| 1 | Supplying, Fabrication and Installation of 4 mtr. high pole made out of 65 mm dia NB, B class G.I pipe ISI marked duly welded with MS base plate of size 300 mm x 300 mm x 12 mm thick with stiffener of size 130 mm x60 mm x 5 mm thick ,supplying and fixing of suitable size of bracket for mounting the light fitting on the pole, suitable earth stud on base plate , making suitable size hole in pole at a height of 2.5 meter from base plate for cable entry/exit, painting & numbering of pole, making suitable size hole in base plate for cable entry/exit into the pole and fixing the pole on the existing foundation with the nuts-bolts, washers etc. complete as required. |
| 2 | Providing and laying in position1:1.5;3 ( 1 cement: 1.5 Coarse sand : 3 graded stone aggregate) reinforced cement concrete foundation of size 400 mm x 400 mm x 1200 mm deep (800 mm below ground level and 400 mm above ground level) for item no. 1 including excavation of earth, refilling, providing, cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm. dia-1350mm long (approx.) -8 Nos, and reinforcement ring of cold twisted bar of 8mm dia -1800 mm long (approx.) -9 nos, (with 150 mm spacing) including centring & shuttering as required with providing, fixing and positioning of one set of foundation bolts comprising of 4 nos., 16 mm dia, 750 mm long J-Type MS bolts (Threaded portion shall be galvanized) along with 3 nos. GI nuts and 2 nos. GI washers etc. per bolt and 1 no. anchor plate (3mm thick) of suitable size and providing 63 mm.(O.D) DWC/HDPE pipe ISI marked for cable entry & exit etc. complete as required. |
| 3 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K/4000°K/5700°K/6500°K(As per ANSBin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 45 watt |
| 4 | Supply & installation of pole connector box made out of Glass Reinforced Polyester Sheet Moulding Compound to IS : 13410-1992 grade S1 of approx. dimensions 240 mm(H) x 130 mm(W)x 95 mm (D) (all the corners of the box should be round & not pointed ones) suitable to mount on 40/50/65/80 mm dia GI pole with the following provisions/accessories mounting in box complete as reqd.(i)2 nos. clamps made out of 19mm x 3 mm M.S. strip of suitable length for mounting box on the pole.(ii) Water tight front cover with 2 nos. stainless steel hinges & 1 no. screw for tightening.(iii)4 way, 220 V, 30 A, dough moulded connector (SMC with stainless steel inserts)(iv) 5/6 amp. SPMCB 'C' Curve 10 kA---1 no.(v) Suitable size hole at suitable location on rear/bottom wall for cable & wire entry.(vi) Earthing bolt M6 x 20 mm |
| 5 | Supply of following sizes of XLPE insulated & PVC sheathed armoured aluminium conductor power cable of 1.1 KV grade confirming to IS :7098 (Part 1) i/c testing etc complete as reqd. |
| 6 | 2C x 10 sq. mm |
| 7 | 4C X 50 sq. mm |
| 8 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.a)3 x 1.5 sq. mm |
| 9 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 10 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.a) Above 35 sq. mm and upto 95 sq. mm |
| 11 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.a)Upto 35 sq. mm |
| 12 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring/cable as required. |
| 13 | Supplying, installation, testing and commissioning of feeder pillar with floor mounted Light control LT feeder pillar cubical type double door of suitable size as approved by Engineer-in-Charge duly compartmentalized and with general arrangement made out of 2mm thick CRCA sheet having hinged gasket cover and screwed knobs with double locking arrangement and rain protection covers 100 mm and supported with of MS angle iron legs and bottom frame of suitable size as approved by engineer-in-charge grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles wherever required, painting, numbering including supply and fixing of following accessories complete etc. as required. (a)100 A,30KA,FPMCCB Ics=100% Icu ----1 No. (Incomer)(b)16 Amps. SP MCB ('C'-Series), 10 kA------ 6 Nos. (Outgoing circuit)(c) Digital astro Timer switch for daily operation having Power Reserve up to 150 hrs, Inbuilt Override Facility, High Switching Capacity and toggle switch for auto/manual --1 No. (d) Minimum 40 Amps. AC-3, 3 pole power contactor -----1 No. (e) 63 Ampere 4 way neutral link/connector ------2 Nos. (f) Digital Voltmeter (0-500 Volt) 96mm X 96mm 3 phase with selector switch ---1 No (g) Phase Indicating Lamp Set with fuses ----1 Set (h) Danger notice plate -----1 No (i) AI. Bus Bar 100 amp. 4 strip, 300 mm long with sleeve and nut bolts-----1 Set. (j) Digital Ammeter (0-30Amp) 96mm X 96mm 3 phase CL 1.0----1No.(k) Lifting hook on the top of panel board and lighting arrangement inside the feeder pillar---- 1 No. (l) 63 Amps. TP MCB ('C' Series), 10KA- 3 No (Outgoing) for service feeder(m) 32 Amps. DP MCB ('C'-Series), 10 kA------ 1 No.n) ASS- 1 No., VSS- 1 No., AMSS-1 No., Push Buttons 2 Nos., CTs., CL.-1.0, TAPE INSULATED, SUITABLE VA, 100/5A -3 nos., RYB indication- 1 no. each |
| 14 | Supplying, fabrication and installation of wire mesh protection frame for existing feeder pillar made out of 10 SWG MS wire mesh (75mm x 25mm rectangle nominal) of following sizes with angle iron base frame 40 mm x 40 mm x 6 mm angle iron and with MS strip support of size 35 mm x 6 mm and 0.5 mtr. long leg support of same angle as per drawing including providing of suitable size of door with supply & fixing of godown lock including locking arrangement, painting and grouting of angle iron frame with legs in CC (1:2:4) foundation etc. as approved by Engineer-in-charge complete as required.a) 1.5 mtr (W) x 1.00 mtr(D) x 2.00 mtr. (Height). |
| 15 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 16 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 17 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 18 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.a) 100 A,30KA,FPMCCB |
| 19 | SITC of outdoor type SS Enclosure suitable to accommodate 100A FPMCCB with provision for 3 phase cable entry & exit from bottom/side, din channels, terminal, spreaders, external bracket for fixing on wall/mounting on pole including drilling holes, making connections, testing etc. complete as required. |
| 20 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10 cm including inscription duly engraved as required. |
| 21 | Fabricating supplying and Installation of wiremesh protection guard made out of 10 SWG MS wiremesh suitable for 45 watt LED street light fitting as per approved by Engineer-in-charge including painting etc. complete as reqd. Please Enable Macros to View BoQ information |