| 1 | WATER RESOURCES DEPARTMENT, PUNJAB SANGRUR CANAL AND GROUNDWATER DIVISION, SANGRUR Name of the work: Estimate for Linking of Water Course to Village Badra Pond connected to Canal Water by laying Underground Pipeline Name of Firm Sr.No Description Unit Qty Rate (in figures) Amount |
| 2 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. Earth work upto 1.5 m. Depth for All classes of soil except rocky |
| 3 | Lowering, jointing and cutting of UPVC socket end pipes 250 mm dia laying same to correct gradient and alignment and jointing ends and fixing collars with cement mortar 1:2 as per IS 458:2003 in all depths complete in all respect |
| 4 | Providing, lowering in trenches to correct gradient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as per IS code IS 458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc R.C.C. Pipe NP -2 300 mm i/d pipe |
| 5 | Providing & Fixing Kirloskar Monoblock 5 HP Pump |
| 6 | Providing & Fixing G.I. Pipe 100 mm inner dia |
| 7 | Providing & Fixing G.I. Bend 100 mm inner dia |
| 8 | Providing & Fixing Return Valve 100mm |
| 9 | Providing & Fixing Control Panel 20 HP 3 phase |
| 10 | Providing & Fixing Grip for Panels |
| 11 | Providing & Fixing wire 7/16 |
| 12 | Providing stand board |
| 13 | Providing & Fixing HDPE Rubber Pipe |
| 14 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres |
| 15 | Cement Conc mechanically mixed with stone ballast or shingle using concrete mixer volumetric type |
| 16 | Cement conc 1:2:4 manually mixed with stone ballast of shingle |
| 17 | Rainforced cement concrete 1:2:4 hand mixed |
| 18 | First Class burnt brick work laid in csm 1:6 in foundation & plinth |
| 19 | 10 mm thick cement plaster 1:4 on BED |
| 20 | 10 mm thick cement plaster 1:4 on sides |
| 21 | Centering shuttering For slab |
| 22 | Providing orange colour safety footrest of minium 6mm thick plastic encapsulatedas per IS:10910 on 12mm dia steel bar conforming to IS:1786 having minimum cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 38mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 complete as per design |
| 23 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement,centring and shuttering in foundation and plinth |
| 24 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position Commercial with elm or gurjan facing on both \Sides with laminated core and lipped edges:- 35mm thick |
| 25 | Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete Doors and windows frame of size 113mm x 60mm with 35 mm wide single rebate weighing 3.38 kg per meter. |
| 26 | Cold twisted deformed (ribbed/ tor steel) Bars Fe 500 grade as per IS 1786-1985 for R.C.C. works, where not included in the complete rate of R.C.C. including bending, binding, and placing in position complete. |
| 27 | Any other Item |