| 1 | Washroom |
| 2 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 3 | P/L, of dry stone soling duly hand packed for foundation and backfilling with ramming, dressing, and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 5 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form work for: Return walls, walls (any thickness) including attached pilaster buttresses, plinth and string course fillets, kerbs and steps etc |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.including all carriage involved complete. |
| 11 | Brick work with common burnt clay selected bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deepcomplete in cement mortar 1:6 (1 cement : 6 coarse sand) including curing complete in: Above plinth level and upto floor V level With Non Modular bricks |
| 12 | Providing and fixing Ist quality ceramic glazed wall/floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 13 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 14 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank incl. all necessary fittings/fixtures complete. |
| 15 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 25mm dia nominal bore |
| 16 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 17 | Providing fixing and placing soil waste, vent pipes 100mm dia of prince quality (B-Type) incl. tees, bends, sockets all necessary fittings/fixtures at required spacing complete in all respects. |
| 18 | Providing and fixing soil, waste and vent pipes 75mm dia PVC (Type B) incl. all bends, tees and other fixtures of approved quality like prince/Vectus or equivalent brand all complete. |
| 19 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1cement :4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) including necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design. With common burnt clay (non modular) bricks of class designation 7.5 with PVC main hole cover at the top all complete. |
| 20 | P/F of CP Fittings of approved brand and quality incl. all necessary fittings/fixtures etc all complete. CP Bib Cock/Angle Valve 15mm |
| 21 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 22 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work. |
| 23 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 24 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 25 | Providing/Fixing of CGI Colour coated (Hi-Rib) profile sheets for roofing including vertical/curved surface fixed with Polymer coated J or l hooks, bolts and nuts 8mm diameter with bitumen and G.I Limpet washers or with G.I Limpet washers filled with white lead, including overlapping of sheets complete (upto any pitch in horizantal/ vertical or curved surface) excluding the cost of purlins, rafters (0.50mm thick) etc incl ridges hips/ valleys 60cm vide of colour GI sheets sheets including cost of screws/ washers all complete and cost and carraiges of materials complete. |
| 26 | P/F of Gully, floor Nahani trape incl. CP Iron grattings or required shape and size with all necessary fixtures/fittings 100mm dia all complete. |
| 27 | P/F of C.P fittings of approved brand and make (Cera, Jaguar,Hindware ) or equavallent brand including all necessary fittings/Fixtures incl. carriages, handling etc all complete Cp Connections |
| 28 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps including white vitrous china pedestal of approved quality and make complete as per the directions of Incharge Engineer.. |
| 29 | Providing and fixing 50 liter capacity water heater Gyser of approved brand of Venus/ Recold including its fixing at desired position complete in all respects. |
| 30 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. |
| 31 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 32 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 25 mm nominal bore |
| 33 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 34 | Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone all complete. Including all carriage complete. |
| 35 | Providing and applying 2mm white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 36 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) Powder coated aluminum (minimum thickness of powder coated 50 microns) all complete. |
| 37 | P/F of aluminum composite pannel ofapproved make(complete job) 3 mm thick. |
| 38 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.) 22.3.1 With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm) With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)all complete. |
| 39 | Providing and fivxing of Aluminium Hardware iteams of approvewd brand and make including necessary fittings/fixtures complete:- 8\\" Handles |
| 40 | 4\\" Handles |
| 41 | 12\\" Door Support |
| 42 | Sliding |
| 43 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 44 | P/L, of dry stone soling duly hand packed for foundation and backfilling with ramming, dressing, and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete |
| 45 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 46 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 47 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) all complete. |
| 48 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 49 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6( 1 cement : 6 coarse sand) incl. Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level all complete. |
| 50 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. |
| 51 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, piers, abutments, pillars, posts and struts |
| 52 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.including all carriage involved complete. |
| 53 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 54 | Providing & laying damp-proof Course 40 mm thick (Coping) with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone agg 12.5 mm nominal size) and curing complete. |
| 55 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) all complete. |
| 56 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) all complete. |
| 57 | Repair of Godown |
| 58 | Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone all complete. Including all carriage complete. |
| 59 | Providing hoisting and fixing trusses/purlins /rafters/posts/ post-plates or like components including cost of screws etc. complete First class Budloo/Fir wood |
| 60 | Dismantling roofing including ridges, hips valleys andgutters etc., and stacking the material within 50 meters lead. |
| 61 | providing wood work in truss : Kiln seasoned and chemically treated hollock wood |
| 62 | Providing/Fixing of CGI Colour coated (Hi-Rib) profile sheets for roofing including vertical/curved surface fixed with Polymer coated J or l hooks, bolts and nuts 8mm diameter with bitumen and G.I Limpet washers or with G.I Limpet washers filled with white lead, including overlapping of sheets complete (upto any pitch in horizantal/ vertical or curved surface) excluding the cost of purlins, rafters (0.50mm thick) etc incl ridges hips/ valleys 60cm vide of colour GI sheets sheets including cost of screws/ washers all complete and cost and carraiges of materials complete. |
| 63 | P/F of 12 mm thick Nordic pine wall paneling (T&G) fully finished & four sides planned,fungus and termite proof (seasoned moisture content 8% to 15% imported type ISO :14001 approved including fixing with head less nails and inclusive all carriages, all taxes of allied material involved (including Budloo wood frame) work by 50 x 50 mm battens not more than 600mm c/c both ways, 12mm thick ply wood and touch wood polishing two or more coats complete in all respects finished work to be measured. |
| 64 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.2 mm thick |
| 65 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @2.20kg/10sqm all complete. |
| 66 | Painting with synthetic enamel paint over priming coat of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 67 | Providing and fixing 35mm thick glazed shutters for doors of Imported wood. including ISI marked Black enamelled MS butt hinges with necessary screws incloding panelling with 12mm pre laminated particle board with decorative lamination on both sides with beadings/ nails as required all complete as per direction of Engineer-in-charge(Imported wood). |
| 68 | providing and fixinf of 4 mm thick fixed glass |
| 69 | Providing and fivxing of Aluminium Hardware iteams of approvewd brand and make including necessary fittings/fixtures complete:-100 mm handles |
| 70 | 250 mm Handles |
| 71 | 100 mm Tower bolts |
| 72 | 150mm Tower bolts |
| 73 | Air Hooks |
| 74 | L-Drop 250 mm |
| 75 | Door Stopper |
| 76 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent all complete.18mm |
| 77 | 1.72 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 78 | Point wiring for switch controlled primary light points with 2 x 1.5 Sq.mm FRLS PVC Insulated multistranded copper wire of standard make dully ISI Marked like ( Polycab or Havells or Paraflex or Anchor etc make ) laid in recessed or surface conduitng system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch of standard make dully ISI Marked like (Havells/Crabtrr(Athena) or Legrand (Myrus)or L&T(Englaza) or GM or Anchor (Panta) or make ) and colour housed in zinc chromate passivated GI boxes with moulded cover plate and including cost of circuit wiring( from DB to first switch in the sub circuit) complete as per specification and as required (Job includes providing of separate wiring for inverter and normal lighting excl. cost of conduits.) . |
| 79 | Wiring for Ceiling fan point with P+N) 2X 1.5 sq.mm FRLS HPVC insulated Copper conductor single core cable in surface / recessed Conduits, 1No. 6Amp modular switch, modular and suitable GI box, Two Module Stepped Type Electronic Fan Regulator of approved ISO/IEC Certified (wire shall be approved before execution of wok by SITE In-charge Engineer strictly as required) including cost of Circuit Wire in 2.55qmm Multi strand Copper wire complete excluding cost of Conduits like Havels or Polycab, Paraflex |
| 80 | Point wiring for 16 Amp Socket out lets Power /Heating in 3x4 sq mm FRLS PVC Insulated multi-stranded copper wire of standard make dully ISI Marked like ( Polycabor Havel’s or Paraflex or Anchor make ) laid through recessed or surface conducting system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 16 amp 6 pin combined shuttered socket out let along with 240 volt 16 Amp control Switch of standard make dully ISI Marked like Havells /Crabtrr (Athena) or Legrand (Myrus)or L&T(Englaza) or GM or Anchor (Panta) make ) and colour housed in zinc chromate passivated GI boxes or PVC with inter connection complete as per specifications and as required.( Excl cost of conduiting ) (Max two points shall be paired in one circuit ) incl circuit wiring from DB to first Switch complete job (Excluding cost of conduits |
| 81 | Point wiring for 6 Amp 5-pin Socket out lets Equipment Points (P+N+E) in 3x 2.5Sq.mm FRLS Sq.mm PVC Insulated multi stranded copper wire of standard make dully ISI Marked like ( Polycab or Havells or Paraflex or Anchor make ) laid through recessed or surface conducting system incl the cost of supplying and fixing modular grid plate mounted flush mounted 2 No's of 240 volts 6 amp 5 pin combined shuttered socket out let along with 2 No's of 6 Amp control Switch of of standard make dully ISI Marked like Havells/Crabtrr(Athena) or Legrand (Myrus)or L&T(Englaza) or GM or Anchor (Panta) make and colour housed in zinc chromate passivated GI boxes or PVC with moulded cover plate and inter connections and including cost of loop earthing with 2.5 sq mm PVC Insulated multistranded copper wire for circuit wiring ( from DB to first switch in the sub circuit) (Max two points |
| 82 | Carriage of Materials from approved source to site fo work by MT.Stone agg. / sand For an average lead of 10Kms |
| 83 | Carriage of brick work avg lead of 48 kms Please Enable Macros to View BoQ information |