| 1 | Cleaning of blocked CI, SGSW pipe of 100 mm bore from gully trap/WC to first manhole by rodding/choke remover manually as in foul condition after taking off the manhole cover and placing the manhole cover (Old) in position including sealing around manhole cover where required(i) The complaint has to be rectified within 08 hrs as given in complaint register, failing which penalty will be imposed @ Rs.100/- per complaint per day. |
| 2 | Cleaning of sewage lines of 150 mm dia and above including manholes by using chassis-mounted diesel-driven, hydraulically operated high-pressure suction-cum-jetting sewer cleaning machine (KAMBI-10 LCHB or equivalent) fitted with standard pumps having minimum 3000 litres suction capacity, operated by skilled operator with supervisor/engineer, for cleaning/partial desilting of manholes and sewer lines in accordance with IS 11972:1987, including complete cleaning of site, complete all as specified and as directed by Engineer-in-Charge; jetting of sewer lines shall be carried out by high-pressure system of minimum 2200 PSI, water required for cleaning shall be arranged by the contractor at his own cost, and the work shall be executed on ‘as and when required’ basis for required lengths at various locations. |
| 3 | M&L for dewatering/cleaning of liquid or low-density sludge including foul water/waste water from inspection chambers, pits, manholes (not exceeding 1.50 m depth), soakage wells and sumps by using water-suction hydraulic pressure machine or pumping out as required, including removal of light silt, loose deposits and residue of both organic and inorganic nature, not requiring extensive manual scraping or repeated operations, in any position and at any depth, including minor manual cleaning by labour wherever required to remove residual deposits, measured and paid per unit cleaned. |
| 4 | M&L for dewatering/de-sludging/pumping out of liquid or semi-solid waste including foul water/waste water from inspection chambers, pits, manholes (exceeding 1.50 m depth), soakage wells, sumps and grease traps (including mess grease traps irrespective of depth) by using water-suction hydraulic pressure machine and manual/mechanical means, including removal and thorough cleaning of heavy sludge, grease deposits, thick/semi-solid waste, silt and residue of both organic and inorganic nature, requiring repeated pumping, scraping and handling, in any position and at any depth, including manual cleaning by labour wherever required to remove residual deposits, measured and paid per unit cleaned. |
| 5 | Note for item No. 3 and 4:-Rates must include disposal of collected waste outside MoD land at authorised disposal site as per prevailing rules of local authorities, complete all to facilitate proper functioning, as specified and as directed by Engineer-in-Charge. |
| 6 | Removing floor/Nahani trap cover, cleaning the trap by removing greasy substances, sludge etc with or without use of chock remover manually ensuring free flow of waste water, fixing of new PVC trap cover using neat cement paste complete all as specified |
| 7 | Cleaning of the existing drain pipes of 150mm internal dia up to 1.50 mtr depth by roding manually as required at site from manhole and well flushing after cleaning including getting out the sludge if any and liquid materials from connecting manholes, deposited in lines including removing the solids and sludge to outside defence land by covered transport and cutting the bushes around the manholes and on the route of the sewer line upto 1 metre width complete all as specified. |
| 8 | All as per item No 6 here-in-before but for 200mm dia and depth from 1.5 to 3.00 mtr depth including cutting bushes around the manholes and on the route of sewer line upto 1 metre width complete all as specified |
| 9 | Demolition of brickwork built in cement mortar complete all as specified NOTE: Demolished material to be removed outside MD land |
| 10 | M&L for brick work with subclass 'B' Bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:4) complete all as specified |
| 11 | M&L 100mm thick PCC (1:2:4) type B0 by using 12.5 mm graded stone aggregate as in flooring mixed with WPC as recommended by manufacturer including finishing the concrete surface smooth & even using extra cement complete all as specified |
| 12 | M&L for 15mm thick rendering in cement mortar (1:4) to brick/concrete wall surfaces finished even & smooth (without using extra cement) with water proofing compound at the rate of 3% by weight of cement or as per the manufacturer’s instructions complete all as specifiedNote: WPC shall be measured and paid for separately |
| 13 | Supply only liquid water proofing compound complete all as specified |
| 14 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified. Note: Demolished material to be removed outside MD land |
| 15 | M&L for providing and fixing precast RCC covers with RCC frame/collar for manholes, inspection chambers and drains, of approved design, type and load capacity (solid or with suitable openings if required), of shape (round/rectangular/square) and size as per site conditions, cast in cement concrete 1:2:4 or equivalent, including all necessary fixing in position, complete all as specified and as directed by Engineer-in-Charge |
| 16 | M&L for providing plain cement concrete (1:4:8) type D-2 by using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 17 | M&L for 150 mm RCC drain pipes, NP2 laid in trenches and jointed including demolition & breaking up of 150 mm bore drain pipes (salt glazed ware, AC or reinforced pipes) set in cement mortar and providing plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in concrete bed to drain pipes of 150 mm bore including packing under and haunching against the sides of pipe after they are laid and tested including necessary excavation, RFR & earthwork upto 3 m depth in any type of soil, removal of demolished materials outside of MD land etc complete all as specified. Note:- During excavation any damage to the existing cable/pipeline shall be rectified by the contractor and no extra claim whatsoever shall be accepted. Contratcor's supervisor shall be present during excavation. Excavation work shall be undertaken by mechanically or manually as per the direction of Engr-in-Charge as per the ground conditions. |
| 18 | M&L for 200 mm RCC drain pipes, NP2 laid in trenches and jointed including demolition & breaking up of 200 mm bore drain pipes (salt glazed ware, AC or reinforced pipes) set in cement mortar and providing plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in concrete bed to drain pipes of 200 mm bore including packing under and haunching against the sides of pipe after they are laid and tested including necessary excavation, RFR & earthwork upto 3 m depth in any type of soil, removal of demolished materials outside of MD land etc complete all as specified. Note:- During excavation any damage to the existing cable/pipeline shall be rectified by the contractor and no extra claim whatsoever shall be accepted. Contratcor's supervisor shall be present during excavation. Excavation work shall be undertaken by mechanically or manually as per the direction of Engr-in-Charge as per the ground conditions. |
| 19 | M&L for 300 mm RCC drain pipes, NP2 laid in trenches and jointed including demolition & breaking up of 300 mm bore drain pipes (salt glazed ware, AC or reinforced pipes) set in cement mortar and providing plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in concrete bed to drain pipes of 300 mm bore including packing under and haunching against the sides of pipe after they are laid and tested including necessary excavation, RFR & earthwork upto 3 m depth in any type of soil, removal of demolished materials outside of MD land etc complete all as specified. Note:- During excavation any damage to the existing cable/pipeline shall be rectified by the contractor and no extra claim whatsoever shall be accepted. Contratcor's supervisor shall be present during excavation. Excavation work shall be undertaken by mechanically or manually as per the direction of Engr-in-Charge as per the ground conditions. |
| 20 | S&F in repair 100mm dia cast iron soil waste pipe in any length with or without ears with cement joints laid in trenches or in floors incl necessary earth work complete all as specified |
| 21 | S&F in repair 100mm dia cast iron soil waste pipe and vent pipes in any length with or without ears with cement joints fixed to walls complete all as specified |
| 22 | S&F in repair 75mm cast iron soil (sand cast) waste and vent pipes in any length with or without ears with cement joints fixed to walls complete all as specified |
| 23 | S&F in repair 100mm CI Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified |
| 24 | M&L for providing plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in copings, benching etc. complete all as specified |
| 25 | Cutting of bushes, weeds, vegetation etc removing all the waste to a distance exceeding 250mtr from storm water drain, oxidator pond, installations etc complete all as specified |
| 26 | M&L for removing silt/soil, any description from the storm drains of size not exceeding 3 metre depth and 3 metre wide and removing the same to a distance not exceeding 1000 metres and depositing where directed complete all as specified |
| 27 | M&L for repair to MS framed manhole cover made out of angle iron and/or MS flats frame and covered with MS sheet of required thickness as per site conditions, including welding, cutting, straightening, fitting, providing/repairing hinges, including replacement of unserviceable parts and applying two coats of red oxide, complete all as specified and as directed by Engineer-in-Charge |
| 28 | M&L for rendering 15mm thick in cement mortar (1:4) to brick or concrete wall surfaces finished even & smooth without using extra cement with/without water proofing compound at the rate of 3% by weight of cement or as per manufacturer instructions including taking down the cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water etc before applying rendering complete all as specified. |
| 29 | M&L for rendering 10mm thick in cement mortar (1:6) to brick or concrete wall surfaces finished even & smooth without using extra cement including taking down the cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water etc before applying rendering complete all as specified. |
| 30 | S&F in repair vitreous china squatting pan “ORISSA PATTERN” size 580mmx440mm ‘white’ with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe anti syphonage pipe etc complete all as specified and as directed. NOTE:- Old dismantled IWC should be thrown outside MoD land. |
| 31 | S&F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe) including seat cover with CP screw complete all as specified and as directed. NOTE:- Old dismantled WC should be thrown outside the MoD land |
| 32 | S & F in repair PVC low level cistern of 10 lit capacity inclusive of brackets and PVC bend long type and connecting to flush pipe of any size and pattern with inlet ball valve float and handle etc complete all as specified & directed. |
| 33 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all respect as specified and directed. |
| 34 | S & F 110 mm bore of pipe PVC (SWR) pipes double socket in any length with rubber ring joint fixed to walls with MS clamps as directed |
| 35 | S & F 110 mm bore of pipe PVC (SWR) bends with access door of any radius / shoe fixed to PVC pipes as directed |
| 36 | M&L for two coats of cement based paint over a coat of white wash on new surfaces of walls including preparation of surfaces complete all as specified Please Enable Macros to View BoQ information |
| 37 | M&L for two coats of cement based paint over a coat of white wash on new surfaces of walls including preparation of surfaces complete all as specified Please Enable Macros to View BoQ information |