| 1 | Demolition of plain cement concrete (Un reinforced) of any description in any position and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000m complete all as specified and directed. |
| 2 | Demolition of stone/brick masonry built in cement mortar incl quoins, arches, etc but exceeding ashlar facing dressed stone Work etc complete all as specified and directed. |
| 3 | M&L for Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius in cement mortar 1:6, complete all as specified and directed. |
| 4 | M&L for PCC 1:2:4 type B-1, (using 20mm graded aggregate) as in grouting of angle posts, pillars ,coping, plinth courses,parapets and raillings etc including necessary form work complete all as specified and directed. |
| 5 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed. |
| 6 | Description all as per item Srl No. 5.00 here in before but except stone complete all as specifeid and directed. |
| 7 | M&L for raised pointing to Random Rubble or Polygonal rubble brought upto course masonary in CM 1:4 complete as specified and directed. |
| 8 | Taking down cement plaster on brick or concrete surfaces including raking out joints, hacking for key scrubbing down with water complete all as specified and directed. |
| 9 | M&L for Rendering 15mm thick in CM (1:4) on fair faces of brick masonry/ concrete surface on wall and finishing the surfaces even and smooth without using extra cement, complete all as specified and directed. |
| 10 | M&L for rendering15 mm thick in cement mortar 1:6 finishing on brick or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed. |
| 11 | M&L for 100 mm thick PCC (1:2:4) type B2 (using 40 mm graded aggregate) as in hard standing / pavement/ramp/floor finsihed even an smooth without using extra cement etc. laid in alternate panels and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000m complete all as specified and directed. |
| 12 | M&L for 75 mm thick, PCC 1:3:6 type C-2 as in plinth protection finished even and smooth without using extra cement complete all as specified and directed. |
| 13 | Dismantling structural steel work including doors, gates,grills but excluding framed truss etc complete all as specified and directed. |
| 14 | S&F framed work such as grills, gratings etc, with ends of bars, shouldered, end or riveted or forged into spikes framed gaured bars barrel iron doors ladders, framed blausters walk ways,raillings,framed water tanks and similar works confirming to Fe 290 Gde-E-165 complete all as specified and directed. |
| 15 | S&F framed work as in doors or gates of angle or other section with gusset plate, rails braces etc, complee drilling for fixing of steel sheeting,hanging, fastening and fixing complete all as specified and directed. |
| 16 | M&L for 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded aggregate ) as in sub for receiving floor finishes etc. complete all as specified and directed. |
| 17 | M&L for chequerd cement concrete tiles glossy finished 30cm x30cmx25mm th with grey cement and pigment , set , jointed and pointed in neat cement slurry in floors laid over 15 mm thic screeed bed in cm 1:6 and including dismantling of tiling including cement mortar bedding (but not backing), removing debrish and rubbish off the premises complete all as specified and directed. |
| 18 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 19 | Preparation of new plastered surfaces of walls and concrete work and applying two coats of cement based paint over a coat of Primer complete all as specified and directed. |
| 20 | M&L for Preparation old plastered or unplastered surfaces of walls and concrete work and applying one coat of cement based paint complete all as specified and directed. |
| 21 | Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 22 | Preparation of old steel surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint . |
| 23 | Taking up or down steel tubing of 15mm bore and connections including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 24 | S&F CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on wall/ceiling or laying in floors 16mm outer dia including all fittings like elbow, tees, sockets, union, nipple, adaptor etc complete all as specified and directed by Engr-in-charge. |
| 25 | Taking up or down steel tubing of 20mm bore and connections including cleaning for re-fixing or removal to store complete all as specified and directed. |
| 26 | S&F CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on wall/ceiling or laying in floors 20mm outer dia including all fittings like elbow, tees, sockets, union, nipple, adaptor etc complete all as specified and directed by Engr-in-charge. |
| 27 | M&L for cutting chases, pinning in making good to facing where required and pointed in CM 1:3 to ends or edge of landing, steps cills, sunshade, shelves etc and cutting chases for concealed water tubing in stone concrete block or slab walls etc and making good cutting n exc 10 cm girth complete all as specified and directed. |
| 28 | Dismantling water storage tanks of any description,exc 250 & n.exc 500 litres capacity and removing from site complete all as specified. |
| 29 | Dismantling water storage tanks of any description,exc 500 & n.exc 1000 litres capacity and removing from site complete all as specified. |
| 30 | S&F 500 litre capacity rotational moulded polyethylene water storage tank (cylindrical vertical double layered with closed top) duly provided with necessary fittings/ fixtures for connecting inlet, outlet, washout and overflow pipes; hoisted and fixed in position incl dismantling PVC water sotrage tanks of capacity more than 250 to 500 litres capacity complete all as specified and directed. |
| 31 | S&F 1000 litre capacity rotational moulded polyethylene water storage tank (cylindrical vertical double layered with closed top) duly provided with necessary fittings/ fixtures for connecting inlet, outlet, washout and overflow pipes; hoisted and fixed in positionincl dismantling PVC water sotrage tanks of capacity more than 500 to 1000 litres capacity complete all as specified and directed. |
| 32 | S&F in repair PVC valveless syphonic action type low level flushing cistern 10ltr capacity white with all internal fittings and handles knob/push including brackets PVC connection 45cm long including nut and PVC washer at both ends with brass chromium plated coupling 32mm bore including 32mm bore PVC long bend flush pipe 90cm long complete all as specified and directed. |
| 33 | S&F in repair Vitreous China wash down water closet (pedestal pattern), White/coloured including traps, connection to drain or outgoing pipe, flushing pipe, anti-syphonage pipe complete including fittings, PVC coloured seat cover and chromium plated jet including PVC connection, fixed complete including demolition of old unservicable WC and provision of plain cement concrete M-15, type B-I, using 20mm graded crushed stone aggregate, fixed in repairs complete all as specified and directed. |
| 34 | S&F in repair Vitreous Chinaware squatting pan, ‘Orrisa pattern’ size 580 mm x 440 mm, crystal white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, integral foot rest with provision of plain cement concrete M-15, type B-I using 20 mm graded crushed stone aggregate complete all as specified, incl making connections to trap and to flush pipe, etc and making good to floors to match existing, in repair, complete all as specified and directed. |
| 35 | S&F in repairs vitreous china,white, wash hand basin, flat back size 550x400mm 'including MS brackets including cutting for and pinning in, including waste fitting , brass, chromium plated with long screw shanks and fly nuts, flange end bedded in red lead cement and other end fixed, PVC connection and 15mm size with CP brass coupling nuts of length 450mm, trap, grating and union for discharge pipe, chain and plug and porcelain stoper and all accessories fixed in repair complete all as specified and directed. |
| 36 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 37 | S&F in repair 600 x 450 mm bevelled edges mirror 5 mm thick of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated screw and cup washers, complete all as specified and directed. |
| 38 | S&F in repair wall mixture for mixing (Hot and Cold) 15mm bore chromium plated cast copper alloy with capstan head screwed for iron pipe fixed complete all as specified and directed |
| 39 | S&F in repair sink mixture for mixing (Hot and Cold) 15mm bore chromium plated cast copper alloy with capstan head screwed for iron pipe fixed complete all as specified and directed. |
| 40 | S&F in repair Brass CP central hole wash basin mixer for hot & cold for 15mm dia complete fixed to connection complete all as specified and directed. |
| 41 | M&L in repair Harrison rails / Curtain rails, anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed. |
| 42 | S&F in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete. |
| 43 | S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 44 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs,weather boardings, plywood including cover fillets etc complete all as specified and directed. |
| 45 | S&F solid PVC wall panelling decorative type consisting of 5 mm th plain colour PVC pre-laminated sheet inclusive of solvent cement and and fixing at site on PVC frame/wooden frame as per specification and drawing complete all as specified and directed. |
| 46 | S&F 5 mm thick PVC sheet fillets of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing |
| 47 | Demolition of reinforced cement concrete of any description (reinforcement cut as reqd to facilitate demolition) complete all as specified and directed. |
| 48 | Taking down cement plaster on brick or concrete surfaces including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed. |
| 49 | M&L for PCC 1:2:4 type B-2, (using 40mm graded aggregate) as in surface channel and drains complete all as specified and directed. |
| 50 | M& for RCC 1:2:4(Nominal Mix) using 12.5mm graded crushed stone aggregate as in slab supported on walls, beams and column in floors, roof landings, balconies, canopies, deck slabs, culverets supported on walls etc complete all as specified and directed. |
| 51 | Form work to edges of concrete flats, breaks in floors, opening in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work all exceeding 20 cm wide complete all as specified and directed. |
| 52 | Form work to edges of concrete flats, breaks in floors, opening in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work all exceeding 10 cm but n exc 20cm wide complete all as specified and directed. |
| 53 | Form work to soffits of suspended slab such as roof slabs, floor slabs, landing and similar work not exceeding 200mm thick complete all as specified and directed. |
| 54 | M&L for MS TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for columns, hooking end and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 55 | M&L for MS TMT bars 5 mm dia and over upto and including 10 mm d cut to length bent ta in stirrups, spacer and binders etc complete all as specified and directed. |
| 56 | M&L Site clearance including clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30cm grith and removing rubbish outside the periphery of the area under clearance complete all as specified & directed by Engineer-in-charge. |
| 57 | Dismantling wrought iron or mild steel work of any description as in angle iron not otherwise provded for etc complete. |
| 58 | S&F angle iron for posts, struts in fencing including cutting tops, to shape as required, drilling holes, notching for wire, including welding etc, confirming to Fe-290 Gde, E-165 complete all as specified and directed. |
| 59 | S&F in repairs for galvanished, 2 strand , steel barbed wire, 2.24 mm dia barbed with 2 mm dia barbs, 75 mm spacing and straining and fixing to any type of standrad rails and straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire complete. |
| 60 | Dismantling fencing wire mesh, any type complete all as specified and directed. |
| 61 | S&F 4mm dia galvanised steel wire, 50 x 50mm / 75x75mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling and fixing to any type of standrad rails and straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire complete all as specified and directed. |
| 62 | M&L for PCC 25mm thick 1:2:4 type B1 (using 12.5mm graded crushed stone aggregates) as in sub flooring , complete all specified and directed. |
| 63 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all specified and directed. |
| 64 | M&L coloured/printed Glazed Vitrified ceramic tiles 9-10 mm thick area of each tiles exc 0.42 sqm but not exc 1.00 sqm, laid in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement complete all as specified and directed by Engineer-in-Charge. |
| 65 | Description all as per item Srl No. 64.00 here in before but on vertical surfaces such as skirting incl rendering in cement mortar 1:3 rough finish to receive the tiles complete all as specified and directed. |
| 66 | M&L 400X400mm tiles 10-15mm thick Parking tile in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar (1:4) laying floor finish complete all as specified and directed. |
| 67 | Description all as per item Srl No. 66.00 here in before but on vertical surfaces such as skirting incl rendering in cement mortar 1:3 rough finish to receive the tiles complete all as specified and directed. |
| 68 | M&L for Non skid ceramic coloured joint free tiles 7 to 8mm thick (square/ rectangular), area of each tiles exceeding 0.06 sqm but n exc 0.11 sqm, in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles,laid over and including cement screed bed 15 mm thick in cement mortar (1:6) laying floor finish complete all as specified and directed. |
| 69 | M&L for glazed coloured ceramic tiles, first quality (or approved class, colour and design/shade) of 350x 250x 7 mm/ 450X350X7mm/450x300x7mm thick in vertical surfaces, as in dado/skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with coloured tiles, over and including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles complete all as specified and directed. |
| 70 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid beded & pointed any type of mortar complete all as specified and directed. |
| 71 | M&L for 18-20mm thick granite stone (slab) of any colour/type, (table rubbed and polished) work as in floors/ vertical surfaces, cooking platforms and like, set in neat cement including pointing in white cement with admixture of pigment to match with shade of granite, complete laid over and including 15mm thick screed bed in cement mortor (1:6) laid and jointed with gray cement slurry mixed with pigment, , complete all specified and directed. |
| 72 | M&L for 18-20mm thick pre-polished granite slabs, machine cut, in vertical/horizontal surfaces including over 15mm cement plaster in (1:4) and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of the granite stone including grinding and polishing complete all as specified and directed. |
| 73 | M&L for Rounding to edges of stone slabs one edge, such as in steps,cooking platform, and other similar situations complete all as specified and as directed. |
| 74 | Providing & fixing false ceiling at all heights 12mm with semi perforated micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisturecontent less than 2%, humidity resistance\ of 99%, NRCO.50 to 0.75 as per IS8225:1987, Noncombustible as per BS476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in truehorizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners (Groove type) of size 15 x 32 mm of length 3000mm, cross-T (Groove type) of size 15x 32mm of length 1200mm and secondary intermediate cross-T (Groove type) of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 75 | S&F PVC/WPC Designer Wall Panelling comprising PVC/WPC laminated panels 8–10 mm thick, fire-retardant, ISI marked, having density not less than 1.4 gm/cm³, in approved shade, colour, design and pattern with glossy/matte finish, fixed in interlocked arrangement using tongue-and-groove / click-lock joint system to ensure proper alignment and seamless finish, fixed to GI/MS framework/battens consisting of vertical and horizontal members of approved make and size, securely fixed to wall surface with screws, rawl plugs, dash fasteners, nuts, bolts and necessary accessories complete.Note:The work shall include providing and fixing all corner profiles, edge trims, junction strips, grooves, beads and end caps wherever required, making necessary cut-outs/openings for electrical switches, sockets, conduits, AC pipes, service openings and other fixtures, with all joints truly aligned, edges neatly finished, surface properly cleaned and completed in all respects, complete all as specified and directed by Engr-in-Charge. |
| 76 | Taking down chowkhats or frames but with shutters (without taking off shutters from the frames) exc 1.5 Sqm and n exc 4 Sqm each complete all as specified and directed. |
| 77 | Supply and fixing factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 48x40 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-charge complete all as specified and directed |
| 78 | Supply and fixing factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.10 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-in-Charge. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. (Make: Finesta or equivalent) |
| 79 | S&F 5.5mm thick frosted, on one side Sheet glass, ordinary quality and glazing with oil putty / EPDM gasket in square exc 0.5 sq. m in each pane complete all as specified and directed. |
| 80 | Supply and fixing 5.5mm frosted/acid-etched glass strip of approved size and thickness with DRDO logo sand blasted/laser engraved at top portion, including edge finishing, necessary beading (wooden/aluminium/uPVC as applicable), rubber packing, screws, sealant, and fixing in panels/partitions/doors complete, all as specified and as directed. |
| 81 | Dismantling plain or corrugated fibre glass reinforced translucent sheeting, any gauge, thickness complete all as specified and directed. |
| 82 | S&F Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete, all as specified and as directed. |
| 83 | Taking up/down plants or vegetation growth from wall upto roof level by means of cutting hole into brick wall and making good the surface of dismantled portion (not exc 150 sq cm superfical area and not exc one brick depth) using brick bats /aggregate and plastering in cement mortar (1:4) to distrubed portion and applying two coats of cement base paint / weather coat to match the existing surface upto forth floor complete all as directed by Engineer -in-charge. Please Enable Macros to View BoQ information |
| 84 | Taking up/down plants or vegetation growth from wall upto roof level by means of cutting hole into brick wall and making good the surface of dismantled portion (not exc 150 sq cm superfical area and not exc one brick depth) using brick bats /aggregate and plastering in cement mortar (1:4) to distrubed portion and applying two coats of cement base paint / weather coat to match the existing surface upto forth floor complete all as directed by Engineer -in-charge. Please Enable Macros to View BoQ information |