Defence Statutory Bodies & Commissions/Committees Closing in 24 days TDR #56120539

Tender For Provn Of Storage Sheds And Ancillary Buildings At Munakot (Phase-Ii).

Issued by Statutory Bodies & Commissions/Committees · Pithoragarh, Uttarakhand
Tender Value
90.60 Crore
Estimated cost
Bid Submission
28 Jul 2026
24 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pithoragarh → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Storage Sheds And Ancillary Buildings At Munakot (Phase-Ii).

BOQ

Name of Work:- PROVN OF STORAGE SHEDS AND ANCILLARY BUILDINGS AT MUNAKOT (PHASE-II).
Sl. No. Item Description
1SCHEDULE 'A' PART-I (BUILDING WORK)
2Construction of 4.2 M high Ammunition lab (RCC Framed Structure) with VIFT all around the bldg (all three sides and front side) including traverse earth filling, RCC Retaining wall for VIFT portion , toe wall , dwarf wall and including 4 M wide front side loading and unloading platform & verandha, 1.2 M wide two sides platform, ramps, gravity rollers, plinth height 1.2 m , including plinth protection with PCC saucer drain all around the building etc in accordance with STEC pamphlet - 3 complete all as specified, shown on drawing and directed.Note :- PQC road and hard standing at front side of building and PCC saucer drain all around the VIFT traverse area shall be measured and paid separetaly under respective Schedule.
3Construction of 4.2 M height RCC URP building block (RCC framed Structure) for 04 x URP chamber (Every chamber size 14 m x 14 m x 4.2 m) in one block with URP blast wall for Each door ( size of RCC blast wall 10 m x 30 cm x 5 m height) including three sides - 3 m wide loading and unloading platform , two side ramp, steel doors , plinth height 1.2 m in accordance with STEC pamphlet - 3 etc complete all as specified, shown on drawing and directed.Note :- (i) URP Drawings as CFEES/URP HD 1.3/50 MT/ 4.2 ht Sheet No. 152 to 165. (ii)The drawings mentioned above Note (i) will be followed for the four chamber only including platform , ramps, blast wall for four chamber etc.(iii) The crumple joint will be given between of the third and fourth chamber in the URP building with 3 M wide platform between both chamber. (iv) Total Length = (3 m wide platform+ first chamber + second chamber+ third chamber+ 3 m wide platform including crumple joint + Fourt Chamber+ 3 m wide platform)) (v) Road and hard standing and drain all around the URP building shall be measured and paid separately under respective Schedule.
4Construction of Double storey Main fire station building (RCC Framed Structure) including appliance bay , open repair bay with inspection pit , ramp & sanitary annexeure etc complete all as specified, shown on drawing and directed.
5Construction of Garage for 40 x Scooters (RCC Framed Structure) including ramp etc complete all as specified, shown on drawing and directed.
6Construction of Garages for ALS & Exp Van (RCC Framed Structure) including ramp & apron etc complete all as specified, shown on drawing and directed.
7Construction of Garages for 2.5 Ton & Water Browser Vehicles (RCC Framed Structure) including ramp & apron etc complete all as specified, shown on drawing and directed.
8Construction of Garages for MG & FLT Vehicles (RCC Framed Structure) including ramp & apron etc complete all as specified, shown on drawing and directed.
9Construction of MT Store , Lubrication oil and Grease store (RCC Framed Structure) including ramp & sanitary annexeure etc complete all as specified, shown on drawing and directed.
10Construction of Petrol Store (RCC Framed Structure) including ramp, platform , three sides sand filling etc complete all as specified, shown on drawing and directed.
11Construction of covered repair bay with inspection pit (RCC Framed Structure) including ramp & apron etc complete all as specified, shown on drawing and directed.
12Construction of MI Room building (RCC Framed Structure) with Abmulance Garrage , ramp & sanitary annexeure etc complete all as specified, shown on drawing and directed.
13Construction of Labour's amenity Room Bldg (RCC Framed Structure) with sanitary annexeure etc complete all as specified, shown on drawing and directed.
14Construction of drying and ironing Room (RCC Framed Structure) complete all as specified, shown on drawing and directed.
15Construction of open garage for Cars (RCC Framed Structure) including ramp etc complete all as specified, shown on drawing and directed.
16Construction of MES Maintenance Cell (RCC Framed Structure) including sanitary annexeure etc complete all as specified, shown on drawing and directed.
17Provn of RCC dunnage for Igloo/ESH (Size 300mm x 300 mm x 200mm ) complete all as specified, shown on drawing and directed.
18Total amount of SCHEDULE 'A' Part - II A(INTERNAL WATER SUPPLY)(For details see Sch 'A' in PDF folder)
19SCHEDULE 'A' PART - II B (INTERNAL WATER SUPPLY)
20S & F 15 mm bore two way bib cock with wall flange cast copper alloy , fancy type , chromium plated, screwed for for GI/ iron pipe or for brass ferrule including flange and fixed complete all as specified and directed.
21S&F for brass chromium plated over head shower rose with 300 mm long CP shower arm 120 to 150 mm size (round/square pattern)revolving type multi-flow suitable for fixed to GI pipe and fittings or for unions and fixed complete all as specified and directed.
22S&F for Health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible SS pipe tube and ABS wall hook including making connections and fixed in position complete in all as specified and directed.
23Total amount of Sch 'A' Part III-A(INTERNAL ELECTRIFICATION) (For details see Sch 'A' in PDF folder)
24SCHEDULE 'A' PART III-B (INTERNAL ELECTRIFICATION)
25M & L for Point wiring with PVC insulated PVC unsheathed electric (FRLS) cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (MS boxes for ceiling fans and for light points along with conduit be fixed in ceiling while casting slab for fan point and for light points,in rigid pvc conduit will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including sunk in pressed steel terminal boxes (normal and moduler type) of 1.6 mm thick and including bakelite sheet cover or hylam board of 2.8 mm thick including cutting holes for switches, sockets, regulators etc as per requirement including fixing with machine screw, washer etc for the following and Make of wire- Grandlay/Havells /polycab, Make of the conduit : Kalinga/AKG/Polycab
26(a) One light point / fan point / exhaust fan/ bell point/ security light controlled by one one way switch
27(b) One 3/5 pin socket outlet 5 Amp on the same board with other swithes.
28(c) One 3/5 pin 5 Amps socket outlet on independant board.
29(d) One light point / fan point / exhaust fan/ bell point/ security light controlled by one two way switch
30Supply and fixing Sub main wiring ( concealed type ) with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLS) cable of size 4.0 sqmm LT, 1100V grade, down trhough and incl adequate sizes PVC non metallic medium grade conduit of 25mm/ approprite dia with accessories and fittings and one run of 4 sq mm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic medium grade conduit of 25mm/approprite dia shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe (Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.) Make of Cable- Grandlay/Havells /polycab, Make of PVC conduit - Kalinga/AKG/Polycab
31Supply and fixing Sub main wiring ( concealed type) with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLS) cable of size 6.0 sqmm LT, 1100V grade, down trhough and included PVC non metallic conduit 25mm dia medium grade with with accessories and fittings and one run of 6 sq mm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of in PVC non metallic conduit 25mm dia medium grade shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe (Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.) Make of Cable- Grandlay/Havells /polycab, Make of PVC conduit - Kalinga/AKG/Polycab
32Supply and fixing Sub main wiring ( concealed type) with four runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLS) cable of size 4 x 6.0 sqmm and one run of 6 sq mm single core PVC insulated multi stranded unsheathed copper conductor (Green colour) cable as earth lead connecting to main earth dolly drawn in and including non metallic PVC conduit 25mm dia medium grade conduit concealed inwall complete specified and directed.
33S&F LED Tube light fitting 20 Watt surface and wall mounted LED batten, in PVC body, polycarbonate diffuser & integrated electronic driver complete with all accessories internally prewired and incl connecting up three core single wire complete all as spd and directed . Make : HAVELLS : CAT PART No.LHEXAQP7PN1W020, HSN Code 9405, or Crompton : Model - Bright linea,Cat part No. CCS-100-20-65-HL2-DP-NWH, Make : Bajaj, Cat part No. BCLSB 20 2H.
34S&F Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar ,triple pole and neutral 415volts ,flush to wall complete all as specified and directed. .MAKE-LEGRAND / SCHNEIDER /SEIMENS
35S&F double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated bus bar 8 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /SEIMENS
36S&F double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated bus bar 4 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /SEIMENS
37S&F double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, IP-43, 240 Volts 200 amps rated bus bar 12 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /SEIMENS
38M&L for MCB single pole,6 to 40 Amp 240 volt C curve 10 KA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed MAKE-LEGRAND / SCHNEIDER /HAVELLS/HPL
39S&F Miniature circuit breakers ISI marked 240 Volt, 50 Hz, SPN 40-63 Amps, breaking capacity 10 KA. 'C' curve MAKE-LEGRAND / SCHNEIDER /SEIMENS
40S&F Miniature circuit breakers ISI marked 415 Volt, 50 Hz, TPN 40-100 Amps, breaking capacity 10 KA , C Curve. MAKE-LEGRAND / SCHNEIDER /SEIMENS
41S & F in replacement Switch flame proof rotary type with termination box in LM6, 16A, singlepole 250V.
42Supply and fixing building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 45Watt capacity LED and including all accessories duly pre-wired, fixing on GI bracket 32 mm dia GI pipe medium grade 0.75 M long bend to shape with clamp, nut, bolts and washers as requireded at site for fixing of street light on LT pole/ wall complete all as specified and directed. Make: Havells, Cat Part No ENDURAPEARLNEOSL45LED757SASYTOPC or Crompton- Model No Raptor Pro-I, Cat part No. CRP-409-45-57-SL-GL-NSG,or Bajaj- Model EDGE NXT LED, Cat part No. ENXT P 45L WW CR PC SD
43M & L for point wiring with PVC insulated PVC unsheathed electric (FRLS) cable 1100 v grade single core having multi stranded copper conductor of size 4 Sq mm nominal cross sectional area in and including nonmetallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall and 4 Sq mm (green in colour) PVC insulated unsheathed copper conductor as earth wire connected to earth dolly by providing lugs including terminal type of including sunk in pressed steel boxes (normal / modular 1.6mm thickness and backlite sheet seat cover or HYLAM board of including cutting 2.8mm thick holes for switches, socket. Regulator etc. as per requirement including fixing with machine screw, washer etc. for one three pin socket outlet 15 AMP.
44M&L point wiring complete copper conductor 1.5 Sq mm size (nominal area)PVC insuloated FRLS unsnearned cable 1100 V gradeconforming to IS 694 drawn in and including 1.6 mm thick concealed ER W stove enameled rigidsteel conduit conforing to IS:9537 of size not less than 25mm dia including flame proof fittingssuch as MS junction bos,. MS coupling uninors bends, reducers inspection albow seelingconduits, plugs etc and also including singlecore standed copper conductor 1.5 Sq mm PVC insulated unsheathed FRLS cable as earth wire to common earth adn connected to earth doilyand body of the flameproof lumiaires an drawn in the same concealed conduit complete all as specified and directed for following:-(a) One flame proof light/ fan point controlled by singlepole one way 10 Amp flame proof ON-OFF rotary switch.
45supply and fixing Crompton make 2X20W LED CIMFR certified LED flameproof batten suitablefor single and twin T8 tube o 16W/20W.Recommended for Gas/Vapor group of IIA & IIB and Zone 1 & 2. IP65 Protected. CIMFR - BIS Certified.( EXTN2LT8-16/20-VE + TCS-726-20-65-SL-DPNWH)
46Supply and install flame proof weather proof 12 way SPN MCB DB 240Volts, 50Hz in LM6 construction, consisting of 01 No incoming MCB SPN-40 Amps, MCB SP-6-16Amps (10Nos) as out going with clip on type terminals with suitable cables entries including connecting up incomong and out going cables and makingconnection all as specified and as directed.Make CG or equivalent.
47Supply, installation, testing and commissioning of water heater storage, storage for single phase, 50 Hz AC supply, stainless steel inner assembly, 2 KW heating element, twin thermostat for water temperature and safety thermostat stove enamel outer body including minimum 1 M of three core 2.5 sqmm twisted copper conductor PVC sheathed, three pin plug top, polyethylene pipe connection piece 450mm long of 6kg/sqmm with two sets of chromium plated adopter at each end suitable for 15mm bore GI pipe at cold water inlet and copper tubing connection with chromium plated adopterat ends, at hot water outlet , with safety fusible plug conforming to IS , capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, including 02 Nos of stainless steel leak proof geyser Connections 24\\" long of suitable size not less than 15 mm bore with washers on both sides, fixed on wall complete with all acessories all as specified and directed.
48Total amount of SCHEDULE 'A' PART - IV(SITE CLEARANCE AND EARTHWORK) (For details see Sch 'A' in PDF folder)
49Total amount of SCHEDULE 'A' PART - V A(ROAD , PATH & CULVERT ) (For details see Sch 'A' in PDF folder)
50SCHEDULE 'A' PART - V B(ROAD , PATH & CULVERT)
51M&L for preparing bituminous surfaces of road and marking 2.5 mm thick & exc. 10 cm wide but n.exc 15 cm wide width centre lines, stop lines, dashes, arrows etc. with applying theromoplastic reflective paint using hot mark thermoplastic paint ( Hot application) white/golden yellow by ingredient, modern propelled road special applicator machine all as per manufacturers instruction including all ingredient such as binder glass beads Titanium dioxide calcium carbonate lintar fillers thermoplastic requirement of glass beads shall be as per the table no. 800-4 0f MORTH specification incl spraying of glass beads instruction complete all as directed.
52Total amount of SCHEDULE 'A' PART - VI A(SEWAGE DISPOSAL ) (For details see Sch 'A' in PDF folder)
53SCHEDULE 'A' PART - VI B(SEWAGE DISPOSAL)
54M & L for Construction of septic tank 50 users capacity with excavation and earth work in hard / dense soil, PCC 1:2:4 type B2 in foundation, 200 mm thiick PCC Solid Block Masonry PCC (1:3:6) in CM (1:6), RCC M-25 using 20 mm graded crushed aggregate as specified, duly reinforced with 8mm TMT bar @ 120mm c/c manhole covers, angle iron frame, vent shaft and sludge chamber etc. complete all as specified, directed and shown on drawing No TD - 217 sheet 1/7 to 7/7.
55M&L for Construction of LLDPE conventional septic tank for 25 users designed to carry sewage and sullage water, excavationin any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete with effective depth of 1.5m and overall depth of 3m for 10user scred cover with angle iron frame vent shaft an sludge chambers etc complete for 10 users etc complete all as specified and directed.
56M&L for Construction of LLDPE conventional septic tank for 10 users designed to carry sewage and sullage water, excavationin any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete with effective depth of 1.5m and overall depth of 3m for 10user scred cover with angle iron frame vent shaft an sludge chambers etc complete for 10 users complete all as specified and directed.
57M&L for soakage well with size 1.8 m dia x 3.0 m effective depth including excavation in hard / dense soil, foundation in PCC 1:3:6, walls of honeycombed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of 200 mm thiick PCC Solid Block Masonry PCC (1:3:6) in CM (1:6), RCC cover slab in M-25, interconnecting pipes of RCC complete filled with brick bats complete all as specified and directed.and shown on drawing No TD -309 sheet 1/4 to 4/4.
58M&L for soakage well with size 2.4 m dia x 4.5 m effective depth including excavation in hard / dense soil, foundation in PCC 1:3:6, walls of honeycombed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of 200 mm thiick PCC Solid Block Masonry PCC (1:3:6) in CM (1:6), RCC cover slab in M-25, interconnecting pipes of RCC complete filled with brick bats complete all as specified and directed.and shown on drawing No TD -309 sheet 1/4 to 4/4.
59Total amount of SCHEDULE 'A' PART - VII A(SECURITY WALL, FENCING AND GATES ) (For details see Sch 'A' in PDF folder)
60SCHEDULE 'A' PART - VII B(SECURITY WALL, FENCING AND GATES )
61S & F of Galvanised steel wire concertina coil of 600 mm dia hot dip galvanised. High tensile core wire 2.50 mm , STR- 165 KG/SQMM , 0.50 mm thick with BARB LXW of 22 x 15 mm, spacing 34mm & coated with zink 230 GSM/SQM having 56 loops with 3 clips per loop and giving a coverage of not exceeding 6 m per coil confirming to latest is code and blade spacing 100mm fixe in angle iron complete all as specified & directed.
62Blank
63Total amount of SCHEDULE 'A' PART - VIII(AREA DRAINAGE ) (For details see Sch 'A' in PDF folder)
64Total amount of SCHEDULE 'A' PART - IX(LIGHTENING PROTECTION) (For details see Sch 'A' in PDF folder)
65SCHEDULE 'A' PART - X(AIR CONDITIONING & REFRIGERATION )
66Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp. complete all as specified and directed. all as specified and directed
67Supply, install testing and commissioning all weather Inverter Split Air Conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated for cooling with intelligent heating, High Ambient Cooling, active Dehumidifier, Anti Microbial Air Filteration, 100% Copper, Instant Cooling, Sleep mode, 4-speed fan function, self Diagnosis complete all as specified and directed. all as specified and directed
68Supply, install testing and commissioning Refrigerator, convertible double door with smart inverter compressor, multi air flow, auto smart connect, toughened glass, electric driven (Single Phase), Capacity 240 Litres, BEE 5 Star rated, complete all as specified and directed. all as specified and directed
69Supply, install testing and commissioning water cooler electric driver single phase 230V, sinsitu puf insulation, cfc free refrigernt, having energy efficient hermitically sealed reciprocation type compressor, RO & UV purifier, Cooling capacity 40 Ltrs per hour and water storage copacity 80 Liters, all stainless steel body having two taps complete all as specified and as directed.
70Supply, install testing and commissioning Deep Freezer hard toughened glass top, gross capacity 315/320 liter having double door electric driver single phase 230V, temperture range -24 degree C to +8 degree C, refrigerant R290, inner cabiet made of PP Liner, PUF thickness 60mm complete all as specified and as directed.
71Supply, install tensting and commissioing voltage stabilizer for automatic operation, single phase nautrally air cooled indoor type & designed for input variation between 130V to 300V with output stabilized at 230V with accuracy of + 2.5% and of capacity 4 KVA etc complete all as specified and directed. all as specified and directed. Make : V Guard, bluestar/Servo
72Total amount of SCHEDULE 'A' PART - XI A(EXTERNAL WATER SUPPLY ) (For details see Sch 'A' in PDF folder)
73SCHEDULE 'A' PART - XI B(EXTERNAL WATER SUPPLY )
74Cutting cast iron pipes in position for insertion of new tees, branches, etc.(inclusive of earth work, CI specials, tpt and labour charges etc) complete all as specified and directed at site by Engr-in-Charge
75Construction of new valve pit brick masonry including dismantling existing unsv valve pit complete with mild steel sheet cover 3 mm thick and angle iron frame of size 40 x 40 x 6 mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and including locking arrangement with lock and lifting handle all as specified and shown on drawing brick work of inner surface of pit shall be plaster of cement mortar 1:4 complete all as specified and shown on drawing of size 950 mm x 950 mm x 950 mm (Internal dimension)
76Total amount of SCHEDULE 'A' PART - XII A(EXTERNAL ELECTRIC SUPPLY) (For details see Sch 'A' in PDF folder)
77SCHEDULE 'A' PART - XII B(EXTERNAL ELECTRIC SUPPLY )
78M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cable in trenches complete all as specified & directed. Note- Punned thickness of sand will be measured (18 cm) and paid.
79Supply , laying, jointing & testing of XLPE (XLPE cable confirming to IS 7098 Part I) insulated ,armoured heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 150 Sqmm 3.5 core complete all as specified and directed.Note: (i) Cable shall be directly procured from the manufacturer(ii) The end termination joint shall be measured and paid separately under respective items.(iii) Excavation, earth work, sand cushioning and cable cover protection will be measured and paid separately under respective items.
80Supply , laying, jointing & testing of XLPE (XLPE cable confirming to IS 7098 Part I) insulated ,armoured heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 120 Sqmm 3.5 core complete all as specified and directed.Note: (i) Cable shall be directly procured from the manufacturer(ii) The end termination joint shall be measured and paid separately under respective items.(iii) Excavation, earth work, sand cushioning and cable cover protection will be measured and paid separately under respective items.
81Supply , laying, jointing & testing of XLPE (XLPE cable confirming to IS 7098 Part I) insulated ,armoured heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 50 Sqmm 3.5 core complete all as specified and directed.Note: (i) Cable shall be directly procured from the manufacturer(ii) The end termination joint shall be measured and paid separately under respective items.(iii) Excavation, earth work, sand cushioning and cable cover protection will be measured and paid separately under respective items.
82Supply , laying, jointing & testing of XLPE (XLPE cable confirming to IS 7098 Part I) insulated ,armoured heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 35 Sqmm 3.5 core complete all as specified and directed.Note: (i) Cable shall be directly procured from the manufacturer(ii) The end termination joint shall be measured and paid separately under respective items.(iii) Excavation, earth work, sand cushioning and cable cover protection will be measured and paid separately under respective items.
83Supply , laying, jointing & testing of XLPE (XLPE cable confirming to IS 7098 Part I) insulated ,armoured heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 25 Sqmm 4 core complete all as specified and directed.Note: (i) Cable shall be directly procured from the manufacturer(ii) The end termination joint shall be measured and paid separately under respective items.(iii) Excavation, earth work, sand cushioning and cable cover protection will be measured and paid separately under respective items.
84Supply , laying, jointing & testing of XLPE (XLPE cable confirming to IS 7098 Part I) insulated ,armoured heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 16 Sqmm 4 core complete all as specified and directed.Note: (i) Cable shall be directly procured from the manufacturer(ii) The end termination joint shall be measured and paid separately under respective items.(iii) Excavation, earth work, sand cushioning and cable cover protection will be measured and paid separately under respective items.
85Supply, installing, erecting, commissioning and testing new factory made LT panel board, 415 Volts, 3 Phase & 4wire system, cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley protected with bakelite sheet between bus bar & cable alley with front side shutters with locking arrangement, including TPN Aluminium bus bar insulated with colour coaded heat shrinkable sleeve of rating not less then 1.5 times the rated capacity of the incomer MCCB and bus bar chamber covered both side using bakelite sheet partition and wire mesh to the back side of cable alley for the protection purpose . All type Test Certificates and Design varification with switch geares (MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test at 65 KA, should be submitted by the contractor before executing the job. The TPN bus bar shall be mounted on F class insulators with intervals not more then 500 mm.
86All interconnections between the main bus bar as well as incoming/outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less then 1.5 times rated capacity of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 2.5 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm properly welded with 45 CM long 04 legs of angle iron 50x50x6 mm using 3.15 mm thick CRCA sheet corners to all legs and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of Aluminum lugs and suitable size of chrome plated brass double compression glands provided for incoming and out-going cables comprising the following :- Make of ACB/ MCCB/MCB/Change over switch: L&T/ABB/LEGRAND/SCHNIEDER/SIEMENS
87INCOMING :- (a) Supply and fix 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 36 KA with Thermal megnatic relay adjustable type – 01 Nos (Incoming)OUTGOING :- (b) Supply and fix 4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity 16 KA with Thermal megnatic relay adjustable type – 03 Nos (Main Fire Station, MT area and one for future load)(c) Supply and fix MCB 4 pole 40 AMP, 10 KA C- curve , 50 Hz, 415 V – 03 Nos (MI Room, Drying/Ironing room, + 1 for future load)(d) Supply and fix MCB SPN 40 Amp, 10 KA C - curve 50 Hz, 230 V – 03 Nos (MT/POL Store, Veh waiting area,+3 for future load)(e) Digital Voltmeter with built in selector switch 0-500Volts -1No(f) Digital Ammeter with built in selector switch 0-200 amps with suitable CTs -1 No(g) LED Indicated Lamp (R,Y,B) one Set-01Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate.(ii) Internal power and control wiring with suitable size PVC insulated multistranded copper wire.
88Supply, installing, erecting, commissioning and testing new factory made LT panel board, 415 Volts, 3 Phase & 4wire system, cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley protected with bakelite sheet between bus bar & cable alley with front side shutters with locking arrangement, including TPN Aluminium bus bar insulated with colour coaded heat shrinkable sleeve of rating not less then 1.5 times the rated capacity of the incomer MCCB and bus bar chamber covered both side using bakelite sheet partition and wire mesh to the back side of cable alley for the protection purpose . All type Test Certificates and Design varification with switch geares (MCCB) as per confirming to IS/ IEC: 61439/2011 Part-1 and part -2 with short circuit test at 65 KA, should be submitted by the contractor before executing the job. The TPN bus bar shall be mounted on F class insulators with intervals not more then 500 mm.
89All interconnections between the main bus bar as well as incoming/outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less then 1.5 times rated capacity of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 2.5 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm properly welded with 45 CM long 04 legs of angle iron 50x50x6 mm using 3.15 mm thick CRCA sheet corners to all legs and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of Aluminum lugs and suitable size of chrome plated brass double compression glands provided for incoming and out-going cables comprising the following :- Make of ACB/ MCCB/MCB/Change over switch: L&T/ABB/LEGRAND/SCHNIEDER/SIEMENS
90INCOMING :- (a) Supply and fix 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA with Thermal megnatic relay adjustable type – 01 Nos (Incoming)OUTGOING :- (b) Supply and fix 4 Pole MCCB 32/40 Amp, 50 Hz, 415 V with rupturing capacity 25 KA with Thermal megnatic relay adjustable type – 02 Nos (Amn Lab, +1 for future load)(c) Supply and fix MCB SPN 40 Amp, 10 KA C- Curve, 50 Hz, 230 V – 03 Nos (URPs-02, +1 for future load)(d) Digital Voltmeter with built in selector switch 0-500Volts -1No(e) Digital Ammeter with built in selector switch 0-200 amps with suitable CTs -1 No(f) LED Indicated Lamp (R,Y,B) one Set-01Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate.(ii) Internal power and control wiring with suitable size PVC insulated multistranded copper wire.
91M & L Cable route indicator, duly engraved with 'LT CABLE 1100 VOLT' on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 50 x 6 mm, welded/riveted on back side of plate, fixed and grounted in position with PCC type C-1, block of suitable size complete.
92M & L for installation of Busbar Chamber maSuitable size (CPRI approved) out door type dust proof, vermin proof with IP 56 protection made out of CRCA sheet 3.15 mm thick powder coated having provision for front opening door with hinges including locking arrangements including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, complete with Copper bus bar capacity 250 Amps 04 Nos .
93Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection inclusing GI Pipe 40 mm medium grade 0.75 mtr long with mounting bracket 25 x 6 flat , iron bolt, nut and washers of suitable size complete.
94Supply and fixing Junction box with aluminium bus bar suitable for 3 phase & Neutral , 04 Nos, (RYBN) wire of capacity 100 Amps and MCB 0.5 to 6 amps SPN complete with fixing clamps etc. .
95Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 3x1.5 Sqmm 1100 Volt , draw through LT steel tubular poles for connection to street light from junction box as directed by Engr- in- Charge.
96Supply and Fix integral LED security light luminaire 100 W LED 230 volts made of pressure die cast aluminum housing powder coated with high power SMD LEDs lens & toughened glass IP-66, luminaire efficacy 110 lumens per watt, secondary optics for better light distribution, having two Nos potted driver (OEM) (one inbuilt and one spare potted driver) 4kv internal + 10kv SPD, THD<10%, pf>0.95, including taking down old unserviceable light fittings any type/ wattage from the bracket of pole or any other place not more than 8.00 metres height from ground level and depositing to MES store yard complete all as specified and as directed.Make:-Praze-F140LWHNBA5TGSD of Bajaj, Centura Neo LED flood light100w 6500k IP-66 of Havells, LFSMP-100-C-HL of Orient Electric.
97Supply and fixing post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.
98Earthing complete with copper earth plate electrode 60cm×60cm.× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper strip 20mmx3mm earth lead strip dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified.
99Earthing complete with galvanised steel earthplate electrode 60cmx60cm.x6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edgeof the plate not less than 1.5 metres belownormal ground level, connected to galvanisedusing galvanised iron strip 25×4mm as earthinglead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part I 2006connected to earthing test point, 40 mm bore medium grade GI watering pipe, 40 mm borelight grade GI protection pipe, PCC chamber with RCC cover, funnel with wire mesh etc including necessary test on completion all as specified and as directed.
100Supply & fixing GI Pipe light grade 40 mm dia, ISI marked, of required length for protection of cables complete including necessary MS clamps, nuts, bolts and washers etc complete allas specified and directed.
101Supply and fixing galvanised iron strip 25x4mm all as specified and directe
102Supply and fixing single pointed copper air termination rod 12mm dia, 300mm long fixed on 40mm dia 1.5 mtr long G I pipe medium grade for air termination rod including providing GI clamps, porelain insulator nut bolts asher etc. Bottom of the GI pipe welded at center with 100 mm MS plate 4mm thick and embeded on roof using PCC 1:4:6 type D2 of size 300x300x400mm and fixing of roof conductor with air termination road complete all as specified and directed,
103Total amount of SCHEDULE 'A' PART - XIII(RETAINING WALL AND PROTECTIVE WORK) (For details see Sch 'A' in PDF folder)
104Note : Tenderers may note that amount of credit Rs 20,00,000.00 will be deducted from the total amount arrived, at the time of Acceptance of contract. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56120539
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 90.60 Crore
LAST DATE 28-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Storage Sheds And Ancillary Buildings At Munakot (Phase-Ii).
Basic Detail
Tender No CEBZ/PGH/T-16 OF 2025-26
Bidding Type Tender
Location
City Pithoragarh
State Uttarakhand
Key Dates
Publish Date 23 Jun 2026
Submission Date 28 Jul 2026
Open Date 04 Aug 2026
Finance
Tender Value 90.60 Crore
Tender Fee 3000
EMD 15 Lakhs
Exemption Available
Document List
9aa410d8-23d8-4697-9914-117a01a98106.html
BOQ_866793.xls
drawings.pdf
tender.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 24 days
Aug 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 31 days

Tender Documents

Download All (ZIP) ↓
html

9aa410d8-23d8-4697-9914-117a01a98106.html

xls

BOQ_866793.xls

pdf

drawings.pdf

pdf

tender.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail