Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #56124343

Tender For Special Repair To Toilets/ Bathrooms In Bldg No P-533 (Rezang La), Bldg No P-318 (Mechanical Laundry), Bldg No. 221A & 585 (Ata) And Bldg No E1-E3 / B-D (Near Old Lh) At Ota Chennai Under Ge Stm

Issued by Statutory Bodies & Commissions/Committees · Chennai, Tamil Nadu
Tender Value
89.83 Lakhs
Estimated cost
Bid Submission
21 Jul 2026
13 days left
EMD
1.59 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair To Toilets/ Bathrooms In Bldg No P-533 (Rezang La), Bldg No P-318 (Mechanical Laundry), Bldg No. 221A & 585 (Ata) And Bldg No E1-E3 / B-D (Near Old Lh) At Ota Chennai Under Ge Stm

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 07-Jul-2026 OTHER CORRIGENDUM Other 21-Jul-2026

BOQ

Name of Work:- SPECIAL REPAIR TO TOILETS/ BATHROOMS IN BLDG NO P-533 (REZANG LA), BLDG NO P-318 (MECHANICAL LAUNDRY), BLDG NO. 221A & 585 (ATA) AND BLDG NO E1-E3 / B-D (NEAR OLD LH) AT OTA CHENNAI UNDER GE STM
Sl. No. Item Description
1BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER,CHENNAI Name of Work: SPECIAL REPAIR TO TOILETS/ BATHROOMS IN BLDG NO P-533 (REZANG LA), BLDG NO P-318 (MECHANICAL LAUNDRY), BLDG NO. 221A & 585 (ATA) AND BLDG NO E1-E3 / B-D (NEAR OLD LH) AT OTA CHENNAI UNDER GE STM Contract No: CWE/STM/ OF 2026-27 Name of the Bidder/ Bidding Firm / Company : SCHEDULE 'A'(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of items Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT With Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2B/R PORTION:
3Demolition of cement concrete (unreinforced) of any description in ground floors and pavings not exceeding 15cm thickness below or above ground level complete and disposed off from site all as specified.
4Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
5Dismatling of floor, hearth or wall tiling including cement mortar bedding but not backing and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
6Taking down chowkats or frames with shutters (without taking off shutters from frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each including making good the disturbed surfaces of walls, floor etc., complete all as specified and directed.
7Taking down chowkats or frames with shutters (without taking off shutters from frames) not exceeding 1.5 Sqm, each including making good the disturbed surfaces of walls, floor etc., complete all as specified and directed.
8S&F Solid PVC door frame of size 50mmX47mm made out of 5mm thick plain colour PVC sheet reinforced with M.S Square tube, suppling & fixing in opening as per spcification and drawing complete all as specified. Note:-(a) Existing wall edges to be finished properly in cement plaster 1:4 including providing and fixing 6 Nos of wooden plugs of size not exceeding 17Sqcm average sectional areas and 100mm long to fix the door frame (b) Frame shall be fixed to the wall by using 6 Nos of 100mm long MS screw, 3 each on either side on 6 Nos of wooden plug. (c) PCC strip of suitable size shall be fixed at bottom of each door for smooth opening.
9S&F Factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail and panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, jointed together with solvent cement, supplying and fixing in frame at site as per specification and drawing complete all as specified and directed.
10S&F stainless steel butt hinge of size 100 mm, medium weight, cold rolled fixed with stainless screw with frame complete all as specified
11S&F alumininum anodised barrel tower bolts of extruded section of size 200mm complete all as specified
12S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
13S&F Extruded aluminium alloy handles, fabricated type, anodised of size 150 mm long complete all as specified
14M&L for glazed coloured ceramic joint free tiles of size 350mmx250mmx7mm thick or 450mmx350mmx7mm thick on vertical surfaces such as skirting, dados and risers to step etc., set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tile, over and including cement screed of 10mm thick backing coat in cement mortar 1:3 complete all as specified and as directed.
15M&L for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate, 25 mm thick as in bedding layer to tiling complete all as specified.
16M&L for non -skid coloured ceramic joint free tiles 7 mm to 8 mm thick (Square /rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tile, over and including 15mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified.
17Demolition of stone slabs and tiles of any description or thickness in floors, aprons any thickness, laid bedded and pointed in any mortar of any description complete all as specified and directed.
18M&L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screed in CM 1:4 complete all as specified and directed .
19M&L for rounding to edges of granite /stone slabs edge as in steps, cooking platform, and other similar situations complete all as specified and directed.
20S&F Anodised aluminium (Jindal section no 14069, weight 1.093Kg/m) frame for doors, windows, ventilators, etc. with one or more rebates including joining cleat for fixing etc. complete all as specified.
21S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.
22S&F figured glass, pin head type 4mm thick, and glazing with oil putty in square, exceeding 0.5Sqm in each pane and fixed to aluminum frames using rubber packing including hacking out old broken glass etc complete all as specified
23S&F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinges type B-21 100mm long (2 nos.) suitable handle (1 no.) complete all as specified and directed.
24S&F 4.0mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane and fixed to aluminum frames using rubber packing complete all as specified.
25S&F Aluminium anodised tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified.
26S&F in repair vitreous china cascade type wash down water closet coloured including \\"P\\" or \\"S\\" trap with ultra solid seat cover, fixing bolts and flushing cistern complete all as specified and as directed by Engineer-in-charge. Make: Parryware, Shera or othe equivalent make approved by GE
27S&F in repair vitreous china wash down water closet (pedestal pattern), white (excluding flushing cistern and flush pipe) including pedestal pan and trap, connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage pipe, seat cover etc complete all as specified and directed Make: Hindware/ Parryware or othe equivalent make approved by GE
28S&F in repair vitreous china squatting pan, ‘Orrisa pattern’ of size 580 mm x 440 mm, snow white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, integral foot rest with and including provision of lime / plain cement concrete1:2:4 type B1 using 20 mm graded crushed stone aggregate as directed including making connections to trap and to flush pipe, etc and making good to floors complete all as specified.
29S&F vitreous china toilet paper holder with flat recessed type stainless steel with chromium plated (CP) brass screws complete all as specified and directed
30S&F in repair chromium plated health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified. Make: Hindware/ Parryware or othe equivalent make approved by GE Parryware or equivalent
31S&F in repairs PVC, syphonic action type, flushing cistern, low level, white, of 10 litres capacity, with inlet ball valve, float, handle and flush pipe including necessary brackets and 32 mm dia flushpipe of suitable length complete all as specified.
32S&F in repair Vitreous China oval shaped wash basin counter top type, white, of size 550mm x 400mm embedded on marble platforms excluding taps waste, chain and plug and porcelain stopper but including brackets cutting for and pinning in ends of brackets or erecting stand brackets complete all as specified and diected
33S&F chromium plated soap dish of approximate size 160x160x90mm
34S&F in repairs vitreous china urinal, half stall type coloured complete fixed with suitable fixing arrangements as per Manufactuer's instruction to wall with and including CP urinal spreader, CP domed waste coupling and waste pipe complete all as specified and directed.
35M&L for Granite 20mm thick (of any type) work (table rubbed and polished) as in urinal partition, including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
36S&F in repair PVC (SWR) floor trap suitable for 75mm dia pipe with grating including jointing to waste pipe with solvent cement complete all as specified and directed.
37S&F in repair PVC (SWR) multi floor trap with grating including jointing to waste pipe of 75mm dia with solvent cement complete all as specified and directed.
38S&F PVC connection 15 mm size with PTMT nuts of length 450mm
39S&F in repair fancy type CP pillar tap with capstan heads, spindles and washer plates cofirm to IS 1795 having mark 'Cold' or 'Hot' and weight not less than 0.65 Kg complete all as specified and directed.
40S&F in repairs Bib taps 15mm bore cast copper alloy with crutch or butterfly handle chromium plated screwed down for iron pipe or fo brass ferrule fixed.
41S&F in repairs bevelled edge mirror of size 450mm x 600 mm, selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with CP brass screws and cup washers fixing complete all as specified.
42S&F in repairs bevelled edge mirror of size 1200mm x 600 mm, selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with CP brass screws and cup washers fixing complete all as specified.
43S&F in repair stop valves / Angle cock 15 mm bore chromium plated with long shank and cup (concealed type) high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as directed.
44Demolition and breaking up drain pipes of any description of internal dia 100mm set in cement mortar complete all as directed.
45S&F PVC (SWR) pipes of 110mm bore, single socketed, in any length with rubber ring joints or solvent cement, laid in floor complete all as specified
46S&F PVC (SWR) pipes of 75mm bore, single socketed, in any length with rubber ring joints or solvent cement, laid in floor complete all as specified
47S&F PVC (SWR) pipes of 110mm bore, single socketed, in any length with rubber ring joints or solvent cement, fixed to wall with suitable clamps complete all as specified.
48S&F PVC (SWR) pipes of 75mm bore, single socketed, in any length with rubber ring joints or solvent cement, fixed to wall with suitable clamps complete all as specified.
49S&F PVC (SWR) bend 110 mm bore
50S&F PVC (SWR) bend 75mm bore
51S&F PVC (SWR) vent cowl 110 mm
52S&F PVC (SWR) vent cowl 75 mm
53S&F PVC (SWR) junction single, (Single T) equal or unequal suitable for 110mm bore pipe with access door complete all as specified.
54S&F PVC (SWR) junction single, (Single T) equal or unequal suitable for 75mm bore pipe with access door complete all as specified.
55Taking up or down steel / iron tube of 50 mm bore and connections including cleaning for refixing or removal to store complete all as specified.
56S&F CPVC pipes 50mm dia SDR 11 & Plain CPVC SDR 11 fittings laid on walls / floors etc., with suitable clamps complete all as specified.
57M&L for cutting chases not exceeding 20 cm , pinning in and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good complete all as specified.
58Taking up or down steel / iron tube of 32mm bore and connections including cleaning for refixing or removal to store complete all as specified.
59S&F CPVC pipes 32mm dia SDR 11 & Plain CPVC SDR 11 fittings laid on walls / floors etc., with suitable clamps complete all as specified.
60Taking up or down steel / iron tube of 20mm bore and connections including cleaning for refixing or removal to store complete all as specified.
61S&F CPVC pipes 20mm dia SDR 11 & Plain CPVC SDR 11 fittings laid on walls / floors etc., with suitable clamps complete all as specified.
62Taking up or down steel / iron tube of 25mm bore and connections including cleaning for refixing or removal to store complete all as specified.
63S&F CPVC pipes 25mm dia SDR 11 & Plain CPVC SDR 11 fittings laid on walls / floors etc., with suitable clamps complete all as specified.
64S&F stack clamp suitable for 75mm bore pipe made out of mild steel flat iron of size 50mm x 5mm thick and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof including necessary painting the steel surface complete all as specified.
65S&F stack clamp suitable for 100mm bore pipe made out of mild steel flat iron of size 50mm x 5mm thick and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof including necessary painting the steel surface complete all as specified.
66S&F brass elbow of 32mm suitable for CPVC pipe complete all as specified
67S&F brass elbow of 25mm suitable for CPVC pipe complete all as specified
68S&F brass Tee of 32mm for CPVC pipe complete all as specified
69S&F brass Tee of 25mm for CPVC pipe complete all as specified
70S&F Special fittings male brass threaded adaptor (MTA/MBTA) to CPVC Pipes SDR 11, 32mm dia complete all as specified
71S&F Special fittings female brass threaded adaptor (FTA/FBTA) to CPVC Pipes SDR 11, 25mm dia complete all as specified
72S&F CPVC 32 mm dia brass union
73S&F CPVC 25 mm dia brass union
74S&F CPVC 20 mm dia brass union
75Dismantling water tanks and removing to store exceeding 500 litre but not exceeding 1000 litre capacity and removing to store complete all as specified and directed.
76S&F Rotational moulded polyethylene water storage tanks 1000 litres capacity, three layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I and directed.
77S&F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe of 25mm dia and fixed (Minimum weight -455gms) complete all as specified and directed.
78S&F Gun-metal, globe or gate valves with iron wheel head screwed both ends for iron pipe of 50mm dia complete all as specified and directed.
79S&F Gun-metal, globe or gate valves with iron wheel head screwed both ends for iron pipe of 25mm dia complete all as specified and directed.
80Taking down cement plaster on brick or stone walls and floor, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified
81M&L for rendering 10mm thick in cement mortar 1: 6 as under layer and 5mm thick in cement mortar 1:4 mixed with water proofing compound as finishing layer to external wall surfaces, finished even and smooth without using extra cement on external wall surfaces. complete all as specified
82M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement on internal wall surfaces complete all as specified.
83Supply only integral water proofing compound.
84M&L for complete removal of existing treatment on walls and applying two coats of oil bound distemper over a coat of primer over a coat of 3mm thick wall care putty to internal wall surfaces complete all as specified and directed.
85M&L for preparation of old decorated ceiling surfaces including necessary scaffolding and applying one coat of white wash including and filling the cracks / depressions by using chalk whitening wherever required complete all as specified.
86M&L for preparation of new plastered wall surfaces and finishing with acrylic smooth exterior paint of required shade as appoved (Two or more coats) applied @ 1.67 litre /10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and as directed.
87M&L for plain cement concrete 1:5:10 type E2 using 40mm graded stone aggregate as in filling and mass concrete complete all as specified and as directed.
88M&L for plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in lintels and lintel band complete all as specified and directed.
89M&L for old size brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as directed
90M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified
91M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers & binders, cut to length, bent to shape required, binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified
92Demolition of brick tiles or terracing tiles single layer including removal of roof treatmemt of any description and removal of all the debris from site and rubbish off the premises complete all as directed
93M&L for Rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement on roof of G+1 building complete all as directed
94M&L for APP Modified prefabricated five layer water proofing membrane, not less than 3 mm thick and weighing not less than 3.00 kg/Sqm reinforced with non woven polyester matt black finished over compatible bituminious primer confirming to IS-3384 @ 0.3 Litres per Sqm, and a bonding bitumen of VG-10 at 1.20 kg/Sqm torching the membrane on whole surface uniformly while unrolling the membrane by LPG and sealed with trowel after necessary preparation of surface complete all as per Manufactures instructions and finally finished with a coat of bit mastic aluminium paint @ 0.10 litre/Sqm over a coat of blown bitumen 85/25 grade @ 1.20Kg/Sqm over the membrane. The Over lap joint shall be provided of 75mm in longitudinal direction and 100mm in transverse direction respectively. All the angles, abutments and the drainage outlets shall be sealed with extra care to ensure full bondage including preparatory work and removing existing membrane treatment complete all as specified and directed.Manufactures: IWL India Ltd/SAPL (ARGO-P) Hydrotech Ltd (Hydroflame)/STPNote: (i)The work shall be carried out by authorized applicators of Manufacturers.(ii) The work will be carried out on roof slab of G+1 building
95M&L for Hydraulically pressed burnt clay tile plain of size 200 mm x 200 mm x19/20mm machine made laid over and including cement mortar screed 15mm thick in CM 1:6 mixed with and including water proofing compound and jointed pointed in CM 1:3 mixed with 5% crude oil by weight of cement complete all as directed
96M&L for plain cement concrete 1:5:10 type E2 using 40mm graded stone aggregate as in sunken floor of toilets at first floor and second floor complete all as specified and directed.
97M&L for Rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces , finished even and smooth without using extra cement on sunken surface in toilets at first floor and second floor complete all as specified and directed.
98M&L for APP Modified prefabricated five layer water proofing membrane, not less than 3 mm thick and weighing not less than 3.00 kg/sqm reinforced with non woven polyester matt black finished over compatible bituminious primer confirming to IS-3384@ 0.30 litres per Sqm, and a bonding bitumen of VG-10 at 1.20 kg/Sqm torching the membrane on whole surface uniformly while unrolling the membrane by LPG and sealed with trowel after necessary preparation of surface complete all as per Manufactures instructions and finally finished with a coat of bit mastic aluminium paint @ 0.10 litre/Sqm over a coat of blown bitumen 85/25 grade @ 1.20Kg/Sqm over the membrane. The over lap joint shall be provided of 75mm in longitudinal direction and 100mm in transverse direction respectively. All the angles, abutments and the drainage outlets shall be sealed with extra care to ensure full bondage including preparatory work and removing existing membrane treatment completely. The laying of water proofing treatment shall be as per the Guide lines given in SSR/Zonal specification (latest) and complete all as specified.Manufactures: IWL India Ltd/SAPL (ARGO-P) Hydrotech Ltd (Hydroflame)/STPNote:(i) The water proofing treatment at sunken floor be carried out at toilets of FF/SF(ii) The work shall be carried out by authorized applicators of Manufacturers.
99M&L for removing the existing roof treatment of any description completely and remove all the debris from site and rubbish off the premises, clean the surface free from dust, dirt etc. complete all as specified and as directed.
100M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified.
101M&L for Rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement on loft slab of water tank located above lintel level at G+2 buildings complete all as specified
102M&L for APP Modified prefabricated five layer water proofing membrane, not less than 3 mm thick and weighing not less than 3.00 kg/Sqm reinforced with non woven polyester matt black finished over compatible bituminious primer confirming to IS-3384@ 0.30 lit/sqm and a bonding bitumen of VG-10 at 1.20 kg/Sqm torching the membrane on whole surface uniformly while unrolling the membrane by LPG and sealed with trowel after necessary preparation of surface complete all as per Manufactures instructions and finally finished with a coat of bit mastic aluminium paint @ 0.10 litre/Sqm over a coat of blown bitumen 85/25 grade @ 1.20Kg/Sqm over the membrane. The Over lap joint shall be provided of 75mm in longitudinal direction and 100mm in transverse direction respectively. All the angles, abutments and the drainage outlets shall be sealed with extra care to ensure full bondage including preparatory work and removing existing membrane treatment completely.. The laying of water proofing treatment shall be as per the Guide lines given in SSR/Zonal specification (latest) complete all as specified and directed Manufactures: IWL India Ltd/SAPL (ARGO-P) Hydrotech Ltd (Hydroflame)/STPNote :(i) The water proofing treatment to loft slab of water tank located above lintel level at G+2 buildingss(ii) The work shall be carried out by authorized applicators of Manufacturers
103M&L for strengthening the reinforcement exposed RCC soffit surfaces with providing and applying Renderoc SP40 mixed with water in ratio 0.16 a high strength shrinkage controlled cementitious repair mortar average thickness of 50mm incuding provision of Galvonic anode with additional reinforcement and shear connectors drilling 12mm dia holes upto a depth of 75mm maximum and fixing 8mm dia L shaped anchor rods at every 300mm c/c, fill the drilled holes with Lok fix E77 over anti corrosive coating with Nitozinc primer of Fosroc including necessary chipping the spalled old concrete in soffit of the slab all as per Manufactueres instruction including provision of necessar scaffolding as required complete all as specified and as directed.
104M&L for plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate,75mm thick as in plinth protection and paving finished even and smooth without using extra cement complete all as specified.
105Dismantling asbestos cement corrugated, semi corrugated sheets as in roof coverings complete all as specified.
106Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified.
107S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of required colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as per Manufacturer's instruction and as specified
108S&F Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections, Fe 410W (Grade-E-250) Quality A complete all as specified.
109S&F Mild steel screw bolt dia of neck 11 to 15mm (machine made) with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 5 cm but not exceeding 10 cm complete all as specified.
110M&L for preparation of new steel surfaces of any description, over 10 cm in width not otherwise described, priming with red oxide zinc chrome and two coats of synthetic enamel paint complete all as specified.
111S&F Stainless steel sinks made of 1mm thick sheet ,overall size 1900mm x 500mm, bowl size 1815mm x 415mm x 500mm suitable for operation theatre / laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe complete all as specified and directed.
112M&L for water proofing treatment with APP modified prefabricated five layer water proofing membrane, not less than 3mm thick and weighing not less than 3 Kg/Sqm reinforced with non woven polyester matt black finished over compatiable bituminious primer confirming to IS-3384 & 0.30 lit/sqm, touching the membrane on whole surface uniformly while unrolling the membrane by LPG and sealed with trowel after necessary preparation of surface complete all as per manufactures instructions . The over lap joint shall be provided of 75mm in longitudinal direction and 100mm in tranverse direction respectively. All the angles, abutments and the drainage outlets shall be sealed with extra care to ensure full bondage complete all as specified and directed . Manufactures : IWL India Ltd/SAPL (ARGO-P) Hydrotech Ltd (Hydroflame)/STP. Note: (i)The work shall be carried out be authorised applicators of Manufactures (ii) The work will be carried out on roof slab of G+1 buildings (iii) Applying two coats of aluminium paint @ 100ml/sqm
113M&L for preparing old ceiling surfaces and applying two coats of Asian paints damp proof or oher equivalent over a coat of primer with water in ratio 1:3 including filling cracks with smart care crack seal or other equivalent complete all as specified.
114M&L for preparing old wall surfaces and applying two coats of Asian paints damp proof or other equivalent over a coat of primer with water in ratio 1:3 including filling cracks with smart care crack seal or equivalent complete all as specified.
115E/M portion :
116Taking down carefully copper point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc can be measured separately) removing the material from wall/ceiling etc, making good the disturbed surfaces and taken as credit complete all as specified and directed.
117M&L for Point wiring complete with 1.5 sqmm FRLS single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor drawn through and including non-metallic rigid PVC conduit PVC conduit fittings and conduit accessories concealed in walls, roofs and floors etc., including Modular flush boxes and Modular cover plates for switches concealed in walls, roof and socket / electronics fan regulator / telephone socket, including provision of 1.5 sqmm PVC insulated unsheathed cable with multi stranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for one light/fan point controlled by one way switch complete including cutting chases, pinning in, not exceeding 10 Cm girth and making good to facing where required and pointing in cement mortar 1:3 for concealed conduit wiring complete all as specified and as directed.
118One light point controlled by one switch.
119One 3 pin 5 amps switch socket on independent board.
120One 3 pin 5 amps switch socket on same board along with other switches.
121One exhaust point controlled by one switch
122All as per item No.114 above but with 4 sqmm FRLSH copper conductor cable with 2.5 sqmm PVC copper conductor cable as earth continuity conductor for one socket outlet 15/16 Amps controlled by one switch 15/16 Amps on independent board all as specified and as directed.
123M&L for sub main wiring with PVC insulated, 1100 volts grade single core FRLSH multistranded copper conductor cable conforming to IS specifications, 2 runs of 6 sqmm including one run of 6 sqmm single core multistranded copper conductor PVC insulated cables as earth continuity conductor with colour code drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories or casing capping including accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly including taking down old sub min wiring all as specified and directed.
124S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down old light fittings of any type and watts complete all as directed.
125S&F LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size including taking down old light fittings of any type and watts complete all as directed.
126S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including taking down old light fittings of any type and watts complete all as directed.
127S&F MCB distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 04 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection including taking down old DB of any description complete all as directed.
128S&F MCB Distribution board, 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 8 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection including taking down old DB complete all as directed.
129S&F MCB SPN 230 volts, 40 amps 'C' Curve 10 kA capacity including taking down old MCB complete all as directed.
130S&F MCB SP 230 volts,40 amps 'C' Curve 10 kA Capacity including taking down old MCB complete all as directed.
131S&F ceiling rose surface bakelite 65mm x 50 mm two to three terminals
132S&F Modular switch 1 way 6A, 1 module, 240 Volts
133S&F Modular switch 1 way 16A, 1 module, 240 Volts
134S&F Modular Socket, 6A - 2/3 pin combined 2 module
135S&F Modular socket 6 A/ 16 A - 2/3 pin combined 2 module
136S&F in replacement wall mounting Hand Dryer commercially designed Heavy duty premium finish with maximun air flow 123CFPM complete all as specified and as directed.
137S&F in replacement wall fan of size 450 mm sweep, alumimum body heavy duty all as specified and as directed. Note: Old wall fan shall be deposited to MES store
138Taking down Ceiling / Exhaust fan, sealing cable end, dismantling blades and removing fan and blades to and depositing it to MES store yard without any damage including the charges of transporation of fan and labour cost etc.complete all as specified. Note: Old exhaust fan shall be deposited to MES store
139S&F in replacement of ventilating fan of size 250 mm sweep white in colour, plastic body all as specified and as directed. Note: Old exhaust fan shall be deposited to MES store
140S&F in replacement Exhaust fan, steel body AC single Phase 230V of size 300mm sweep with, blades, and frame and louversi ncluduing all accessories as per site requirment complete all as specified and as directed. Note: Old exhaust fan shall be deposited to MES store
141S&F in replacement exhaust fan, steel body AC single Phase 230V of size 450mm sweep heavy duty, blades, and frame and louvers complete all as specified and as directed.Note: Old exhaust fan shall be deposited to MES store
142M&L for Earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, washers and check nuts made out of galvanised iron, protected by GI pipe light grade 15 mm bore dia and connected to main control board all as shown in Electrical plate No 5 of MES SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoad dust, PCC 1:2:4 type B1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100 mm centre to centre both ways and MS 6 mm dia hook complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56124343
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 89.83 Lakhs
LAST DATE 21-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To Toilets/ Bathrooms In Bldg No P-533 (Rezang La), Bldg No P-318 (Mechanical Laundry), Bldg No. 221A & 585 (Ata) And Bldg No E1-E3 / B-D (Near Old Lh) At Ota Chennai Under Ge Stm
Basic Detail
Tender No 86629/E8
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 07 Jul 2026
Submission Date 21 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 89.83 Lakhs
Tender Fee 1000
EMD 1.59 Lakhs
Exemption Available
Document List
1b5f82d1-7a33-448f-ac08-247cd5734f4b.html
86629TENDER.pdf
BOQ_866849.xls
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 21, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 13 days
Jul 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

1b5f82d1-7a33-448f-ac08-247cd5734f4b.html

pdf

86629TENDER.pdf

xls

BOQ_866849.xls

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders