| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 2 | M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:6) for bedding of tiles complete all as specified. |
| 3 | M&L for 10 mm thick rendering in cement mortar (1:4) on vertical surfaces for backing of tiles complete all as specifed. |
| 4 | M&L for Non - skid (joint free) coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. |
| 5 | M&L for Coloured Vitrified Ceramic tiles 9-10 mm thick (Square/rectangular) of light Shade , polished, area of each tile not exceeding 0.36 sqm, fixed in floor/skirting etc over set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles complete all as specified. |
| 6 | M&L for double charged coloured Vitrified Ceramic tiles 9-10 mm thick (Square/rectangular) of light Shade , polished, area of each tile exceeding 0.36 sqm and n. exc 0.72 sqm and , fixed in floor/skirting etc over set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles complete all as specified. |
| 7 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangle) area of each tile exc 0.06 sqm but not exc 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile complete all as specified and as directed. |
| 8 | M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified. |
| 9 | Demolition of Mud in roofs, any thickness including plastering and leeping, (whether full thickness removed etc including roof tiles complete all as specified and as directed. |
| 10 | Demolition of cement concrete (un-reinforced) of any description & in any position not specifically provided complete including dismantling of floor tiles etc complete all as specified. |
| 11 | M&L for 50 mm thick PCC (1:2:4) type B-0 (Using 12.50mm graded stone aggregate) as in roof padding complete all as specified & as directed. |
| 12 | M&L for 15 mm thick plaster in cement mortar (1:4) mixed with water proofing compound on roof slabs finished even and smooth (without using extra cement) after cleaning of roof surfaces with wire brushes complete all as specified.Notes : WPC shall be measured and paid seperately. |
| 13 | M&L for water proofing treatment with APP (Atactic Polypropylene) modified polymeric prefabricated five layer membrane over roof consisting of cleaning of concrete or plaster surface of roof & parapet walls and applying evenly a bitumen primer confirming to IS 3488 @ 0.40 Kg per sqm laid using buten torch and sealing all joints of APP modified polymeric water proofing membrane minimum weight 3.6 kg/sqm reinforced with non woven polyester fabric (weight not less than 160 grams per sqm) unrolled and bonded to substrata with logitudinal and end laps 100 mm and 150 mm respectively as per manufacturer's instructions complete all as specified. |
| 14 | Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified. |
| 15 | M&L for providing plain cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in coping in chajjas or roof kerbs on roof chamfered on edge including trowelling slightly complete all as specified. |
| 16 | M&L for Cement concrete tiles 25cm x 25cm x 22 mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished, set with grey cement and pigments over 15mm thick cement screed bed in cement mortar 1:4 complete all as specified and directed. |
| 17 | Supply only intergral water proofing compound ISI Marked complete all as specified. |
| 18 | Removing bldgs demolished materials / debries exc. 1.50 km but n exc. 5 km and depositing where directed. |
| 19 | M&L for preparation of plastered or unplastered old decorated surfaces by complete removal of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible , filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying two coat of oil bound distemper over a coat of primer on walls complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer. (c) Wall care putty shall be measured and paid seperately. |
| 20 | All as per item No.19 here-in-before but on surfaces of ceiling. |
| 21 | M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality on wall/ceiling surface including applying 1-2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and as directed.Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer. |
| 22 | M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling/roof sheet surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7\\"/9\\" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint ( Camouflage Pattern) over priming coat premium quality on wall/ceiling surface including applying 1-2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat.(b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer. |
| 23 | M&L for providing 3mm thick wall care putty on wall before applying oil bound distemper and making the surface uniform all as specified. Note: OBD to be measured and paid saperately. |
| 24 | M&L for providing 3mm thick wall care putty on ceiling before applying oil bound distemper and making the surface uniform all as specified. Note: OBD to be measured and paid saperately. |
| 25 | M&L for preparation of old treated plastered or unplastered surfaces of walls including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with putty and applying one coat of distemper oil emulsion on walls complete . |
| 26 | M&L for preparation of old treated plastered or unplastered surfaces of ceiling including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with putty and applying one coat of distemper oil emulsion on ceiling complete . |
| 27 | M&L for preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth by cleaning, sand papering,brushing etc , filling in cavities and cracks etc with approved filler and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified . |
| 28 | M&L for preparing old painted surfaces of steel and iron surfaces over 10 cm in width or girth by cleaning, sand papering, brushing with wire brushes, scrapping by steel scrappers etc and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified . |
| 29 | M&L for preparation of old painted concrete surface plain/kerb stone moulded over 10cm width or girth by cleaning, brushing etc and applying one coat of synthetic enamel paint all as specified and as directed. |
| 30 | Demolition of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified. |
| 31 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified. |
| 32 | M&L for brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified. |
| 33 | M&L for half brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:4 etc complete all as specified. |
| 34 | M&L for 5 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceiling including finishing surface even and smooth without using extra cement. |
| 35 | M&L for 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:6 on walls including finishing surface even and smooth without using extra cement |
| 36 | M&L for 15 mm thick plaster in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement) complete all as specified. |
| 37 | M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified. |
| 38 | M&L for preparation of newly plastered surface of ceiling and applying two coats of oil bound distemper over one coat of primer complete all as specified |
| 39 | M&L for preparation of newly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality complete all as specified |
| 40 | M&L for preparation of newly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint ( Camouflage Pattern) over a coat of primer premium quality complete all as specified |
| 41 | M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint on walls. complete all as specified. |
| 42 | Disconnecting existing PVC water tank of capacity exc. 250 ltr but not exc. 500 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified. |
| 43 | Disconnecting existing PVC water tank of capacity exc.500 ltr but not exc. 1000 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified. |
| 44 | Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 liters but not exceeding 500 litres complete all as specified. |
| 45 | Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 500 liters but not exceeding 1000 litres complete all as specified. |
| 46 | S&F for rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position all as per SSR Part I complete all as specified. |
| 47 | S&F for rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position all as per SSR Part I complete all as specified. |
| 48 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. |
| 49 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. |
| 50 | Cutting chases, pinning in. making good to facings where required andpointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall etc complete all as specified. |
| 51 | S&F medium grade galvanized steel tubing with all fittings & fixed complete to walls & ceiling or laid in floors 15 mm dia bore pipe (including in short length) complete all as specified. |
| 52 | S&F tubes medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors 20 mm dia bore pipe (including in short length) complete all as specified. |
| 53 | S&F in repair 20 mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified. |
| 54 | Dismantling wrought iron or mild steel work of any description |
| 55 | S&F rolled mild steel in framed work as in doors or steel gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing conforming to Fe- 290.Gde-E-165 complete all as specified. |
| 56 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified. |
| 57 | M&L prepration of new Steel surfaces of any description, not otherwise described, over 10cm width or girth & applying two coats of synthetic enamel paint complete all as specified |
| 58 | Dismantling of Plain or corrugated AC sheet, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified & directed. |
| 59 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws as specified & directed. |
| 60 | S&F in repair steel rolling shutter of thickness 1.25 mm without ball bearing as specified including top cover , anchoring rod , hasp and staple and one shop coat of primer erected in position, gear operated type with bevel gear box and crank handle complete all as specified. |
| 61 | M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified. |
| 62 | M&L for 75 mm thick cement concrete type D-2 1:4:8 with )using 40 mm graded stone aggregates) as in sub base of flooring etc complete all as specified. |
| 63 | M&L sand filling under interlocking tiles for cushioning including watering and consolidation complete all as specified. |
| 64 | M&L for machine presssd pre-cast coloured concrete interlocking paver block any shape confirming to IS-15658-2006 of 60mm thick , M-35 Grade with grey cement and pigment as approved complete all as specified. |
| 65 | M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified. |
| 66 | M&L chequered cement concrete coloured tiles 30cm x 30 cm x 25mm, set jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified. |
| 67 | M&L for cement concrete type B0 1:2:4 (using 12.50 mm graded stone aggregate) as in coping benching, gola, slightly rounded and similar items complete all as specified and as directed. |
| 68 | Taking down wall panelling and similar work all as specified. |
| 69 | S&F for solid colour wood grain printed PVC sheets 5mm thick as in wall panelling inclusive of solvent cement incl necesssary PVC frame work for fixing on brick or concrete wall as per specification and drawing. |
| 70 | Dismantling ceiling board (fiber, pulp insulation) or insulation board/slabs etc including grid work/wooden or aluminium frame works, cover fillet etc Complete all as specified. |
| 71 | M & L for clip in type armed strong metallic powder coated 0.5mm thick ceiling with GI framework made of standard Tee , Angle or any other section as in grid type ceiling framework as approved by GE . Ceiling shall be hanged to roof trusses / purlin rafters with the help of GI wire not less than 4mm dia at an interval n. exc 1m , the size of the metallic powder coated ceiling tiles 600 mm x 600 mm complete all as specified. |
| 72 | S&F in repairs vitreous china squating pan, 'Orissa' pattern, size 580x440 mm white, with integral foot rests, including 100mm cast iron 'P' or 'S' trap and 100mm cast iron sanitary connection socket to fit WC outlet including connection to trap, to flushing pipe, anti-syphonage pipe etc. complete including making good to floor complete all as specified and directed. |
| 73 | S&F in repairs white vitreous China wash down water closet pan (padestal pattern) and trap (excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe anti syphonage pipe etc. complete all as specified and directed. |
| 74 | S&F vitreous china pedestal wash hand basin (flat back) of size 550x400mm including one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector, including cutting for and pinning in ends of brackets complete all as specified. |
| 75 | S&F in reapir Urinal, bowl type or half stall pattern, basin only including connections to flushing pipe and outgoing pipes |
| 76 | S & F in repairs 10 litres capacity, PVC valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and suitable flush pipe PVC 32mm dia complete all as specified and directed. |
| 77 | S&F in repair pillar taps, cast copper alloy, with capstan heads, fancy type chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified. |
| 78 | S&F in repair bib taps, long body, brass, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified. |
| 79 | S&F in repair fancy type Angle stop cock with flange, 15 mm nominal bore, brass, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified. |
| 80 | S&F in repair brass CP mixer for mixing hot & cold water screwed down for iron pipe 15 mm dia and fixed complete all as specified. |
| 81 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook including making connections and mixed in position complete all as specified and directed. |
| 82 | S&F in repair plastic water closet seat, black closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified. |
| 83 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed. |
| 84 | All as per item No.83 here-in-before but exc 1.5 Sqm and not exc 4 Sqm each complete all as specified. |
| 85 | Taking down shutter of any description exc 1 Sqm and n exc 2 Sqm and removing from site. |
| 86 | S&F for Pressed steel frames 125X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified. |
| 87 | S&F for Pressed steel frames 105X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete as specified. |
| 88 | S&F factory made 35mm thick flush shutters , solid core construction with block board core and plywood face pannel commercial type on both faces complete all as specified. |
| 89 | S&F factory made 35mm thick 2nd class hardwood glazed and skelton door shutters, open rebated and prepared to receive glass, gauze, (without sash bars) edges for framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-1 section 8 clause 8.24 (a) fitted to chowkats complete all as specified. |
| 90 | S&F solid PVC door frame of size 50mm X47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing. |
| 91 | S&F factory made PVC shelter panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement , supplying and fixing in the frame at site as per specification & drawing as specified. |
| 92 | S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified. |
| 93 | M&L preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed. |
| 94 | S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified and as directed. |
| 95 | S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified. |
| 96 | S&F 150 mm size extruded aluminium alloy handles fabricated type anodised and fixed. |
| 97 | S&F 250 mm long aluminium alloy anodised sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast sections or cast aluminium alloy complete all as specified and as directed. |
| 98 | S&F in repair 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified. |
| 99 | S&F in repair 150 mm size extruded aluminium alloy handles fabricated type anodised and fixed. |
| 100 | S&F in repair 250 mm long aluminium alloy anodised sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast sections or cast aluminium alloy complete all as specified and as directed. |
| 101 | S&F Powder coated Aluminium frame for doors, windows, ventilators with or more rebates incl. jointing cleat for fixing etc. Complete all as specified. |
| 102 | S&F powder coated anodized aluminum door shutters, aluminum section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door,100 mm long hinges (3 Nos), anodized aluminum snap beading screws etc. complete all as specified. |
| 103 | S&F powder coated Anodised aluminium window and ventilator shutters, fixed/side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified. |
| 104 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. |
| 105 | M&L for 5.5 mm thick sheet glass ordinary quality and glazing each pane fixed with including neopune rubber gasket in aluminium frame work complete all as specified and directed. |
| 106 | S&F window or ventilators section of frame 72x55mm fixed to wall or concrete surface with rowl plugs made of galvanised steel powder coated and section of shutter 47x20mm mulion section 72x50mm (Based steel as per IS 513 \\"D\\" quality galanised as per IS 277 with zinc of 120 gms/sqm) glazed or gauged and wire gauge shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made of square bars powder coated fixed to window frame with screws including necessary fittings and all builders hardware such as handles, tower bolts and stays etc complete all as specified and as directed. Make : NCL type-4000 Series (Note : Glass and wiremesh shall be included under respective items) |
| 107 | M&L for cement concrete 1:5:10 type E-2 using 40mm graded stone aggregates as in sunken portion of WC etc complete all as specified and as directed |
| 108 | M&L for rendering 15 mm thick in CM (1:3) mixed with water proofing compound @ 3% by weight of cement finished even and smooth without using extra cement in sunken portion of toilet including one coat of bitumen coating of bitumen 85/25 grade at the rate of 1.2 kg per sqm including cleaning surfaces etc complete all as specified and as directed. Note: WPC will be measured and paid separately Please Enable Macros to View BoQ information |