Tender For Special Repair To Septic Tank, Soakage Well, Manhole And Sewage Pipe Line At Prc, Ramgarh Cantt
Tender Value
24.17 Lakhs
Estimated cost
Bid Submission
06 Jul 2026
5 days left
EMD
48347
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ramgarh → Jharkhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Septic Tank, Soakage Well, Manhole And Sewage Pipe Line At Prc, Ramgarh Cantt
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed. |
| 2 | Excavation in trenches in soft & loose soil not exceeding 1.5 metre wide and exceeding 1.5 mtr depth but not exceeding 3m depth and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed. |
| 3 | Returning, filling in including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge. |
| 4 | Removing of excavated materials to a distance not exceeding 50m and depositing where directed at a levelnot exceeding 1.5m above the starting point in soft/loose soil complete all as specified. |
| 5 | Demolition and breaking up drain pipes of 150mm dia (SGSW/AC/RCC/PVC) set in cement mortar including bed concrete and removal of debris to low lying area of distance not exceeeding 100m complete all as directed by Engr-inCharge. |
| 6 | M & L 100 mm thick moorum/red bajari filling in trenches laid in layers not exceeding. 15cm thick, spread, levelled and rammed includingwatering, compacted to require gradient etc complete all as specified and directed. |
| 7 | S&F, for Rain and waste infrastructure pipe made of polyethylene (HDPE) of 150mm dia class DWC pipe SN-8 (IS-16098 part2) laid and jointed with collars in trenches and jointed to make sewer line functional complete all as specified and as directed by Engr-in-Charge |
| 8 | S&F, for Rain and waste infrastructure pipe made of polyethylene (HDPE) of 200mm dia class DWC pipe SN-8 (IS-16098 part2) laid and jointed with collars in trenches and jointed to make sewer line functional complete all as specified and as directed by Engr-in-Charge |
| 9 | S&F, for Rain and waste infrastructure pipe made of polyethylene (HDPE) of 300mm dia class DWC pipe SN-8 (IS-16098 part2) laid and jointed with collars in trenches and jointed to make sewer line functional complete all as specified and as directed by Engr-in-Charge |
| 10 | M&L for plain cement concrete 1:3:6 ,type C-2 (using 40 mm graded crushed stone aggregate) as in foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and as directed by Engr-in-Charge |
| 11 | Demolition of cement concrete reinforced as in precast cover of manholes, etc(reinforcement cut as required to facilitate demolition),including removal of rubbish out off MOD land etc complete all as specified and directed |
| 12 | M&L for precast reinforced cement concrete 1:2:4 ,type B-1 (using 20 mm graded crushed stone aggregate) as in manhole, etc. including necessary formwork complete all as specified and directed. Note : Reinforcement will be measured & paid seperately under respective item of BOQ. |
| 13 | M&L for mild steel TMT bars 10 mm dia and over grade Fe -500 , as in reinforcement ,cut to length, bent to shape required, including cranking bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. |
| 14 | Demolition of brick work of any description and in any position built in cement or cement lime mortar including all quoins, arches, pillars including segregation of serviceable bricks for reuse & removal of rubbish out off from site etc complete all as specified and directed. |
| 15 | M&L for Brick work using old size sub class \\"B\\" bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed. |
| 16 | M&L for Brick work using old size sub class \\"B\\" bricks but except bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed. Note:Old serviceable brick as retrieved.from item No 14 of BOQ here-in -before. |
| 17 | M&L for plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded crushed stone aggregates) as in kerb /benching /copings /leveliing course/window cill etc. including weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form work etc complete all as specified and directed |
| 18 | Taking down cement plaster on brick or stone wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etc & removing the debris from the premises upto 500 m from the MOD land complete all as specified and directed |
| 19 | M&L for rendering 15 mm thick on brick or concrete surface etc., in cement mortar 1:4, surface finished even & smooth without using extra cement complete all as specified and directed. |
| 20 | .M & L for conventional type RCC septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, RCC M-30( Design mix) in walls, base slab, baffle walls and roof slab including beams etc., with vent shaft manhole openings with cover connection etc., complete with effective depth of 1.5m and overall depth of 3 metre for 50 Users, complete all as per drawing No. CEJZ/TD/987, SHT 1/2 &2/2 . |
| 21 | .M & L for conventional type RCC septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, RCC M-30( Design mix) in walls, base slab, baffle walls and roof slab including beams etc., with vent shaft manhole openings with cover connection etc., complete with effective depth of 1.5m and overall depth of 3 metre for 100 Users, complete all as per drawing No. CEJZ/TD/987, SHT 1/2 &2/2 . |
| 22 | M & L for conventional type Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick of size 1.2m x3m effective depth complete all as per drawing No. CEJZ/TD/58, SHT 1/1 |
| 23 | .M & L for Conventional type soakage well 1.80 m dia and 3.00 m deep( effective depth), excavation in any type of soil, foundation in PCC (1:3:6) ,walls of honey combed masonry with top ring of M-25/SFRC cover concrete , interconnecting pipes of RCC/DWC, complete filled with brick bats of size complete all as per drawing No. CEJZ/TD/58, SHT 1/1 |
| 24 | Cleaning of septic tank of any capacity and any type of material like solid/fluid, mud sludge etc by mechanical motorised suction machine and deposited /removing the sludge etc outside the MoD land shall be conveyed in closed container and also disposed off by digging pit and fill up earth in the place properly using bleaching powder etc using bleaching powder etc complete all as directed by Engr - in -Charge. Note: Date of cleaning of Septic Tank with location shall be recorded in MB for record purpose. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 22, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysJul 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 days