Defence Statutory Bodies & Commissions/Committees Closing in 3 days TDR #56123309

Tender For Providing / Addition Alteration Of Certain Parking Sheds At Certain Locations At 8Fbsu

Issued by Statutory Bodies & Commissions/Committees · udhampur, Jammu and Kashmir
Tender Value
43.68 Lakhs
Estimated cost
Bid Submission
20 Jul 2026
3 days left
EMD
87500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
udhampur → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Providing / Addition Alteration Of Certain Parking Sheds At Certain Locations At 8Fbsu

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 13-Jul-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-Jul-2026

BOQ

Name of Work:- PROVN/ADDN/ ALTN OF CERTAIN PARKING SHEDS AT CERTAIN LOCATIONS AT 8FBSU
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE (AF), 8FBSU,AF Name of Work: PROVN/ADDN/ ALTN OF CERTAIN PARKING SHEDS AT CERTAIN LOCATIONS AT 8FBSU Contract No: GE (AF) AWA-22/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. DESCRIPTION OF ITEMS Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2B/R PORTION
3Dismentalling of plain or corrugated steel sheeting of any gauge, thickness etc in roof coverings/cladding/eave etc complete all as specified.
4S&F galvanised corrugated mild steel sheeting, with two corrugation side lap fixed with 'L' type or 'J' type or cranked hooked bolts with washers in roof, 0.63 mm thick, grade-O quality, with 120 grms/sqm zinc coating and grade 'B' Class 8 complete all as specified and directed by Engineer-in-Charge.
5S&F Galvanised plain mild steel sheeting 0.63 mm thickness fixed with 'L' type or 'J' or cranked hook boltes with washers, in roofs as in ridge etc all as specified and directed.
6S&F 1.00 mm thick plain, galvanised, mild steel sheeting, in eaves board & straight flashings (length & girth as fixed) with welded and sholdered joint to be provided all as specified and directed by Engr-in-Charge.
7Preparation of new surfaces of steel or iron work or CGI/ PGI sheeting in walls or roofing, over 10cm width or girth, not otherwise described and applying two coat of synthetic enamel paint in camouflaging (Disruptive) pattern in three colours (Green, grey and brown) over a coat of acrylic primer complete all as specified and directed.
8Demolition of cement concrete (reinforced) of any description and in any position complete all as specified and directed by Engr-in-Charge.
9M&L for reinforced cement concrete design mix M-30 (using 20 mm graded crushed stone aggregates) in columns, pillars, posts & struts complete. (Note : Reinforcement shall be measured and paid separately).
10M&L for reinforced cement concrete (design mix) M-30 using 20mm graded crushed stone aggregrate in beams, cantilevers, bressummers, lintels over 1.5m span; all as specified and directed.Note : Reinforcement shall be measured and paid seperately.
11S&F for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, all as specified and directed.
12S&F for TMT bars 6 mm to 8 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, all as specified and directed.
13M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finish surface of concrete flat, all as specified and directed.
14M&L for formwork to sides and soffits of floor or roof beams, beam hunchings, girders, bressummers, lintels, cantilevers, etc. also splays between floors and beams, etc. rough finish surface of concrete flat, all as specified and directed.
15Demolition of Brick work with sub class 'B' bricks using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), with and complete all as specified.
16M&L Brick work with sub class B bricks ,straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and directed.
17Taking down Cement Plaster, any description on Brick Walls or on Concrete Surfaces including raking out Joints, hacking for Key, scrubbing down with water, etc, and removing same from the site(s), complete all as specified and as directed.
18M&L for rendering 10 mm thick on fair faces of concrete/brick interior surfaces in cement mortar 1:6 as per manufacturer's instruction, finished fair and even without using extra cement, complete all as specified and directed.
19M & L Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 on wall surfaces, finishing the surface even and smooth without using extra cement, complete all as specified. Note:- Integral water proofing compound shall be measured and paid for separately.
20Supply only Liquid water proofing compound ISI marked (used 200 ml per bag of cement), complete all as specified and directed.
21M&L for applying 3mm thick wall care putty in two layer on prepared suface, complete all as specified and directed.
22Preparation of newly or plastered or un-plastered surfaces of walls and applying two coats of Acrylic washable distemper over a coat of primer, complete all as specified and directed.
23Preparing new plastered or un-plastered surfaces of walls and applying two coats Acrylic exterier emulsion paint in camouflaging (Disruptive) pattern (Green, Grey & Brown colour) over a coat of acrylic primer, complete all as specified and directed.
24Preparing old decorated plastered or un-plastered surfaces of walls by scraping the surfaces, brooming down or steel wire brushing down smoke soot, mould, moss and efflorescence salts and trading oil and greasy spots etc and applying one coat of exterior acrylic emulsion paint in camouflaging (Disruptive) pattern in three colours (Green, grey and brown), complete all as specified and directed.
25M&L for complete removal of existing treatment of old decorated plastered or un-plastered surfaces of wall and applying two coats of Acrylic washable distemper over a coat of primer, complete all as specified and directed.
26Dismantling cast iron work of any description including unbolting, dismantling framed work into two or more portable parts and marking members for re-erection, complete all as specified and directed by the Engr-in-Charge.
27Fabrication and erection fixing of old roof trusses (framed), trussed, posts, struts, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, base plate and gusset plates etc confirming to Fe 410-W (Gde-E- 250) quality-A, complete all as specified and directed.
28M&L for Preparation of old painted steel or iron surfaces of any description not otherwise described over 10cm width or girth, and applying one coat of synthetic enamel paint complete all as specified and directed.
29Taking down (Steel/ Wooden) chowkhats of frames of any description n.exc 1.50 sqm with shutters (without taking off shutters from the frames) and making good disturbed portion, complete all as specified and directed.
30S&F of 2nd class hard wood Plain solid straight chowkhats of wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete including tarring back of surface in contact with walls all as specified & directed.
31S&F for 4 mm thick sheet glass ordinary quality and glazing with spring clips in metal surrounds and oil putty in squares not exceeding 0.50 sqm in each pane, complete all as specified and directed by Engineer-in-Charge .
32Demolition of cement concrete to ground floor (unreinforced) and paving n.exc 15cm thickness (below or above ground level) and removing rubbish of out side MOD land, complete all as specified and directed.
33M & L 75 mm thick PCC (1:3:6) type C-2 using 40mm graded aggregate as in plinth protection even and smooth without using extra cement, complete all as specified and directed.
34M&L 100 mm thick PCC 1:1.5:3 (M-20 nominal mix) type A-2 using 40 mm graded aggregate as in hard standing including cuttting, filling complete all as specified and directred by Engr-in-Charge.
35S & F in repairs wire netting of galvanised steel wire 0.71 dia and above size of mesh 25 mm fixed with tinned tacks of wire staples, all as specifed and directed by Engineer-in-Charge.
36Taking down shutters of any description area exc 2.00 Sqm each, all as specified & directed.
37S&F Steel rolling shutters tickness of lath 1.25mm thick with out ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or gear operated type with bevel gear box & crank handle, complete all as specified and directed by Engr-In-Chagre.
38Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in any type of soil.
39M&L 100 mm thick cement concrete 1:2:4 Type B-2 (using 40 mm graded crushed stone agreegate) as in flooring including finshing even and smooth without using extra cement, complete all as specified and directed.
40M&L for sand filling under floor or in foundation or below interlocking tile of 25 mm thick layer including watering and consolidation etc, complete all as specfied and as directed.
41S&F for 60 mm thick machine pressed precast concrete interlocking paver block with grey cement and No pigment, shape and size confirming to IS 15658-2006, M-35 Grade over, complete all as specified and directed.
42Excavating in post holes (or similar holes) in any type of soil each not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 Cm ,watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete.
43M&L cement concrete in foundation filling and mass concrete type D2 1:4:8 (using 40 mm graded Agg) in post holes all as specified.
44S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles, as necessary gusset plates, riveting, etc, n.exc 10 Kg each bracket confirming to Fe-290 Gde-E-165, complete all as specified and directed.
45E/M PORTION
46M&L for point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 Volts grade, multistranded copper conductor cable 1.5 Sqmm in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated, unsheathed, FRLS type, 1100 Volts grade,1.5 Sqmm copper conductor cable unsheathed as earth continuity cable including suitable modular cover plate for mounting of switches, socket, fan regulators, connected to common earth dolly, complete all as specified for the following:- (a) One light /fan/ point controlled by one nos, one way 5/6 Amps switch.
47(b) All as per srl item No 45.00 here-in-before but using one 3/5 pin socket outlet, 5/6 Amp on the same board controlled by one nos, one way switch.
48(d) All as per srl item No 45.00 here-in-before but using one 3/5 pin socket outlet, 5/6 Amp, independent controlled by one nos, one way switch.
49All as per srl item No 45.00 here-in-before but using cable of size 2.5 Sqmm (for phase & neutral) and 1.5 Sqmm as continuous earth cable for 15/16 Amps socket outlet, independent controlled by one nos, one way switch, complete all as specified.
50S&F in replacement of modular piano type switch one way one module, SP, flush type, 5/6 Amps, 230 Volts AC, 50 Hz, complete all as specified.
51S&F in replacement of modular piano type socket outlet flush type 2 module, 5 pin, 5/6 Amps, 230 Volts AC, 50 Hz, multipurpose type, complete all as specified.
52S&F in replacement of modular piano type switch one way one module, SP, flush type 15 Amps, 230 Volts AC, 50 Hz, complete all as specified.
53S&F in replacement of modular piano type socket outlet flush type 2 module, 5 pin, 5/15 Amps, 230 Volts AC, 50 Hz, multipurpose type, complete all as specified.
54S&F in replacement of ceiling rose 3 terminals, PVC/polycarbonate/bakelite, isolated body 230 Volts AC, 50 Hz, complete all as specified.
55Supply and fix in replacement submain wiring with 2x1.5 Sqmm PVC insulated unsheathed multi-stranded single core FRLS/FRLSH copper conductor cables (1100 Volts grade), drawn in ISI marked casing capping with accessories, along with 1x1.5 Sqmm PVC insulated unsheathed copper conductor for continuous earth wire, including making good the disturbed surfaces, complete as specified.
56Supply and fix in replacement submain wiring with 2x4 Sqmm PVC insulated unsheathed multi-stranded single core FRLS/FRLSH copper conductor cables (1100 Volts grade), drawn in ISI marked casing capping with accessories, along with 1x4 Sqmm PVC insulated unsheathed copper conductor for continuous earth wire, including making good the disturbed surfaces, complete as specified. (For ACs & Geysers)
57S&F in replacement LED tube light fitting 1x20/22 Watts, 220 Volts AC, 1200 mm, with aluminium housing & integrated electronic driver complete with driver with polycarbonate diffuser & thd< 10% including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose, complete all as specified.
58S&F in replacement of sheet metal enclosure DB TPN 4 way, double door, 415 Volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB TP/TPN as incomer & MCB SPN as outgoing complete all as specified.
59S&F in replacement of MCBs, TPN, 40-100 Amps, 415 Volts, 10 kA rupturing capacity, C curve type, complete all as specified and directed.
60S&F in replacement of sheet metal enclosure DB SPN 8 way, double door, 230 Volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB DP/SPN as incomer & MCB SP as outgoing, complete all as specified.
61S&F in replacement of MCBs, SP, 6-32 Amps, 230 Volts,10 kA rupturing capacity, C curve type, complete all as specified.
62S&F in replacement of MCBs, SPN, 40-63 Amps, 230 Volts, 10 kA rupturing capacity, C curve type, complete all as specified.
63M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil, complete all as specified.
64Supply , Laying and testing cable XLPE insulated, Screened, PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty ) 1100 Volts grade with standard aluminium conductor of size 25 Sqmm 4 Core.
65Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of new/serviceable cables or for fault finding in existing cable and getting out soil in soft/loose soil complete all as specifed.
66Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 Cm, complete all as specified.
67Removing excavated material not exceeding 50 Mtr and depositing where directed in a level not exceeding 1.5 Mtr above the starting point of any type of soil, complete all as specified
68M&L for sand cushioning to under ground cable provided with a layer of sand 8 Cm depth before laying of cable and 15 Cm depth after laying and stretching the cable all as specified. Note: Punned thickness of sand shall be measured & paid.
69M&L for well burnt sub class 'B' bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick, complete all as specified.
70Taking down the existing aluminium/ copper strip/ GI strip of any size and type from the top of blast pens/ ground/ equipment/ bldg (roof/ down conductor), complete all as specified and directed.
71Dismentling the existing single pointed air termination Al/Coppper rod , GI tubbing and PCC blocks any size and type from the top of blast pens/ ground/ equipment/ bldg (roof/ down conductor), complete all as specified and directed.
72M&L for fixing of air termination, single pointed copper rod 12mm dia and 300 mm long on PCC block, complete all as specified and as directed. (PCC block work included in this item)
73Supplying and laying, fixed to the wall GI tubing medium grade of size 25 mm bore for installation of the air termination rod on the top of it, complete all as specified.
74Test Point terminal block made of gunmetal or phosphorus bronze size 75X75X25mm drilled and screwed including 03 Nos 8 mm dia long hex head screw, complete all as specified and directed by Engineer-in-Charge.
75M&L for plain cement concrete in foundation 1:2:4 type B-2 with 40 mm graded stone aggregate to support the pipe/angle/as required on site including breaking of existing complete all as specified.
76S&F copper strip 20x3.15 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing and nut bolts jointing at all joints complete all as specified.
77M&L for Earthing complete with Copper earth plate 600 x 600 x 3.15 mm thick buried directly in ground (earth pit not less that 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level connected to 20x3 mm Cu strip as earthing lead by means of brazing after tighten by bolts, nuts, check nuts and washers from earth pit to test point with protection GI pipe of size 50mm dia light grade and providing masonry enclosure including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit pit covers of 300 mm x 300 mm made of cast iron including painting as per color coding as per IS, in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil, complete as specifed and directed. Note: (i) Copper strip 7.5 mtr included in the quoted rate from earth pit to test point (ii) Contractor should ensure that result of each earthing is less than 2 Ohm and in case soil is not suitable for the same is to be placed suitable clay soil to bring the desired result. Contractor shall quote rates after site visit accordingly. (iii) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to department. (iv) Work includes brazing work for earth strip. (v) Work includes brazing of Cu strip to copper earth electrode
78Note :- An amount of Rs. 55,888.00 on account of credit schedule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56123309
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.68 Lakhs
LAST DATE 20-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Providing / Addition Alteration Of Certain Parking Sheds At Certain Locations At 8Fbsu
Basic Detail
Tender No GE (AF) AWA-22/2026-27
Bidding Type Tender
Location
City udhampur
State Jammu and Kashmir
Key Dates
Publish Date 13 Jul 2026
Submission Date 20 Jul 2026
Open Date 22 Jul 2026
Finance
Tender Value 43.68 Lakhs
Tender Fee 500
EMD 87500
Exemption Available
Document List
BOQ_866572.xls
Tender22.pdf
Tendernotice_1 (2).pdf
1dc65d9f-010d-46d1-ac7e-1f7214db67e0.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 20, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Jul 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Jul 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_866572.xls

pdf

Tender22.pdf

pdf

Tendernotice_1 (2).pdf

html

1dc65d9f-010d-46d1-ac7e-1f7214db67e0.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders