| 1 | Supply, lay and connect end terminals of XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 core 10 sq. mm , with alumium lugs for cable end terminals complete all as specified and directed. |
| 2 | Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5m in depth for laying of cables/pole foundation and getting out of excavated material complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed. |
| 4 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. |
| 5 | Supply and laying double walled corrugated HDPE pipe of nominal size 50 mm ( inner dia approx 38 mm) along with accessories to pipe joints , as per IS: 16205 part-24, The pipe shall be with the following properties: outer wall corrogated, inner wall plain surface, preferably orange colour,Anti rodency,Non-flame propagation property, permanently lubricated silicone inner layer for smooth cable insertion,Anti-termite property, Pliable , to be used for cable protection & laid in trench complete all as specified and directed |
| 6 | Material and labour for PCC 1:2:4 type B2 using 40 mm graded stone aggregate for bollard base footing including necessary form work and fair finishing exposed surfaces and inserting suitable size PVC conduit pipe for cable entry & exit inside foundation, incl foundation nut - bolts of the bollard light to be grouted in the foundation, incl two coat painting of foundation with exterior plastic emulsion paint including plaster, putty etc. as required for smooth surface complete all as specified and as directed by the Engineer-in-Charge. |
| 7 | Supply and fix pole mounting type FRP cable looping box with connector , of inside dimension 280mm x 235mm x 135mm , with DIN Rail for fixing MCB , including brass gland (two nos.) of size selected based on outer dia of 4C x 10 sqmm cable (approx. 22 mm) and the looping box to be fixed on bollard light with suitable flat iron arrangement / flushed into foundation platform complete all as specified and as directed. |
| 8 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, complete with connection testing and commissioning complete all as specified and as directed. |
| 9 | Material and labour for submain wiring in replacement with two run single core 1.5 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 1.5 sq mm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 20 mm dia including conduit accessories all as specified and directed. Note: Three runs of 1.5 Sqmm cable and one run of 20 mm conduit will be measured as one unit length. |
| 10 | Supply , installation, testing and commissioning of outdoor LT feeder pillar box in replacement , CPRI Approved , factory fabricated in an factory having modern fabrication and testing process which includes seven tank pre-treatment process comprising of degreasing, rinsing, de-rusting , rinsing, phosphatising, rinsing and passivation followed by power coat painting having thickness not less than 100 microns . The doors shall be provided with suitable gasket and latc including PCC foundation for erecting the panel board. Feeder piller shall be suitable to accommodate the following as specied and as directed.:- OUTER SHELL : The outer shall be made out of 3.15 mm thick CRCA sheet &MS angle section 50x50x6 mm frame, factory fabricated with front & back openable, double door system lockable/openable by keys from both sides having chromium plated locks. ‘U’ type gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate of thickness 3.15 mm powder coated having provision for entry of armoured cable of adequate size with glands. The outer shell shall be powder coated Siemens grey structural RAL 7032 shade. INNER SHELL : inner shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, front & back open able single door system lockable / openable by keys from both sides having chromium plated locks (2 Nos in each compartment),having louvers & air vent gasket for natural flow of air.The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size ‘F’ class insulator made on non hygroscopic, non combustile , track resistant, high strength FRP/SMC/DMC material at an interval not more than 500mm throughout the length of the TPN bus bar for the following panel The bus bar chamber comprising of high conductivity aluminium bus bar of capacity 200 Amps three phase and half the capacity for neutral. INCOMING(a) MCCB 415 V,63 A, 4 pole breaking capacity 16 KA- 01 Nos. (b) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, with LED indication complete and all as per standard practice ---1 Job OUT GOING(a) MCB 25 A, 415V , TPN , B Curve - 04 Nos |
| 11 | Supply and fix LED bollard light fitting 7 W or nearest higher wattage,230v, with following parameters: Luminous Flux 150 lm, Luminous Efficacy (rated) (Nom) 21.43 lm/W, Optical cover type Polycarbonate bowl/cover UV-resistant, Housing Material Aluminum extruded, Mounting device Baseplate, Overall height 800 mm, Ingress protection code IP65 , Mech. impact protection code IK10 and along with anchor bolts complete all as specified and as directed. Make : PHILIPS Model No BCP150 LED150/(NW or WW) PSU 220-240V 7043 Or its equivalent in Havells/CG/ Bajaj |
| 12 | Supply ,install and testing 2.0 TR Split Air conditioner inverter type 3 Star rating with indoor and outdoor units (copper condenser coil, copper cooling coil and evaporator including required length of copper tubing and cables for connecting indoor and outdoor units ) complete with cordless remote control unit , with inverter rotary compressor with inbuilt air ioniser and plazma filter for better indoor air quality complete ,all as specified and as directed by Engineer in Charge : Note : Rate quoted is inclusive of the following:- (i) Drilling hole on the brick wall to facilitate routing of Copper pipe, drain pipe and cable from indoor unit to outdoor unit. (ii) Sealing the hole from outside ,after installation, with white cement.(iii) Pressure testing , cooling performance check and product demonstation. (iv) cable for connecting indoor and outdoor unit upto 3.00 Mtr each.(v) Material and labour for fixing Remote stand in wall and outdoor unit stand.(vi) Copper pipe, upto 3.00 Mtr each.and drain pipe up to 5 mtr 15 mm dia |
| 13 | All as per item No.12 above but 1.5 TR Split Air conditioner Complete |
| 14 | Supply and fixing Copper pipe with foam insulation including connecting, complete all as specified and directed of following size:1/4\\" |
| 15 | Supply and fixing Copper pipe with foam insulation including connecting, complete all as specified and directed of following size:1/2\\" |
| 16 | M&L for single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 240 V, 20 Amp complete all as specified and as directed by the Engineer in Charge |
| 17 | Supply and Fix PVC drain pipe flexible type of 20 mm size complete all as specified and directed. |
| 18 | M & L for sub main wiring complete with two single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit heavy grade and conduit accessories including 4 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note: 3 run of 4 sqmm & one run of PVC conduit shall be measured as single unit |
| 19 | Supply and fix Voltage stablizer 5KVA, 230 volt for Split AC suitable for 2.0 ton capacity all as specified and directed |
| 20 | Supply and fix Voltage stablizer 4KVA, 230 volt for Split AC suitable for 1.5 ton capacity all as specified and directed Please Enable Macros to View BoQ information |