. |
| 28 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement at all levels. mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete.(Granite stone slab of colour black, Cherry/Ruby red, Area of slab over 0.50 sqm) |
| 29 | Supply and fixing of of Polyester Powder Coated aluminium windows having 2 mm thick aluminium section excluding coating & an average coating of 50 micron fully glazed made of aluminium door tube size 83.5 x 44.65 mm as vertical member & 114.00 x 44.45 mm size tube in bottom and horizontal members door chaukhat should be of aluminium tublar vertical with two openable shutters. The rate will include cost of material fixtures, 5mm glass, handles, locks, screw necessary beeding & excluding cost of floor spring if required for proper completion of work as per direction of Engineer I/C. |
| 30 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 31 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm |
| 32 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm |
| 33 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-incharge 150mm x 10 mm (Polyester powder coated minimum thickness 50 micron aluminium) |
| 34 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 35 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
| 36 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge. |
| 37 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 38 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 39 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: With average thickness of 120 mm and minimum thickness at khurra as 65mm. |
| 40 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 41 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 42 | Providing and fixing on wall face unplasticised PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 43 | Coupler |
| 44 | Bend 87.5 ° |
| 45 | Shoe(plain) |
| 46 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 47 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners / stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 48 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without any pigment. |
| 49 | PlumbingProviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. |
| 50 | W.C. pan with ISI marked white plastic seat and lid |
| 51 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 52 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 53 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board |
| 54 | 510X1040mm bowl depth 200 mm |
| 55 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. |
| 56 | Semi rigid pipe |
| 57 | 32 mm dia |
| 58 | 40 mm dia |
| 59 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 60 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for European type W.C. of quality and make as approved by engineer-in-charge. |
| 61 | 15mm nominal bore |
| 62 | Providing and fixing PTMT Liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 63 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, punning, rounding the edges and making and finishing the outlet complete. |
| 64 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 65 | Providing and fixing toilet paper holder : |
| 66 | C.P. brass |
| 67 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc.(internal work)Exposed on wall |
| 68 | 25mm dia nomial bore |
| 69 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. |
| 70 | 25mm dia nomial bore |
| 71 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal Work - Exposed on Wall |
| 72 | 20 mm dia normal outer dia pipes |
| 73 | 25 mm dia normal outer dia pipes |
| 74 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. |
| 75 | 15mm dia nominal outer dia pipes |
| 76 | 20mm dia nominal outer dia pipes |
| 77 | 25mm dia nominal outer dia pipes |
| 78 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. |
| 79 | 15mm nominal bore |
| 80 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 |
| 81 | 15mm nominal bore |
| 82 | Providing & fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 |
| 83 | 15mm nominal bore |
| 84 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality. |
| 85 | 25mm dia nominal bore |
| 86 | 20 mm dia nominal bore |
| 87 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 88 | 25 mm nominal bore |
| 89 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 90 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposal of surplus excavated soil as directed within a lead of 50m. |
| 91 | Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 92 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete |
| 93 | 100mm diameter |
| 94 | 150mm diameter |
| 95 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design |
| 96 | 100mm diameter P.V.C. Pipe |
| 97 | 150mm diameter P.V.C. Pipe |
| 98 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:150 x 100 mm size P type |
| 99 | With Sewer bricks conforming to IS : 4885 |
| 100 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. |
| 101 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 |
| 102 | (i) For Sewere Line |
| 103 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nomial size) as per standard design. |
| 104 | With 20x20 mm square bar |
| 105 | ElectricalWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 106 | Group C |
| 107 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 108 | 2x1.5 sqmm + 1x1.5 sqmm earth wise |
| 109 | 2x2.5 sqmm + 1x2.5 sqmm earth wise |
| 110 | 2x4.0 sqmm + 1x4.0 sqmm earth wise |
| 111 | 2x6.0 sqmm + 1x6.0 sqmm earth wise |
| 112 | Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: |
| 113 | 20 mm |
| 114 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 115 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 116 | 5/6 A switch |
| 117 | 3 pin 5/6 A socket outlet |
| 118 | Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 119 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 120 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 121 | 1 or 2 module (75mm X 75 mm) |
| 122 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connection etc. as required. |
| 123 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connection etc. as required. |
| 124 | Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/wooden block including connection etc. as required. |
| 125 | Supplying and fixing brass batten/angle holder including connection etc. as required. |
| 126 | Installation, testing & commissioning of wall bracket/ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. |
| 127 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 128 | Installation of exhaust fan in the existing opening, including making good the damage, connections, testing, commissioning etc. as required. |
| 129 | upto 450 mm sweep |
| 130 | Extra for fixing the louvers / shutters complete with frame for exhaust fans of all sizes. |
| 131 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, ‘C’ curve including connections, painting etc. as required. |
| 132 | Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 133 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 134 | Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface / recess complete with, tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). |
| 135 | 12 way, Double door |
| 136 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts ‘C’ series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 137 | Single Pole |
| 138 | Double Pole |
| 139 | Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required. |
| 140 | Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 141 | Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.(jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 142 | Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required. |
| 143 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 144 | Upto 35sq. Mm |
| 145 | Supplying & making end termination with brass compression gland and aluminium lugs for the following sizes of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 146 | 2x10 sqmm (19mm) |
| 147 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. |
| 148 | 10 mm Dia |
| 149 | PART-B- NON-SCHEDULED ITEMS (AS PER MARKET RATES)Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. |
| 150 | 10 sqmm 2 core |
| 151 | Supply and erection of 1X10 W mirror light complete in all respects |
| 152 | Supply & fixing of 7/9 W LED BULB complete in all respect. |
| 153 | Supply and fixing of LED Tube Light with batten suitable for up to 1X40 watt LED tube light complete including tube etc. on surface complete in all respect. |
| 154 | Supply & fixing of recess mounting round 15 to 18 watt LED CONCEALED LIGHT having Powder coated die cast aluminium housing with heat sink, diffuser / reflector and driver set complete in all respect. CAT - AAA |
| 155 | Supply of AC 230/250 Volts, 50 Hz 55w 1400 rpm exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required.-Make: Havells-STANDARD - Refresh Air-SPS |
| 156 | 300 mm sweep |
| 157 | Saptic Tank ABSEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge DSR-2.6.1 |
| 158 | From 0.00 mt to 1.50 mt |
| 159 | 1.50 mt to 3.0 mt |
| 160 | 3.0 mt to 4.50 mt |
| 161 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost of form-work, in foundation and floors. |
| 162 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 163 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and accessplatform |
| 164 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 165 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 166 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20 mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 167 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, 20 mm cement plaster |
| 168 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design (With 20x20mm square bar) |
| 169 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 170 | Providing and fixing soil, waste and vent pipes :Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
| 171 | Providing and fixing terminal guard : 75mm Sand cast iron S&S as per IS - 3989 |
| 172 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. |
| 173 | M.D. -10- Circular shape 500mm internal diameter |
| 174 | L.D. -2.5- Circular shape 450mm internal diameter |
| 175 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation M-150. |
| 176 | HAND PUMPProviding and placing in position filters of 40 mm diameter G.I. pipe with -brass strainer of approved quality. |
| 177 | Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well. |
| 178 | Providing and placing in position hand pump of approved quality for 40 mm diameter G.I. pipe complete with all accessories. |
| 179 | BORING & PUMPBoring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. (All types of soil with 300mm dia) |
| 180 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (100 mm nominal size dia) |
| 181 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. ( 100 mm nominal size dia) |
| 182 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. |
| 183 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory,includingdisinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 184 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:(100 mm dia) |
| 185 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).( 100 mm dia) |
| 186 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.( 32 mm dia nominal bore) |
| 187 | Supply and fixing of Armoured cable ISI marked (4sqmm 3core) |
| 188 | Pumping Set KSB make submersible pump set suitable for installation in bore well of min 110 mm inner dia preferably more and having under noted specifications. (1.00H.P) |
| 189 | BoundryWallEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.All kinds of soil |
| 190 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 191 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 192 | Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 193 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 194 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 195 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 196 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 197 | INTERLOCKING TILESEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge DSR-2.6.1 |
| 198 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 199 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 200 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement:12 mm cement plaster |
| 201 | Construction of granular sub-base by providing close graded Materialconforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 |
| 202 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding /laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 203 | DRAIN 150 MM X 150 MMEarth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by engineer in charge. All kinds of soil |
| 204 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 205 | Brick work with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 206 | Cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster |
| 207 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 208 | 3.0 M GATEProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete |
| 209 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 210 | 13.62.1 |
| 211 | Inauguration Stone |
| 212 | Less: 5% Due to work Done by Department |
| 213 | Add: 1% Labour Cess Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 23, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysJul 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender