| 1 | Balance Works 132 KV S/s Harda |
| 2 | 3004746,SOR 2.6,Part-A (Filling around TLM office Harda)Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil |
| 3 | 10 NSOR , 3000108 Compaction of moorum/earth by using SRR/DRR including hire& running expenseof roller, costof water ,T&P,LABOUR ,transportation ,taxes etc, completeas directed by Engineer in charge |
| 4 | 2 NSOR,3000100, Supplying and spreading in EHV Substation yard or road work with hard moorum/hard copra having maximum dry density not less than 2 MT per cum with stacking, boxing,including cost of material .T&P,Royalty, all lead & lift etc. |
| 5 | 4.1.2.3, 3004838, P/L in position cement concrete concrete of specified grade M-7.5 with 40mm metal Nominal Mix-1 cement;4 sand:8 graded stone aggregate. |
| 6 | 4.3.2,3004848 Centering and shuttering including strutting, propping etc. and removal of form work for :..above plinth: Retaining walls, return walls, walls (any thickness) including attached pilasters, uttresses, and string courses fillets etc.\\" |
| 7 | 3004847,4.3.1,Centering and shuttering including strutting, propping etc. and removal of form work for : …….Upto plinth: Foundations, footings, bases for columns, plinth beams, curtain walls, columns below plinth. |
| 8 | 300141,38 NSOR,Providing and laying in position Reinforced Cement Concrete NP 3 class/ prestressed concrete hume pipe for culverts on first class bedding of granular material in single or double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete & masonary works in headwalls, parapets, abutments etc., but including cost of pipes, collars, cement mortar for jointing, placing in position, labour, transportation etc., complete as per direction of Engineer-in-charge.(a) Pipe Diameter 300mm (Base Rate Rs. 1530/- per Rmt) |
| 9 | 3004835,4.1.1.4,Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : ….M-10Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate ) |
| 10 | 3000146,41 NSOR ,Providing & Fixing 100 mm dia AC/PVC pipe with grating for weep holes in Brick masonary/ Plain/Reinforement cement concrete abutments , wing walls, retaining walls etc. extending through the full width of abutments , wing walls, retaining walls etc.with a slope of 1H: 20V including cost of all material, labour, T&P etc. complete as directed by Engineer in charge. |
| 11 | 3000154,49 NSOR ,Labour only for fixing of chain link mesh fencing in position on angle iron with nuts, bolts, washer including grouting of post if required including cost of nuts,bolts, flat washers of size 100 x 30 x 3mm as required but excluding cost of other material as per direction of Engineer-in-Charge. (Note:- 229 SQM old Chain link mesh will be used from dismentalling of chain link mesh from different places will be used . 1688.82 Kg old angle recd. From dismentalling of chain link mesh from different places will be used) |
| 12 | 3006217,13.50,Finishing walls by any mechanical or manual means with water proofing cement paint of required shade: New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 13 | 3006240,13.64,Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 14 | 3000150,45 NSOR ,P&F Barbed wire (9.38 Kg per 100 M min.) to MS Angle iron posts including screwing with GI tying wire staples or steel pins i/c cost of wire, staples pins etc., as per the direction of Engineer-in-charge.(Base Rate Rs. 8/- per Rmt.) |
| 15 | 300602,SOR 12.15,(Construction of Cycle Stand at TLM office Harda) Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 ...... ...... with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 16 | ,SOR 10.14.1,Steel work in built up M.S. tubular section (round, square or rectangular hollow tubes etc.) trusses/frame work etc. including cutting,…..Hot finished welded type tubes |
| 17 | 300103,5 NSOR ,Boring holes with auger for under reamed pile of 200 mm dia of depth 2.0 M including reaming 2.5 times the dia of pile for one bulb at specified depth including cost of all material , T&P, Labour etc. complete as per drawing and as directed by Engineer in charge |
| 18 | 3004884,SOR 5.1.1,Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-20 Grade Concrete |
| 19 | 3004929,SOR 5.16.6,Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps ...................Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”)Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786 |
| 20 | 3004893,SOR 5.9.1,Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level |
| 21 | 3011183,247(a) NSOR ,(PCC Paver Block) Construction of Shoulders with approved material/ selected soil i/c excavation all lifits & leads i/c grading to required slope & camber and compacting using vibratory roller of 80 to 100 kN static werght to meet requirement as per relevant clause of 400 of \\"\\"specifications for road and bridge works\\"\\" (5th revision) published by the Indian Road Congress April 2013, on behalf of the govt. of India, Ministry of Road Transport & Highway (Road Wing) ..A Earthen Shoulders (CBR valur>7) \\" |
| 22 | 3005909,SOR 11.72.1,Providing and laying factory made chamfered edge Cement Concrete paver blocks of required colour strength, thickness pattern, surface texture (smooth/rough) and size/shape, conforming to 15658-2006 IS marked made by table vibratory method using PU mould, laid in required colourand pattern over 50mm thick compacted bed of stone dust, compacting and proper embedding/ laying of inter locking paver blocks into the bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including locking edges in 0.30 mm with courtyards, porch with M 15 cement concrete in footpath, parks, lawns, drive ways or light traffic parking etc. complete as per manufacturer'sspecifications and direction of Engineer-in- Charge. 80 mm thick C.C. paver block of M-35 grade |
| 23 | 3004811,SOR 2.34 ,Excavation in soil using hydraulic excavator and including cutting and loading in tippers, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- section, and transporting to the appropriate ground contour, location and levelling and dressing earth neatly with all lifts and lead upto 1000 metre. |
| 24 | 3004097,244 NSOR ,Granular Sub-base with Well Graded Material (CBR>30 or more) (Table:- 400-1 & Table 400-2)-Construction of granular sub-base by providing well graded material like natural sand crushed gravel or crushed stone having CBR >30, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator or plant mix method at OMC, and compacting with vibratory rollers of 80 to 100 kN static weight to achieve the desired density, complete as per Clause 401 of Specification. |
| 25 | 3011146, 246NSOR ,\\"Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density in accordance to Table No. 400-12, 400-13 and as per clause of section 406 of specifications of road and Bridge SOR of MP PWD .\\" |
| 26 | 3006147,SOR 13.2.2 15 mm cement plaster on the rough side of single or half brick wall of mix..1:6 (1 cement : 6 sand) |
| 27 | 3004887,SOR 5.3.1Reinforced cement concrete work (with 20 mm nominal size graded stone aggregate) in beams, suspended floors, roofs having slope of any degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level and upto floor two level excluding the cost of centering, shuttering, finishing and reinforcement in concrete grade...M-20 Grade Concrete |
| 28 | 3006436,SOR 15.2.2 Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in- Charge. ...Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix). |
| 29 | 3004924,SOR 5.16.1 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS 456 RCC Design & SP 34 Reinforcement detailing ) etc. complete ........Mild steel and Medium Tensile steel bars. |
| 30 | 3006206,SOR 13.41(Distemparing and Apex painting work of TLM office building and 4 bay shed ) Providing and applying white cement based putty of average thickness 1 mm, of approved brand over the plastered wall surface to prepare the surface even and smooth i/c all cost of material, labour and scaffold etc in all position complete.Note : Putty shall be applied only on the internal walls, for application on the exterior walls prior permission of APD/Chief Engineer will be required. |
| 31 | 3006211,SOR 13.46Wall painting by any mechanical or manual means with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work |
| 32 | 3009431,SOR 31.3.3 Supply and fixing Led tube rod comprising of LED tube with non-integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106(2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job...Tube light LED 1 X 18Watt, Integral i/c batten aluminium body, PC diffuser. |
| 33 | 3009305,SOR 29.7.5Supply and fixing in position LED lamp of approved make...9 Watt250Volt |
| 34 | 3006337,SOR 14.36 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work (TLM office building and 4 bay shed inside ) |
| 35 | 3006363,SOR 14.51.2 Finishing walls with Acrylic Smooth exterior paint of required shade : …...Old work (One or more coat applied @ 0.90 ltr/10 sqm). (TLM office building and 4 bay shed outside ) |
| 36 | 3006338,SOR 14.37 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work. |
| 37 | 3005210,SOR 9.17.2( Fixing of door in Almirah at TLM Office Harda ) Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked ..25 mm thick |
| 38 | 3005335,9.69.3Providing and fixing ISI marked stainless steel handles with necessary screws etc. complete…...75 mm |
| 39 | 3005329,9.66.4 Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with necessary screws etc. complete : …..100x10 mm Please Enable Macros to View BoQ information |