| 1 | S&F pre- painted galvalume aluminum zinc corrugated steel based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping serews as specified and directed by Engr - in - Charge. |
| 2 | Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings including ridges complete all as specified and directed. |
| 3 | M&L for Fe 410-W (Gde E-250 quality A) Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 4 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 5 | S&F PVC (SWR) pipes 150 mm bore single socketed in any length with rubber ring joints fixed to wall/truss/purleen complete including bends,sockets, etc and S & F Stack clamps made out of 50x5 mm flat iron as required for length, 16mm dia round iron as required length stays including bolts & nuts and securing endsall as specified and directed. |
| 6 | M&L for Fe 410-W (Gde E-250 quality A) Framed work as in doors or gates of angle or other section with gusset plates,rails,braces etc complete,drilled for fixing of steel sheeting or other covering. Doors,etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening anf fixing complete all as specified and directed. |
| 7 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 8 | M&L for two coats synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc all as specified and directed by Engr - in - Charge. |
| 9 | M&L preparation of new or old steel surfaces of any description n exc 10cm in width or girth and priming with red oxide zinc chrome and applying two coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge |
| 10 | Demolition of RCC of any description and in any position not other wise specially provided for reinforcement cut as required to facilitate demolition complete all as specified and directed. |
| 11 | M&L for pre cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregate as in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 complete all as specified and directed. |
| 12 | M&L for Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 13 | M&L for finishing cement concrete even and smooth using extra cement complete all as specified and directed. |
| 14 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 15 | M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate in Surface channels and drains etc complete all as specified and directed. |
| 16 | M&L Random rubble masonry walling well bonded, bedded, solidly hearted, uncoursed built in CM 1:6.Complete all as specified and directed. |
| 17 | M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 18 | M&L for rendering 20 mm thick in CM 1:6 on stone masonary surface, finishing even and smooth without using extra cement complete all as specified and directed. |
| 19 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 20 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 21 | M&L for rendering 15mm thick in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement complete all as specified and directed. |
| 22 | M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed. |
| 23 | M&L for add or deduct for each 25mm girth or part thereof over or under 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed. |
| 24 | Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 25 | M&L for preparing new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed |
| 26 | M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed. |
| 27 | Excavating in post holes (or similar holes) each n.exc 0.5 cum getting out making good the disturbed surface if required in soft/ loose soil complete all as specified and directed. |
| 28 | M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate in foundation filling and mass concrete all as specified and directed. |
| 29 | S&F in repair 100 mm long butt hinges stainless steel with galvanised mild steel hinge pin anodised type B-21 complete all as specified and directed. |
| 30 | S&F in repair 100 mm size extruded stainless steel handles fabricated type anodised of complete all as specified and directed. |
| 31 | S&F in repair 75 mm long stainless steel barrel tower bolts of extruded section complete all as specified and directed. |
| 32 | S&F 75 mm long Hasp and staple, stainless steel, including bolt to hinge plate and fixed with screws |
| 33 | S & F magnetic catcher catcher with nut and screw of mild steel bright finish all as specified and directed. |
| 34 | S & F 40 mm dia cupboard knobs fixed with nuts screw and washer of mild steel bright finish complete all as specified and directed. |
| 35 | S&F in repairs 18/19 mm thick high density PVC/ WPC solid fibre board with prelaminated PVC sheet as Kitchen cupboard and frame including taking down the old cupboard shutters and removing to store complete all as specified and directed. |
| 36 | S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to Fe-410-W (Gde E-250) quality-A or Fe-290 (Gde-E-165) complete all as specified & directed. |
| 37 | M& L Grinding and polishing mirror-ploished laidover with coloured wax for Khondaite stone/ garnet vertical surfaces up to 12 mtr complete all as specified and directed by Engr-in-Charge. |
| 38 | Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed. |
| 39 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base flooring 100 mm thick complete all as specified and directed. |
| 40 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed. |
| 41 | M/L Vitrified Ceramic tiles 10 mm thick (square/ rectagular) dark/light colour shade polished,area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floors over 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 42 | M&L Vitrified Ceramic tiles 10 mm thick on vertical surface of wall of size not exceeding 0.36 sqm,as in dado/skitting including 10 mm thick rendering in CM 1:4 complete all as specified and directed |
| 43 | M&L for Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 300 mm to 450 mm internal dia of pipe complete all as specified and directed. |
| 44 | S&F reinforced concrete pipes, class NP-2, laid and jointed complete with collars of 300mm dia as in repair complete all as specified and directed. |
| 45 | S&F reinforced concrete pipes, class NP-2, laid and jointed complete with collars of 450mm dia as in repair complete all as specified and directed. Please Enable Macros to View BoQ information |
| 46 | S&F reinforced concrete pipes, class NP-2, laid and jointed complete with collars of 450mm dia as in repair complete all as specified and directed. Please Enable Macros to View BoQ information |