| 1 | Providing Staff round o clock and T&P required for Repair / Maintenance & Operation of all type of electrical fixtures, DG sets, Pump sets, Electrical panel, feeder pillar, cable network and other accessories installed at Tikri Khampur. The firm shall porvide minor items i/c all types nuts, bolts, screws, PVC Tape etc. as required at site free of cost.Electrician - 1 Nos.Wireman, Pump & DG Operator - 3Nos.Helper - 3 Nos. |
| 2 | Hiring and installation of 62.5 KVA 3 phase DG set i/c comprehensive maintenance and service in all respect with change over 400 Amp. And accessories as required |
| 3 | Diesel cost for 1 No. DG sets of capacity 62.5 KVA at Work Shop NSM Azadpur. |
| 4 | Supply of 2 X 10 sq. mm size (Armoured) XLPE PVC insulated PVC sheathed aluminum conductor cable of 1.1 KV Grade. |
| 5 | Supply of 4 X 16 sq. mm size (Armoured) XLPE PVC insulated PVC sheathed aluminum conductor cable of 1.1 KV Grade. |
| 6 | Supply of submersible sewage pump of single phase 1 HP 50 hz, 230 volt |
| 7 | Supply of LDPE hose pipe 4\\" suitable for submersible pump of 1 HP |
| 8 | Supply & Fixing of 1.5 ton window AC with all accessorieson rent for complete season for office of Tikri Khampur |
| 9 | 100 watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) |
| 10 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 11 | LED Batten light 36 watt (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 12 | S/F of modular 15/16 A switch on the existing modular plate and switch box i/c connections but excluding modular plate etc as required . |
| 13 | S/F of modular 15/16 socket out let on the existing modular plate and switch box i/c connections but excluding modular plate etc as required . |
| 14 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size up to 35 sq mm (claped with 1 mm thick saddle) on wall surface as required. |
| 15 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submaim wiring/cable as required. |
| 16 | 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 17 | 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable |
| 18 | 4 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable Please Enable Macros to View BoQ information |