| 1 | Disconnecting , taking down & removing carefully the ceiling fan, exhaust fans, wall bracket fans, Pedestal Fans and air circulating fans etc, from existing position, from any height, of any description, any sweep and from any position / locations, sealing cable end, for repairs / servicing / overhauling / painting / numbering etc and hanging / fixing the repaired fans in same position or at position as directed by Engr-in-Charge after , dismantling & opening of the fans, checking serviceability of parts, overhauling by necessary cleaning, oiling & greasing , fixing the serviceable parts in position, removing & replacement of defective/ unserviceable parts, if any, with new parts, reassembling the fans, making necessary adjustment and proper alignment of blades, connecting to existing electric sources with using new 1.5 Sqmm 3 core multistranded PVC insulated copper wire (FRLS) to required length and testing at site to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. Note: - (i) The replacement of defective / non-functional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item.(ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation of fans to & from workshop if required and approved by the Engineer-in-charge for necessary repairs.(iv) Re-metaling of motor shaft, polishing and grinding and making to standard size to matching with GM Bush shall be measured and paid for separately under appropriate item of Sch ‘A’ (v) Writing of fan No. and painting of fans shall be measured and paid for separately under appropriate item of Sch ‘A’ |
| 2 | Taking out & removing old burnt-out windings of electric fans of any description and rewinding of fan motor with appropriate size super enamelled copper wire(Gauge/weight of copper coils shall be as per exisitng fans) as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction including painting of fans of any description (ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan) with applying one coat of synthetic enamel paint (White/grey) by spray machine including preparation of existing decorated surfaces of fans including engraving / painting MES No. on fan in capital letters of height not less than 20 mm on fan body complete as directed Engineer-in-charge for the following Fans:- |
| 3 | Rewinding of motor of ceiling fans 1200/1400 mm sweep complete all as specified and directed. |
| 4 | Ditto but rewinding of motor of exhaust fans of 225 mm sweep complete all as specified and directed. |
| 5 | Ditto but rewinding of motor of exhaust fans of 300 mm sweep complete all as specified and directed. |
| 6 | Ditto but rewinding of motor of exhaust fans of 350 mm sweep complete all as specified and directed. |
| 7 | Ditto but rewinding of motor of exhaust fans of 400 mm sweep complete all as specified and directed. |
| 8 | Ditto but rewinding of motor of exhaust fans of 600 mm sweep complete all as specified and directed. |
| 9 | Ditto but rewinding of motor of air circulating fan/wall mounting fans of 400 mm sweep complete all as specified and directed. |
| 10 | Ditto but rewinding of motor of air circulating fan of 600 mm sweep complete all as specified and directed. |
| 11 | Supplying only ball bearing No 6201 complete all as specified and directed. |
| 12 | Supplying only ball bearing No 6202 complete all as specified and directed. |
| 13 | Supply only gun metal bushes of any description and size to suit existing motor shaft including remetaling grinding & polishing of fan motor shaft to required shape/size complete all as specified and directed. |
| 14 | Supplying and fixing in repairs capacitor of capacity 2.5 mfd (PVC body) in fans of any description and in any position complete all as specified and directed. |
| 15 | Supplying and fixing in repair capacitor of capacity 3.15 mfd (PVC body) in fans of any description and in any position complete all as specified and directed. |
| 16 | M&L in replacement of the exhaust fan motor for 225 mm sweep with all accessories and depositing into AGE E/M Store yard at Vayusenabad of old one complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L in replacement of the exhaust fan motor for 300 mm sweep with all accessories and depositing into AGE E/M Store yard at Vayusenabad of old one complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L in replacement of the exhaust fan motor for 350 mm sweep with all accessories and depositing into AGE E/M Store yard at Vayusenabad of old one complete all as specified and directed by Engr-in-Charge. |
| 19 | M&L in replacement of the exhaust fan motor for 400 mm sweep with all accessories and depositing into AGE E/M Store yard at Vayusenabad of old one complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L in replacement of the exhaust fan motor for 600 mm sweep complete with all accessories and depositing into AGE E/M Store yard of old one complete all as specified and directed by Engr-in-Charge. |
| 21 | Taking out the old unserviceable louvers of any type upto G+1 storey and S&F the exhaust fan louvers to suit 300 mm sweep exhaust fan made out of MS sheet heavy duty of 22 gauge as per sample kept at AGE E/M (AF) Tughlakabad duly applying two coats of paint over one coat of red oxide primer with all necessary fixing materials and making good the disturbed surface of wall both inner and outer side and match with the existing surfaces complete all as specified and directed by Engr-in-Charge.NOTE- Contractor will make all arrangements of safety devices and safety of their workmen and govt property while carying out the work. |
| 22 | Ditto- all as per sl item No 21 but to carry out the work at G+2 & G+3 of approximate height upto 10 metres. |
| 23 | Ditto- all as per sl item No 21 but for 450 mm sweep exhaust fan. |
| 24 | Taking down the old unserviceable exhaust fan from the existing position and M&L in replacement of exhaust fan of 230/250 mm sweep ventilating fan(Plastic/Steel body) speed 1350 rpm and power 60 watts suitable for 230 volts, 50 Hz and deposit the old fan into AGE E/M store yard at Vayusenabad complete all as specified and directed by Engr-in-Charge. |
| 25 | Taking down the old unserviceable exhaust fan from the existing position and Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers with all connected accessories and depositing old fan at AGE E/M store yard complete all as specified and directed by Engr-in-Charge. |
| 26 | Taking down the old unserviceable exhaust fan from the existing position and Supply and fix exhaust fan, plastic body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers with all connected accessories and depositing old fan at AGE E/M store yard complete all as specified and directed by Engr-in-Charge. |
| 27 | S&F in replacement of new ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep, min air delivery 210 CFM with service value 5.00 BEE and taking down and depositing the old ceiling fan at AGE E/M store yard complete all as specified and directed by Engr-in-Charge. |
| 28 | S&F in replacement of new ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 900mm sweep, min air delivery 210 CFM with service value 5.00 BEE and taking down and depositing the old ceiling fan at AGE E/M store yard complete all as specified and directed by Engr-in-Charge. |
| 29 | M&L in replacement of wall fan of 450 mm sweep, 3 blade type, 1440 rpm, 80 watts with 3 speed rating suitable for AC supply, 230 volts, 50 Hz and deposit the old fan into AGE E/M store yard at Vayusenabad complete all as specified and directed by Engr-in-Charge. |
| 30 | Taking out the old unserviceable geyser from the existing position and S&F installation and testing of new Geyser of 25 litres capacity with copper inner tank, 5 star rating suitable for 230 Volts, AC supply, 50 HZ complete with all standard accessories depositing the old geysers at AGE E/M store yard at Vayusena bad complete all as specified and directed by Engr-in-Charge. |
| 31 | Taking down carefully storage type water heater (Geyser) after disconnecting of electric/water connections, removing all scale & dirt by descaling of depositing inner, outer tank & heating elements by HCL or aquat clear pidlite solution, stoppage of minor leaking by soldering/brazing of inner CU tank & replacement of defective/wornout/unserviceable nuts, washers(New components/parts shall be measured & paid separately as supply only herein after) & refixing geyser in its original location including hoisting connecting to water, electrical connection & testing proper functioning of geyser including earthing to the entire satisfaction of Engr-in-Charge for various makes of geysers of following capacity:- Note: Necessary spare parts like Non return valve, stop valve, bib tap/ PVC connection /Copper connections cable, glass wool, element, thermostat, storage tank, geyser assembly, indicator etc shall be measured and paid separately. |
| 32 | 25 litres capacity |
| 33 | 35/50 litres capacity |
| 34 | Supply and replace the heating element with ISI marked element of capacity 1.5/2.0 KW, suitable for 230 volts, AC, 50 Hz single phase power supply of storage type water heaters of compatible type duly making all connections by replacing inter connecting copper conductor cables and removal of the old unserviceable element complete all as specified and directed by Engr-in-Charge. |
| 35 | S&F thermostat suitable for 25/35/50 litres capacity storage type water heaters of size 9/11 inch long with temperature range of 0-90 degree centigrade including removal of old unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 36 | S&F check/non return valve gun metal of size 15mm bore with necessary GI fittings required at site including removal of old one complete all as specified and directed by Engr-in-Charge. |
| 37 | S&F in replacement of stainless steel assembly for housing the Heating element, 6/8/9 Holes type for 50/35/25 litres for storage type Geyser complete all as specified and directed by Engr-in-Charge. |
| 38 | S&F in replacement of stainless steel tank for 25 litres storage type Geyser with MS collar with rated pressure not less than 7 kg/Sq cm as per existing pattern complete all as specified and directed by Engr-in-Charge. |
| 39 | S&F in replacement of stainless steel tank for 35/50 litres storage type Geyser with MS collar with rated pressure not less than 7 kg/Sq cm as per existing pattern complete all as specified and directed by Engr-in-Charge. |
| 40 | S&F in replacement of glass wool for 50/35/25 litres storage type Geyser, as per sample complete all as specified and directed by Engr-in-Charge. |
| 41 | S&F in replacement of safety valve ISI marked suitable for storage type Geyser of capacity 50/35/25 litres, as per sample complete all as specified and directed by Engr-in-Charge. |
| 42 | S&F PVC insulated 3 core copper conductor wire of size 2.5 Sqmm overall PVC sheathed for Geyser connection including taking down old one complete all as specified and directed by Engr-in-Charge. |
| 43 | M&L for PVC insulated 3 core copper conductor wire of size 1.5 Sqmm overall PVC sheathed including taking down old one complete all as specified and directed by Engr-in-Charge. |
| 44 | M&L for indicator lamp suitable for 25/35/50 litres geysers as per the existing sample in green and red colour including taking down old one complete all as specified and as directed by Engr-in-Charge. |
| 45 | M&L for after scrapping, cleaning incl preparation of surface of geyser and painting of Geysers and applying two coats of synthetic enamel paint with machine spray paint including writing the MES number on body of the Geyser duly taking down and refixing the connections, testing and commissioning after painting complete all as specified and as directed by Engr-in-Charge. |
| 46 | S&F of rubber ring gasket made out of superior rubber having holes to suit the hole of bar plate complete all as specified and directed by Engr-in-Charge:- |
| 47 | S&F Bib tap of size 15 mm, PVC body with crutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engr-in-charge. |
| 48 | S&F PVC braided connection of size 15 mm dia , 18\\"/24\\" length with nuts suitable for Hot & Cold water connections of geysers complete all as specified and directed by Engr-in-charge. |
| 49 | Supply only teflon tape PTFE 12 metres long and 19 mm wide complete all as specified and directed by Engr-in-Charge. |
| 50 | Supply only bituminous self adhesive flashing tape of size 10 cm x 5 cm x 1000 cm long Heavy duty, silver or black in colour as per sample complete all as specified and directed by Engr-in-Charge. |
| 51 | M&L for dash fastener and screws suitable for fixing/hanging electric geysers of capacity upto 50 ltrs fabricated with bronze and having 10 mm bore and 150 mm long with internal nails all as per sample kept at AGE E/M office complete all as specified and directed by Engr-in-Charge. |
| 52 | S&F in replacement of canopy for ceiling fan of size 1200/1400mm sweep of any make complete all as specified and directed by Engr-in-Charge. |
| 53 | S&F in replacement of down rod for ceiling fan 1200/1400mm sweep of size 15 mm dia upto 1 .5 mtr long duly painted with approved synthetic enamel paint complete all as specified and directed by Engr-in-Charge. |
| 54 | S&F in replacement of Hanging clamp suitable for the ceiling fan of size 1200/1400mm of any make complete with nuts, bolts, rubber reel and locking pin complete all as specified and directed by Engr-in-Charge. |
| 55 | Taking out the old unserviceable geyser from the existing position and S&F installation and testing of new instant Geyser of 03 litres capacity with copper inner tank,3kw suitable for 230 Volts, AC supply, 50 HZ complete with all standard accessories depositing the old geysers at AGE E/M store yard at Vayusena bad complete all as specified and directed by Engr-in-Charge. |
| 56 | Supply, fixing and testing of anti-suicide fan rod of 20 mm dia, GI tubing medium grade 30cm long as require fixed at site including clamp sand minor works regarding the fixing of rod and disconnection and reconnection of 3 core copper wire complete all as specified and directed by Engr-in-Charge. |
| 57 | Supply, fixing and testing of anti-suicide fan rod of 20 mm dia, GI tubing medium grade 45cm long as require fixed at site including clamp sand minor works regarding the fixing of rod and disconnection and reconnection of 3 core copper wire complete all as specified and directed by Engr-in-Charge. |
| 58 | S&F in replacement Bollard light fitting 10 watt inverted pyramid tripod type, energy saving, environmental friendly, long life aesthetically designed die-cast aluminium landscape luminaires for downward lighting with high power LED as light source with epoxy powder coated black after phosphochromeate treatement height 813mm and width 180mm ,IP65 protection all as specified and directed. Please Enable Macros to View BoQ information |