Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF), Air Force Station, Phalodi Name of Work : REPAIR / MAINT OF LT Cable, LT Panel board and its switchgears at Domestic Area under AFS Phalodi. Contract No: GE (AF) PHALODI/ OF 2026-27 Serial Page No. Bidder Name : SCHEDULE 'A'(BOQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT TEXT # NUMBER TEXT NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER NUMBER # TEXT Srl.No. Item Description Item Code / Make Approx No of Units reqd Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out for laying underground cable in soft/losse soil complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil complete all as specified and directed. |
| 4 | Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 5 | M&L for dry tibba sand in trenches for cushioning to under ground cable spreading, levelling, hand punning complete all as specified and directed.Note- Punned down thickness will be measured for payment purpose. |
| 6 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed. |
| 7 | Disconnecting and Taking out of old LT armored PVC cables of any size/core/any voltage grade from trenches for replacement complete all as specified and directed. |
| 8 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4.0 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 9 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 10 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 11 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 core complete all as specified and directed.Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 12 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and directed.Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 13 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and directed.Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 14 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 core complete all as specified and directed.Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 15 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 core complete all as specified and directed.Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 16 | S& F in replacement Aluminum cable crimping terminal/Lug of size of cable lug 25 sqmm complete all as specified and directed. |
| 17 | S& F in replacement Aluminium cable crimping terminal/Lug of size of cable lug 35 sqmm complete all as specified and directed. |
| 18 | S& F in replacement Aluminium cable crimping terminal/Lug of size of cable lug 50 sqmm complete all as specified and directed. |
| 19 | S& F in replacement Aluminium cable crimping terminal/Lug of size of cable lug 70 sqmm complete all as specified and directed. |
| 20 | S& F in replacement Aluminium cable crimping terminal/Lug of size of cable lug 95 sqmm complete all as specified and directed. |
| 21 | S& F in replacement Aluminium cable crimping terminal/Lug of size of cable lug 120 sqmm complete all as specified and directed. |
| 22 | S& F in replacement Aluminium cable crimping terminal/Lug of size of cable lug 185 sqmm complete all as specified and directed. |
| 23 | S& F in replacement Aluminium cable crimping terminal/Lug of size of cable lug 240 sqmm complete all as specified and directed. |
| 24 | M&L for cutting of road / hardstanding upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable protection pipe line and finished surfaces by extracted material and provided with 150mm thick PCC (1:3:6) type C-2 as top layer to match the existing surfaces and remove surplus extracted material 50 m away complete all as specified and directed. |
| 25 | S&F 50 mm bore tube, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors fro cable protection complete all as specified and directed. |
| 26 | S&F 80 mm bore tube, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors fro cable protection complete all as specified and directed. |
| 27 | M&L for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in LT panel foundation including demolition of old PCC complete all as specified and directed. |
| 28 | M&L for Precast cement concrete block masonary type C1 1:3:6 (20mm graded aggregrate) with solid blocks, exc 10cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 29 | M&L rendering 10mm thick in CM 1:6 on fair faces of brick or concrete surfaces finished even & smooth w/o using extra cement. complete all as specified and directed. |
| 30 | Material and labour for 40mm graded stone aggregate for spreadng/ loose filling under four pole structure, E/M installation and other places complete all as specified and directed. |
| 31 | M&L for making of surface for painting duly scrubing the existing paint and applying two coats of synthetic enamel paint over a coat of red oxide primer for LT panel board/Feeder piller box of any size/type at various location complete all as specified and directed. |
| 32 | M&L for servicing to Outdoor/Indoor type LT panel Board of any capacity/size by replacing pitted portion area not exceeding 1.0 sqm with suitable gauge of MS sheet,welding work,replacement of unservicable door hinges and locking arrangement complete all as specified and directed. |
| 33 | S&F in repair thermal magnetic release MCCB four pole 63 Amps, 25 KA rating,Ics=100% Icu ,415 volts AC , Conforms to IS/IEC 60947-2, Adjustable overload settings: 0.8 - 1.0 x In , Fixed short-circuit settings: 10 x In, complete all as specified and directed. |
| 34 | S&F in repair thermal magnetic release MCCB four pole 100/125 Amps, 36 KA rating,Ics=100% Icu ,415 volts AC , Conforms to IS/IEC 60947-2, Adjustable overload settings: 0.8 - 1.0 x In , Fixed short-circuit settings: 10 x In, complete all as specified and directed. |
| 35 | S&F in repair thermal magnetic release MCCB four pole 160 Amps, 36 KA rating,Ics=100% Icu ,415 volts AC , Conforms to IS/IEC 60947-2, Adjustable overload settings: 0.8 - 1.0 x In , Fixed short-circuit settings: 10 x In, complete all as specified and directed. |
| 36 | S&F in repair thermal magnetic release MCCB four pole 200 Amps, 36 KA rating,Ics=100% Icu ,415 volts AC , Conforms to IS/IEC 60947-2, Adjustable overload settings: 0.8 - 1.0 x In , Fixed short-circuit settings: 10 x In, complete all as specified and directed. |
| 37 | S&F in repair thermal magnetic release MCCB four pole 250 Amps, 36 KA rating,Ics=100% Icu ,415 volts AC , Conforms to IS/IEC 60947-2, Adjustable overload settings: 0.8 - 1.0 x In , Fixed short-circuit settings: 10 x In, complete all as specified and directed. |
| 38 | S&F in repair thermal magnetic release MCCB four pole 320-400 Amps, 36 KA rating,Ics=100% Icu ,415 volts AC , Conforms to IS/IEC 60947-2, Adjustable overload settings: 0.8 - 1.0 x In , Fixed short-circuit settings: 10 x In, complete all as specified and directed. |
| 39 | S&F in repair thermal magnetic release MCCB four pole 630 Amps, 36 KA rating,Ics=100% Icu ,415 volts AC , Conforms to IS/IEC 60947-2, Adjustable overload settings: 0.8 - 1.0 x In , Fixed short-circuit settings: 10 x In, complete all as specified and directed. |
| 40 | S&F in replacement of basic multifunction meters of accuracy class 1.0,0.5,Input voltage measurement range 50-520 VAC, Aux supply 80-300 VAC/DC, CT secondary site selectable 1A / 5A, Flush mounting,measures V, A, F, PF, kW, kVA,complete all as specified and directed. |
| 41 | S&F in replacement LT cable straight through jointing kit heat shrink type of 16 to 50 Sqmm cable size complete all as specified and directed. |
| 42 | S&F in replacement LT cable straight through jointing kit heat shrink type of 70 to 95 Sqmm cable size complete all as specified and directed. |
| 43 | S&F in replacement LT cable straight through jointing kit heat shrink type of 120 to 185 Sqmm cable size complete all as specified and directed. |
| 44 | S&F in replacement LT cable straight through jointing kit heat shrink type of 240 to 300 Sqmm cable size complete all as specified and directed. |
| 45 | S&F in replacement CT coil suitable for Amp metre 100/5 Amp complete all as specified and directed. |
| 46 | S&F in replacement indicating lamp set RYB for phase indication operating 240 Volt 50 Hz AC with new one LED panel mounting type as per existing make and type complete all as specified and directed. |
| 47 | Material and labour for disconnecting LT cable from old unsv changeover switch and S&F new onload manual changeover of 415V,100 Amps capacity 4 pole with sheet metal enclosure box suitable for horizontal or vertical mounting along with terminal Shrouds, Source Separator and Phase Barriers, and reconnection of LT cables in the changeover complete all a specified and directed |
| 48 | Material and labour for disconnecting LT cable from old unsv changeover switch and S&F new onload manual changeover of 415V,200 Amps capacity 4 pole with enclosure box suitable for horizontal or vertical mounting along with terminal Shrouds, Source Separator and Phase Barriers, and reconnection of LT cables in the changeover complete all a specified and directed |
| 49 | Material and labour for disconnecting LT cable from old unsv changeover switch and S&F new onload manual changeover of 415V,400 Amps capacity 4 pole with enclosure box suitable for horizontal or vertical mounting along with terminal Shrouds, Source Separator and Phase Barriers, and reconnection of LT cables in the changeover complete all a specified and directed |
| 50 | Taking out of old unsv LT panel and Supply, installation, testing and commissioning of cubical type LT panel board outdoor type manufactured by a CPRI approved factory, made of CRCA steel sheet of 3.15mm thick ,totally enclosed dust & vermin proof, double leaf door shutter in front side with necessary locking arrangement made and with four side projected slanting roof, duly powder coated of approved shade over one coat of red oxide primer both internally and externally and mounted on MS angle iron 50 mm x 50mm x 6 mm frame work including mounting on PCC platform made out of PCC 1:2:4, type B-1, 450 mm thick all round the panel board (15 cm deep in ground and 300 cm above ground). The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 500 Volt, 3 phase, 50 Hz supply system and shall be complete with and including suitable capacity Aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incoming:- (i) MCCB four pole 250 Amps, 36 KA rating,Ics=100% Icu ,415 volts AC - 01 Nos (ii) 3 phase Digital Ammeter with ,Accuracy Class 1.0, 0.5 ,Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 V AC / DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters, CT/PT site programmable - 01 set, (iii) 3 phase Digital Voltmeter with ,Accuracy Class 1.0, 0.5 ,Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 V AC / DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters, CT/PT site programmable - 01 sett , (iv) LED indicator R-Y-B- 01 SetOutgoing: - (i) MCCB 125 Amps 4 pole, Icu- 25KA - 01 Nos, (ii) MCCB 63 Amps 4 pole, Icu- 25 KA - 05 Nos (4W+1S/By), (iii) MCCB 40 Amps 4 pole, Icu- 25 KA - 01 Nos (For street light), (iv) 4 pole power contactor 40 amps for street light -01 Nos . (d) Digital timer supply voltage110-240V AC,Output Type: 1 C/O (Changeover) SPDT Relay, Display: LCD with 12/24 Hour format. -01 Nos, (Note :1. All the MCCBs must be Thermal & magnetic release type with rating,Ics=100% Icu ,415 volts AC, 2. Necessary approval of drawings of LT feeder pillars to be taken from GE before placing order by the contractor) |
| 51 | Taking out of old unsv LT panel and Supply, installation, testing and commissioning of cubical type LT panel board outdoor type manufactured by a CPRI approved factory, made of CRCA steel sheet of 3.15mm thick ,totally enclosed dust & vermin proof, double leaf door shutter in front side with necessary locking arrangement made and with four side projected slanting roof, duly powder coated of approved shade over one coat of red oxide primer both internally and externally and mounted on MS angle iron 50 mm x 50mm x 6 mm frame work including mounting on PCC platform made out of PCC 1:2:4, type B-1, 450 mm thick all round the panel board (15 cm deep in ground and 300 cm above ground). The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 500 Volt, 3 phase, 50 Hz supply system and shall be complete with and including suitable capacity Aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incoming:- (i) MCCB four pole 125 Amps, 25 KA rating,Ics=100% Icu ,415 volts AC - 01 Nos, (ii) 3 phase Digital Ammeter with ,Accuracy Class 1.0, 0.5 ,Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 V AC / DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters, CT/PT site programmable - 01 set, (iii) 3 phase Digital Voltmeter with ,Accuracy Class 1.0, 0.5 ,Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 V AC / DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters, CT/PT site programmable - 01 sett , (iv) LED indicator R-Y-B- 01 Set, Outgoing: - (i) MCCB 100 Amps 4 pole, Icu- 25KA - 01 Nos, (iii) MCCB 40 Amps 4 pole, Icu- 25 KA - 03 Nos (2W+1S/By), (iv) 4 pole power contactor 40 amps for street light -01 Nos, (d) Digital timer supply voltage110-240V AC,Output Type: 1 C/O (Changeover) SPDT Relay, Display: LCD with 12/24 Hour format. -01 Nos, Note :1. All the MCCBs must be Thermal & magnetic release type with rating,Ics=100% Icu ,415 volts AC2. Necessary approval of drawings of LT feeder pillars to be taken from GE before placing order by the contractor) |
| 52 | Taking out of old unsv LT panel and Supply, installation, testing and commissioning of cubical type LT panel board outdoor type manufactured by a CPRI approved factory, made of CRCA steel sheet of 3.15mm thick ,totally enclosed dust & vermin proof, double leaf door shutter in front side with necessary locking arrangement made and with four side projected slanting roof, duly powder coated of approved shade over one coat of red oxide primer both internally and externally and mounted on MS angle iron 50 mm x 50mm x 6 mm frame work including mounting on PCC platform made out of PCC 1:2:4, type B-1, 450 mm thick all round the panel board (15 cm deep in ground and 300 cm above ground). The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 500 Volt, 3 phase, 50 Hz supply system and shall be complete with and including suitable capacity Aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incoming:- (i) MCCB four pole 125 Amps, 25 KA rating,Ics=100% Icu ,415 volts AC - 01 Nos(ii) 3 phase Digital Ammeter with ,Accuracy Class 1.0, 0.5 ,Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 V AC / DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters, CT/PT site programmable - 01 set (iii) 3 phase Digital Voltmeter with ,Accuracy Class 1.0, 0.5 ,Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 V AC / DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters, CT/PT site programmable - 01 sett (iv) LED indicator R-Y-B- 01 SetOutgoing: - (i) MCCB 63 Amps 4 pole, Icu- 25KA - 02 Nos, (iii) MCCB 40 Amps 4 pole, Icu- 25 KA - 02 Nos (1W+1S/By), (Note : 1. All the MCCBs must be Thermal & magnetic release type with rating,Ics=100% Icu ,415 volts AC, 2. Necessary approval of drawings of LT feeder pillars to be taken from GE before placing order by the contractor) |
| 53 | Taking out of old unsv LT panel and Supply, installation, testing and commissioning of cubical type LT panel board outdoor type manufactured by a CPRI approved factory, made of CRCA steel sheet of 3.15mm thick ,totally enclosed dust & vermin proof, double leaf door shutter in front side with necessary locking arrangement made and with four side projected slanting roof, duly powder coated of approved shade over one coat of red oxide primer both internally and externally and mounted on MS angle iron 50 mm x 50mm x 6 mm frame work including mounting on PCC platform made out of PCC 1:2:4, type B-1, 450 mm thick all round the panel board (15 cm deep in ground and 300 cm above ground). The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 500 Volt, 3 phase, 50 Hz supply system and shall be complete with and including suitable capacity Aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incoming:- (i) MCCB four pole 250 Amps, 36 KA rating,Ics=100% Icu ,415 volts AC - 01 Nos(ii) On load changeover switch 250 Amp , 4 pole 415V AC - 01 Nos(iii) 3 phase Digital Ammeter with ,Accuracy Class 1.0, 0.5 ,Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 V AC / DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters, CT/PT site programmable - 01 set (iii) 3 phase Digital Voltmeter with ,Accuracy Class 1.0, 0.5 ,Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 V AC / DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters, CT/PT site programmable - 01 sett, (iv) LED indicator R-Y-B- 01 SetOutgoing: - (i) MCCB 100 Amps 4 pole, Icu- 25KA - 02 Nos, (ii) MCCB 63 Amps 4 pole, Icu- 25 KA - 02 Nos (1W+1S/By), (iii) MCCB 40 Amps 4 pole, Icu- 25 KA - 01 Nos (For street light), (iv) 4 pole power contactor 40 amps for street light -01 Nos , (d) Digital timer supply voltage110-240V AC,Output Type: 1 C/O (Changeover) SPDT Relay, Display: LCD with 12/24 Hour format. -01 Nos Note : 1. All the MCCBs must be Thermal & magnetic release type with rating,Ics=100% Icu ,415 volts AC, 2. Necessary approval of drawings of LT feeder pillars to be taken from GE before placing order by the contractor) |
| 54 | Taking out of old unsv LT panel and Supply, installation, testing and commissioning of cubical type LT panel board outdoor type manufactured by a CPRI approved factory, made of CRCA steel sheet of 3.15mm thick ,totally enclosed dust & vermin proof, double leaf door shutter in front side with necessary locking arrangement made and with four side projected slanting roof, duly powder coated of approved shade over one coat of red oxide primer both internally and externally and mounted on MS angle iron 50 mm x 50mm x 6 mm frame work including mounting on PCC platform made out of PCC 1:2:4, type B-1, 450 mm thick all round the panel board (15 cm deep in ground and 300 cm above ground). The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 500 Volt, 3 phase, 50 Hz supply system and shall be complete with and including suitable capacity Aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incoming:- (i) MCCB four pole 320 Amps, 36 KA rating,Ics=100% Icu ,415 volts AC - 01 Nos(ii) 3 phase Digital Ammeter with ,Accuracy Class 1.0, 0.5 ,Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 V AC / DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters, CT/PT site programmable - 01 set , (iii) 3 phase Digital Voltmeter with ,Accuracy Class 1.0, 0.5 ,Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 V AC / DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters, CT/PT site programmable - 01 sett , (iv) LED indicator R-Y-B- 01 SetOutgoing: - (i) MCCB 100 Amps 4 pole, Icu- 25KA - 02 Nos, (ii) MCCB 63 Amps 4 pole, Icu- 25 KA - 02 Nos (1W+1S/By), (iii) MCCB 40 Amps 4 pole, Icu- 25 KA - 04 Nos (01 For street light), (iv) 4 pole power contactor 40 amps for street light -01 Nos, (d) Digital timer supply voltage110-240V AC,Output Type: 1 C/O (Changeover) SPDT Relay, Display: LCD with 12/24 Hour format. -01 Nos (Note : 1. All the MCCBs must be Thermal & magnetic release type with rating,Ics=100% Icu ,415 volts AC, 2. Necessary approval of drawings of LT feeder pillars to be taken from GE before placing order by the contractor) |
| 55 | Taking out of old unsv LT panel and Supply, installation, testing and commissioning of cubical type LT panel board outdoor type manufactured by a CPRI approved factory, made of CRCA steel sheet of 3.15mm thick ,totally enclosed dust & vermin proof, double leaf door shutter in front side with necessary locking arrangement made and with four side projected slanting roof, duly powder coated of approved shade over one coat of red oxide primer both internally and externally and mounted on MS angle iron 50 mm x 50mm x 6 mm frame work including mounting on PCC platform made out of PCC 1:2:4, type B—1, 450 mm thick all round the panel board (15 cm deep in ground and 300 cm above ground). The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 500 Volt, 3 phase, 50 Hz supply system and shall be complete with and including suitable capacity Aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incoming:- (i) MCCB four pole 160 Amps, 36 KA rating,Ics=100% Icu ,415 volts AC - 01 Nos(ii) 3 phase Digital Ammeter with ,Accuracy Class 1.0, 0.5 ,Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 V AC / DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters, CT/PT site programmable - 01 set, (iii) 3 phase Digital Voltmeter with ,Accuracy Class 1.0, 0.5 ,Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 V AC / DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters, CT/PT site programmable - 01 sett, (iv) LED indicator R-Y-B- 01 Set Outgoing: - (i) MCCB 63 Amps 4 pole, Icu- 25 KA - 05 Nos (4W+1S/By), (ii) MCCB 40 Amps 4 pole, Icu- 25 KA - 01 Nos (01 For street light), (iii) 4 pole power contactor 40 amps for street light -01 Nos , )d) Digital timer supply voltage110-240V AC,Output Type: 1 C/O (Changeover) SPDT Relay, Display: LCD with 12/24 Hour format. -01 Nos Note :1. All the MCCBs must be Thermal & magnetic release type with rating,Ics=100% Icu ,415 volts AC, 2. Necessary approval of drawings of LT feeder pillars to be taken from GE before placing order by the contractor) |
| 56 | Taking out of old unsv LT panel and Supply, installation, testing and commissioning of cubical type LT panel board outdoor type of size not less than 1000x1200x250mm(LxBxW) manufactured by a CPRI approved factory, made of CRCA steel sheet of 3.15mm thick ,totally enclosed dust & vermin proof, double leaf door shutter in front side with necessary locking arrangement made and with four side projected slanting roof, duly powder coated of approved shade over one coat of red oxide primer both internally and externally and mounted on MS angle iron 50 mm x 50mm x 6 mm frame work including mounting on PCC platform made out of PCC 1:2:4, type B—1, 450 mm thick all round the panel board (15 cm deep in ground and 300 cm above ground). The size of panel boards shall be suitable for housing the accessories given here under and also suitable for operation on AC 500 Volt, 3 phase, 50 Hz supply system and shall be complete with and including suitable capacity Aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories:- Incoming:- (i) MCCB four pole 200 Amps, 36 KA rating,Ics=100% Icu ,415 volts AC - 01 Nos(ii) 3 phase Digital Ammeter with ,Accuracy Class 1.0, 0.5 ,Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 V AC / DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters, CT/PT site programmable - 01 set , (iii) 3 phase Digital Voltmeter with ,Accuracy Class 1.0, 0.5 ,Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 V AC / DC, CT secondary site selectable 1A / 5A, Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters, CT/PT site programmable - 01 sett , (iv) LED indicator R-Y-B- 01 SetOutgoing: - (i) Aluminium bus bar of capacity 1.5 times of incoming MCCB ( Not less than 300 Amps) R Y B N (Note : 1. All the MCCBs must be Thermal & magnetic release type with rating,Ics=100% Icu ,415 volts AC, 2. Necessary approval of drawings of LT feeder pillars to be taken from GE before placing order by the contractor) |
| 57 | Material and labour for disconnecting LT cable of any size from structure / pole / transformer for finding fault , Material and labour for defect rectification LT cable laid in trenches or any location by locating fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. The entire repair work to be completed with in 12 hours of instruction from Engr-in-charge as specified. NOTE :- Fault locating with electronic fault locator, excavation and earth work for making joint and cable underground, disconnecting and reconnecting both end of cable, deemed to be included in the quoted rate all as specified and directed by Engr-in-charge. |
| 58 | Labour only for taking down of cable and relaying in trenches as per existing cable of any size complete all as specified and as directed.Note : Earthwork shall be measured and paid seprately under respective item of schedule. |
| 59 | M&L for Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x 6mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized GI strip 25X4mm by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 40 mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testing on completion including dismantling of old earth plate complete all as specified and directed. Note: (i) Rate of excavation, earthwork, charcoal, PCC pit is covered under this item.(ii) The unit rate includes for protection pipe and GI strip 25 x 4mm from top of earth plate up to 7.5 meter above ground level. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail