| 1 | Taking down carefully with battens/ PVC surface/ concealed conduit unserviceable copper/ aluminium point wiring (light, fan, socket) complete including fittings such as switches, ceiling roses, pendants, socket etc. and removing unserviceable material from site and making good disturbed surfaces of walls, floors etc. complete all as specified and directed. |
| 2 | M&L for point wiring PVC insulated sheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover for mounting switches, sockets,fan regulators etc including all necessary wall cutting chasis and making good disturbed surfaces in cement mortar 1:3 and as per existing colour of white wash / paint / OBD / cement base paint complete all as specified and as directed. |
| 3 | All as per item No. 2.00 here-in-before but point wiring for one 5Amps socket outlet point on independent board controlled by one single pole, one way switch with cable /wire 1.5smm size complete all as specified and directed. |
| 4 | All as per item No. 2.00 here-in-before but point wiring for one 5Amps socket outlet point on same board controlled by one single pole, one way switch complete all as specified and directed. |
| 5 | All as per item No. 2.00 here-in-before but point wiring for one bell point controlled by one single pole, one way bell push with cable 1.5smm complete all as specified and directed. |
| 6 | All as per item No. 2.00 here-in-before but point wiring using 2.5 sqmm as main wire & 2.5 Sqmm as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified and directed. |
| 7 | All as per item No. 2.00 here-in-before but point wiring using 4 sqmm as main wire & 4 Sq mm as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified and directed. |
| 8 | Point wiring PVC insulated unsheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm (nominal area) in the existing conduit medium grade including fittings and accessories, one run of continuous single core copper cable of 1.5 Sq. mm connecting to common earth dolly, using the existing pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover/ modular sheet cover for mounting of conventional/ modular switch/ sockets/ fan regulators etc. & making good to disturbed surface area for the one light/ fan point controlled by one single pole, one way switch complete all as specified. |
| 9 | All as per item No. 8.00 here-in-before but point wiring for one 5 Amps socket outlet point on independent board controlled by one single pole, one way switch with cable /wire 1.5 sqmm size complete all as specified and directed. |
| 10 | All as per item No. 8.00 here-in-before but point wiring for one bell point controlled by one single pole, one way bell push with cable 1.5smm complete all as specified and directed. |
| 11 | All as per item No. 8.00 here-in-before but point wiring using 2.5 sqmm as main wire & 2.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified and directed. |
| 12 | All as per item No. 8.00 here-in-before but point wiring using 4sqmm as main wire & 4 Sqmm as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified and directed. |
| 13 | Material and Labour for point wiring surface type with 3 x 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLSH copper conductor cable (phase, neutral & earth wire), earth wire shall be connected to common earth and earth duly with suitable copper lugs drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, 1.60 mm thick GI metal flush box with plastic laminated sheet cover or surface mounting plastic/ PVC boxes suitable for modular/ conventional switches/ sockets/ fan regulators with cover plates (modular/ conventional type as required), blanking plates, brass screws, cup washers, gypsum screws and connected items including all cutting/ chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and as directed for the followings. |
| 14 | One light point controlled by one switch. |
| 15 | One ceiling/exhaust/wall fan point controlled by one switch. |
| 16 | One socket outlet 5 amps point on the same board with other switches. |
| 17 | One socket outlet 5 Amps point controlled by one switch on independent board. |
| 18 | All as per serial item No 13.00 above but with 3 x 2.5 Sqmm nominal cross sectional area copper conductor cable for one 16 Amps socket outlet point on independent board complete all as specified and directed. |
| 19 | All description as per srl item No 13.00 but point wiring with size of cable 4 sqmm for industrial socket outlet 3 pin 16 / 20 Amps point complete all as specified and directed. |
| 20 | Supply and Fix in repairs modular Switch, single module, 6 Amp, one way, ISI marked, fire retardant, specification as per existing make and model complete all as specified and as directed. |
| 21 | All as per serial item no 20.00 above but 16A complete all as specified and directed. |
| 22 | Supply and Fix modular socket outlet 2-in-1, 3 pin, 6/16 Amp, two module, shuttered socket, specification as per existing make and model complete all as specified and as directed. |
| 23 | All as per serial item no 22.00 above but socket, 6A, 3 pin combined 2 module complete all as specified and as directed. |
| 24 | Supply and Fix modular step type fan regulator high speed, dust free glossy finish pure white color, 120 watt, 150-270V, 50Hz two module socket type complete all as specified and directed. |
| 25 | All as per serial item no 24.00 above but one module complete all as specified and as directed. |
| 26 | Supply and Fix modular Bell push 6 Amp 230 volt, one module complete all as specified and directed. |
| 27 | Supply and Fix modular switch, 6 Amp 230 volts single pole, 2 way, one module complete all as specified and directed. |
| 28 | Supply and Fix modular white cover plate and with frame 12 module suitable for fixing of modular switches/sockets complete all as specified and directed. |
| 29 | All as per serial item no 28 above but 8 module complete all as specified and as directed. |
| 30 | All as per serial item no 28 above but 6 module complete all as specified and as directed. |
| 31 | All as per serial item no 28 above but 3/4 module complete all as specified and as directed. |
| 32 | All as per serial item no 28 above but 1/2 module complete all as specified and as directed. |
| 33 | Supply and Fix in repairs modular Switch socket outlet combination with PVC box, multipurpose 3 pin, 16 amp and one pin, 6 amp controlled by one switch complete all as specified and as directed. |
| 34 | Supply and Fix in repairs modular switch socket combination with suitable pvc box 5A, 3 pin, 3 module complete all as specified and as directed. |
| 35 | Supply and fix in repair switch piano, flush type, single pole, one way, 5 Amp, 230 volts complete all as specified and directed. |
| 36 | All as per serial item no 35.00 above but 6A, 2 way complete all as specified and as directed. |
| 37 | Supply and fix in repair switch Bell push, flush type, single pole, one way, 230 volts complete all as specified and directed. |
| 38 | Supply and fix in repair switch piano, flush type, single pole, one way, 15 Amp 230 volts complete all as specified and directed. |
| 39 | Supply and fix in repair Socket outlet multipurpose 3 pin 5 Amp & 15 Amp, flush type, complete all as specified and directed. |
| 40 | Supply and fix in repair Fan regulator electronic,100W, rotory step type, one module, suitable for 1200mm /1400mm sweep ceiling fan, fixed in repairs, with and including provision of PVC flexible cable of size 1sqmm copper conductor as required, complete all as specified and directed. |
| 41 | Supply and Fix ceiling rose, 6 Amps, 230 volts, AC with three terminals and PVC/ Polycarbonate insulated body of size as per site requirement complete all as specified and directed. |
| 42 | Supply and Fix in repairs switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type complete all as specified and as directed. |
| 43 | All as per item no. 42 here in before but Switch socket combination 2 in 1, 6A flush type complete all as specified and as directed. |
| 44 | Supply and Fix in repairs precut/ customized bakelite/hylum sheet, 3mm thickness of size 5x5 inches (1 to 3 module) with extra length machine screws as per site requirement complete all as specified and as directed. |
| 45 | All as per serial item no 44 above but suitable for 4 to 6 module complete all as specified and as directed. |
| 46 | All as per serial item no 44 above but suitable for 8 to 12 module complete all as specified and as directed. |
| 47 | Supply and fixing modular multipurpose socket combined with 25 amp MCB SP, 1.20 mm thick GI metal flush box or surface mounting plastic/ PVC box suitable for modular sockets with cover plates (modular type), blanking plates, brass screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing including taking down old/ unsv sheet metal enclosure or modular socket complete all as specified and directed. |
| 48 | Supply and Fix PVC Non metallic conduit of external dia 20 mm medium grade including of all tees, bends elbow, reducers bell mouth tube end and fixing accessories such as coupler, lock nuts, tie, saddles, pipe hooks etc but exclusive of junction boxes complete all as specified and directed. |
| 49 | All as per Srl item No 48 but 25 mm dia complete all as specified and as directed. |
| 50 | Supply and fix in repair Call bell, electric Ding - Dong type (Domestic pattern), 230 volt, single pole, complete all as specified and directed. |
| 51 | Supply and Fix in repair wall mounted LED batten 22 watt (LxWxH- 1144mm X 25mm X 35mm) with epoxy powder coated white extruded aluminium channel housing for efficient heat dissipation, lumen efficacy of 125lm/W, radiation free, mercury free, glare-free efficient light distribution, white coloured ABS end caps, electronic driver, 140-270 Volt, THD<10%, mounting into the wall/ ceiling by SS clips with all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 52 | All as per Srl item No 51 here-in-before but LED batten 10 watt (LxWxH- 581mm X 25mm X 35mm) complete all as specified and directed. |
| 53 | Supply and Fix in replacement LED Recess mounted 2x2 ft (595mm X 595mm and ht 70mm or as per site requirement) luminaire fitting LED 34/36 Watt CRCA powder coated with lumen efficacy of ≥140 lm/W, cct 3000 to 6500K (as per site requirement), radiation free, longlife, environment friendly, mercury free, symmetric/ uniform light distribution, operating voltage 140V-270V, 50/60 Hz, powered by an independent isolated, SELV output electronic LED driver, pf >0.9, THD<10%, pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including clamps and nut bolts for fixing as per requirement at site complete all as specified and directed. |
| 54 | All as per srl item no 53 but LED Surface mounted 1x1 ft (295mm X 295mm X 70mm) luminaire fitting LED 18 Watt as per site requirement complete all as specified and as directed. |
| 55 | Supply and Fix in repair LED Bulkhead luminaire 20 watt of polycarbonate housing and enclosed with acrylic diffuser, waterproof including all connections as per existing at site complete all as specified and as directed. |
| 56 | Supply and Fix in replacement of energy efficient LED round (dia as per site requirement) recess/surface mounted downlight fitting 18 Watt, 140V-270V, 3000 K to 6500 K couler temp, white powder coated, aluminium heat sink with efficacy of ≥140 lm/W, symmetrical light distribution, powered by an independent, isolated, SELV output electronic driver, snap fixed on the fixture, pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire as per existing at site complete all as specified and as directed. |
| 57 | Supply and Fix in repair LED 10 watts IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution garden light fitting with robust design and efficient light distribution including light fitting fixing and making PCC block foundation and connecting the fittinngs on PCC foundation block including taking out old complete all as specified and directed. |
| 58 | Material and Labour for service cable 4 Sqmm 3 core 1100 volts grade heavy duty cable PVC insulated stranded copper conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections/perimeter light supply as per site requirement, flat or circular complete all as specified and directed. |
| 59 | All as per Srl item No 58 here-in-before but 2.5 sqmm 3 core complete all as specified and directed. |
| 60 | All as per Srl item No 58 here-in-before but 1.5 sqmm 3 core complete all as specified and directed. |
| 61 | All as per Srl item No 58 here-in-before but 0.75 sqmm 2 core complete all as specified and directed. |
| 62 | Supply and Fix in repair decorative type wall mounted antique brass fitting and glass, two lamp wall light, incandescent type LED bulb with base, cct 3000 to 6500K (as per site requirement), symmetric/ uniform light distribution, operating voltage 140V-270V, 50/60 Hz, pf >0.9, THD<10%, push button type controller, pre-wired and electric connection with suitable size of stranded copper flexible PVC insulated wire including clamps and nut bolts for fixing as per requirement at site complete all as specified and directed. |
| 63 | Supply and fix in repair indirect post top for garden & landscape lighting of min 25 watts with IP 65 protection, 140-270V, pole dia 50mm, efficacy > 100 lm/W, CRI 70, canopy spun aluminiuum powder coated in matt finish, diffuser - high performance optical grade PC inside and outside acrylic, internal wiring - 0.5 sq mm teflon coated mains terminal - 3 way 5 Amps for internal connection, surge arrestor - 4 KV inbuilt in driver and 10KV External inside housing, resistant to impact and corrosion, anti Glare and uniform distribution complete all as specified and directed. |
| 64 | Supply and fix in repair Sheet metal enclosure (DB) single phase & neutral, double door 4 way, 240 volt with 200 Amps rated bus bar & IP 54 protection, complete all as specified and directed. |
| 65 | All as per item No.64.00 here-in-before but DB 8 way complete all as specified and directed. |
| 66 | All as per item No.64.00 here-in-before but DB 12 way complete all as specified and directed. |
| 67 | Supply and fix in repair Sheet metal distribution board TPN/VTPN, with double door,4 way, 415 volt with 200 Amps rated bus bar neutral link, blanking plates and having provision of MCCB upto 200 amp, 4 Pole as incomer and MCBs SP/TP as outgoing as per IS, having IP-43 protection, complete all as specified and directed. |
| 68 | All as per item No.67 here-in-before but DB 8 way complete all as specified and directed. |
| 69 | Supply & Fixing in repairs MCCB, 4-pole, breaking capacity 16 KA, 415 volts, 125 Amps complete all as specified and as directed. |
| 70 | Supply & Fixing in repairs MCCB, 4-pole, breaking capacity 16 KA, 415 volts, 100 Amps complete all as specified and as directed. |
| 71 | Supply & Fixing in repair MCCB, 4-pole, breaking capacity 16 KA, 415 volts, 63 Amps, complete all as specified and as directed. |
| 72 | Supply & Fixing in repairs TPN 100A Breaking capacity 10 KA, 415 volts, complete all as specified and as directed. |
| 73 | Supply and fix in repair TPN 63A , breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified and directed. |
| 74 | Supply and fix in repair MCB 40 Amp, 415 Volt, TP, breaking capacity 10 KA, 'B' curve, complete all as specified. |
| 75 | Supply and fix in repair MCB SPN 32/ 40 Amp, 230 Volt, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified and directed. |
| 76 | Supply and fix in repair MCB 6 to 32 Amp, 230 Volt, SP, breaking capacity 10 KA, 'B' curve, complete all as specified and directed. |
| 77 | Material and labour for Sub Main Wiring (in replacement) with two single core 2.5 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC conduit/pvc casing caping of suitable size with and including one run of continuous multi stranded copper conductor 2.5 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 2.5 Sqmm main cable + one run of 2.5 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre. |
| 78 | All as per item No.77.00 here-in-before but size 4 sqmm complete all as specified and directed. |
| 79 | All as per item No.77.00 here-in-before but size 6 sqmm complete all as specified and directed. |
| 80 | Supply and Fix in repair Plug top, 3 pin, 6 Amps, 230 volt complete all as specified and directed. |
| 81 | All as per srl item no 80.00 but 16 amp complete all as specified and directed. |
| 82 | Taking down Air termination, single pointed aluminium rod 12 mm dia and 300mm long including galvanised iron pipe complete all as specified and as directed. |
| 83 | Supply and Fix Air termination, single pointed aluminium rod 12 mm dia and 300mm long complete all as specified and as directed. |
| 84 | Fixing only Air termination, single pointed aluminium rod 12 mm dia and 300mm long retrieved against item No 82 herein-before complete all as specified and as directed. |
| 85 | Taking down Aluminium strip 25x3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and as directed. |
| 86 | Supply and Fix Aluminium strip 25x3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and as directed. |
| 87 | Fixing only Al strip 25x3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground retrieved against item No 85 herein-before complete all as specified and as directed. |
| 88 | Supply and Fix Test Point Terminal Block made of Gun metal or Phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex. Head screws complete all as specified and as directed. |
| 89 | Supply and Fix steel tubing galvanised (light grade) 32mm bore fixed to walls, ceilings or laid in floors complete all as specified and as directed. |
| 90 | Material and Labour for plain cement concrete (1:2:4) type B-1, using 20 mm graded mechanically crushed stone aggregates as in lintels upto 1.5m span, cills, steps, seismic and other similar bands, plinth courses, string courses, ccoping, kneelers, apex stones, bed plates etc slightly rounded or chamferred angles and throating etc with and including use and waste of form work complete all as specified and as directed. |
| 91 | Material and Labour for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron earth strip 32x6mm (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm bore, and watering pipe 20mm bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and as directed.Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include GI strip/wire and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately.(iv) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt. |
| 92 | Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed. Note : Old meter shall be deposited in MES Store. |
| 93 | All as per item No.92.00 here-in-before but 3phase, 415 volt complete all as specified and directed. |
| 94 | Supply and fixing in repair LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 95 | Supply and fix FLP exhaust fan, aluminium body AC single Phase. 230V of size 300m sweep with blades and frame and louvers, 1440rpm, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection complete all as specified and as directed.Note : Old exhaust fan shall be deposited in MES Store. |
| 96 | Disconnecting & taking down complete ceiling fan with blade of any make 1200 mm / 1400 mm sweep from fan hook/ fan box, transporting to local workshop , opening, cutting and taking out complete copper winding , cleaning with kerosene oil /diesel/ terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge and number of turns as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff/strip type) replacing u/s providing paper insulation (cuff / strip type) replacing u/s / missing spare (bush, bearing, capacity shackle insulator, canopy, nuts , bolts, earthing , screw, upper, socket, CI block , quarter /split pin (top & bottom) , lock nut etc) fixing the stator in rotor properly aligned and resembling ensuring right DOR, speedy and noiseless running and connecting cable and refixing after repair complete all as specified and directed.Note: Bush, bearing, capacitor, fan clamps with nuts and bolts shall be measured and paid for separately as supply only. Any other items required for smooth functioning will be provided by contractor without extra cost to the govt. |
| 97 | Supply only in repair capacitor 2.50 MFD, 440 Volt AC, 50 Hz plastic body powder filled type complete all as directed. |
| 98 | Supply only in repair capacitor 3.15 MFD, 440 Volt AC, 50 Hz plastic body powder filled type complete all as directed. |
| 99 | Supply only in repair MS fan clamps with rubber real including nuts and bolts, split pin suitable for ceiling fan 1200 / 1400 mm sweep complete all as directed. |
| 100 | Supply only in repair bearing suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed. |
| 101 | Supply only in repair bush suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed. |
| 102 | Supply & fixing in repair for Mild Steel Down Rod of suitable dia , 45 Cms long white or coloured, compatible to existing ceiling fans of 1200mm or 1400 mm sweep complete all as specified and directed. |
| 103 | Disconnecting & taking down (burnt) exhaust fan of any make upto 450mm sweep transporting to local workshop, opening, cutting and taking out complete copper winding , cleaning with kerosene oil / diesel/ terpin oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff /strip type) replacing u/s / missing spare (bush, bearing , capacity etc) fixing the stator in rotor properly aligned and reassembling ensuring right DOR , speedy and noiseless running and refixing after repair complete all as specified and directed. Note: Bush bearing capacitor shall be measured and paid for separately. |
| 104 | Supply and fix in repair capacitor 4/6 MFD, 440 Volt AC, 50 Hz plastic body powder filled type for exhaust fan of 300/400/450mm sweep complete all as specified and directed. |
| 105 | Supply only bearing suitable for 300 / 400/ 450 mm sweep Exhaust fan complete all as specified and directed. |
| 106 | Material and Labour for Spray painting of Exhaust/ ceiling fan and testing at site full load with super enamelled heat resistant synthetic white paint (paint as per site requirement) duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape complete all as specified and directed. |
| 107 | Material and labour for cleaning complete solar panel set (36 panel) using soft brush and water solution without scratching the panel complete all as specified and directed. |
| 108 | Supply and fixing in repair DC distribution box for solar panel capacity upto 5kw complete all as specified and directed. |
| 109 | Supply and fixing in repair AC distribution box for solar panel capacity upto 5kw complete all as specified and directed. Please Enable Macros to View BoQ information |
| 110 | Supply and fixing in repair AC distribution box for solar panel capacity upto 5kw complete all as specified and directed. Please Enable Macros to View BoQ information |