| 1 | M & L for cement plaster 15 mm thick in cement mortar 1:6 on brick or concrete surfaces finished even and smooth without using extra cement mixed with and including permeability reducing polymer @ 250gm/sqm (6%) by weight of cement at time of mixing with water as per manufacturer's recommendations including all levelling the surface, curing etc including taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc including removal of debrish from the MOD land complete all as specified and as directed.Note : Rates for water proofing compound/ polymer deemed to be included in the above rates. |
| 2 | M &L for applying a bond coat of Latex:Water:cement - 1:4:6 consumption @100 gm/sqm on the brick wall surface by brush as per manufacturer's recommendations including curing complete all as specified and as directed. |
| 3 | M&L for Exposing the first joint of masonry structure at ground level horizontally and knocking off the plaster least 50 cm beyond the visibly penetrated area., scrapping out damaged mortar joints to a depth of approximately 2-3 cm. Drilling holes 10mm diameter in masonary structure along the side of the joint as per manufacturer's instructions so as to cross the brick/ block at the intervals spacing of 15-30cm depending on extent of rising dampness as per recommendation of engineer in charge. Cleaning of holes by air blower prior to fixing nozzles, installation of latex polymer packer injection packers 9.8mm diameter, 10cm long in the holes and tighten, Fixing the packer securely using sealent and Cutting/removing of Packers after completion of grouting/injecting without damaging structural elements |
| 4 | Supplying and application of very low viscous, elastic polyacrylic injection resin with a versatile and adjustable reaction time, having mixed viscosity 3 to 11 m.Pa.s at 20 Deg C, reaction time adjustable according to ambient temperature and execution time requirement between 8-50 mins, the polyacrylic resin is pumped into the wall through packers injection at a pressure > 20 Bar into or behind fissures or into masonry joint which are allowing water to infiltrate into unwanted areas cause rising dampness. When polyacrylic resin movement stops or polymer compound appears at the packer, move to the next packers and inject (Approx 0.2-0.3 Kg resin per packer).Make : SIKA/FOSROC/BASF |
| 5 | M&L for Chequered cement concrete tiles with grey cement and pigment 25 cm x 25cm x 22-25 mm thick set & jointed and pointed in cement slurry to match over and including 15 mm thick screed bed in cement mortar 1:6 on plinth protection including 50 mm thick cement concrete 1:3:6 type C2 using 20 mm graded crushed stone aggregate as in plinth protection, laid to slope of 1 in 24 in alternate basis system, without, each bay shall not exceed 3 m in length, 12mm wide joint & 50mm deep joint shall be formed between the bays which shall be filled with Mastic filling to full depth comprising a mixture of 1 part of heater hot blow bitumen 85/25 portion and two parts of heated Badarpur sand (by volume) complete all as specified and as directed. |
| 6 | M&L for preparation of newly plastered surfaces of wall/ceiling sufraces and applying 1mm thick (average thickness) waterproof cement based putty and thereafter apply two coats of Green pro certified water-based, modified acrylic, exterior Apex suprema emulsion or equivalent as per required shade (compound depot tinted) with silicon additives, heat reflecant property, VOC less than 2 % by mass, class A IS 15489 and IS-101@ 5.-6 Sqm/ltr with Graco-490 spray machine over a coat of primer and using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 Mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by painT manufacturer complete all as specified and as directed. Notes:- Applicable to srl item No 1.00 to 6.00 (a) The smart periodical work under this contract shall be executed by manufacturers authorized applicator after approval of name of manufacturar's by GE. (b) The contractor shall produce the name brandof material and it manufacurar's within 10 days from the date of award of tender. After approval of paint manufracturer and product brand, the contractor shall produce a \\"Memorandum of Understanding\\" (MoU) between contractor, applicator and the manufacturer within 28 days from the award of of tender date or before commencement date of work. wherein the manufacturer shall own the responsibility of use premium quality products in adequate quality and workmanship. The Contractor shall also produce purchase Vouchers/Invoice for all product/materialutilised in work for their full quantity and Engineer-in-charge shall ensure to kept in record duly defaced & verified. |
| 7 | (c) Sanding of surfaces shall be carried out by mechanical sander having speed 1500–2700 RPM with internal dust extraction system to maintain clean environment and certified by paint manufacturer.(d) Electrical fittings such as tube lights, bed lights, switch boards etc. shall be carefully taken down before commencement of painting work and refixed after completion of painting work.(e) Furnitures in the quarters shall be shifted and stored in one room before commencement of painting work and rearranged to original position after completion of work.(f) Entire quarters including flooring, doors and windows shall be cleaned by the contractor after completion of painting work.(g) The rates quoted by the tenderer shall be deemed to include all the above provisions and nothing extra shall be paid on this account. |
| 8 | M&L for providing and injecting chemical emulsifiable concentrate for post constructional Anti termite treatment along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litre per linear meter including drilling and plugging holes etc in apron complete all as specified and as directed. |
| 9 | Taking down chowkats with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames), complete all as specified and directed by engineer-in-charge. |
| 10 | Supply fabricating and fixing of Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be mooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge |
| 11 | Supply fabricating and fixing of Powder coated aluminium (minimum thickness of powder coating 50 micron) work for shutters of doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be mooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge |
| 12 | S&F 5.0 mm thick plain sheet glass of seleted quality fiixed into aluminum door/partition with aluminum beading and rubber gasket etc complete all as specifed and as directed. |
| 13 | S&F ACP sheet 4 mm thick of any colour, fixed with aluminium beading in aluminum window/ventilator etc complete all as specifed and as directed. |
| 14 | S&F Stainless steel wire cloth, 0.63 mm nominal dia of wire and average width of perature 1.40 mm and fixed with SS wire staples in door/windows and similar work all as specified and as directed. |
| 15 | S&F 5.0 mm thick frosted/pin head sheet glass not excedding 0.5 sqm each pane of seleted quality fiixed into aluminum door/partition with aluminum beading and rubber gasket etc complete all as specifed and as directed. |
| 16 | Excavation in post holes in hard / dense soils , each not exceeding 0.50 cum, getting out, returning filling in and ramming earth in layers not exceeding 25 cm including watering & removing surplus soil to a distance not exc. 50m & making good surface complete all as specified and as directed |
| 17 | M&L for cement concrete (1:3:6) Type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. |
| 18 | M&L for mild steel for framed work as in doors, gates of angle Fe-410 gde E 250 section with gusset plates complete drilled or welded to be prepared for hanging or sliding with and including either hooks and hinges complete all as specified and directed. |
| 19 | S&F 4 mm thick fibre glass reinforced translucent plain sheeting of any colour and pattern fixed with coach screw and washer in wall , complete as specifed and as directed. |
| 20 | M&L for preparation of new steel surfaces of any description , not itherwise described , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zink chrome primer including, complete all as specified and as directed. |
| 21 | Cutting holes in brick walls in built in cement mortar or cement lime mortar exc half brick but not exc one brick complete alll as specified and as directed. |
| 22 | Cutting chases ,pinning in , making good to facings where required and pointing in cement mortar 1:3 to ends or edges or landings, steps, cills, sunshades,shelves,lintel,etc and cutting in chases for concealed conduit wiring, etc and making good, cutting not exceeding 10 cm girth complete alll as specified and as directed. |
| 23 | M&L for mild steel work in tubular trusses including special shaped washer, cleats etc complete using ERW or induction butt welded tubes confirming to IS: 1161-1979 grade st - 240 complete all as specified and as directed. |
| 24 | S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 25 | S&F Structural Steel in roof, purlins crane of angle or other section gusset plates, Flat Iron rails braces etc, drilled for fixing, and other covering r etc to be prepared for hanging and sliding with and including either hooks and hinges and other covering running rails and guides and hanging also fastening and fixing complete. Fe- 410 Grade E-250 quality -B-l complete all as specified and as directed. |
| 26 | M&L for cement Concrete Type B-1 1:2:4 ( 20 mm graded crushed stone aggregate) as in roof Kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed. |
| 27 | Surface dressing not exceeding 15 cm deep in any type of soil complete all as specified and as directed. |
| 28 | M&L for 100 mm thick cement concrete (1:4:8) Type D-2, (40 mm graded crushed stone aggregate), as in sub-base of floor and similar works complete all as specified and as directed. |
| 29 | M&L for cement concrete type B-1, 1:2:4 using 20 mm graded stone aggregate as in holdfasts, coping on edges etc including weathering slightly rounded or chamfered angles and throating as directed including necessary formwork complete all as specified and as directed. |
| 30 | M&L for 60 mm thickness, M-35 grade machine pressed precast concrete interlocking paver block of any colour, any shape and size confirming to IS 15658-2006, laid over and including 50 mm laid sand cusioning complete all as specified and as directed. |
| 31 | Supply and fixing false ceiling at sufficent heights with GRG (Glass Fibre With Semi With fully Reinforced Gypsum) false ceiling tiles 12 mm thick fully perforated micro tegular design of size 595 x 595 mm of approved texture and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS tiles tiles 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000 mm, cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws complete all as specified and as directed. |
| 32 | S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) Plain Board of required size for WC/Bathroom/Toilet/Kitchen & Cabinets comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural Fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with density not less than 650 kg/cbm Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof, Fire Retardant and fixing with stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws including dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed. |
| 33 | S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) laminated Board of required size for WC/Bathroom/Toilet/Kitchen & Cabinets comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural Fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with density not less than 650 kg/cbm Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof, Fire Retardant and fixing with stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws including dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed. |
| 34 | S&F Magnetic catch for wooden cupbord with complete closer macanigum claps and clips fix with stainless steel screw complete all as specified and as directed. |
| 35 | S & F U shaped double stainless steel channel of size 10 mmX 20mm X 1.5 mm fixed to wooden frame including suitable rail rollers etc complete all as specified and as directed. |
| 36 | S&F 40/50 mm dia cup board knobs fixed with nut, screws and washers of aluminium, anodised complete all as specified and as directed. |
| 37 | S & F 75 mm long concealed type hydraulic hinges including stainless screw complete all as specified and as directed. Please Enable Macros to View BoQ information |