Housing Urban and Rular Development Government Departments Closing in 0 days TDR #56122230

Tender For Construction Of (G+2) Storied 50 Bedded Critical Care Block At Barasat Government Medical College And Hospital, North 24 Parganas ---- Dismantling And Refixing Fitting-Fixtures Including Rectification & Modification Of Miscellaneous Ancill

Issued by Government Departments · 24 Paraganas North, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Jul 2026
0 days left
EMD
9576
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of (G+2) Storied 50 Bedded Critical Care Block At Barasat Government Medical College And Hospital, North 24 Parganas ---- Dismantling And Refixing Fitting-Fixtures Including Rectification & Modification Of Miscellaneous Ancillary Electrical Work In Respect Of Ongoing Chiller A.C. Ducting Job.

BOQ

Name of Work:- Construction of (G+2) storied 50 Bedded Critical Care Block at Barasat Government Medical College and Hospital, North 24 Parganas ---- Dismantling and refixing fitting-fixtures including rectification & modification of miscellaneous ancillary electrical work in respect of ongoing Chiller A.C. ducting job.
Sl. No. Item Description
1Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Make- Legrand/L&T/ Schneider) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Power Plug for Air-Curtain)
2Supply & Fixing 240 V, 25 A, Modular type AC starter (Make- North West/Crabtree/ Legrand/L&T) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (for Cassette/FCU)
3Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make- North West/ Crabtree / Legrand /L&T), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. (for Cassette/FCU)
4Supplying & Fixing CRC sheet metal (16 SWG) JB-cum-Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite / Perspex coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
5175 mm x 100 mm x 65 mm
6200 mm x 150 mm x 65 mm
7240 mm x 200 mm x 65 mm
8300 mm x 200 mm x 65 mm
9Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws.
10200 mm x 150 mm x 65 mm
11240 mm x 200 mm x 65 mm
12Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- RR Kabel/Polycab/Finolex/Havells) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.
134 x 84/0.3 (6 sqmm) + 2 x 56/0.3 (4 sqmm) ECC (for AC AHU power)
14Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
1520 mm size
1625 mm size
17Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.
1819 mm dia 3 mm thick polythene pipe without earth continuity wire
19Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction).
2019mm dia 3mm thick Polythene Pipe
21Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Make- RR Kabel /Polycab /Finolex / Havells) of the following sizes in the prelaid polythene pipe/PVC rigid conduit as per GS.
223 x 22/0.3 (1.5 sqmm) as ECC
232 x (2.5 sqmm) + 1 x (1.5 sqmm) as ECC
242 x (4 sqmm) + 1 x (2.5 sqmm) as ECC
254 x (10 sqmm) + 2 x (6 sqmm) as ECC (for MRL Lift Controller power)
264 x (16 sqmm) + 2 x (10 sqmm) (for UPS power)
27Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
28a) 1.5 sq mm
29b) 2.5 sq mm
30c) 4 sq mm
31d) 6 sq mm
32e) 10 sq mm
33f) 16 sq mm
34Supply and fixing of Ceiling Rose with base on existing point. (Make- Precision)
35Dismantling of the existing obstructed electrical installtaion incl. electrical wiring, JB cum switch boards, fittings-fixtures, cable tray & other materials by Co's own tools & tackels and shifting & relocate the same at suitable place & mending good the damages as per direction of EIC near about 5 days.
36Supplying and fixing MCB SS enclosure (Make- Legrand/L&T/ABB/Schneider) with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment.
374 Way (for MRL Lift Controller power)
38Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connections as per GS. [Make- Legrand/L&T/Schneider/ABB]
396-32 A FP (for MRL Lift Controller power)
40Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring as per GS.
414 core 16 Sq. mm. (for existing cable)
42Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make) as per GS.
434 core 16 Sq. mm. cable (for existing cable)
44Supply & fixing of 230V, 50Hz, 24 hrs. Digital Time Switch (Make- L&T GIC, Crono 67DDTO) in 4 way SS enclosure (Make- Legrand/L&T/ABB) for controlling of exhaust fan as per direction of EIC.
45Fixing only single/twin florescent/LED light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required.
46Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
47Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
48Fixing only 2ftx2ft recessed mounted LED light fitting on false ceiling complete with all accessories incl. making necessary disconnection and connection as required.
49Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welde, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.
50Lowering and refixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. making necessary disconnection and connection as required.
51Supply & fixing of MS down rod of 14 SWG 20mm dia for ceiling fan from fan clamp to body with necessary arrangement of nuts, bolts, washers etc. incl. drilling hole on downrod & painting the same as required.
52Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire.
53Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter :
5430 cm (12\\")
55Supply & Fixing louver shutter on wall with necy. Bolts & nuts (6mm dia x 62 mm long) For GI
5630 cm Exhaust fan (12\\")
57Supply & DELIVERY OF 230 v, 50 Hz, single phase, 48 watts, 12\\" (300 mm) Sweep, speed 900 rpm (Minimum), A C Exhaust Fan and class of insulation B, 4 nos metal (Aluminium alloy) blades, copper winding, steel/Al body Power Factor not less than 0.9 and minimum air delivery 1145 cmh (minimum) capacitor with safety pin, nut bolts, washers, temperature nse=75 degree C (max), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required.
58Fixing only exhaust fan with all accessories and making necessary alteration of existing hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire incl. making necessary disconnection and connection for exhaust fan as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56122230
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 06-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of (G+2) Storied 50 Bedded Critical Care Block At Barasat Government Medical College And Hospital, North 24 Parganas ---- Dismantling And Refixing Fitting-Fixtures Including Rectification & Modification Of Miscellaneous Ancillary Electrical Work In Respect Of Ongoing Chiller A.C. Ducting Job.
Basic Detail
Tender No 18/T of 26-27 of AE/BESD
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 22 Jun 2026
Submission Date 06 Jul 2026
Open Date 08 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 9576
Exemption Not Available
Document List
2911.pdf
BOQ_5084839.xls
f3f81675-9fcf-42d7-86f3-ec0a3d02bda4.html
Tendernotice_1 (12).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Jul 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
pdf

2911.pdf

xls

BOQ_5084839.xls

html

f3f81675-9fcf-42d7-86f3-ec0a3d02bda4.html

pdf

Tendernotice_1 (12).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender