Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | EARTHWORK: Cutting earth work . in all heights and depth etc. in all kinds of soils including , saturated soil comprising of ,pick work, jumper work, blasting work both in soft and hard rock with chiselling and wedging outof rock ( where blasting is prohibted) and there intermediate classification of soils including dewatering whereever required, setting out to required lines, levells as shown on the drawing and direted by the Engineer-in-Charge at site, according to the PWD specification of 1990 ( One thousand nine hundered ninety) volume-I ( one) and sorting out useful and unuseful materials and transportation of the useful materials for disposing at dumping site ( to be arranged by the contractor) as per satisfication of Engineer-in- Charge through all modes of transportations including head load, animal load or mechanical means along with levelling fine dressing and with all kinds of labour , machineries, tool equipments and safety measures and incidents necessary to complete the work by mechanical means and labour (if required). All useful materialsuch as stones, shingles, aggregatesand slates shall be properlystacked at site to the maximum possible extent in all leads and lifts through all modes of transportation as per the direction of the Engineer-in-Charge. and all surplus excavated earth will be disposed off at approved dumping site which will be arranged by the contractor at his own cost. Any loss to the public and private property during the course of execution and disposal of serviceable and unserviceable materials shall be the absolute responsiblity of the contractor and shall have to be dully compensated by him in all respects including all incidental charges. |
| 2 | Earth Work:- Earth work in foundation by mechanical means (Hydraulic excavator)/ manual means in all heights and depths in all kinds of soil including saturated soils comprising of pick work, jumper work and blasting work both in soft and hard rock with chiesling and wedging out of rock (where blasting is prohibited and their intermediate classifications soils including dewatering where ever required, setting out to required lines, levels as shown on the drawing and directed by the Engineer-in-charge at site, according to the CPWD specification and sorting out useful and unuseful material and transportation of the unuseful material for disposing at dumping site including prescribed dumping charges (to be arranged by the contractor out of MC area) to the satisfaction of Engineer-in-Charge through all modes of transportation including head load, animal load or mechanical means along with its leveling fine dressing and with all kinds of labour machineries, tools equipments and safety measures and incidentals necessary to complete the work wise mechanical means and labour (if required) all useful material such as stones,shingles aggregate and slates shall be properly stacked at site to the meximum possible extent in all leads and lifts through all modes of transportation and used/removed as per the direction of Engineer-in-charge. Any loss to the public and private property during the course of execution and disposal of serviceable and unserviceable materials shall be the absolute responsibility of the contractor and shall have to be duly compensated by him in all respect including all incidental charges:- :- All kinds of soil. |
| 3 | FORM WORK :-Centering and shuttering including strutting, propping etc. and removal of form for upto all floor levels including carriage of materials in all leads and lifts:-(i) Foundations, footings, bases of columns, etc. for mass concrete. |
| 4 | (iii) Columns, Pillars, Piers, Abutments, Post and struts. including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 5 | (iv) Lintels, beams, plinth beams, girders,bressumers and cantilevers. including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 6 | (ii) Suspended floors, roofs and the like. including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 7 | (v)Stairs, (excluding landings) except spiral-staircases.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 8 | (vi) Edges of slabs and breaks in floors and walls.(a) Under 20 cm wide Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 9 | (vii) Walls any thickness including attached pillasters, buttresses, plinth and string courses etc. Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 10 | (viii) Small lintels of any span,moulding as in cornices,window sills, string courses, bands, copings, bed plates, anchor blocks and the like.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 11 | CONCRETE WORK: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :- In C.Conc.1:4:8 (one Cement : four coarse sand : eight graded stone aggregate forty milimetre nominal size) upto all height/ lift Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :In 1:5:10 (one cement : five coarse sand : ten graded stone aggregate forty milimetre nominal Size) up to all height /lifts Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :- In Cement Concrete 1:2:4 (one cement : two fine sand : four graded stone aggregate 20 mm (twenty milimetres) nominal size) Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 14 | R.C.C WORK: Providing and laying in position specified grade of reinforced cement concrete M 25 design mix , excluding the cost of centering, shuttering, finishing and reinforcement :- (i) All work up to plinth level Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge.. |
| 15 | Reinforced cement concrete work design mix M-30 in beams, suspended floors, roofs having slope up to 15° landings, balconies,shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to all floor levels, excluding the cost of centering,shuttering, finishing including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 16 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses,plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement ( M-30) design mix upto all floor levels including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 17 | Providing and laying cement concrete in 1:3:6 (1 cement :3 sand:6 stone aggregate 20 mm nominal size) in Retaining walls Return walls, B/walls any thcikness including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 18 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand) : 4 graded stone aggregate 20 mm nominal size)Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 19 | Providing & Applying Water proofing treatment with Dr. Fixit - FASTFLEX or equivalent with two components polymer modified cementious coating consisting of cementious powder and a polymer liquid in two coats for first coat : clean and saturate surface and then applying a coat of Dr. FAST FLEX by maintenaning a coverage of 6-7 sft. per kg to achieve one mm thickness andthe same process shall ended upto 300 mm vertically. The second coat shall be applied in apposit direction after four six hours of application of first coat then sprinkle sand on top surface of applied Dr. Fixit- FASTFLEX while still tacky over the second coat. Then apply cement mortar 1:4 ( 1 cement:4 sand) admixed with 200 mL of pidiproof LW @ 200 Ml per 50 kg bag of cement over the floor with the suitable gredient towards drain pipe, while the second coat of Dr. Fixit is still tacky Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 20 | Steel reinforcement for R.C.C. work including straightening cutting, bending, placing in position and bindig all complete including cost of binding wires etc. upto all floor levels including carriage of materials in all leads and lifts. (i) Thermo-Mechanically Treated bars of grade i.Fe-500D or more Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 21 | BRICK WORK: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in :- foundation and plinth in:(i) Cement mortar 1:6 ( one cement : six coarse sand) including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 22 | MASONARY WORK:Providing and laying 23 cm thick brick masonry/ Rat trap bond with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure in ce,ent mortar 1 ratio 6 above plinth level up to floor all levels. |
| 23 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level upto all floor levels including carriage of materials in all leads and lifts.(i) In Cement mortar 1:4 (one cement : four coarse sand) |
| 24 | STONE WORK:- Stone soling properly hand-packed filling interstices with Kharanja stone under floor specified thickness complete as per HP.PWD specification including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 25 | Stone filling behind retaining wall per HP.PWD specification 1990 Volume-I Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 26 | Providing weep holes in brick masonry / stone masonry /plain reinforced concrete abutment, wing wall, return wall with 100 mm (one hundred milimetre) dia PVC pipe extending through the full width of the structures with slope of 1(v):20 (H) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7 Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 27 | Random rubble masonry/polygonal rubble masonry (uncoursed/brought to courses) with hard stones of approved quality in R/walls and Breast wal including leveling up with cement concrete 1:6:12 (1 cement :6 sand : 12 graded stone aggregate 20mm nominal size) at plinth level in Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 28 | STEEL WORK:Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.(i) Fixed to steel windows by welding including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 29 | Structural steel work riveted, bolted or welded in built up sections or in hollow section in , trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 30 | Steel work welded in built up sections/ hollow section in framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required upto all floor levels including carriage of materials in all leads and lifts by mechanical or manual means: (a)In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 31 | Providing and fixing 50 mm x50 mm section hand rail round end at two levels as per Architectural drawing complete of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer including carriage of materials in all leads and lifts by mechanical or manual means. |
| 32 | Providing and fixing 50 mm dia S.S pipe hand rail slip resistent with round end at two levels at 75 and 90 cm height as per Approved Architectural drawings and design complete upto all floor levels including carriage of materials in all leads and lifts by mechanical or manual means. |
| 33 | P/F M.S Suspender of required size and shape to hold waste water pipes to be fixed with self drilling screws / fastners over existing RCC ceiling as per the direction of Engineer-in- Charge including carriage of materials in all leads and lifts.. |
| 34 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including carriage of materials in all leads and lifts by mechanical or manual means. |
| 35 | Providing and fixing 2 mm thick Aluminium sheet lining in Shutters with necessary screws/ nails etc. complete upto all floor levels Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 36 | Providing and fixing KICH PR make A/S/316 grade stainless steel modular railing system comprising 50 mm dia hand rail fixed on 10x50 mm S.S flat Baluster ( Design code DS 54-2-G10) (including top bracket tohold hand railing) , placed at maximum 1200 mm C/C connected with balusters . The balusters would be fixed to side of steps with base plate of minimum 8 mm thickness ( 100x100x8 mm base SS 304 grade base plate). Wall thickness of all pipes shall be taken as 1.5 mm thick alongwith all visible component developed in high grade SS railing height to be taken @ 110 mm or as per Architectural drawing / sample from floor level at all floor levels including carriage of materials in all leads and lifts by mechanical or manual means. |
| 37 | WOOD WORK:- Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). (i) Second class Deodar wood |
| 38 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge including carriage of materials in all leads and lifts: 2nd class Deodar wood (i) 40 mm thick. |
| 39 | Providing and fixing door shutter infill panels only (below lock rail) with 12 mm thick Phenol bonded ( both sides) Prelaminated BWP Grade MDF board in Matt Finish ISI marked IS No. 12823 of Action Tesa / GREEN LAM /MERINOLAM /KITLAM /VISTA as per approved shade/ sample by Engineer-in- Charge / Architect glazing in doors, ventilators etc as per approved drawing complete in all respect ( Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) including carriage of materials in all leads and lifts. |
| 40 | Providing and fixing ISI marked Factory made Flush Doors shutter of Commercial board i.e non decorative Phenol bonded termite resistant & water proof core of block board construction with full frame of first class hard wood and well match of flush door shutters conforming to Alpro / Century I.S.I marked IS : 2202 (Part I)to be painted (i) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws including carriage of materials in all leads and lifts. |
| 41 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 21 mm thick ( 5+10+6 mm) reflective glass panes including required beading etc. complete, including ISI marked S.S. pressed butt hinges bright finished of required size with necessary screws Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. (i) Second class Deodar wood. (i) 40mm thick |
| 42 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : (i) 35 mm thick shutters. with ISI marked M.S. pressed butt hinges bright finished of required size. (i) Second class Deodar wood Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 43 | Providing and fixing using 21 mm thick ( 5+10+6 mm) reflective glass panes Glass Panels in fixed window portions with wooden beading of required size with nails etc. complete in all respect (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). (i) 21.0 mm thick glass panes ( In Fixed shutters) Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 44 | Providing built up UPVC casement windows profile specifications:- Zendoe series: Outer frame - 12601 ( 70 mm x64 mm), Sash-12617 ( 70 mmx70 mm) Z Mullion - 3086 ( 70 mm x 50 mm), Coupling - 12358 ( 70mm ) including shutters with chember thickness 2.60 mm and GI frame thickness 1.20 to 2.00 mm and 6 mm + 12 mm +6 mm DGU toughned glass gap filled with argon gas fixed with thermoplastic elastomer (TPE) gasket including Zinc alloy casement handle, Friction Stay / 2 D hinges/ butt hinges, espag multipoint locking system, locking strickers complete in all leads and lifts including carriage of materials and as per the direction of the Engineer-in- Charge. |
| 45 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : (i) For fixed portion. Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 46 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws,and including cloth wire as per architectural detail all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : (i) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 47 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With KT series toughened glass panes of 6 mm thickness weight not less than 20.00 kg / sqm With KT series toughened glass panes of 6 mm thickness weight not less than 20.00 kg / sqm |
| 48 | 4 mm glass panes Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 49 | FITTINGS: Providing and fixing C.P steel sliding door bolts, ISI marked , with nuts and screws etc. Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge.. : (i) 300x16 mm |
| 50 | (ii) 250x16 mm Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 51 | Providing and fixing C.P steel tower bolts, ISI marked, , with necessary screws etc. complete :(i) 200x10 mm |
| 52 | (ii) 100x10 mm including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 53 | Providing and fixing C.P Steel handles, ISI marked, required colour or shade, with necessary screws etc. complete (ii) 125 mm including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 54 | (ii) 100 mm including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 55 | Providing and fixing C.P Steel hanging floor door stopper, ISI marked, , with necessary screws etc. complete. Twin rubber stopper including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 56 | Providing and fixing C.P Steel die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight up to 35 kg and door width up to 700 mm), with necessary accessories and screws etc.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 57 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge..( 255 X 19 mm)i) 100 mm |
| 58 | Providing and fixing water proof plywood kit ply (gold) or equivalent lining including mitring at junctions, butt jointing and nails complete (Frame work for base to be measured & paid for separately) 6 mm thick including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 59 | Providing and fixing 19mm thick water proof HDMR Board/ ply (gold) board or equivalent in shelves/box for cup board with butt joints & fixing with nails & screws etc complete) including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 60 | Providing and fixing 19mm thick HDMR Board kit ply (gold) board or equivalent water proof shutters for Cup boards i/c fixing with nickel plated piano hinges with screws etc complete) Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 61 | Providing and fixing square edges cover fillets (beading) 19mmx6mm section i/c mitring at junctions with wood screws and nails complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge.(i) 1st class indian teak wood. |
| 62 | Providing and fixing 65mm X 35mm special quality bright finished brass cup board lock with six levers including necessary screws etc. complete (Godrej make or equivalent of approved quality) including carriage of materials within all leads and lifts. |
| 63 | Providing and fixing C.P Brass approved make furniture handles fixed with screws etc Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 64 | Providing and fixing magnetic catcher (M-15)Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 65 | Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 66 | Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by with stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately) including carriage of materials in all leads and lifts. |
| 67 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position including carriage of material within all leads and lifts as per direction of Engineer-in-charge. : (i) Kail wood |
| 68 | Providing and fixing 1 mm thick lamination sheet marked no. 12823 of approved shade of and sample and quality of Kit Vista of Kit ply or its equivlent fixed with approved adhesive and nails Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 69 | Providing and fixing chromium plated brass curtain rod having wall thick 25 mm dianess of 1.25mm with two chromium plated brass brackets and finals etc. complete fixed with C.P. Brass screws and PVC sleeves etc., whereever required in all respect up all floor levels including carriage of materials in all leads and lifts.(i) 25 mm dia |
| 70 | FLOORING: -Providing and laying 25 mm thick factory made cement concrete interlocking paver block of M -50 grade made by block making machinewith strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 71 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.(i) Zebra black Grainte. |
| 72 | Providing and laying Pre- Laminated H.D.F Flooring including skirting if required of AC5, 12 mm thick of Armstrong Ambience Crystal including skirting of approved make and sample inclusive its required polyfill sub base complete in all respect including carriage of materials in all leads and lifts. |
| 73 | Providing and fixing 1st quality ceramic glazed tiles of size 300 mmx 600 mm as approved by the Engineer-in- Charge conforming to IS : 15622 (thickness to be specified by the manufacturer ) of Restile/ Nitco/ Simpolo/Kazaria/ Somany/ Johnson/ Bell/ Orient/ AGL or its equivlant make and shades as approved by Engineer-in-Charge in skirting, risers of steps and dados without border over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete including carriage of materials in all leads and lifts. |
| 74 | Providing and laying Polished Baroda Green Marble stone slab single piece in risers, skirting and dado, in linear as well as curvilinear portions of the building all complete as per the Architectural drawings with 19 mm ( ninteen milimetres) thick stone slab over 20 mm (average) thick base of cement mortar 1:4(one cement : four coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing ,curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge up all floor levels including carriage of materials in all leads and lifts.(i) 19 mm ( nineteen milimetrs) thick. |
| 75 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.(i)White marble with grey streaks. as directed by the Engineer-in-Charge up all floor levels including carriage of materials in all leads and lifts.(i) 19 mm ( nineteen milimetrs) thick. |
| 76 | Extra for pre finished double nosing in treads of steps of granite/ Kota stone/ sand stone slab. |
| 77 | Providing and laying flooring with 1st quality full body non slipery Matt finish Double Charged vetrified floor tiles of size 600x1200 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown,of Orient, Bell/ Kazaria/RAK/Somany or its equivelent make of approved shade & sample by the Engineer-in- Charge in floor laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 78 | Providing and laying flooring with 1st quality full body non slipery Matt finish Double Charged vetrified floor tiles of size 600x600 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown,of Orient, Bell/ Kazaria/RAK/Somany or its equivelent make of approved shade & sample by the Engineer-in- Charge in floor laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 79 | Providing and laying Ceramic floor tile non slipery Matt finish vetrified floor tiles of size 300x300 mm /400x400 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown,of Orient, Bell/ Kaza-ria/RAK/Somany or its equivelent make of approved shade & sample by the Engineer-in- Charge in floor laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 80 | Providing and fixing 1st quality ceramic glazed tiles of size 600 mmx 1200 mm as approved by the Engineer-in- Charge conforming to IS : 15622 (thickness to be specified by the manufacturer ) of Restile/ Nitco/ Simpolo/Kazaria/ Somany/ Johnson/ Bell/ Orient/ AGL or its equivlant make and shades as approved by Engineer-in-Charge in skirting, risers of steps and dados finished in line of plaster having 12 mm groove in between with or without border over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete including carriage of materials in all leads and lifts. |
| 81 | Providing and fixing 1st quality ceramic glazed tiles of size 600 mmx 600 mm as approved by the Engineer-in- Charge conforming to IS : 15622 (thickness to be specified by the manufacturer ) of Restile/ Nitco/ Simpolo/Kazaria/ Somany/ Johnson/ Bell/ Orient/ AGL or its equivlant make and shades as approved by Engineer-in-Charge in skirting, risers of steps and dados without border over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete including carriage of materials in all leads and lifts. |
| 82 | P/L Cement concrete flooring / skirting in 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.(i) 40 mm thick with 20 mm nominal size stone aggregate Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 83 | Providing and laying Granite Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.8mm thick Granite tiles or as approved by the Engineer-in- Charge.Granite of any colour and shade |
| 84 | Providing and laying 1st quality full body non slipery stepping stone Matt finish Double Charged vetrified stair step single piece tiles of required size (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown,of Orient, Bell/ Kazaria/RAK/Somany or its equivelent make of approved shade & sample by the Engineer-in- Charge in floor laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 85 | 40 mm thick fine dressed red stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. |
| 86 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M -50 grade made by block making machinewith strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 87 | ROOFING: Providing and fixing Pre-painted sand wich Puff insulated sandwich panel roofing having top profile sheet with 28-30 mm crust hight at 195-200 mm pitch, inner liner tray and puf insulation between not less than 50 mm thick and width 980 mm, panel shall be 0.50 mm thick precoated gI sheet sheet on both side of polyurethane foam confirming to IS 12436:1988 with standard profile with tongue & groove arrangement, puff having minimum density of 40 kg/cum(+-2 kgs) over steel trusses including vertical / curved surface fixed with polymer coated J or L hooks,or self screws, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required and as directed by the Engineer-in-Charge upto all floor levels including carriage of materials in all leads and lifts. |
| 88 | Providing and fixing 0.60mm thick preprinted steel sheet (TATA Durashine) in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyester (RNP) organic coating of 20microns over 5microns primer coating to back coat of polyester of 5microns over 5microns primer coating including fixing with self drilling screws complete with preprinted limpet and rubber washers complete with all accessories as required as per the direction of Engineer-in-charge including carriage of materials up to all leads and lifts |
| 89 | Providing and fixing Factory made ridges or hips ornamental or plain as per approved Architect Drawing, of width 60 cm overall width plain Prepainted G.S. sheet ( Tata Duroshine) fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/m² white cement slurry admixed with pigment of matching shade including rubbing ,curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge upto all floor levels including carriage of materials in all leads and lifts. |
| 90 | Providing and fixing of 90 cm overall width valley plain Pre-painted G.S. sheet of Tata make or its equivlent fixed with polymer coated J or L hooks, bolts and nuts, G.l. limpet and bitumen washer complete, bent to shape and fixed in wall with cement mortar 1:3 (1 cement : 3 coarse sand). 1.00 mm thick with zinc coating not less than 275 gm/m² including carriage of materials up to all leads and lifts. |
| 91 | Providing and fixing pre-painted plain steel sheet (TATA MAKE or its equivlent as approved by the Engineer) fixing 30 cm wide, 30 cm deep overall semicircular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers or self drilling screws etc., including making necessary connections with rain water pipes complete up all heights/ level including cost of scafolding and carriage of materials in all leads and lifts.(a) 0.60 mm thick with zinc coating sheet with top coat of regular modified polyster (RMP) organic coating of 20 microns primer of 20 micron over microns pruner+ back coat of polyster of 5 microns primer coating including carriage of materials up to all leads and lifts. |
| 92 | Providing and fixing of 0.60 mm thick prepainted steel sheet of Tata make or its equivlent 40 cm overall Flashing fixed with polymer coated J or L hooks, bolts and nuts, G.l. limpet and bitumen washer complete, bent to shape and fixed in wall with cement mortar 1:3 ( 1 cement : 3 sand) including carriage of materials up to all leads and lifts. |
| 93 | Providing and fixing MS BP sheet 2.00 mm thick in eves board /fascia/ soffits/ ceiling including cutting fixing and welding to steel roof members and applying a coat of red lead primer complete as per the instruction of Engineer-in-charge ( base members of steel work shall be measured and paid separately ) including carriage of materials up to all leads and lifts. |
| 94 | Providing & fixing false ceiling at all heights with ACP sheet 3 mm thick in parrelel to the existing sloping roofing of required Size texture, design and patterns/ colour as approved by the Architect , to be suspended on inter-locking Aluminium Tublar Grid of 1.20 mtr.x0.90 mtr. with Aluminium section of size 50x25 mm having 1.628 mm thick including fixing the frame with Aluminium cleat angle of 40 mm fixed with self drilling screw of required size. THe joints of sheets will be mitred with silicon/ weather sealant of rquired colour including carriage of material in all leads and lifts. |
| 95 | Providing and fixing on wall face PVC rain water pipe for rain water pipes including accesories ,bends etc. if reuired and jointing , complete in all respect etc.:- 100 mm dia. |
| 96 | (ii) 75 mm dia.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 97 | Providing and fixing M.S. flat 20x5 mm clamps of approved design to C.I. or S.C.I. or PVC rain water pipes embedded with sef screws / fastners in wall and making good the walls etc.including carriage of materials in all leads and lifts.: 100 mm dia. |
| 98 | (ii) 75 mm dia. including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 99 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion:-Single pushfit Coupler 100 mm dia |
| 100 | (ii) 75 mm dia including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 101 | (b) Single Tee without door 100 mm dia including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 102 | (ii) 75 mm dia including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 103 | (c) Bend 100 mm dia including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 104 | (ii) 75 mm dia including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 105 | (d) Shoe (Plain) 100 mm dia including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 106 | (ii) 75 mm dia including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 107 | FINISHING: 6 mm Plaster in Ceiling 1:3 (1 cement : 3 fine sand) upto all floor levels and heights including carriage of materials in all leads and lifts. |
| 108 | 15 mm cement plaster on the fair side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand) upto all floor levels and heights Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 109 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand) upto all floor levels and heights Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 110 | 15 mm cement plaster in pattern on the rough side on brick wall of mix :1:4 (1 cement: 4 fine sand) with plaster bands / designs as per Architectural drawing upto all floor levels and heights including carriage of materials in all leads and lifts. |
| 111 | PAINT WORK:- Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Two coats or as directed by the Engineer-in-Charge upto all floor levels including carriage of materials in all leads and lifts. |
| 112 | Finishing walls with 100% Premium acrylic emulsion Apex paint having VOC less than 50 gm/liter and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 liter/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 liter/10 sqm (Circulation area) |
| 113 | Distempering with Acrylic oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including water thinnable priming coat with cement primer upto all floor levels and heights including carriage of materials in all leads and lifts. |
| 114 | Finishing walls with Premium acrylic emulsion having VOC less than 50 gm/liter and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 liter/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 liter/10 sqm |
| 115 | Finishing with Deluxe Multi surface paint system for interiors and exteriors including using Primer as per manufacturers specifications :--Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 116 | Finishing with Deluxe Multi surface paint system for interiors and exteriors including using Primer as per manufacturers specifications :-- Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 117 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry stone/brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, leveling & dressing & finishing the top smooth |
| 118 | Providing, laying and jointing glazed stoneware half round pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete over base concrete which will be paid separately) including carriage of materials in all leads and lifts by mechanical or manual means:(i) 250 mm radius. |
| 119 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. |
| 120 | Providing and laying 19 mm thick mirror polished kota stone 50x50 cm of required size (thickness to be specified by the manufacturer) by the Engineer-in- Charge in floor , laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 121 | Providing and laying 19 mm thick mirror polished kota stone 50x50 cm of required size (thickness to be specified by the manufacturer) Skirting laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 122 | Melamine polishing on new wood works / ply including multy coats of wood filler, sealer complete to the satisfication of Engineer-in- Charge including carriage of materials in all leads and lifts. |
| 123 | Providing and fixiung in position pre-cast RCC manhole cover and frame of required shape and approved quality (i) Rectangular shape 600x450 mm internal dimensiions including carriage of materials in all leads and lifts. |
| 124 | Providing and fixing pipes on wall face PVC Finolex type-B spigot,socket, waste and ventilating pipes of working pressure not less than 4.5 kg/sqm of Finolex or equivelent including coller and filling the joints with approved adhesive complete including carriage of materials within all leads and lifts.:- 150 mm dia. |
| 125 | (ii) 100 mm dia.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 126 | (iii) 75 mm dia.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 127 | Providing and fixing G.I. pipes medium grade Jindal, Tata or equivelent make complete with G.I. fittings including trenching and refilling etc. or on wall Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge.t:- External work (i) 20 mm dia nominal bore |
| 128 | Providing and fixing G.I. pipes medium grade Jindal, Tata or equivelent make complete with G.I. fittings including trenching and refilling etc. .including carriage of materials within all leads and lift:- External work (ii) 15 mm dia nominal bore |
| 129 | Providing and fixing Polyethelene-Aluminium- Polyethelene PE-AL-PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge. (i) Concealed work, including cutting chases and making good the wall etc.(i) 1216 (16 mm OD) pipe |
| 130 | (ii) 1620 (20 mm OD) pipe. |
| 131 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete including carriage of materials within all leads and lift. :(i) 25 to 40 mm nominal bore |
| 132 | Providing and fixing Water Meter bulk Type of approved make and dully tested from approved lab. Including carriage of materials in all leads and lifts.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 133 | Providing and fixing cromium plated brass stop cock of ISI marked of Jal or ESS or its equivlent approved quality including carriage of materials within all leads and lift: (i) 15 mm nominal bore |
| 134 | Providing and fixing gun metal gate valve with C.I. Wheel of approved quality (screwed end) including carriage of materials within all leads and lift. (i) 20 mm nominal bore |
| 135 | (i) 15 mm nominal bore Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 136 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ( Superior Quality and make as approved by Engineer-in- Charge) IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank including carriage of materials within all leads and lift. |
| 137 | Providing and fixing angle/ball valve (brass) of Jal or ESS or approved quality, High or low pressure, with plastic floats complete including carriage of materials within all leads and lift. 20 mm nominal bore |
| 138 | (ii) 15 mm nominal bore Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 139 | Providing and fixing white vitreous china pedestal type water closet (European type Seat Floor mounted 82x38x70 cm no.20032 in white shade of Somany/Cera/ Hindware or its equivlent with seat and lid, 10 litre low level white P.V.C. flushing cistern,including flush pipe, with manually controlled device (handle lever),conforming to IS : 7231, with all fittings and fixtures complete, includingcutting and making good the walls and floors wherever required .(i) W.C. pan with ISI marked white solid plastic seat and lid including carriage of materials within all leads and lift.(i) W.C. pan with ISI marked white solid plastic seat and lid including carriage of materials within all leads and lift. |
| 140 | Providing and fixing single unit floor mounted 670x370x795 mm in white shade vitreous china pedestal type water closet (European type Seat No. 20032 of Hindware / Cera or equivelents in white shade with seat and lid, 10 litre low level white P.V.C. flushing cistern,including flush pipe, with manually controlled device (handle lever),conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required .(i) W.C. pan with ISI marked white solid plastic seat and lid including carriage of materials within all leads and lift. |
| 141 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) of Hindware / CERA or its equivelent with100 mm sand cast Iron/PVC P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete, includingcutting and making good the walls and floors wherever required:(i) White Vitreous china Orissa Pan ( 580x440 mm) in white shade of No 20042 of Hindware or its equivelent with twin flushing cistern. |
| 142 | Providing and fixing Vetrious China Flat back wash basin 550x460 mm under counter in white shade of with pedestal of Hindware or Cera orits equivlant , C.I. brackets, , 32 mm C.P. brass waste of standard pattern, including painting of fitting sand brackets, cutting and making good the walls wherever require:(i) White Vitreous China Wash basin including carriage of materials within all leads and lift of No.10008 of Hindware Somany,Cera / or its equivlent as approved including carriage of materials within all leads and lift. |
| 143 | Providing and fixing white vitreous china squatting plate urinal pot with integral rim longitudinal flush pipe and cistern etc. complete in all respect including carriage of materials in all leads and lifts.. |
| 144 | Providing and fixing Vetrious China Flat back wash basin with half pedestal of Hindware or its equivlant , C.I. brackets, , 32 mm C.P. brass waste of standard pattern, including painting of fitting sand brackets, cutting and making good the walls wherever require:(i) White Vitreous China Wash basin ( Clair) of size 55x 40 cm with Pedestal of Cera or its equivlent including carriage of materials within all leads and lift of No.10008 of Hindware Somany,Cera / or its equivlent including carriage of materials within all leads and lift. |
| 145 | Providing and fixing Vetrious China Flat back wash basin 510x400 mm of white shade with pedestal of Hindware or Cera orits equivlant , C.I. brackets, , 32 mm C.P. brass waste of standard pattern, including painting of fitting sand brackets, cutting and making good the walls wherever require:(i) White Vitreous China Wash basin including carriage of materials within all leads and lift of No....... of Hindware Somany,Cera / or its equivlent as approved including carriage of materials within all leads and lift. |
| 146 | Providing and fixing white Stain less Steel sink as per approved sample with C.I. brackets, C.P. brass chain with rubber plug, 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required including carriage of materials within all leads and lift.(i) Kitchen sink with drain board 57x45x22 cm of Hindware/ CERA or its equivalent. |
| 147 | Providing and fixing white Stain less Steel sink double bowl as per approved sample with C.I. brackets, C.P. brass chain with rubber plug, 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, includingpainting of fittings and brackets, cutting and making good the wall wherever required including carriage of materials within all leads and lift.(i) Kitchen sink with drain board 100x51x20 cm of Hindware/ CERA or its equivalent. |
| 148 | Providing and fixing PVC Finolex type - B single equal branch plain including carriage of materials within all leads and lift: 150 mm dia. |
| 149 | (ii) 110 mm dia.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge |
| 150 | Providing and fixing PVC Finolex type - B single un-equal branch plain Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge.: 110 mmx75 mmm dia |
| 151 | Providing and fixing PVC ( Finolex ) Plain bend ISI marked including fixing with approved adhesive etc. Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge.:150 mm dia. |
| 152 | (ii) 110 mm dia.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 153 | (iii) 75 mm dia.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 154 | Providing and fixing PVC ( Finolex ) Plain door bend ISI marked including fixing with approved adhesive etc. complete including carriage of materials in all leads and lifts:110 mm dia. |
| 155 | (iii) 75 mm dia.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 156 | Providing and fixing PVC ( Finolex ) Coller ISI marked including fixing with approved adhesive etc. Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge.:150 mm dia. |
| 157 | (ii) 110 mm dia.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 158 | (iii) 75 mm dia.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 159 | Providing and fixing MS Flat 20x5 mm clamps of approved design of C.I or S.C.I or PVC pipes fixed with steel screws & rawl plugs and cost of . including carriage of materials within all leads and lifts: including carriage of materials within all leads and lifts:110 mm dia. |
| 160 | (ii) 75 mm dia.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 161 | Providing and fixing PVC Finolex Clamps ISI marked of pproved design with steel screws and rawl plugs etc. complete and cost of cutting holes etc. Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge.:110 mm dia |
| 162 | Providing and fixing PVC floor trap ISI marked of self cleaning design including fixing with approved adhesive, cost of cutting and making good the wall and floors etc. Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge.:-110 mm X 75 mm. |
| 163 | Providing and fixing PVC Cowl ISI marked of approved design . Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge.:110 mm dia. |
| 164 | Providing and fixing CP grating of Jal or ESS or approved quality Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge.:110 mm dia. |
| 165 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. (a) Semi Rigid 40mm dia |
| 166 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing including carriage of materials within all leads and lift. :(i) Rectangular shape 600x450 mm |
| 167 | Providing and fixing 600x120x5 mm Acrylic shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc.,complete including carriage of materials within all leads and lift.. |
| 168 | Providing and fixing C.P Toilet paper holder of Jal /ESS or superior quality including carriage of materials within all leads and lift. |
| 169 | Providing and fixing PVC Offset 45 degree including carriage of materials in all leads and lifts:110 mm dia metre |
| 170 | (ii) 75 mm dia metre. |
| 171 | Providing and fixing C.P. brass of Jal or ESS or its equivlent bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 172 | Providing and fixing C.P. brass (ISI marked of Jal or ESS or its equivlent Basin Mixer of approved quality conforming to IS standards and weighing not less than 810 gms.Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge. |
| 173 | Providing and fixing C.P. Brass extension nipple (size15mmx50mm) of approved make and quality as per direction of Engineer-in-charge including carriage of materials within all leads and lift.. |
| 174 | Providing and fixing C.P. brass (ISI marked of Jal or ESS or its equivlent angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Complete including carriage of material within all leads and lifts as per direction of Engineer-in-charge..(i) 15mm nominal bore |
| 175 | Poviding and fixing C.P towel rail of Jal/ESS or its equivlant make complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.(i) 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms including carriage of materials within all leads and lift. |
| 176 | Providing and fixing C.P brass towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, as approved by the Engineer. |
| 177 | Providing and fixing C.P Health Faucet of Jal/ESS or its equivlant complete of superior quality including carriage of materials within all leads and lift. |
| 178 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of Jal/ESS or other make as approved by Engineer - in - charge including carriage of materials within all leads and lift.. |
| 179 | Providing and fixing SST P Grab Bars of Jal/ESS /Hindware or any its equivlant approved make for handicapped persion including fixing complete including carriage of materials in all leads and lifts. |
| 180 | Providing and fixing Liquid soap container of Jal/ESS or its equivlant make or approved brand and manufacturer superior quality as per direction of Engineer-in- Charge including carriage of materials within all leads and lift. |
| 181 | Providing and fixing Stain less Steel Soap Dish of Jal/ESS or its equivlant make or approved superior quality with fitting arrangements, complete in all respect as per direction of Engineer-in- Charge including carriage of materials within all leads and lift. |
| 182 | Providing and fixing C.P brass long body bib tap of Jaquar or its equivlant make or approved superior quality with fitting arrangements, complete in all respect as per direction of Engineer-in- Charge including carriage of materials within all leads and lift. |
| 183 | Providing and fixing C.P. brass (ISI marked of Jal or ESS or its equivlent angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 including carriage of materials within all leads and lift.(i) 15mm nominal bore |
| 184 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :(i) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including carriage of materials within all leads and lift. |
| 185 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :(ii) Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 186 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design including carriage of materials within all leads and lift. :Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 187 | Cutting holes upto 30cmx30 cm in walls and making good the same including disposal of dismentalled materials in all leads at his own cost including carriage of materials within all leads and lift.. |
| 188 | Cutting holes upto 15 cmx15 cm in RCC floors for passing drain pipes including disposal of dismentalled materials in all leads at his own cost. |
| 189 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality(i) Rectangular shape 600x450 mm internal dimensions of NTC or equivelent including carriage of materials within all leads and lift. |
| 190 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design(i)100x100 mm size P type.(i) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including carriage of materials within all leads and lift. |
| 191 | Providing and fixing Water pump (2 H.P.) of Kirloskar make to Lift rain water including carriage of materials within all leads and lifts :- |
| 192 | Providing and fixing G.I. Union ( Unieq) in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) including carriage of materials within all leads and lift. 20 mm dia nominal bore: |
| 193 | (ii)15 mm dia nominal bore. |
| 194 | Providing and fixing PVC reducer including carriage of materials in all leads and lifts:ISI marked including fixing with approved adhesive etc. complete within all leads, lifts of materials and other incidentals. 150x110 mm (one hundred fifty by one hundered ten milimetre) nominal size. |
| 195 | (ii) 110x75 mm size |
| 196 | Providing and fixing PVC (finolex) Double equal branch with oval access door, ISI marked insertion rubber washer 3 mm thick bolts and nuts complete including fixing with approved adhesive etc. complete (i) 110mm (one hundred ten milimetre) nominal size including carriage of materials within all leads and lift. |
| 197 | (ii) 75 mm ( seventy five milimetre) nominal size. including carriage of materials within all leads and lift. |
| 198 | Providing and fixing PVC Connection pipe 45 cm in length. including carriage of materials within all leads and lift. |
| 199 | Providing and fixing G.I inlet connection for wash basin or sink complete with accesesories of Jaquar or its equivlant superior quality including carriage of materials within all leads and lift. |
| 200 | Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) :(i) 100 mm |
| 201 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B |
| 202 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. group b |
| 203 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. |
| 204 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.. |
| 205 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 206 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 amps modular socket outlets and 2 nos 5/6 amps modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 207 | Wattage of LED fittings - As per following parameter. |
| 208 | Total lumens of the fittings - as per wattage |
| 209 | Diffuser - Polycarbonate diffuser/PMMA |
| 210 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 211 | Input frequency - 50 Hz + 1 Hz |
| 212 | Power factor - Minimum 0.90 |
| 213 | Luminaire efficacy - ≥100 lm/w |
| 214 | Color rendering index - CRI shall be greater than 80 |
| 215 | Working/ operating temperature - 00 to + 450c or better |
| 216 | Color temperature - 60000K + 10% |
| 217 | Electronic Driver |
| 218 | Drive current (LED) - As per OEM. |
| 219 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 220 | Type of driver - Constant current output driver |
| 221 | THD - Less than 10% |
| 222 | Surge Protection - 2.5 KV minimum |
| 223 | Efficiency Driver - ≥85% |
| 224 | Protection - Shall have under voltage and over voltage protection. |
| 225 | Guarantee of LED fittings including LED driver - 5 years against manufacturing defect. |
| 226 | Fixture - Should comply with LM 79 test from UL/NABL lab. |
| 227 | LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. |
| 228 | Life of LED - 50000 burning hours at 70% lumen maintenance 5 years warranty |
| 229 | Lumen output of the fitting |
| 230 | Lumen output of the fitting |
| 231 | LED Down Light ≥2400Lumens. |
| 232 | LED Down Light ≥1500Lumens. |
| 233 | LED Down Light ≥1000Lumens. |
| 234 | S/E of LED bulk head IP 66 rated with aluminium body/PDC housing The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings. |
| 235 | Specification of LED fittings: |
| 236 | Wattage of LED fittings - As per following parameter. |
| 237 | Total lumens of the fittings - as per wattage |
| 238 | Diffuser - Polycarbonate diffuser/PMMA |
| 239 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 240 | Input frequency - 50 Hz + 1 Hz |
| 241 | Power factor - Minimum 0.90 |
| 242 | Luminaire efficacy - ≥80 lm/w |
| 243 | Color rendering index - CRI shall be greater than 80 |
| 244 | Working/ operating temperature - 00 to + 450c or better |
| 245 | Color temperature - 60000K + 10% |
| 246 | Electronic Driver |
| 247 | Drive current (LED) - As per OEM. |
| 248 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 249 | Type of driver - Constant current output driver |
| 250 | THD - Less than 10% |
| 251 | Surge Protection - 2 KV minimum |
| 252 | Efficiency Driver - ≥85% |
| 253 | Protection - Shall have under voltage and over voltage protection. |
| 254 | Guarantee of LED fittings including LED driver - 5 years against manufacturing defect. |
| 255 | Fixture - Should comply with LM 79 test from UL/NABL lab. |
| 256 | LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. |
| 257 | Life of LED - 50000 burning hours at 70% lumen maintenance 5 years warranty |
| 258 | Lumen output of the fitting |
| 259 | LED Bulk Head ≥800Lumens. |
| 260 | Providing and installation of following type of surface mounting 1 feet by 4 feet type LED Panel with PDC/CRCA housing ,anti glare multilayer diffuser,surge protection 2.5 KV luminaire efficacy > 110 lm/Watt with UGR<30 minimum 50000 burning hours,THD<10% in white finish and seprated energy efficient constant current, non-integral, electronic driver;relevent LM 79/80 complaince from UN/NABL Lab suitable for input voltage: AC 140-270 V, 50/60Hz, complete with all accessories, connections, testing etc. as required: of Approved Make |
| 261 | Specification of LED fittings: |
| 262 | Wattage of LED fittings - As per following parameter. |
| 263 | Total lumens of the fittings - as per wattage |
| 264 | Diffuser - polycarbonate/acyrlic diffuser UGR <30 |
| 265 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 266 | Input frequency - 50 Hz + 1 Hz |
| 267 | Power factor - Minimum 0.90 |
| 268 | Luminaire efficacy - ≥120 lm/w |
| 269 | Color rendering index - CRI shall be greater than 80 |
| 270 | Working/ operating temperature - 00 to + 450c or better |
| 271 | Color temperature - 60000K + 10% |
| 272 | Electronic Driver |
| 273 | Drive current (LED) - As per OEM. |
| 274 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 275 | Type of driver - Constant current output driver |
| 276 | THD - Less than 10% |
| 277 | Surge Protection - 2.5 KV minimum |
| 278 | Efficiency Driver - ≥85% |
| 279 | Protection - Shall have under voltage and over voltage protection. |
| 280 | Guarantee of LED fittings including LED driver - 5 years against manufacturing defect. |
| 281 | Fixture - Should comply with LM 79 test from UL/NABL lab. |
| 282 | LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. |
| 283 | Life of LED - 50000 burning hours at 70% lumen maintenance 5 years warranty |
| 284 | Lumen output of the fitting |
| 285 | LED Panel Light 1x4' ≥4320 Lumens. |
| 286 | S/E of LED Panel with PDC body and prismatic diffuser to be mounted in recess The job includes carriage, erection, making connections testing and commissioning of the fittings.1 * 4 feet |
| 287 | Specification of LED fittings: |
| 288 | Wattage of LED fittings - As per following parameter. |
| 289 | Total lumens of the fittings - as per wattage |
| 290 | Diffuser - Prismatic multilayer diffuser UGR <19 |
| 291 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 292 | Input frequency - 50 Hz + 1 Hz |
| 293 | Power factor - Minimum 0.90 |
| 294 | Luminaire efficacy - ≥120 lm/w |
| 295 | Color rendering index - CRI shall be greater than 80 |
| 296 | Working/ operating temperature - 00 to + 450c or better |
| 297 | Color temperature - 60000K + 10% |
| 298 | Electronic Driver |
| 299 | Drive current (LED) - As per OEM. |
| 300 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 301 | Type of driver - Constant current output driver |
| 302 | THD - Less than 10% |
| 303 | Surge Protection - 2.5 KV minimum |
| 304 | Efficiency Driver - ≥85% |
| 305 | Protection - Shall have under voltage and over voltage protection. |
| 306 | Guarantee of LED fittings including LED driver - 5 years against manufacturing defect. |
| 307 | Fixture - Should comply with LM 79 test from UL/NABL lab. |
| 308 | LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. |
| 309 | Life of LED - 50000 burning hours at 70% lumen maintenance 5 years warranty |
| 310 | Lumen output of the fitting |
| 311 | LED Panel Light 1'x4' ≥4320Lumens. |
| 312 | supply installation testing and commissioning of LED linear picture light engineered for surface wall-mounted installations, featuring an adjustable head to ensure precise directional lighting . Constructed from durable extruded aluminium and metal with a premium brushed bronze finish, (500*80*95), backed by an IP20 ingress protection rating for safe indoor use. 12-Watt luminaire operates efficiently on a standard 220–240V AC supply at 50/60 Hz with a power factor of 0.9, luminous flux of 420 lumens. Color Temperature (CCT) of 3000-6500K ,CRI>80 approved make philips muzirius ,wipro garnet ,jaguar linae,havells adonia or any other make approved by engineer in charge |
| 313 | S/E of LED Batten with aluminium extrusion housing The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings. |
| 314 | Specification of LED fittings: |
| 315 | Wattage of LED fittings - As per following parameter. |
| 316 | Total lumens of the fittings - as per wattage |
| 317 | Diffuser - Polycarbonate diffuser/PMMA |
| 318 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 319 | Input frequency - 50 Hz + 1 Hz |
| 320 | Power factor - Minimum 0.90 |
| 321 | Luminaire efficacy - ≥110 lm/w |
| 322 | Color rendering index - CRI shall be greater than 80 |
| 323 | Working/ operating temperature - 00 to + 450c or better |
| 324 | Color temperature - 60000K + 10% |
| 325 | Electronic Driver |
| 326 | Drive current (LED) - As per OEM. |
| 327 | Operating voltage - 140 V to 270 V, AC supply or better. |
| 328 | Type of driver - Constant current output driver |
| 329 | THD - Less than 10% |
| 330 | Surge Protection - 2.5 KV minimum |
| 331 | Efficiency Driver - ≥85% |
| 332 | Protection - Shall have under voltage and over voltage protection. |
| 333 | Guarantee of LED fittings including LED driver - 5 years against manufacturing defect. |
| 334 | Fixture - Should comply with LM 79 test from UL/NABL lab. |
| 335 | LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. 5 years warranty |
| 336 | Life of LED - 50000 burning hours at 70% lumen maintenance 5 years warranty |
| 337 | Lumen output of the fitting |
| 338 | LED Batten Light ≥2200Lumens. |
| 339 | LED Batten Light ≥1000Lumens. |
| 340 | LED Batten Light ≥2200Lumens. |
| 341 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 342 | Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height 3 meters impact resistant rating IK04 with diiferent time delay settings and for 5-10 meter diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. make Panasonic, wipro,legrand schneider,ABB or any other make approved by engineer in charge |
| 343 | Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, , suitable for connected load upto 5-10Amp ,2 module wall mounted fixing arrangements i/c programming at site etc. complete as required. make legrand, schneider ,ABB,Panasonic or any other approved by engineer in charge |
| 344 | Supplying and fixing call bell/ buzzer suitable for 230 v 50 hz complete as required |
| 345 | Installation of ventilatinmg /exhaust fan in the existing opening, including making good BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor the damage, connection, testing, commissioning etc. as required.Supply & Erection of Ventilating Fan ) following size complete with motor,, with minimum power consumption, rigid frame with rubber mounting for silent operation, in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC.200 mm sweep |
| 346 | Providing and installation exhaust fan of following sizes in the existing opening, Double ball bearing type metal frame including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: of Approved Make Domestic type. |
| 347 | Exhaust Fan, heavy duty, 300 mm sweep |
| 348 | Providing and installation of instant Electric water heater (Geyser) of various sizes with 8 bar pressure rating 3kw element and safety valve installation by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. complete as required:- 3 litres capacity |
| 349 | Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. complete as required:- 25 Liter capacity water heater (Cat-A) |
| 350 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 351 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 352 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 353 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 354 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 355 | 4 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 356 | 4 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 357 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 358 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 359 | 3 x 1.5 sq. Mm |
| 360 | 3 x 4 sq. Mm |
| 361 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed power cable, 1.1 KV grade of following sizes on wall surface as required 1100 V |
| 362 | Armoured cable 6 sq. mm (3.5 core) |
| 363 | Armoured cable 35 sq. mm (3.5 core) |
| 364 | Armoured cable 300 sq. mm (3.5 core) |
| 365 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Armoured cable 300 sq. mm (3.5 core) |
| 366 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 367 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 368 | Providing and installation of following type of LED retrofit lamp B-22/E14/E27 holder base with polycarbonate body and aluminium heat sink; suitable for input voltage: AC 220-240 V, 50/60Hz, including mounting in existing fixture, testing etc. as required complete in all respects. Make: Philips, Syska, GE, Bajaj, C&S, Panasonic or any other approved by Engineer-in-Charge.LED 9 watt |
| 369 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 370 | Single pole |
| 371 | Supplying and fixing following rating, followings poles 10ka 240/415v 'C' curves miniature circuit braker suitable for inductive load of following poles in the exsisting MCB DB complete with connections, testing and commissioning etc. as required.63 amp |
| 372 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. RCCB 63 Amp 10 KA breaking capacity |
| 373 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 374 | 8 way , Double door |
| 375 | 12 way , Double door |
| 376 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 377 | 63 mm dia |
| 378 | 110 mm dia |
| 379 | Supplying and installation of following size of perforated painted with powder coating M.S cable tray with perforation not more than 17.5 % in convenient section, joined with connectors,suspended from the ceiling(if required) with MS Suspenders,including bolts & nuts painting suspenders etc as required MS Cable tray 250 X 50mm |
| 380 | Supplying and laying of UPVC pipes having dimensions 100*50mm having standard length 2 meters required complete in all respect in at site Make : AKG,honeywell,Precision pipes or any other approved by engineer in charge |
| 381 | S/E of MCCB 4 Pole 415 Volt. with fixed thermal and fixed magnetic for overload and short circuit protection breaking Capacity (Ics=100% Icu with positive isolation) with/ without Spreader/ Rotary Handle. |
| 382 | MCCB 40- 100 Amp. 36 ka 4 Pole Release without rotary handle |
| 383 | Supplying and fixing TP&N copper bus-bar chamber suitable for 415 volts capacity with 4 No. copper strip bus-bars each of length and x-section suitable for following current carrying capacities, enclosure made of sheet steel, dust protected, duly powder painted with detachable gland plate and other accessories including drilling holes on the board, making connections, earthing etc. asrequired. 100 A Copper Busbar Chambers 15\\" (SS Enclosure) |
| 384 | Supply, Installation,testing and commissioning of Floor mounted powder coated siemens grey RAL 7035 shade MS enclosure made of CRCA sheet of 2 mm thickness with gaskets,lifting hooks& Hinged door ,cable entry (top/bottom) Sub Main Distribution Board (SMDB) panel (MAIN) with following description and specifications: |
| 385 | MAIN PANEL (TTA DESIGN)IS 61439 compliant |
| 386 | INCOMER : |
| 387 | ACB 800A, FRAME-I FP, MDO, 80KA FOR 1SEC. M.P. BASED REL. WITH O/L, S/C & E/F PROT. ACB WITH UW-MTX1.5G (LSING + DISPLAY) |
| 388 | MFM 4410 LED METER CL 1.0 WITH RS485, PARAMETERS: V, A, F, PF, KW, KVA, KVAR, KWH, KVAH, KVARH, RUNHOURS, ON HOURS, PHASE ANGLE, INTERRUPTS, THD, EVENTS (HIGH-LOW), NEUTRAL CURRENT , K FACTOR |
| 389 | CT 800/5A CL-1.0, 10VA RESIN CAST/NYLON CAST |
| 390 | CT SHORTING LINKS |
| 391 | ACB ON - INDICATION LAMP LED TYPE RED - 230V AC |
| 392 | PHASE INDICATION LAMP RED LED 230V AC |
| 393 | PHASE INDICATION LAMP YELLOW LED 230V AC |
| 394 | PHASE INDICATION LAMP BLUE LED 230V AC |
| 395 | MCB 6A SP 10KA, C-CURVE |
| 396 | NEUTRAL LINK |
| 397 | NOTE: 80KA MDO ACB OFFERED IN PLACE OF 75KA. |
| 398 | OUTGOINGS |
| 399 | O/G - 400A MCCB - 02NOS. |
| 400 | 400A FP 50KA MCCB, Ics=100% Icu WITH THERMAL MAGNETIC RELEASEI.E. O/L & S/C PROTECTION |
| 401 | EXTENDED ROTARY HANDLE FOR MCCB - 400A |
| 402 | SPREADER SET FOR FP (SET OF 8) MCCB - 400A |
| 403 | MCCB ON - INDICATION LAMP LED TYPE RED - 230V AC |
| 404 | MCB 6A SP 10KA, C-CURVE |
| 405 | NEUTRAL LINK |
| 406 | ACCESSORIES |
| 407 | 7W LED BULB 230V AC WITH HOLDER |
| 408 | SPACE HEATER WITH THERMOSTAT CONTROL |
| 409 | DOOR LIMIT SWITCH 6A, 1C/O |
| 410 | MCB 6A SP 10KA, C-CURVE |
| 411 | MCB 6A DP 10KA, C-CURVE |
| 412 | NEUTRAL LINK |
| 413 | 6A, 240V 3PIN POWER SOCKET & SWITCH |
| 414 | TOGGLE SWITCH - ON/OFF - 6A |
| 415 | MAIN AL. BUS BAR (NEUTRAL 50%) |
| 416 | 800A TPN (50% NEUTRAL) ALUMINIUM BUS BAR DULY INSULATED WITH COLOR CODED LIQUID PAINT / PHASES MARKED IN COLURED PVC TAPES AND SUPPORTED WITH BUS BAR SUPPORTS AND INSULATORS - DMC/SMC. |
| 417 | CROSS-SECTION AREA CONSIDERED AS PER TTA |
| 418 | 2R X 50 X 10 FOR PHASES |
| 419 | 1R X 50 X 10 FOR NEUTRAL |
| 420 | 1R X 50 X 06 FOR EARTHING - AL. STRIP |
| 421 | ENCLOSURE : L=1950MM X H=2075MM X D=800MM (APPROX.) |
| 422 | MS CRCA SHEET 2.0/1.6MM (LOAD BEARING - 2MM, NON-LOAD BEARING, DOORS, COVERS, INTERNAL PARTITIONS - 1.6MM) WITH 3MM GLAND PLATE DULY POWDER COATED IN SIEMENS GRAY SHADE (RAL-7035) AS PER IS:5, PANEL LOCKS, PU GASKETS IN DOORS, TYPE FLOOR MOUNTED, INDOOR TYPE, DUST AND VERMIN PROOF WITH REINFORCEMENT.BASE FRAME - 3MM HRCA |
| 423 | PANEL ACCESSORIES - DOOR HINGES, PROTECTION COVERS, PANEL NAME PLATE, FEEDER NAME PLATES AND HARDWARES - NUTS, BOLTS, WASHERS - PLAIN AND SPRING FOR BUS BAR AND PANEL CONSTRUCTION ALONG WITHbPANEL SHROUDING ACCESS. |
| 424 | Supply, Installation,testing and commissioning of Floor mounted powder coated siemens grey RAL 7035 shade MS enclosure made of CRCA sheet of 2 mm thickness with gaskets,lifting hooks& Hinged door ,cable entry (top/bottom) Sub Main Distribution Board (SMDB) panel (HEATING) with following description and specifications: |
| 425 | distribution panel PANEL (TTA DESIGN) IS 61439 compliant |
| 426 | INCOMER |
| 427 | 400A FP 50KA MCCB, Ics=100% Icu WITH THERMAL MAGNETIC RELEASEI.E. O/L & S/C PROTECTION |
| 428 | EXTENDED ROTARY HANDLE FOR MCCB - 400A |
| 429 | SPREADER SET FOR FP (SET OF 8) MCCB - 400A |
| 430 | MFM 4410 LED METER CL 1.0 WITH RS485, PARAMETERS: V, A, F, PF, KW, KVA, KVAR, KWH, KVAH, KVARH, RUNHOURS, ON HOURS, PHASE ANGLE, INTERRUPTS, THD, EVENTS (HIGH-LOW), NEUTRAL CURRENT , K FACTOR |
| 431 | CT 400/5A CL-1.0, 10VA RESIN CAST/NYLON CAST |
| 432 | CT SHORTING LINKS |
| 433 | MCCB ON - INDICATION LAMP LED TYPE RED - 230V AC |
| 434 | PHASE INDICATION LAMP RED LED 230V AC |
| 435 | PHASE INDICATION LAMP YELLOW LED 230V AC |
| 436 | PHASE INDICATION LAMP BLUE LED 230V AC |
| 437 | MCB 6A SP 10KA, C-CURVE |
| 438 | NEUTRAL LINK |
| 439 | OUTGOINGS |
| 440 | O/G - 63A MCCB - 07NOS. |
| 441 | 63A FP 25KA MCCB, Ics=100% Icu WITH THERMAL MAGNETIC REL. I.E.WITH O/L & S/C PROT. |
| 442 | EXTENDED ROTARY HANDLE FOR MCCB - 63A |
| 443 | ACCESSORIES |
| 444 | 7W LED BULB 230V AC WITH HOLDER |
| 445 | SPACE HEATER WITH THERMOSTAT CONTROL |
| 446 | DOOR LIMIT SWITCH 6A, 1C/O |
| 447 | MCB 6A SP 10KA, C-CURVE |
| 448 | MCB 6A DP 10KA, C-CURVE |
| 449 | NEUTRAL LINK |
| 450 | 6A, 240V 3PIN POWER SOCKET & SWITCH |
| 451 | TOGGLE SWITCH - ON/OFF - 6A |
| 452 | MAIN AL. BUS BAR (NEUTRAL 50%) |
| 453 | 400A TPN (50% NEUTRAL) ALUMINIUM BUS BAR DULY INSULATED WITH COLOR CODED LIQUID PAINT / PHASES MARKED IN COLURED PVC TAPES AND SUPPORTED WITH BUS BAR SUPPORTS AND INSULATORS - DMC/SMC. |
| 454 | CROSS-SECTION AREA CONSIDERED AS PER TTA |
| 455 | 1R X 50 X 10 FOR PHASES |
| 456 | 1R X 50 X 06 FOR NEUTRAL |
| 457 | 1R X 25 X 06 FOR EARTHING - AL. STRIP |
| 458 | ENCLOSURE : L=1700MM X H=2075MM X D=450MM (APPROX.) |
| 459 | MS CRCA SHEET 2.0/1.6MM (LOAD BEARING - 2MM, NON-LOAD BEARING, DOORS, COVERS, INTERNAL PARTITIONS - 1.6MM) WITH 3MM GLAND PLATE DULY POWDER COATED IN SIEMENS GRAY SHADE (RAL-7035) AS PER IS:5, PANEL LOCKS, PU GASKETS IN DOORS, TYPE FLOOR MOUNTED, INDOOR TYPE, DUST AND VERMIN PROOF WITH REINFORCEMENT.BASE FRAME - 3MM HRCA |
| 460 | PANEL ACCESSORIES - DOOR HINGES, PROTECTION COVERS, PANEL NAME PLATE, FEEDER NAME PLATES AND HARDWARES - NUTS, BOLTS, WASHERS - PLAIN AND SPRING FOR BUS BAR AND PANEL CONSTRUCTION ALONG WITHPANEL SHROUDING ACCESS. |
| 461 | ENCLOSURE : L=1700MM X H=2075MM X D=450MM (APPROX.) |
| 462 | MS CRCA SHEET 2.0/1.6MM (LOAD BEARING - 2MM, NON-LOAD BEARING, DOORS, COVERS, INTERNAL PARTITIONS - 1.6MM) WITH 3MM GLAND PLATE DULY POWDER COATED IN SIEMENS GRAY SHADE (RAL-7035) AS PER IS:5, PANEL LOCKS, PU GASKETS IN DOORS, TYPE FLOOR MOUNTED, INDOOR TYPE, DUST AND VERMIN PROOF WITH REINFORCEMENT.BASE FRAME - 3MM HRCA |
| 463 | PANEL ACCESSORIES - DOOR HINGES, PROTECTION COVERS, PANEL NAME PLATE, FEEDER NAME PLATES AND HARDWARES - NUTS, BOLTS, WASHERS - PLAIN AND SPRING FOR BUS BAR AND PANEL CONSTRUCTION ALONG WITHPANEL SHROUDING ACCESS. |
| 464 | Supply and installation of Hot dip octagonal galavanised iron pole 5 meters having wall thickness 3 mm. C/s A/F - top = 70mm, bottom =135 mm, base plate 220x220x12 mm, 500 mm long weatherproof reinforced door opening with junction box mounting arrangement inclusive of Sleek junction box with one 6A SP MCB and 16Sqmm stud type connector, suitable Single arm bracket 1 m,20mm dia. threaded made to J shape and having 450 mm total length steel grade EN8 foundation bolts - 4 x16 mm dia. with nuts, templates and all complete as per approved drawing.Foundation RCC 1:2:4 shall be of size 550x550mm and depth 1200 mm c/c as per approved drawing.The foundation shall extend above sorrounding ground/driveway level for 200 mm and have slant 63mm dia. PVC sleeve cast insitu foundation for cable entry as per the drawing, complete in all respects as required:-Make: Wipro, Bajaj / G.E. power, Crompton Greaves / Philips / Transrail Lighting |
| 465 | Supply and installation of Hot dip octagonal galavanised iron pole 5 meters having wall thickness 3 mm. C/s A/F - top = 70mm, bottom =135 mm, base plate 220x220x12 mm, 500 mm long weatherproof reinforced door opening with junction box mounting arrangement inclusive of Sleek junction box with one 6A SP MCB and 16Sqmm stud type connector, suitable double arm bracket 1 m,20mm dia. threaded made to J shape and having 450 mm total length steel grade EN8 foundation bolts - 4 x16 mm dia. with nuts, templates and all complete as per approved drawing.Foundation RCC 1:2:4 shall be of size 550x550mm and depth 1200 mm c/c as per approved drawing.The foundation shall extend above sorrounding ground/driveway level for 200 mm and have slant 63mm dia. PVC sleeve cast insitu foundation for cable entry as per the drawing, complete in all respects as required:-Make: Wipro, Bajaj / G.E. power, Crompton Greaves / Philips / Transrail Lighting |
| 466 | Providing and installation of following type of LED Street light 120 Watt with pressure die cast housing along with prismatic polycarbonate modular secondary lens optics for city road application with IP66 ingress protection and impact resistance of IK08, 4KV inbuilt and 10kv external surge protection with top opening driver cover for easy maintenance suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing and commissioning etc. as required. Make: Havells,Philips, Syska, Bajaj, C&S, Panasonic or any other approved by Engineer-in-Charge. |
| 467 | Supplying and fixing following way, Verticle type three pole and neutral,three Phase Segregated DB, sheet steel, MCB distribution board,MCCB Incomer - ,IK 09,CB* as incomer,DP MCB/RCBO as sub-incomer and SP MCBs as outgoings 415 volts,Ready to use DBs - Provided with 100A insulated phase bus-bars | neutral bar/s with shroud/s | earth bar/s | sticking saddles | cement spill protector | color-coded interconnecting wire set | cable ties | blanking plates and circuit identification label s on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 468 | (4+36) 12 way, Double door |
| 469 | (4+24) 8 way, Double door |
| 470 | LAN ,CCTV,Fire Alarm |
| 471 | Supplying and fixing of 25mm PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-Make: Diplast/ AKG/BEC |
| 472 | Supplying and fixing of metal modular box of 2 module along with the required Face Plate (Single/Dual) recessed or on surface or as required to have complete solution in all respects and to best staisfaction of engineer in charge. |
| 473 | Supply Installation, Testing and Comissioning of Unshielded Twisted Pair, Category 6, 23 AWG solid bare copper, Insulation: High Density Polyethylene, Jacket: FRPVC, Frequency: Tested up to Minimum 250 MHz, Fire Rating: IEC 60332-1, IEC 60754, IEC 61034, Standard Compliance: ANSI/TIA-568 C.2 category 6, ISO/IEC-11801, Class E/ IEC 61156-5: category 6, Certification: UL, CE, ETL Verified in the existing surface/ recessed Steel/PVC conduit/ raceway as required. Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 474 | 1 run of cable |
| 475 | 2 run of cable |
| 476 | 3 run of cable |
| 477 | Supply Installation, Testing and Comissioning of Category 6 UTP Patch Panel Punch Down 24 Port,Wiring Standards EIA/TIA 568 A/B, Flammability rating UL 94V-0, Safety Rating UL1863 , Transmission ISO/IEC 11801:2002 ANSI /TIA/EIA-568.B.2-10, Category 6 UTP Keystone Jack Un Shuttered Punch Down 180Deg Blue manufactured with an integral cable strain relief,IEEE 802.af, IEEE 802.3at for PoE applications, I/Os Individually replaceable, Rear Cable Manager, Rack Mountable, ISO/IEC 11281, IEC 60603-7, TIA-968-A, Certification: UL, CE. Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 478 | Supply Installation, Testing and Comissioning of SFP Module. Make Cisco/Alcatel/Zyxel/Arista/Extreme |
| 479 | Supply Installation, Testing and Comissioning of 06 Core Singlemode OS2 Central Loose Tube Armoured External Cable,6 Core Singlemode OS2 Central Loose Tube Armoured External Cable. All OFC and its Components shall be UL/EN/IEC 60950 compliant and any relevant National/International certification like BIS/NABL or Equivalent shall be submitted for the same. OEM should be present and directly Registered in India from last 5 Years. Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 480 | Supply Installation, Testing and Comissioning of LC/PC Singlemode OS2 1.5m LSZH Pigtail Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 481 | Supply Installation, Testing and Comissioning of LC/PC-LC/PC Singlemode OS2 3m Duplex LSZH Patch Cord.All OFC and its Components shall be UL/EN/IEC 60950 compliant and any relevant National/International certification like BIS/NABL or Equivalent shall be submitted for the same\\" Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 482 | Supplying, Installation and fixing of CAT6 information outlet(I/O) meeting or exceeding the channel specifications of Amendment 1 to ISO/IEC 11801:2002 Class EA and ANSI/TIA-568-C.2 Catergory 6; RJ-45 jack should be supplied with shutter to avoid dust; Thermoplastic UL94V-0 rated or equivalent; minimum 750 insertion cycles; contact plating of 50μ” Gold/100μ” Nickel with minimum contact force of 100gms; IDC connector with minimum 200 re-terminations; copper alloy contact material; accommodat wire 22-24 AWG solid; should be covered by UL/ETL certification program; of following colours conforming to Cat 6 Standards, as required to have complete solution in all respects and to best staisfaction of engineer in charge.Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 483 | White |
| 484 | Supply Installation, Testing and Comissioning of Category 6 1 mtr. Patchcord, 24 AWG Stranded, Unshielded Polycarbonate plug, Gold over Nickel Contacts, LSZH Jacket, 1000 Mating Cycles, Fire rating: IEC 60332-1, Standard Compliance: ANSI/TIA-568-C.2 and ISO/IEC-11801, IEC 61156-2, EN 50173; EN 50288-6-2, Certification: UL, CE, ETL Channel tested for cameras at both ends, switches and servers in control room, complete as required. Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 485 | Grey/ White |
| 486 | Providing and patching CAT6 patch cord UTP LSZH 2.0 meter with transparent plug with anit-snag slip on boots; RJ-45 plug standard compliant to ISO/IEC 6066-7-4 and FCC 47 Part 68; Fire propagation compliant with CSA FTI, IEC 60332-1, IEC 61034; Minimum 750 insertion cycles; UL/ETL verified; and of following colours as required to have complete solution in all respects and to best staisfaction of engineer in charge.Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 487 | Grey/ White |
| 488 | Supplying, Installation Testing and commissioning of Rj-45 jack conforming to Cat6 standards; as required to have complete solution in all respects and to best statisfaction of engineer in charge. Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 489 | Supply Installation, Testing and Comissioning of 24P Managed Ethernet Switch should have total 28 Nos, Gigabit port including 24 Nos. of 10/100/1000 Mbps Ethernet Poe ports and 4 Nos of 10G SFP+, The switch should be flexible enough to be managed through cloud and standalone mode. The cloud managaemnet should be available from Day 1. The Switch should have Non blocking wire speed switch fabric should have min 128 Gbps back plan or more and should have min 95.2 mpps or more, the switch should support min 16 mac addresss or more, the switch should have po power budget of at list 375 w or more. should support EEE i EEE802. 3AZ stand for minimise the power consumpttion on per port basic wire supplying power on the basis of cable lenth and active ports only should support dual softaware(firmware) image, iEEE802, 3 10 based ethernet, 1EEE 802. ab 1000 base t ethernet, 1EEE 802 .3X flow control, IEEE 802.3 10 BASE-T ethernet , i EEE 802.1 P class of service, priority protocols, IEEE 802. 1X Port authentication , IEEE 802.3 AD LACP aggregation, rate limiting : rule based / port based bendwidtch control, 64 KBPS granularity, switch should support jambo farmes of 9KB , switch should support jumbo frames of kb, support IGMP/IGMP snooping V1, V2, V3, IEEE 802.3 AD LACP link aggrejation complete, up to at aggrejetion groups, should support IEEE 802.,1W rapid spanning tree protocol, switch should port protocol based spanning tree protocol (MSTP), should support multiple rapid spanning switch VLAN, ip subnet based, guest VLAN and MVR should support loop guard to avoid loops in network generated on unmanagaed switched, should support AAA thought radius and tacacs + servers, iV6 over ethernet, IPV6 address ICMPV6, dusting, neighbor discovery, Web-based management , SNMP v1, v2c, v3, should have cluster Stacking to manage up to 24 switches by single IP addressm, based on MAC address, VLAN, IP address , protocol TCP/UDP type and DSCP, The OEM Brand should be having valid ISO 9001, ISO 14001, ISO 45001:2018 all these certificates must be submeitted in technical bid. Operating temperature 0 Deg C to 50 deg C. Make Cisco/Juniper/Extreme/HPE |
| 490 | Supply and installation of Supply and installation of 802.11be (WiFi 7) wireless access point with 4x4 MIMO over 5/6Ghz radio.Should work on 2.4 Ghz, 5 GHz and 6Ghz wireless frequency simultaniously, WiFi 7 speeds up to 12.3Gbps or better.Should support maximal ratio Combining Should be operable at 20Mhz, 40Mhz, 80Mhz, 160MHz and 320Mhz channels, Should support data rates up to 688 mbps over 802. 11n and 8646 Mbps over 5Ghz and 11530 Mbps over 6Ghz Radio WiFi7, Should support A-MPDU (Tx/Rx), A-MSDU (Tx/Rx) packet aggregation. Should have cyclic delay diversity support, Should have maximum likehood demodulation support, Should have low density parity check support RF Specifications\\"Should be operable on the following frequency bands :5 GHz (IEEE 802.11 a/n/ac/ax/be) (FCC): 5.15 to 5.25 GHz; 5.470 to 5.850 GHz., 6 GHz (IEEE 802.11 ax) (FCC): 5.925 to 6.425 GHz; 6.425 to 6.525 GHz; 6.525 to 6.875 GHz; 6.875 to 7.125 GHz.AP should have the transmition power of 26 dBm or better. Should have antenna gain of atleast 1.4dBi on 2.4Ghz and 2.7dBi on 5Ghz and 3.17dBi on 6Ghz.Should support of connectivity for 256 devices per AP (128 device per Radio) maximum association Should have Min. Rx sensitivity up to -99 dBm.LAN 2x Ethernet port support multiGiga 2.5Gbps or better.Should support PoE power consumtion less than 22Watt.Should support the following standards - IEEE 802.3,IEEE 802.3u,IEEE 802.11ab, IEEE 802.3au, IEEE 802.3az,IEEE 802.3at WLAN Features Should support Mesh connectivity and when required with Cloud controller.Should support fast roaming Should support Mesh AP for multiple SSID and VLAN Wireless Security .Should support WEP , WPA/WPA2-PSK WPA/WPA2-Enterprise ,WMM (Wi-Fi Certified) ,WLAN Access control list, also support WPA3 Should support EAP-TLS, EAP-TTLS, EAP-PEAP, EAP-FAST, EAP-AKA and EAP-SIMShould support IEEE 802.1X ,RADIUS Authentication ,Microsoft AD Authentication , Web Authentication ,LDAP Authentication , MAC Filtering , Layer-2 Isolation , MAC Authentication.Should support atleast 16 of SSID Should authenticate to embedded RADIUS Server of controller with multiple profileShould have WLAN access control list feature/BSSS MAC filtering Network Should have IPv6 support from day-1 Should support VLAN and DHCP client QoS(PG) Should support WMM and WMM Power save features Should support Diffserv Marking Management Should be supplied with same make softwares which can detect all Aps in the network and managed from single console in standalone mode The software supplied with AP should be able to perform the following tasks - IP configuration/renew , Device Location, password configuration, device reboot, firmware upgrade, Batch AP configuration and firmware upgrade, Batch profile backup, Wi-Fi AP Planning, wireless healthe management and coverage detection AP should support Managed and standalone modes Should also be manageble through CLI, WEB console and SNMP Should have multiple level for management admin Access Point should support Standalone and Cloud Controller mode for single central worldwide management from the any corner of the world over the Internet conenction. For the local managemnet should support vendor specific utilities for local management. Access Point should support application secuity and Content security with Cloud based management Access Point should support NAT feature on cloud mode to provide the IP address to the connecetd clients. Access Point should be equipped with Basic free pack of cloud management from day one without addidtional license, for additional cloud feature OEM should provide advanced pack of licenses. Access Point should support application secuity and Content security, App Visibility with Bandwidth Throttlewith Cloud based management Access Point should support NAT mode over Cloud, which is used to have the AP create a DHCP server/subnet with its own NAT for the SSID. This provides minimum hardware requirement for Wi-Fi.Cloud management for AP should have mobile application App Store/Google Play) also to manage from anywhere.Cloud portal for access point also support Captive portal to provide internet access by using specific user name and password.Others MTBF value should be atleast 690,000 hrs or better Access Point should have PoE support , also should have option to power up with USB Type-C Port for power redundancy.Mount plate and mounting screws should be included.Certifications FCC Part 15C, FCC Part 15E, ETSI EN 300 328, EN 301 893, LP0002. FCC Part 15B, EN 301 489-1, EN 301 489-17, EN55022, EN55024, EN61000-3-2/-3, BSMI CNS13438 EN 60950-1, IEC 60950-1, BSMI CNS14336-1 Environmental SpecificationsShould support operating termperature upto 50°C Should be operable under humidity of 10% to 90% . Make:- Cisco/Alcatel//Extreme/HPE |
| 491 | Supply Installation, Testing and Comissioning of \\"Supply of 1U 19’” Easy Front Access (EFA) 12 Port Sliding Rack Mount SC duplex type loaded with Single Mode Coupler/Adaptor & Pigtails, Standard Compliance: TSE: EN 61587-1, Equipment - Tests for IEC 60917 and IEC 60297, Climatic and Environment: EN 61587-1/4.2, IEC60068-2-1, IEC60068-2-2, IEC60068-2-30, Earth Bond: EN61587-1/6.2, Flammability: EN61587-1/6.3, RoHS Fiber Coupler/Adaptor: SC Single Mode OS2 Duplex, Phosphor Bronze sleevs, Min 500 Mating Cycles, Standard Compliance: IEC 61300-2-18, IEC 61300-2-19, IEC 61300-2-1, IEC 61300-2-2 Fiber Pigtail: SC Single mode OS2 Simplex, 1.5 meter, LSZH jacket, Standard Compliance: ITU-T G.652.D OS2 Fiber, ISO/IEC 11801, EN50173 -1, ANSI TIA/EIA 568B.All OFC and its Components shall be UL/EN/IEC 60950 compliant and any relevant National/International certification like BIS/NABL or Equivalent shall be submitted for the same\\" Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 492 | Supply, Installation, Testing and comissioning of Core Switch-24x 100/1000 Mbps RJ-45 ports, 4x Dual personaliy GbE ports (SFP 100/1000 Mbps or RJ-45 10/100/1000 Mbps Ports, 4x SFP+ 10G Ports, Support Dual redundant power supply, 136 Gbps Switch fabric speed, , 101.10 Mpps Forwarding Rate , 32K MAC address table, Operation Temperature: 0° to 50° C, L3 Services - IPv4 Routing, RIP v1, v2, OSPF v2 ,L3 Services - IPv6 Routing, Multipath-ECMP, ANSI/UL 60950-1, FCC Part 15 (Class A),CE EMC (Class A) IEC 60950-1,EMC, , iStacking (cluster) up to 24 switches, The OEM Brand should be having valid ISO 9001, ISO 14001, ISO 45001:2018 all these cerificates must be submitted in technical bid. Make Cisco/Juniper/Extreme |
| 493 | Supply, Installation, Testing and Commissioning of 12U 550W x 450D Front Glass Door Single Section Wall Mount Cabinet,IP20 , 75 Kg Loading Capacity,Comply with ANSI/EIA RS- 310-D, DIN41494. IEC 297-2.OEM Should Comply to GFR 2017/Land Border Policy. OEM should be present and directly Registered in India from last 5 Years for Switches & other accessories etc, complete as required. (Make: Valrack/NORDEN/Netrack/Rittal) |
| 494 | Supply Installation, Testing and Comissioning of \\"Supply of 1U 19’” Easy Front Access (EFA) 24 Port Sliding Rack Mount SC duplex type loaded with Single Mode Coupler/Adaptor & Pigtails, Standard Compliance: TSE: EN 61587-1, Equipment - Tests for IEC 60917 and IEC 60297, Climatic and Environment: EN 61587-1/4.2, IEC60068-2-1, IEC60068-2-2, IEC60068-2-30, Earth Bond: EN61587-1/6.2, Flammability: EN61587-1/6.3, RoHS Fiber Coupler/Adaptor: SC Single Mode OS2 Duplex, Phosphor Bronze sleevs, Min 500 Mating Cycles, Standard Compliance: IEC 61300-2-18, IEC 61300-2-19, IEC 61300-2-1, IEC 61300-2-2 Fiber Pigtail: SC Single mode OS2 Simplex, 1.5 meter, LSZH jacket, Standard Compliance: ITU-T G.652.D OS2 Fiber, ISO/IEC 11801, EN50173 -1, ANSI TIA/EIA 568B.All OFC and its Components shall be UL/EN/IEC 60950 compliant and any relevant National/International certification like BIS/NABL or Equivalent shall be submitted for the same\\" Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 495 | Supply, Installation, Testing & Commissioning of Floor mounted 42URACK 800*1000 Loaded Floor Mount Rack with 5 fold pillers welded frame, IP20, Max 900 Kg Loading, Comply with ANSI/EIA RS- 310-D, DIN41494. IEC 297-2, 2-92., Rear Perforated Doors for Server Room deployment Rack Type-42U Floor-mount Heavy-duty Dimensions-800×1000 mm Load Capacity-Max 900 Kg Protection Rating-IP20 Frame Type-5-fold pillars welded Rear Door-Perforated Front Door-Perforated Side Panels-Included Fans- required Casters & Levellers-Required PDU-Zero-U, 12-socket (5/15A), 32A, 7.3 KVA Shelves-1 shelf Cable Manager-Required Mounting Hardware-Pack of 20 UL/CE Certified (Make: Valrack/Netrack/Norden/Rittal) |
| 496 | Supplying, Installation Testing and commissioning of 10KVA online UPS with 42AH Batteries, or as required to have complete solution in all respects and to best statisfaction of engineer in charge.Makes:- APC/Emerson/Numeric |
| 497 | CCTV works |
| 498 | Supply installation Testing and Commissioing of 1/ 2.8 inch or better, CMOS & Progressive Scan and 2MP Dome Camera. 1 ~ 1/32000 s or better, MVF 2.7 ~ 13.5 mm or better, H.265+/H.265, H.264, Color: 0.01 lux @ F2.0/1.6, B/W: 0 lux with IR, Signal-to-Noise Ratio (SNR) 52dB or Better, Defog, Day and Night functionality Automatic, Color , Mono, Internal Illuminator visibility of at least 40 meters,2MP (1920x1080) & 720P (1280x720) @ 25/30 FPS, Wide Dynamic Range Required, Configurable video (H.265+, H.265, H.264) Quad Stream, Perimeter, Crossing line/Tripwire, Motion detection, Tampering/Masking, Compatible Integration ONVIF profile S, G, T & M, SDK/API,SD Card:2TB or Better, SRTP/AES/TLS 256 or Better Encryption Support. The OEM of Camera should not be Banned/Blacklisted because of security concerns anywhere globally. Built in/External Mic Should be supported and provided. '-10°C ~ 60°C. IP67, IK10,NEMA 4X or higher with Built-in Surge Protection (Test reports required for IP67 & IK10). 12 V DC ±10%, PoE, Certifications UL, CE, FCC,OEM Cyber Security Certificate, STQC Compliant BIS-ER .The camera should be certified for web application penetration testing as per OWASP-WSTG V4.2 standard from any lab before the bid publishing date as per STQC directorate. OEM Should Have ISO 9001,14001,27001,45001. Make :Axis/Pelco/Norden/Bosch |
| 499 | Supply installation Testing and Commissioing of Supply1/ 2.8 inch or better, CMOS & Progressive Scan and 2MP Bullet Camera. 1 ~ 1/32000 s or better, MVF 2.7 ~ 13.5 mm or better, H.265+/H.265, H.264, Color: 0.01 lux @ F2.0/1.6, B/W: 0 lux with IR, Signal-to-Noise Ratio (SNR) 52dB or Better,Defog,Day and Night functionality Automatic, Color, Mono, Internal Illuminator visibility of at least 60 meters, 2MP (1920x1080) & 720P (1280x720) @ 25/30 FPS, Wide Dynamic Range Required, Configurable video (H.265+, H.265, H.264) Quad Stream, Perimeter, Crossing line/Tripwire, Motion detection, Tampering/Masking, Compatible Integration ONVIF profile S, G, T & M, SDK/API,SD Card:2TB or Better, SRTP/AES/TLS 256 or Better Encryption Support.The OEM of Camera should not be Banned/Blacklisted because of security concerns anywhere globally. Built in/External Mic Should be supported and provided. '-10°C ~ 60°C. IP67, IK10,NEMA 4X or higher with Built-in Surge Protection (Test reports required for IP67 & IK10). 12 V DC ±10%, PoE, Certifications UL, CE, FCC,OEM Cyber Security Certificate,STQC Compliant BIS-ER .The camera should be certified for web application penetration testing as per OWASP-WSTG V4.2 standard from any lab before the bid publishing date as per STQC directorate.OEM Should Have ISO 9001,14001,27001,45001. Make :Axis/Pelco/Norden/Bosch |
| 500 | Supply Installation, Testing and Comissioning of 24P Managed Ethernet Switch should have total 28 Nos, Gigabit port including 24 Nos. of 10/100/1000 Mbps Ethernet Poe ports and 4 Nos of 10G SFP+, The switch should be flexible enough to be managed through cloud and standalone mode. The cloud managaemnet should be available from Day 1. The Switch should have Non blocking wire speed switch fabric should have min 128 Gbps back plan or more and should have min 95.2 mpps or more, the switch should support min 16 mac addresss or more, the switch should have po power budget of at list 375 w or more. should support EEE i EEE802. 3AZ stand for minimise the power consumpttion on per port basic wire supplying power on the basis of cable lenth and active ports only should support dual softaware(firmware) image, iEEE802, 3 10 based ethernet, 1EEE 802. ab 1000 base t ethernet, 1EEE 802 .3X flow control, IEEE 802.3 10 BASE-T ethernet , i EEE 802.1 P class of service, priority protocols, IEEE 802. 1X Port authentication , IEEE 802.3 AD LACP aggregation, rate limiting : rule based / port based bendwidtch control, 64 KBPS granularity, switch should support jambo farmes of 9KB , switch should support jumbo frames of kb, support IGMP/IGMP snooping V1, V2, V3, IEEE 802.3 AD LACP link aggrejation complete, up to at aggrejetion groups, should support IEEE 802.,1W rapid spanning tree protocol, switch should port protocol based spanning tree protocol (MSTP), should support multiple rapid spanning switch VLAN, ip subnet based, guest VLAN and MVR should support loop guard to avoid loops in network generated on unmanagaed switched, should support AAA thought radius and tacacs + servers, iV6 over ethernet, IPV6 address ICMPV6, dusting, neighbor discovery, Web-based management , SNMP v1, v2c, v3, should have cluster Stacking to manage up to 24 switches by single IP addressm, based on MAC address, VLAN, IP address , protocol TCP/UDP type and DSCP, The OEM Brand should be having valid ISO 9001, ISO 14001, ISO 45001:2018 all these certificates must be submeitted in technical bid. Operating temperature 0 Deg C to 50 deg C. Make Make Cisco/Juniper/Extreme/HPE |
| 501 | Supply Installation, Testing and Comissioning of Category 6 UTP Patch Panel Punch Down 24 Port,Wiring Standards EIA/TIA 568 A/B, Flammability rating UL 94V-0, Safety Rating UL1863 , Transmission ISO/IEC 11801:2002 ANSI /TIA/EIA-568.B.2-10, Category 6 UTP Keystone Jack Un Shuttered Punch Down 180Deg Blue manufactured with an integral cable strain relief,IEEE 802.af, IEEE 802.3at for PoE applications, I/Os Individually replaceable, Rear Cable Manager, Rack Mountable, ISO/IEC 11281, IEC 60603-7, TIA-968-A, Certification: UL, CE. Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 502 | Supply installation Testing and Commissioing of Network Video Recorder of 64Ch Embedded Network Video Recorder with 8 HDD Bays Supports 4K Cameras, RAID, HDMI, VGA and ONVIF.640 Mbps Bandwidth,N+1 Hot Standby,ANR, Network: 2 RJ45, 10M/100M/1000M LAN port, Serial Interface 1xRS232, 1xRS485, Alarm Interface 4 Input & 2 Output, Audio In/Out, Operating temp: -10° to +55° C. Analytics : Abandoned object (Object Left), Missing object (Object Lost), , Video loss, , Abnormal temperature, Hot spare error & Array error, Hard disk R/W error, Hard disk overload, Intrusion (Perimeter)Protocols : P2P, NFS, SSH Certifications: UL, CE, FCC,OEM Cyber Security/Information Security Certificate & BIS, OEM Should Have ISO 9001,14001,45001,27001. Make :Axis/Pelco/Norden/Bosch/ |
| 503 | Supplying, Installation Testing and Commissioning of Core i7 Desktop with 8GB RAM, 512 GB SSD, Windows 11, Wireless keyboard mouse, minimum 2GB Graphic Card, and 43'' LED monitor,Full HD,HDMI port or as required complete in all respects and to the best staisfaction of Engineer-in-charge. Makes:- HP/Dell/Lenovo |
| 504 | Supply, Installation, Testing & Commissioning of Wall mounted 9U enclosure of dimension 600W X9UX500D with front glass door. Single Section Wall Mount Cabinet,IP20 , 30 Kg Loading Capacity,Comply with ANSI/EIA RS- 310-D, DIN41494. IEC 297-2.Double Fan Unit 90 CFM, 230V AC, 50Hz.06 Way x 5/6Amps Indian Round Pin Sockets HPDU, 6A Rocker Switch, 6A Fuse, 5A Plug.1U Base Metal/Loop Metal Horizontal Cable Manager,Mounting Hardware -Pack of 10,Earthing Kit - 2.5 Sq mm, 250mm Length Cable,Wall Mounting Screws –Pack of 4. (Make: Valrack/NORDEN/Netrack/Rittal) |
| 505 | Supply installation Testing and Commissioing of 10TB Surveillance grade SATA Hard disk (Seagate) for continuous recording 1 Month. Make:- Segate/WD/ Toshiba |
| 506 | Supply Installation, Testing and Comissioning of Category 6 1 mtr. Patchcord, 24 AWG Stranded, Unshielded Polycarbonate plug, Gold over Nickel Contacts, LSZH Jacket, 1000 Mating Cycles, Fire rating: IEC 60332-1, Standard Compliance: ANSI/TIA-568-C.2 and ISO/IEC-11801, IEC 61156-2, EN 50173; EN 50288-6-2, Certification: UL, CE, ETL Channel tested for cameras at both ends, switches and servers in control room, complete as required. Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 507 | Supply Installation, Testing and Comissioning Category 6 UTP RJ45 Connector Makes:- Siemon/ Belden/ Panduit/Norden/ CommScope |
| 508 | Supply installation testing and commissioning of 1U 19’” Easy Front Access (EFA) 12 Port Sliding Rack Mount SC duplex type loaded with Single Mode Coupler/Adaptor & Pigtails, Standard Compliance: TSE: EN 61587-1, Equipment - Tests for IEC 60917 and IEC 60297, Climatic and Environment: EN 61587-1/4.2, IEC60068-2-1, IEC60068-2-2, IEC60068-2-30, Earth Bond: EN61587-1/6.2, Flammability: EN61587-1/6.3, RoHS Fiber Coupler/Adaptor: SC Single Mode OS2 Duplex, Phosphor Bronze sleevs, Min 500 Mating Cycles, Standard Compliance: IEC 61300-2-18, IEC 61300-2-19, IEC 61300-2-1, IEC 61300-2-2 Fiber Pigtail: SC Single mode OS2 Simplex, 1.5 meter, LSZH jacket, Standard Compliance: ITU-T G.652.D OS2 Fiber, ISO/IEC 11801, EN50173 -1, ANSI TIA/EIA 568B.All OFC and its Components shall be UL/EN/IEC 60950 compliant and any relevant National/International certification like BIS/NABL or Equivalent shall be submitted for the same\\" Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 509 | Supply Installation, Testing and Comissioning of LC/PC Singlemode OS2 1.5m LSZH Pigtail Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 510 | Supply Installation, Testing and Comissioning of LC/PC-LC/PC Singlemode OS2 3m Duplex LSZH Patch Cord.All OFC and its Components shall be UL/EN/IEC 60950 compliant and any relevant National/International certification like BIS/NABL or Equivalent shall be submitted for the same\\" Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 511 | FIRE alarm component |
| 512 | Supply installation Testing and Commissioing of Addressable manual call point with built-in isolator. LED status indicator and test key. Red color. CPR certificates EN 54-11 and EN 54-17. Dimensions: 98 x 98 x 48 mm. Make-Detnov/Notifier/Gamewell//Edward/Norden |
| 513 | Supply installation Testing and Commissioing of Addressable optical & heat detector, with dirt compensation and algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5 and EN 54-7. Dimensions: 100 x 40 mm. Make-Detnov/Notifier/Gamewell//Edward/Norden |
| 514 | Supply installation Testing and Commissioing of Addressable heat (58°C fixed temperature and thermal rate of rise) detector, with algorithm verification. Led status indicator and output for remote pilot indicator PAD-10 or buzzer BUD-200. White color. Allows installation without polarity. Requires base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5. Dimensions: 100 x 40 mm. Make-Detnov/Notifier/Gamewell//Edward/Norden |
| 515 | Supply installation Testing and Commissioing of Addressable loop sounder with beacon and built-in isolator. Low power consumption. 32 tones and 3 configurable volumes (Low, Medium, High). Acoustic power 76 dBA to 117 dBA depending on the selected tone. It takes just one address in the loop. Red color. IP33C. Deep base. CPR certificate EN 54-3 and EN 54-17. Dimensions: 100 x 75 mm. Make-Detnov/Notifier/Gamewell//Edward/Norden |
| 516 | Supply installation Testing and Commissioing of IP/SIP POE Wall mount Speaker with UL94 V0 rated ABS Casing, Protocol Support : SIP (RFC3261),FTP,HTTP,TCP,RTP,IPv4,UDP,ARP,ICMP,IGMP, SPL : 90dB±3dB, Rated Power Output on POE : 20W with Class D Amplifier integrated, online upgrading and remote management Support.OEM Should Have ISO 9001,14001,27001,45001.Make : Bosch, orden,Commend,Cohesive |
| 517 | Supply installation Testing and Commissioing of Modular addressable fire alarm control panel expandable up to 32 loops, by means of additional 2 loops cards (TBUD-250) and extension boxes (CAD-250-B; CAD-250-BLED). It does not incorporate detection loops. 10\\" touch screen with graphic management. 2048 programmable zones, 256 areas and 1024 groups. 100.000 event history logs, free configuration and maintenance software, USB and Ethenet configuration ports, 2 supervised sounder outputs and 2 free relay outputs. Auxiliary output of 24V 500 mA. Able to be networked up to 64 control panels (T-Network). Ethernet on board for programming and remote maintenance. Connectivity to Detnov Cloud. Metal box. Multilingual. CPR certificate EN 54-2 and EN 54-4. Requires 2 BTD- 1224 batteries (not included). Dimensions: 533 x 453 x 212 mm Make-Detnov/Notifier/Gamewell//Edward/Norden |
| 518 | Supply installation Testing and Commissioing of IP Based PA & Intercom Server Software B/S(Browser/Server) soware architecture for centralized management of all IP intercom and PA devices Creation and scheduling of timed events, alarm events, and customizable event combinations Supports multiple real-time broadcast tasks using server sound card, files, terminals, and speech synthesis Management of broadcasting system through mobile app and user account management, including operation authority settings Integration with third-party VOIP phones using SIP trunk for seamless VOIP system connection Call-log and event-log recording and inquiry features for efficient monitoring Standard HTTP API documentation to facilitate integration with other systems and third-party development. Make : Bosch, Norden,Commend,Cohesive |
| 519 | Supply installation Testing and Commissioing of IP Based Paging Microphone with Touch Screen.2-way communication between paging microphones & intercom terminals. Ports:1x RJ45, 1xUSB, 1xMicro SD card Slot, 1x contact closure input & output,1x3.5mm Audio jack (Line in),1x3.5mm Audio jack (Line out),1x3.5mm Audio jack (Headphone), 1x3.5mm Audio jack (Mic in),Metal Body.Make : Bosch, Norden,Commend,Cohesive |
| 520 | Supply installation Testing and Commissioing of IP Based Fire Alarm Interface Make : Bosch, Norden,Commend,Cohesive |
| 521 | Supply installation Testing and Commissioing of Addressable monitor module with 1 supervised technical input for device status indication providing NC or NO contact. It takes one address in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Non polarity installation. Consumption less than 300μA at rest. Red color.Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18. Make-Detnov/Notifier/Gamewell//Edward/Norden |
| 522 | Supply installation Testing and Commissioing of Addressable control module for 1 relay output, provides one contact C, NO, NC. It takes one address in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Non polarity installation. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18. Make-Detnov/Notifier/Gamewell//Edward/Norden |
| 523 | Supply installation Testing and Commissioing of Wiring with 2 core x 1.5 sq.mm PVC FRLS Armoured. Make Polycab/Delton/Havells/Finolex |
| 524 | Supply installation Testing and Commissioing of MS Junction Box including termination at both ends suitable for Detectors & Modules etc. |
| 525 | Supply installation Testing and Commissioing of Remote indicator for direct connection to 200 and 200A series detectors, installed in enclosed or concealed enclosures. 5mA very low consumption. Dimensions: 80 x 80 x 27 mm. Make-Detnov/Notifier/Gamewell//Edward/Norden |
| 526 | Supply Installation, Testing and Comissioning of Unshielded Twisted Pair, Category 6, 23 AWG solid bare copper, Insulation: High Density Polyethylene, Jacket: FRPVC, Frequency: Tested up to Minimum 250 MHz, Fire Rating: IEC 60332-1, IEC 60754, IEC 61034, Standard Compliance: ANSI/TIA-568 C.2 category 6, ISO/IEC-11801, Class E/ IEC 61156-5: category 6, Certification: UL, CE, ETL Verified in the existing surface/ recessed Steel/PVC conduit/ raceway as required. Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 527 | 1 run of cable |
| 528 | 2 run of cable |
| 529 | 3 run of cable |
| 530 | Supply Installation, Testing and Comissioning of Category 6 UTP Patch Panel Punch Down 24 Port,Wiring Standards EIA/TIA 568 A/B, Flammability rating UL 94V-0, Safety Rating UL1863 , Transmission ISO/IEC 11801:2002 ANSI /TIA/EIA-568.B.2-10, Category 6 UTP Keystone Jack Un Shuttered Punch Down 180Deg Blue manufactured with an integral cable strain relief,IEEE 802.af, IEEE 802.3at for PoE applications, I/Os Individually replaceable, Rear Cable Manager, Rack Mountable, ISO/IEC 11281, IEC 60603-7, TIA-968-A, Certification: UL, CE. Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 531 | Supply Installation, Testing and Comissioning of Category 6 1 mtr. Patchcord, 24 AWG Stranded, Unshielded Polycarbonate plug, Gold over Nickel Contacts, LSZH Jacket, 1000 Mating Cycles, Fire rating: IEC 60332-1, Standard Compliance: ANSI/TIA-568-C.2 and ISO/IEC-11801, IEC 61156-2, EN 50173; EN 50288-6-2, Certification: UL, CE, ETL Channel tested for cameras at both ends, switches and servers in control room, complete as required. Makes:- Siemon/ Belden/ Panduit/Norden/ Commscope |
| 532 | Supply, Installation, Testing & Commissioning of Wall mounted 9U enclosure of dimension 600W X9UX500D with front glass door. Single Section Wall Mount Cabinet,IP20 , 30 Kg Loading Capacity,Comply with ANSI/EIA RS- 310-D, DIN41494. IEC 297-2.Double Fan Unit 90 CFM, 230V AC, 50Hz.06 Way x 5/6Amps Indian Round Pin Sockets HPDU, 6A Rocker Switch, 6A Fuse, 5A Plug.1U Base Metal/Loop Metal Horizontal Cable Manager,Mounting Hardware -Pack of 10,Earthing Kit - 2.5 Sq mm, 250mm Length Cable,Wall Mounting Screws –Pack of 4. (Make: Valrack/NORDEN/Netrack/Rittal) |
| 533 | Supply Installation, Testing and Comissioning of 24P Managed Ethernet Switch should have total 28 Nos, Gigabit port including 24 Nos. of 10/100/1000 Mbps Ethernet Poe ports and 4 Nos of 10G SFP+, The switch should be flexible enough to be managed through cloud and standalone mode. The cloud managaemnet should be available from Day 1. The Switch should have Non blocking wire speed switch fabric should have min 128 Gbps back plan or more and should have min 95.2 mpps or more, the switch should support min 16 mac addresss or more, the switch should have po power budget of at list 375 w or more. should support EEE i EEE802. 3AZ stand for minimise the power consumpttion on per port basic wire supplying power on the basis of cable lenth and active ports only should support dual softaware(firmware) image, iEEE802, 3 10 based ethernet, 1EEE 802. ab 1000 base t ethernet, 1EEE 802 .3X flow control, IEEE 802.3 10 BASE-T ethernet , i EEE 802.1 P class of service, priority protocols, IEEE 802. 1X Port authentication , IEEE 802.3 AD LACP aggregation, rate limiting : rule based / port based bendwidtch control, 64 KBPS granularity, switch should support jambo farmes of 9KB , switch should support jumbo frames of kb, support IGMP/IGMP snooping V1, V2, V3, IEEE 802.3 AD LACP link aggrejation complete, up to at aggrejetion groups, should support IEEE 802.,1W rapid spanning tree protocol, switch should port protocol based spanning tree protocol (MSTP), should support multiple rapid spanning switch VLAN, ip subnet based, guest VLAN and MVR should support loop guard to avoid loops in network generated on unmanagaed switched, should support AAA thought radius and tacacs + servers, iV6 over ethernet, IPV6 address ICMPV6, dusting, neighbor discovery, Web-based management , SNMP v1, v2c, v3, should have cluster Stacking to manage up to 24 switches by single IP addressm, based on MAC address, VLAN, IP address , protocol TCP/UDP type and DSCP, The OEM Brand should be having valid ISO 9001, ISO 14001, ISO 45001:2018 all these certificates must be submeitted in technical bid. Operating temperature 0 Deg C to 50 deg C. Make Cisco/Juniper/Extreme/HPE |
| 534 | Supply installation Testing and Commissioing of Addressable short-circuit protection isolating module, with status LED, which isolates the loop section between two isolators in the event of a short-circuit in the loop. Takes no address in the loop. Direct feed from the loop. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color.Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-17. Make-Detnov/Notifier/Gamewell//Edward/Norden |
| 535 | Supply Installation, Testing and Comissioning Category 6 UTP RJ45 Connector Makes:- Siemon/ Belden/ Panduit/Norden/ CommScope |
| 536 | Fire Fighting |
| 537 | Providing, laying, jointing and testing in following sizes of MS Class 'C' (heavy class) pipes Conforming to IS: 1239/3589 with accessories like fittings including tees, elbows, reducers, flanges gaskets, G.I. nus, blots complete with all accessories as required.Make. TATA, JINDAL HISSAR. |
| 538 | 80 mm |
| 539 | 100 mm |
| 540 | 150 mm |
| 541 | 200 mm |
| 542 | Proviidng ,Installing and commissioning of Frist Aid hose reel with MS Construstion spray painted in post office red (swinging type hose reel drum) Conforming tp IS 884 with upto date amendments complete with 30 mtr long and 20 mm nominal internal dia heavy duty r water hose thermoplastic (Teitile reinforced )type II, 20 mm dia globe valve stop cock. Tetrminating with G.M. coupling & nozzle of 6mm outlet with shut off valve complete as required.Make. Minimax,New age, Ceasefire. |
| 543 | Supply, installation, testing & commissioning of : ss ISI marked odlique pattern hydrant landing valve with 80 mm dia flanged inlet and 63 mm dia instantaneous type female outlet complete with SS cap and G.I. chain, twist release type plug and all accessories as per IS: 5290-1983 (Type 'A')Make. Minimax,New age, Ceasefire. |
| 544 | Providing, fixing of 63 mm dia, 15 mtr long non-percolating flexible hose (RRL- type A) as per IS : 636, Type A with Stainless steel male & female instantaneous type coupling (IS 903).Make. Minimax,New age, Ceasefire. |
| 545 | Providing & fixing 63 mm dia SS Braneh pipe with Stainless Steel with 20 mm (nominal internal dia) Size SS Nozzle with standard inlet instandenous lack type 63 mm dia Coupling Branch Pipe & Nozzle shalll Confirm I.S 903.Make. Make. Minimax,New age, Ceasefire. |
| 546 | Providing &fixing fibre glass reinforced Fire Hose Cabinet ( 30\\"x24\\"x10\\") out door type, made out of sheet having glazed door with 6mm thick clear Glass including necessary Locking arrangement with allen Key, powder coating with Post Office Red Paint and for Hoseing 2 Nos .RRL Hose Pipe, 1 No Branch pipe including grounding and suitable inscripting the words\\" Hose Cabinet\\" on the Box complete as requried. Make. Minimax,New Age ,Ceasfire. |
| 547 | Providing Gunmetal Collecting head with 63 mm dia instantaneous type inlet +150 mm dia flanged outlet with built incheck valve for fire brigade connection to UG Tank +wet riser I.S 904 specification test for 20kg/mm2 including necessary support complete in all respect. Make. Minimax,Atasee,Ceasefire. |
| 548 | FourWay |
| 549 | Providing Cast iron /steel Butterfly Valve Confirming to type P.N 1.6 of I.S 13095-1991 Complete with Flanges bolt ,nuts ,gasket etc. As per table 'E' specification complete in all respect hydraulically test to 20 K./sqcm.Make. Zoloto, Sant,LP. |
| 550 | 80 mm Dia |
| 551 | 100 mm Dia |
| 552 | 150 mm Dia |
| 553 | Providing and fixing Cast Cast Iron/steel double flanged Dual Plate type with gunmetal seat non-return valve confirming to class - I of IS including nuts, bolts, 1.5 mm thick compressed asbestos gasket as per table \\"E\\" and specifications complete in all respect.Make. Zoloto,Sant,LP. |
| 554 | 80 mm dia |
| 555 | 100 mm Dia |
| 556 | 150 mm Dia |
| 557 | supply, Installing, testing and commissioning of 100mm dial type pressure gauge gate valve with all accessories as requried. Make. H.Guru.,SystemSensor,Fbig. |
| 558 | SITC Pressure switchs for Main, Jockey, and staind by Diesel pumps including necessary wiring up to control panel and Ballvalve. complete in all respect. MAKE DANFOSS OR any other make approved by engineer incharge |
| 559 | supply, Installing, testing and commissioning of 25mm dia gate valve with all accessories as requried.Make. Zoloto,Sant,LP. |
| 560 | Providing, fixing, testing and commissioning of MS air cushion tank on top of each riser fabricated form 6mm thick MS plate, 250mm in diameter and 1.2 m in height with dished ends fabricated from 8mm thick MS plate with Air release valve with stop cock, flanged inlet connection and drain arrangement with 25mm dia valve, pressure gauge with gun metal stop cock complete with all accessories as required. |
| 561 | Supplying installation,testing and commissioning of electric driven main fire pump suitable for aotumatic operation and consisting of following complete in all respect as required. |
| 562 | Horizontal type,centrifugal,spilt casingpump of cast iron body and bronze impeller with stainless steel shaft,mechanical seal and farthest outlet at specified flow of 2280 LPM and 88 Metres head conforming to IS 1520 (The pump shuld be capable of delivering 150% rated discharge at a head not less than 65% oftherated head.) |
| 563 | Suitable 75 HP SQ cage induction motor TEFC, Synchronous speed 1500 RPM suitable for operation on 415 volts,3 phase 50 Hz.AC with IP 55 protection for enclosure,horizontal foot mounted type with class \\"F\\"insulation ,conforming to IS-325.Make Kirloskar ,ABB,Cromption. |
| 564 | M.S fabricated common base plate,coupling ,coupling guard, foundation bolts etc.as required. |
| 565 | (D) Suitable RCC pump-Foundations as per manufactures design and 4 nos Dunlop (cushy foot) heavy duty Antivibration mounting pads. |
| 566 | Supply Insllation,testing,and commissioning Jockey pump with 15 HP SQ cage induction motor,TEFC,synchronous speed 2900 RPM,suitable for opreation on 415 volts,3 phase 50 Hz.AC with IP 55 protection for enclosure,horizontal foot mounted type with class \\"F\\"insulation,conforming to IS-325 for 180 LPM and 88 Metres head conforming to IS 1520 bronze impeller/SS and Mechanical seal.MS fabricated common base plate,coupling,coupling guard,CCfoundation etcas requried.Make. Kirloskar,ABB,Cromption. |
| 567 | Supplying installation,testing and commissioning of Diesel Engine Driven Fire pump suitable for aotumatic operation and consisting of following complete in all respect as required. |
| 568 | Horizontal type,centrifugal,spilt casingpump of cast iron body and bronze impeller with stainless steel shaft,mechanical seal and farthest outlet at specified flow of 2280 LPM and 70 Metres head conforming to IS 1520 (The pump shuld be capable of delivering 150% rated discharge at a head not less than 65% of the rated head.) |
| 569 | Suitable 75 HP 1500 RPM deesel engine conforming to IS:649/IS:160/IS10002 all amended upto date, countnuous duty, multi cylinders vertical 4 dtroke cycle water cooled, developing suitable operating speed specified to drive the fire pump capable of driving continous non-stop opreation for 8 hours having 10% overload capacity for one hour in a period of 12 hours continuous run ,capacity to accept full load within 15 seconds from the receipt of signal to start and complete with following accessories.Make Kirloskar,ABB,Cromption. |
| 570 | Dynamically balanced fly-wheel. |
| 571 | Direct coupling for pump and coupling guards. |
| 572 | Radiator with hoses .fan water pump,drivearrangement and guards |
| 573 | Air-cleaner dry type |
| 574 | Fuel tank with necessary pipe. |
| 575 | pump for fabricating oil and lubricating oil filter. |
| 576 | Electric starding system alongwith battery 12 V/24 V |
| 577 | Exhaust siliencer (residentail type) with necessary pipe work. |
| 578 | Governor |
| 579 | Instrument panel housing all the gauges including tachometer,hourmeter and starting switch with key (for manual starting) |
| 580 | Necessary safty control and stop solenoid in the event of fault. |
| 581 | Painted in post office red colour. |
| 582 | Common base plate fabricated out of MS channel of suitable size for assembling the pump and the engine fkexble coupling and with couplingguard for protection/safety. |
| 583 | Fabricating ,Supplying, installation, testing and commissioning of cubical construction floor mounted type, fabricating from 2 mm thick CRCA sheet compartmentalised withhinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection, having swichgear and accessories mounting and internal wiring, earth terminal numbering etc complete in all respect suitable for operation on 415 V .Three Phase, 50 Hz, Ac supply withencloser protection class IP 42 as required. |
| 584 | Incomer |
| 585 | I ) 250 A, 4 Pole, 50 KA, MCCB withmicriprossor release with Ics=Icu digital Volt meter(0-500 Volts) with selector switch digital Ammeter (0-400 Amps) with in built selector switch and CT's etc. Set of 3 phase LED indicating lamps, set of Al. bus bar for 500 Amps |
| 586 | OUTING |
| 587 | Mains Fire pump. |
| 588 | I ) 125 Amps, 4Pole MCCB, 35/36 KA Ics=100% Icu with suitable HP fully automatic star/delta starter with over load protection, current sebsing type single phase preventor complete with all accessories and internalwiring requried for automatic operation, selector switgh for/ remoute, auto /mannul oFF operation-1sets |
| 589 | ii) Digtal ammetre with selector switch alongwith suitable ratio CTs-1 set |
| 590 | iii)Pump on LED Induication Lamp -1 No |
| 591 | b) Jockey pump. |
| 592 | i) 63 Amps. 4P MCCB 25 KA Ics=100% wit hSuitable HP fully automatic star/delta starter with over load protection .(without no volt and under voltage trip), current sebsing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote,auto/manual OFF operation-2 set |
| 593 | ii) Digtal ammetre with selector switch alongwith suitable ratio CTs-1 set |
| 594 | iii)Pump on LED Induication Lamp -1 No |
| 595 | Diesel Engine Control |
| 596 | Control for Diesel Engine Comprising |
| 597 | Auto/ Manaul selector switch and 3 attempt starting device, timers and relays as requried . Push buttions.start/ stop in manual mode. Indication Lamp for High/Low Lub. Oil pressure, High Water Temp, and Engine ON indication. Battery Charger suitable for 12/24 V DC with boost and tickle selector switch, 0-30 V DC volt meter, 0-20 A DC Ammeter . All standard relay and accessories for automatic operation. |
| 598 | d) System Controller |
| 599 | Designing supply, Installation, Testing and Commissioning of system controller to control operation of Main Electric Pump, Diesel Pump, Pressurisation Pump, in Sequence as per specification consisting of relay, timers, sensors,annunciation window for fault indication, complete as per specification |
| 600 | Terrace Pumpset Kirloskar Make pump in back pull out design (end suction type ) having 65 mm suction, 100 mm delivery,CI casing , CI impeller and CS shaft with gland packing arrangement coupled on common baseplate tp kirloskar/ABB/CEL or equivalent (at our option ) make 9.3KW/12.5HP, 2900RPM TEFC sq.cage induction motor suitable for 3 phase,415V,50Hz Ac Supply confirmimg to through suitable flexible coupling ,Total Head 35m, 900 LPM, including carriage of materials, labour, tool and plant through all modes of transportation within all leads and lifts and as per direction of Engineer-in- Charge. |
| 601 | SITC of Cubical type panel fabricated from 2mm thick CRCA sheet wall mountedtype made 1.8SWG IP 42 compartmentalised withhinged locable doors, dust and vermin proof.powder coated of approved shade after 7 tank treatment process,cable alley,inter connection,Incomer 63 amp . TP MCCB with voltmeter.Ampere Meterinbuilt 72 mm meter, Outgoing 12.5 HP DOL Starter and auto/Manual switch with R/Y/B Three phase indication pump running staus indication push buttion start and stop etc. and internal wiring,earth terminal nimbering,suitable 4 wire 415V ac 50 Hz 12.5HP 9.3 KW Dol Starter control wire FR copper conductor etc complete in all respect |
| 602 | Providing & fixing of IS marked (IS:15683) portable fire extinguisher, carbondioxide type flat base including valve, discharge hose of not less than 10 mm dia. 1 M long & complete in all respects including initial fill with CO2 gas confirming to IS:15222 filled to a filling ratio of not more than 0.667 and wall suspension bracket. (ISI MARK) Make .Minimax,Atasee, Ceasefire. |
| 603 | 4.5kg |
| 604 | Providing and fixing Water CO2 9 .Litrs type fire extinguishers consisting of seamless cylindrical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS: 15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. ( ISI MARK) .Make. Minimax, Atasee,Ceasefire |
| 605 | Providing and Fixing 4 Kg. ABC MAP-50% Powder type fire extinguishers are manufactured and marked to Indian standard IS: 15683. Hose shall made of EPDM Rubber, CE Marked Valve, Suitable first aid appliance for fighting fires in Class A, B & C fire that is wood, textile, flammable liquids & gases.Make Minimax,Atasee,Ceasefire. |
| 606 | Supply, Installation, Testing & commissioning of “Y” type stainer in pump suction line.Make:Sant,Zoloto,Leader. |
| 607 | 80 mm dia |
| 608 | 100 mm dia |
| 609 | 150 mm dia |
| 610 | Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheatthed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc.of the required size. |
| 611 | Armoured cable 25 sq. mm ( 3.5 core) |
| 612 | Armoured cable 70 sq. mm ( 3.5 core) |
| 613 | Providing, Installation,Erection, commissioning and testing of 13 passenger electric traction elevator gearless(MRL) complete in all respect and latest safety norms to be erected on iron frame work hoistway as required and conforming the IS-17900 and HP Lift Act 2007 and latest amended in 2026 complete as detailed below: |
| 614 | Capacity :-884 Kgs (13 Passenger) |
| 615 | Speed-1MPS: |
| 616 | Travel (Max.): 16 MTRS Approx |
| 617 | Product Type :- Gearless MRL |
| 618 | Number of Stops:-6 |
| 619 | Number of Openings for Car 6 |
| 620 | Number of same side Landings 6 |
| 621 | Total No. of Landings 6 |
| 622 | Passenger 13 |
| 623 | Elevator Group Simplex |
| 624 | Operation Collective Selective (Full Collective) |
| 625 | Drive Type Closed loop - VF |
| 626 | Floor Designation G,1,2,3,4,5 |
| 627 | Travel Height (mm) 16000 mm |
| 628 | Pit Depth (mm) 1600 |
| 629 | Overhead Height (mm)4500 |
| 630 | Hoistway Width (mm) 2100 |
| 631 | Hoistway Depth (mm) 1800 |
| 632 | CWT Position Side |
| 633 | Car Door Type CENTER OPENING (doors) |
| 634 | Car Enclosure SS Hairline |
| 635 | Car Door Construction SS (2 hrs fire rating) |
| 636 | Car Door Finish SS Hairline |
| 637 | Flooring 20 mm Granamite Flooring Space |
| 638 | Entrance Width Front Side (mm) 800 |
| 639 | Entrance Height Front Side (mm) 2100 |
| 640 | Car Width (mm) 1500 |
| 641 | Car Depth (mm) 1450 |
| 642 | Car Height below False Ceiling (mm) 2300 |
| 643 | Car Panel Thickness (mm) 1.5 mm |
| 644 | Ceiling Type SS hairline finish |
| 645 | Handrail on three Sides |
| 646 | Handrail Finish Stainless Steel Hairline |
| 647 | Car Light 5W LED Light |
| 648 | Ventilation Cross Flow Fan |
| 649 | Landing Door Type Same Side CENTER OPENING (ACO 2P) |
| 650 | Landing Door Construction Standard |
| 651 | Door Panel Thickness 1.5 mm |
| 652 | COP & Display Type Full Ht COP |
| 653 | LOP & Display Type At Ground Floor LCD monochrome type |
| 654 | LOP & Display Type At Other Floors LCD monochrome type |
| 655 | Pit Ladder required |
| 656 | Emergency Backup Required 30 minutes - For Light |
| 657 | Additional features:-1. Combined Luminous Hall Button With Seven Segment Digital Hall Position Indicator At All Floors2. Car Operating Panel With Luminous Floor Buttons InCar3. Seven Segment Digital Car Position Indicators In Car4. Battery Operated Alarm Bell And Emergency Light5. Fireman's Switch6. Overload Warning Device7. Automatic Rescue Device8. Stainless Steel Mirror Finish Handrails on rear car panels9. Infra-Red Screen Sensor10. Over Speed Governor11. 2-way IntercomPress & Speak 12.Auto light & Fan off 13. Sill Angle 14. Sill Support 15. Dot Matrix Led D & P Indicators In Car & Landings - Orange Colour / Push Button - Orange L E D Illumination 16. Full Load Bye pass 17.Floor Annunciator with Music |
| 658 | The prices of complete job as per the specifications above shall be inclusive of steel Items, minor Building work, Scaffolding etc. All sundry fittings, assemblies, accessories, hardware items, foundation bolts, terminal lugs for electrical connections as required, and items which are useful and necessary for proper assembly and efficient working of various components shall be deemed to have been included in this job, whether such items are specifically mentioned in the tender documents or not.The contractor should provide Free Service One Year |
| 659 | Providing AMC for 2 no lifts under item No.1 Under the AMC the supplier shall provide comprehensive maintenance service of the lift including the spares and there shall be no hidden cost. Preventive maintenance. service of the equipment under AMC must be carried out once in fortnight. During the period of AMC service/repair calls are to be attended by the supplier within two hours from the time of such calls. The defective equipment should be repaired on the same day at purchaser's location. In case of major defects requiring the defective card/item/ equipment to be taken to the supplier workshop. It should be returned within a week's time duly repaired and immediate substitute card/item/equipment will be provided by the supplier for the smooth operation of the lifts. The to and fro transportation of the card/item/equipment will be the responsibility of the supplier. Delays in attending the calls and or repairing the defective equipment beyond time limit of one day will attract penalty @ Rs.500/- per day. The bidder will undertake the supplies of necessary Mtc. equipment and spare parts will be made available for all the equipment and the complete system for a period of 5 years on continuing basis with 1st year defect liabiliy period on free of cost and thereafter for four years on paid basis. The bidder shall quote the rates on per year basis. |
| 660 | Total |
| 661 | AMC for 2No. Lifts for the 1st year (Defect libility ) quantity 1 |
| 662 | AMC for 2No. Lifts for the for 2nd year |
| 663 | AMC for 2No. Lifts 3rd year |
| 664 | AMC for 2No. Lifts 4th year |
| 665 | AMC for 2No. Lifts 5th year |
| 666 | AMC for 2No. Lifts 6th year |
| 667 | AMC for 2No. Lifts 7th year |
| 668 | AMC for 2No. Lifts 8th year |
| 669 | AMC for 2No. Lifts 9th year |
| 670 | AMC for 2No. Lifts 10th year Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail