| 1 | Taking up or down 15mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 2 | Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 3 | Taking up or down 25 or 32 mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 4 | Taking up or down 40 or 50mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 5 | Taking up or down 80mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed. |
| 6 | Refixing of 15mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 01 above) |
| 7 | Refixing of 20mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 02 above) |
| 8 | Refixing of 25 to 32mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 03 above) |
| 9 | Refixing of 40 or 50mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 04 above) |
| 10 | Refixing of 80mm bore old serviceable steel tubing and connections in new or old position with new fittings complete to walls and ceilings or laid in floors, etc complete as directed. (Note: Serviceable pipe shall be reused as obtained from serial item No. 05 above) |
| 11 | Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. |
| 12 | Supply, laying, connection and testing, 20mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. |
| 13 | Supply, laying, connection and testing, 25mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. |
| 14 | Supply, laying, connection and testing, 40mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. |
| 15 | Supply, laying, connection and testing, 50mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. |
| 16 | Supply, laying, connection and testing, 80mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. |
| 17 | Cutting chases in brick wall, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting n.exc 10 cm girth complete all as specified and directed. |
| 18 | Taking down eaves gutters and rainwater/soil/waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed |
| 19 | S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed. |
| 20 | S & F 75 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc complete all as specified and directed. |
| 21 | S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed. |
| 22 | S & F 75 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed. |
| 23 | S & F 110 mm bore, PVC (SWR) bends of any radius with oval access door complete all as specified and directed. |
| 24 | S & F 75 mm bore, PVC (SWR) bends of any radius with oval access door complete all as specified and directed. |
| 25 | Dismantling 100mm bore, cast iron or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches if required and as directed. |
| 26 | Dismantling 75mm bore, cast iron or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches if required and as directed. |
| 27 | M & L for 100mm bore, Cast iron, sand cast soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls etc with all fixing accessories complete all as specified and directed. |
| 28 | M & L for 100mm bore, Cast iron, sand cast soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed. |
| 29 | M & L for 75mm bore, Cast iron, sand cast soil, waste and vent pipes in any length with or without ears, with cement joints, with cement joints, fixed to walls etc with all fixing accessories complete all as specified and directed. |
| 30 | M & L for 75mm bore, Cast iron, sand cast soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed. |
| 31 | M & L for 100mm bore, cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed. |
| 32 | M & L for 75mm bore, cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed. |
| 33 | M & L for 100mm bore, cast iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and directed. |
| 34 | M & L for 75mm bore, cast iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors complete all as specified and directed. |
| 35 | S & F in repairs Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100mm bore of pipe complete all as specified and directed. |
| 36 | S & F in repairs, 100 mm bore, Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 37 | S & F in repairs, cast iron nahani trap 100 mm dia with grating including jointing to waste pipe fixed in cement mortar 1:2:4 type B2 using 20mm graded aggregate complete all as specified and as directed. |
| 38 | M & L for 100 mm bore, Jointing only cast iron pipes and fittings or AC pipes and fittings, in repairs, with cement joints complete all as specified and directed. |
| 39 | M & L for 75 mm bore, Jointing only cast iron pipes and fittings or AC pipes and fittings, in repairs, with cement joints complete all as specified and directed. |
| 40 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish to outside MD land complete all as specified and directed. |
| 41 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 42 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 43 | M & L for Glazed, ceramic, coloured tiles of size 300mm x 200mm x 6-7mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 44 | Demolition of un-reinforced cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to outside MD land exc 5 km but nex 15 km complete all as specified and directed. |
| 45 | M & L for applying chemical Injection Treatment in the form of pressure grouting by drilling holes of 20mm dia and 60mm deep @ 100 CM grid at bottom floor and all the internal surface of the sunken slab of toilt by injecting cement slurry mixed with low viscosity epoxy grout @225 gm for 50 Kg of cement and applying minimum 1mm thick two component acrylic polymer modified cementitious coating including testing the same for 48 hours as per the manufacturer's technical specification complete all as specified and as directed Make: (a) Low viscosity epoxy grout = CONBEXTRA EP 10 of M/S Fosroc or equivalent product of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. (b) Two component acrylic polymer modified cementitious coating = Brushbond RFX of M/S Fosroc or equivalent product of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. |
| 46 | M & L for rendering 15 mm thick in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement mixed with water proofing compound as per manufacturer's instructions complete all as specified and directed. (Note: WPC shall be measured and paid seperately) |
| 47 | Supply only integral water proofing compound (ISI marked) complete all as specified and directed. |
| 48 | M & L for Plain cement concrete 1:5:10, type E-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. |
| 49 | M & L for 40 mm thick (average), plain cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) as in flooring, etc mixed with water proofing compound as per manufacturer's instructions complete all as specified and directed. (Note: WPC sall be measured and paid seperately) |
| 50 | Complete removing the plants from the surfaces of the building with complete roots, applying recommended chemical to prevent further growth as directed, making good the disturbed surface with cement mortar 1:3 and applying the same surface finish of the existing surface and finished to match with the surrounding surfaces including removal of debris etc., out side the premises complete all as required complete all as specified and as directed. |
| 51 | S & F in repairs, vitreous China squatting pan, 'Orissa' pattern, size 580 x 440 mm white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications complete all as specified and directed. |
| 52 | S & F in repairs Semi-Pedestal pattern (Anglow-Indian type), vitreous China water closet pan, white, with 'P' or 'S' trap, including flushing pipe, seat cover, etc complete and making good to disturbed surfaces of floor by filling with PCC 1:4:8 type D-2 to match with the existingscomplete all as specified and directed. |
| 53 | S & F in repairs, 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed. |
| 54 | S & F in repair Vitreous China, wash basin, White, flat back of size 450 x 300 mm including cutting for and pinning in ends of brackets or erecting stand but exclusive of waste pipe etc complete all as specified and directed. |
| 55 | S & F in repairs, 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed. |
| 56 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish to outside MD land complete all as specified and directed |
| 57 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed. |
| 58 | M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 59 | M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed. |
| 60 | M&L for preparation of new platered surface of wall and applying two coats of oil bound distemper over a coat of primer including applying one or more coat of wall care putty to a smooth surface including making good any undulations on the surfaces complete all as specified and as directed. Note :- Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS |
| 61 | M&L for preparation of new platered surface of wall and applying two coats of weather proof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre, dart pick up resistant,silicon enhanced,UV resistant and PU enhanced property over a coat of alkali resistant primer including applying two coats of wall care putty exterior grade to a smooth surface including making good any undulations on the surfaces including all necessary scaffolding,complete all as specified and directed. Note :- Painting work shall be carried out acoording to Smart Painting procedure mentioned in PS |
| 62 | M & L for preparing old decorated surfaces of walls including cornices, pilasters etc by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of white wash complete all as specified and directed. |
| 63 | M & L for preparing old decorated surfaces of ceiling including cornices, pilasters etc by bromming down or by steel wire brushing, scrapping down smokes soot, moulds, moss and efflorscent salt and treating oil and greasy spot and applying one coat of white wash complete all as specified and directed. |
| 64 | Demolition of reinforced cement concrete in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed. |
| 65 | M & L for use & waste Form work to chajjas, troughs and similar items including edges flat for rough finished surfaces of concrete complete all as specified and directed. |
| 66 | M & L Reinforced Cement Concrete 1:1.5:3, Type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in chajjas etc complete all as specified and directed.(Note : Reinforcement will be measured & paid seperately) |
| 67 | S & F high strength corrosion resistant TMT steel bars 6mm to 8mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 68 | S & F high strength corrosion resistant TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 69 | Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish outside MD land as directed by the Engr-in-Charge. |
| 70 | M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed. |
| 71 | M & L for brick work with fly ash bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls using old size brick complete all as specified and directed. |
| 72 | S & F in repair 15 mm bore, gun metal, globe or Gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 73 | S & F in repairs, 20 mm bore, gun metal Gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 74 | S & F in repair 25 mm bore, gun metal, globe or Gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 75 | S & F in repairs, 40 mm bore, gun metal Gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 76 | S & F in repairs, 50 mm bore, gun metal Gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 77 | M & L for cleaning and degermination inside the PVC water storage tanks of capacity not exceeding 500 ltr of any description and in any position comprising the following seven stage cleaning and sterilization of water tanks through bacteriological treatment by using TERBAC G5/INCHLOR-5/NB-10, TERBAC G65/INOXI-60/NB-69 and ultra violet rays complete all as specifiedand as directed.(a) 1st stage: Drain out the water by using exit valve or with high capacity dewatering system or any other suitable method approved by Engr-in-Charge.(b) 2nd Stage: Cleaning all the algae formation inside the tank by using TERBAC G10/INCHLOR-5/NB-10, (a laboratory tested branded chemical) and scrubbing the walls of the tanks.(c) 3rd stage: Cleaning with fresh water by high speed jet pump with pressure of 5 PSI.(d) 4th stage Sterilization by using TERBAC G5/INCHLOR-5/NB-10, (a Laboratory certified branded halogen compound) for first bateria screening.(e) 5th stage: Cleaning the floor of the water tank by heavy duty industrial vaccum cleaner.(f) 6th stage: Sterilizing method by using ultra violet ray Ejector covering 360 degree with in the tank and kills all suspended bacteria for 2nd bacteria screening.(g) 7th Stage: Cleaning and sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agend TERBAC G65/INOXI-60/NB-69 for third bacteria screening.Note:- (i) Test certificate of TERBAC G65/INOXI-60/NB-69 etc from Government Laboratory mentioning suitability for sterilization should be submitted to the Dept before using for Sterilization. (ii) Cleaning of tank shall only be carried by the authorised service provider of the material used. Necessary approval shall be obtained from GE before cleaning of the tanks, (iii) After cleaning of the tank necessary completion certificate confirming the completion of sterilization of water tank shall be issued by the service provider and a sticker shall be fixed on the tank duly mentioning the date of cleaning and name of site etc) |
| 78 | All as per Serial item No. 77 above but PVC tank of capapcity exc 500 and n.exc 1000 Litres complete ditto |
| 79 | S & F in repair PVC over head tank cover suitable for tank of capacity exc 500 but n.exc 1000 Litres complete all as specified and directed. |
| 80 | S & F in repairs, 32mm dia flexible PVC waste pipe for wash basin/sink etc complete all as specified and directed |
| 81 | S & F in repairs, 40mm dia flexible PVC waste pipe, 750mm long for wash basin/sink etc complete all as specified and directed |
| 82 | Supply, hoisted and fixing in position 1000 Ltrs capacity rotational moulded polyethylene water storage tank, double layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified & directed including taking down old unserviceable one as specified in SSR Part I and directed. |
| 83 | Supply, hoisted and fixing in position 500 Ltrs capacity rotational moulded polyethylene water storage tank, double layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified & directed including taking down old unserviceable one as specified in SSR Part I and directed. |
| 84 | S & F in repair 15 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 142 gms) complete all as specified and directed. |
| 85 | S & F in repairs, 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed. |
| 86 | S & F in repairs, 25 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 455 gms) complete all as specified and directed. |
| 87 | Demolition of cement concrete (unreinforced) in any position not otherwise specifically provided for as in roof padding etc including old detoriated roof treatment and bedding layer and removing debries and rubbish to a distance outside MD land complete all as specifed and directed. |
| 88 | M & L for brushing neat cement slurry with 3.00 Kg of cement per Sqm complete all as specified and as directed |
| 89 | Material & labour for 25 mm thick cement concrete (1:2:4) type B-0 using 12.5 mm gaded stone aggregate laid on RCC roof slab to make surface levelled for proper slope finish the surface even and fair complete all as specified and as directed. |
| 90 | M&L for preparation of horizontal or vertical surfaces for water proofing treatment on existing cleaned non accessible RCC roof with the following specification and manufacturings instruction complete all as specified and as directed:-(a) Preparing and cleaning of fully dry surfaces as per IS3067-1966(b) Applying bitumen primer(85/25 grade)conforming to IS:3384-1968 over the cleaned plaster surface @ 0.5 Ltr per sqm by the same membrane manufacturer of density at 25°C, 0.87 to 0.89 kg / Liter and viscosity 70-160 cps shall be applied on the prepared surface.(c) Applying a layer of APP based polymeric membrance 3.0mm thick (minimum) weight 3.6Kg per sqm (reinforced) with polyster Non woven fabric weighing not less than 160gms per sqm by torch application.The over laps shall be minimum 100mm on the transverse direction and 75 mm on longitudinal direction. (d) Applying one coat of aluminium paint @0.10 ltr per sqm over APP based polymeric membrane. |
| 91 | S & F in repairs, stainless steel sinks made of 1 mm thick sheet with plugs, washers and wastes including bedding in ement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm and bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 92 | S & F in repairs 20 mm bore, Brass chromium plated, tubular towel rail, D type, 60 cm long between flanges with brackets complete all as specified and directed. |
| 93 | S & F in repairs, 15mm bore, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 94 | S & F in repairs, 15 mm bore, Stop valves, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 95 | S & F in repairs, 15 mm bore, Stop valves, cast copper alloy, chromium plated with long shank and cup, concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 96 | S & F in repair 15 mm bore, angular stop valve, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 97 | S & F in repair 15 mm bore, CP Health Faucet with 8mm Dia, 1.0 Meter Long Flexible Tube & Wall Hook with all accessories complete all as specified and directed. |
| 98 | S & F in repairs PVC syphonic kit (any type/any pattern) suitable for 10 litre capacity low level flushing cistern and making the cistern functional in all respectcomplete all as specified and directed. |
| 99 | S & F in repairs, vitreous China wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe with seat and cover complete but excluding flushing cistern & flush pipe including making good damaged/disturbed surfaces complete all as specified and directed. |
| 100 | S & F in repairs, plastic water closet, Seat and Cover for pedestal pan, white / black, closed pattern with flat bottom and mild steel chromium plated or aluminium hinging device complete all as specified and directed. |
| 101 | S & F in repairs 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed. |
| 102 | S & F in repair stainless steel Grating, 100mm dia with or without waste hole fixed with white cement complete all as specified and as directed. |
| 103 | S & F in repair 125 mm size, shower rose, brass chromium plated, swivel type, complete all as specified and directed. |
| 104 | S & F in repairs float handle as per the existing specifications suitable for 10 litre capacity low level flushing cistern and making the cistern functional in all respect complete all as specified and directed. |
| 105 | S & F in repairs brass spindle (heavy) suitable for bib taps/stop valve of 15mm bore all as per the existing specifications complete all as specified and directed. |
| 106 | M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 107 | S & F in repairs, stainless steel kitchen sinks with drainage board made of 1 mm thick sheet for kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 108 | S & F in repair 600mmX450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with chromiun plated brass screws and cup washers complete all as specified and directed. |
| 109 | S & F in repairs, 15 mm bore CP, wall mixer for mixing hot & cold water with provision for overhead shower with 115mm long bend pipe on upper Side, connecting legs & wall flanges complete all as specified and directed. |
| 110 | S & F in repair 40 mm dia, Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc including all fitting as required complete all as specified and directed. |
| 111 | S & F 40 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 112 | S & F in repairs, 20mm bore, GI Nipple suitable for HDPE water tank (Minimum weight 45gms) complete all as specified and directed. |
| 113 | S & F in repairs, 25mm bore, GI Nipple suitable for HDPE water tank (Minimum weight 65gms) complete all as specified and directed. |
| 114 | Clearing wash basin/kitchen drainage block from the waste pipes by romving grating and removing waste materials from the traps, bends etc carefully and roding with flexible GI wire to clear the blocking including dipositing the waste materials complete all as directed by the Engr-in-Charge |
| 115 | Clearing blockage from soil pipes or from WC by carefully roding soil pipe with split bamboos or flexible GI wire etc including cleaning the toilet by flushing water and disposing any removed soil materials complete all as directed by the Engr-in-Charge |
| 116 | S & F in repairs Soap dish of standard size, stainless steel, fixed in walls with plugs & chromium plated brass screws complete all as specified and directed. |
| 117 | S & F in repair Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed. |
| 118 | Taking down vitreous China wash basin or sink of any size with backets and refixing in the same position after replacement of brackets as per the existing specification complete all as specified and directed. |
| 119 | M & L for Filling of cement mortar in sides of nahani trap, gully trap, rain water pipes out let etc. in CM 1:3 including WPC @ 2% by weight of cement or as per manufacturers instructions and making good finishes to arrest leakage / seepage complete all as specified and as directed. |
| 120 | S & F in repairs 20 mm bore, aluminium anodised, tubular towel rail, D type, 60 cm long between flanges with brackets complete all as specified and directed. |
| 121 | S & F in repairs, Stainless steel, kitchen plate rack of size 24x30x10 inch as per existing design and specification as approved complete all as specified and directed. (Make: Prayag Cat No. P-330 or equivelant of make as per list of manufacturer's) |
| 122 | Supply, laying, connection and testing, 16 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 123 | Supply, laying, connection and testing, 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 124 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 125 | S & F in repairs Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100mm bore of pipe complete all as specified and directed. Please Enable Macros to View BoQ information |