| 1 | Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to or from store complete all as specified and directed |
| 2 | Taking down chowkhat or frames exc 1.50 Sqm and n exc 4 Sqm each with shutters (without taking off shutters from the frame) and removing to or from store complete all as specified and directed |
| 3 | Taking down shutter of any description area not exc.1 sqm each and removing to or from store complete all as specified and directed. |
| 4 | Taking down shutter of any description area exc. 1 sqm but n exc 2 sqm each and removing to or from store complete all as specified and directed. |
| 5 | Taking down and Refixing of shutter of any description not exc 1 sqm each leaf in same opening after easing and adjusting building hard ware etc complete all as specified and directed |
| 6 | Taking down and Refixing of shutter of any description exc. 1 sqm but not exc 2 Sqm each leaf in same opening after easing and adjusting building hard ware etc complete all as specified and directed |
| 7 | S&F Second class hard wood (Sal) plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 8 | S&F Second class hard wood 30 mm thick factory made glazed and skeleton shutters, open rebated and prepared to receive glass,gauze etc with out sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,gauze etc, sizes of members of shutters as specified in SSR part I section 8 clause 8.24 (a) complete all as specified and directed. |
| 9 | S&F Second class hard wood 30 mm thick factory made glazed and skeleton shutters, open rebated and prepared to receive glass,gauze etc with out sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,gauze etc, sizes of members of shutters as specified in SSR part I section 8 clause 8.24 (b) complete all as specified and directed. |
| 10 | S & F 35 mm thick second class hard wood rail and style plain, framed, factory made panelled shutters (Two panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and stiles are as per IS – 1003 (Part – I), kiln seasoned & chemically pressure treated complete all as specified and directed. |
| 11 | M&L in repair 12 mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work incl taking down old cupboards etc. complete all as specified and directed. |
| 12 | S&F 6 mm thick teak wood liping 12 mm width prelaminated particle board fixed with screws complete all as specified and directed. |
| 13 | S & F in repair Continuous (piano) hinges, 40 mm width of mild steel, bright finish or electrogalvanisd complete all as specified and directed. |
| 14 | S&F in repaur Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed. |
| 15 | S&F 2nd class hardwood Beads, straight (any size) for glazed or gauzed joinery, renewed, including mitres etc., and removing old beads to Store |
| 16 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4 mm fixed with stainless steel wire staples or with necessary beads complete all as specified and directed. |
| 17 | M&L Mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings,frame work of watertanks and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed. |
| 18 | S&F in repair 100 mm long butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised type B-21 complete all as specified and directed. |
| 19 | S&F in repair 75 mm long butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised type C-21 complete all as specified and directed. |
| 20 | S&F in repair 150 mm size extruded aluminium alloy handles fabricated type anodised of complete all as specified and directed. |
| 21 | S&F in repair 100 mm size extruded aluminium alloy handles fabricated type anodised of complete all as specified and directed. |
| 22 | S&F in repair 150 mm long aluminium,anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 23 | S&F in repair 100 mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 24 | S&F in repair 250 mm long aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 25 | S&F in repair floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor, over all length of cover plate 150 mm complete all as specified and directed. |
| 26 | S&F in repairs Aluminium Mortice lock 2 lever, vertical type, size 100 mm with escutcheon plates and two keys complete all as specified and directed. |
| 27 | S&F in repairs Aluminium Mortice lock 4 lever, vertical type, size 100 mm with escutcheon plates and two keys complete all as specified and directed. |
| 28 | S&F in repair UPVC Door lock complete all as specified and directed. |
| 29 | Dismantling of wall and ceiling boards (fibre,pulp,insulation,etc)or insulation boards/slabs/blankets,any thickness,including cover fillets. complete alll as specified and directed |
| 30 | Providing & fixing false ceiling at all heights with Semi perforated 12 mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture,design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of mainT runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-inCharge. |
| 31 | M&L for applying 3 mm thick wall care Putty in two layers on ceiling surfaces absolutely free from any kind of foreign materials and making good minor cracks etc. and surfaces absolutely even and smooth, rubbing with sand paper including and applying two coats of Oil bound distemper on ceiling complete complete all as specified and directed. |
| 32 | S&F anodised aluminium snap grid frame work for false ceiling consists of grid size 605x605mm complete |
| 33 | Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified |
| 34 | M&L 4 mm thick non AC fibre cement building board classic type of size 605x605mm fixed or laid/inserted to aluminium framework complete |
| 35 | Taking down wall panelling and similar work complete alll as specified and directed |
| 36 | S & F Moulding as in cornices, picture rails and the like exc 13 & n.exc 25 sqcm Fillet wrought complete all as specified and directed. |
| 37 | M&L 12 MM thick Plywood, grade BWP, type BB fixed with screws to timber frame work complete all as specified and directed. |
| 38 | M & L 1 or 0.90 mm thick Decorative laminate type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per maker's instructions complete all as specified and directed. |
| 39 | S&F 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as shown on drawing in section 8 of SSR-2010 Part-II complete all as specified and directed |
| 40 | S&F solid PVC Wall Lining consisting of 5mm thick Plain colour printed PVC Sheet inclusive of solvent cement and fixing at site on PVC Frame all as per specified and directed. |
| 41 | M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 42 | M&L for preparation of old painted surfaces of wood and wood based surfaces of any description, over 10 cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed. |
| 43 | Hacking out old broken glass (any thickness, size quality or description) form wooden frames or steel,Alu, concrete or brick surrounds glazed with oil putty or fixed with beads complete all as specified and directed. |
| 44 | S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane, complete all as specified and directed. |
| 45 | S&F in repair 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 46 | Taking down aluminium door and windows/ventilator of any size and of any description built in wall and making good at disturbed surface with cement mortar 1:4 and applying two coats of plastic emulsion paint as per existing treatment complete all as specified & directed. |
| 47 | S&F Powder coated Aluminium anodised glazed side hung door shutters with anodised aluminium frame of section of 100x44x2mm and bottom rail of 44.5x99x1.8mm including 5.5mm thick tinted sheet glass ordinary quality with all necessary suitable push & pull plate/handle , screw, jointing cleats, rubber packing aluminium snap beading and 1 No 200mm long Aluminium tower bolt, 100mm long 3 No Aluminium butt hinges B-21 Type and one No mortice brass lock 100 size 4 leaver (Vertical Type) with 01 No door closer Aluminium (Diie cast) body hydraullically regulated designation ;No 02 universal type, for each shutters complete all as specified; and ;directed |
| 48 | S&F Powder coated three track Aluminium sliding window with frame not less than 1.8 mm thick including 4 mm thick tinted glass, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket, aluminium snap beading & necessary rubber packing, locking, roller & opening arrangement, incl Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm, all fitting and fixtures complete all as specified and directed by Engr-In-Charge |
| 49 | S&F Powder coated Aluminium Ventilator with frame not less than 1.8 mm thick & including 4 mm thick tinted glass including beading & necessary rubber packing, locking & opening arrangement if required, all fitting and fixture complete all as specified and directed. |
| 50 | S&F 6 mm thick aluminium grills of god quality surrounded by aluminium 'C' channel with mesh size 75 X 75mm incl taking down old grills of any type complete all as specified and directed. |
| 51 | S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed. |
| 52 | S&F in repair door closer hydraulically regulated designation No 2, universal type, suitable for door shutter of weight not more than 60 Kg of aluminium (extruded section body) complete all as specified and directed. |
| 53 | Taking down rolling shutters of any size complete all as specified & directed. |
| 54 | S&F in repair MS pipe 50 to 125 mm dia as shaft including two coats of aluminum paint over a coat red oxide primer complete all as specifed & directed. |
| 55 | S&F in repair part of steel rolling shutters MS gear box set general complete incl handle and anchoring rod as of approved quality all as specified and directed. |
| 56 | S&F in repair Ball bearing suitable for rolling shutter complete all as specified and directed. |
| 57 | S&F in repair Guide channel 3\\" (3.50 mm thick) mild steel deep channel section etc.complete all as specified and directed. |
| 58 | S&F in repair Hood Cover made of 1 mm thick GI Sheet pattern |
| 59 | S&F in repair Bottom plate 5\\" (2.25mm) complete all as specified and directed. |
| 60 | S&F in repair Anchoring rod of 25 mm dia of MS pipe complete all as specified and directed. |
| 61 | S&F in repair Safety lever locks MS with 4 levers complete all as specified and directed. |
| 62 | Taking down and refixing in the same opening steel rolling shutter including oiling and greasing to required necessary fitting to functionall shutters as required bush, Spring. MS pipe , rod .lock. ball bearing, top cover, anchoring rod, hasp and staple and push pull or gear operating system , bevel gear box and crank handle etc complete all as specified.and directed.(area of rolling shutters exc 6 sqm but n. exc. 18 Sqm each )(Note:- Necessary constituent items required during repair of rolling shutter shall be paid seperately as given above .) |
| 63 | S & F in repair Complete rolling shutter including 1.00 mm thick mild steel rolling shutter strips duly pressed on both ends of vertical sides for interlocking locks for the required length of existing steel rolling shutter including oiling and greasing to required necessary fitting to functionall shutters as required bush, Spring. MS pipe , rod .lock. ball bearing, top cover, anchoring rod, hasp and staple and push pull or gear operating system , bevel gear box and crank handle etc complete all as specified.and directed. as directed by Engg-in-Charge |
| 64 | S & F in repair 1.00 mm thick mild steel rolling shutter strips duly pressed on both ends of vertical sides for interlocking locks for the required length of existing steel rolling shutter complete all as specified.and directed. as directed by Engg-in-Charge |
| 65 | M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 66 | M&L preparation of old decorated Steel painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge |
| 67 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 68 | Demolition of brick work built in cement mortar including all quions, arches, pillars etc all as specified and directed |
| 69 | M & L for brick work with sub class \\"B\\" brick (old size) straight or curved on plan to any radius in half brick thick walls built in CM 1:4 to any radius complete all as specified and directed. |
| 70 | M & L for brick work with fly ash bricks straight or curved on plan exc 6m mean radius in CM 1:4 including demolition of brick work or stone/ boulder masonry, built in cement mortar completed all as specified and directed. |
| 71 | M&L for rendering 10 mm thick on other than fair face of brick works in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed. |
| 72 | M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick or concrete surface of wall and finished even and smooth with out using extra cement and mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed.(Note: supply only of WPC shall be measured and paid for seperately) |
| 73 | M&L for preparation of new decorated surfaces of walls and apply one coat of white wash complete all as specified and directed |
| 74 | Demolition of stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 75 | M & L brick work with fly ash bricks, Straight or curved onplan exc 6m mean radius,built in 1:6 in cement mortar all as Specified and Directed |
| 76 | M & L for brick work with sub class \\"B\\" brick (old size) straight or curved on plan to any radius in half brick thick walls built in CM 1:4 to any radius complete all as specified and directed. |
| 77 | Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 78 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface of wall and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 79 | M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surface of wall and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 80 | M&L 5mm thick rendering in CM 1:3 on ceiling surfaces even and smooth without using extra cement complete all as specified |
| 81 | Supply only integral water proofing compound all as specified and directed. |
| 82 | M&L for Preparation of Newly Plastered surfaces of Wall and applying Two coats of Oil Bound Distemper over a coat of primer all as specified and directed. |
| 83 | M&L for preparation of newly plastered surfaces of wall applying two coat of white wash over a coat of primer all as specified and directed. |
| 84 | M&L Preparation of Newly Plastered surfaces of Ceiling and applying Three coats of White Wash complete all as specified and directed. |
| 85 | M&L for Preparation of old surfaces of Wall by brooming down or steel wire brushing, scraping down smoke soot, moulds, mass and efflorescent salts, trading oil and greasy spots etc and applying One coat of white wash over old decorated surface of walls all as specified and directed by Engineer-in-Charge. |
| 86 | M&L for preparation of old plastered surfaces of ceilings and apply one coat of white wash complete all as specified and directed. |
| 87 | M&L for preparation of old distempered surfaces of walls and applying one coat of oil bound distemper on walls all as specified and directed. |
| 88 | M&L for Complete Removal of existing treatment including preparation of old treated surface and applying Two coat of oil bound distemper over 3 mm thick wall care putty including preparation all as specified and directed. |
| 89 | M&L for complete removal of existing treatment incl preparation of New/ old decorated surfaces of wall and applying two coat of cement based paint complete all as specified and directed. |
| 90 | Preparation of Newly Plastered surfaces and applying two coat of Cement Base Paint on walls all as specified and directed by Engineer-in-Charge. |
| 91 | M&L for Preparation of old surfaces of Wall and applying one coat of Cement Base Paint on walls all as specified and directed by Engineer-in-Charge. |
| 92 | M&L for preparation of existing sunken floor treatment incl plaster and removal of all debris with the following specification and sequence complete all directed by Engr-In-Chrg (a) Cleaning internal surface areas of sunken thoroughly to remove all dirt & loose materials by various mechanical/manual means.(b) Providing and making fillets at the junction of the walls and the slabs using CM 1:4. (c) Laying protection plaster 15mm th. in CM 1:4 on floor and wall with integral water proofing compound (d) Applying two coats of Epoxy resin polymer modified cementitious coating like brushbond of FOSROC/ Dr. Fixit Fastflex/ Bostic Powermix both on floor and wall of sunken. |
| 93 | Demolition of cement concrete unreinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed. |
| 94 | M&L for PCC 1:5:10 type E-2 using 40mm graded stone aggregate as in filling of sunken floor etc and mass concrete complete all as specified and directed. Please Enable Macros to View BoQ information |
| 95 | M&L for PCC 1:5:10 type E-2 using 40mm graded stone aggregate as in filling of sunken floor etc and mass concrete complete all as specified and directed. Please Enable Macros to View BoQ information |