| Sl. No. | Item Description |
| 1 | 1. SITE DEVELOPMENT ALONG WITH LANDSCAPING WORKClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 2 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m. |
| 3 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 4 | Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. |
| 5 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) |
| 6 | Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m.lead complete (Cattle manure measured in stacks will reduced by 8% for Payment). |
| 7 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)2.14.1 Holes 1.2 m dia and 1.2 m deep |
| 8 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) 2.14.2 Holes 90 cm dia, and 90 cm deep |
| 9 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) 2.14.3 Holes 60 cm dia, and 60 cm deep |
| 10 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)2.14.4 Holes 45 cm dia, and 45 cm deep. |
| 11 | Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 12 | Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. |
| 13 | Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 14 | Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-in-charge. |
| 15 | Providing and stacking of Mangifera indica (Mango-grafted ) of height 60-75 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. |
| 16 | Providing and stacking of Putranjiva roxburghii of height 90-105 cm. in big polybag of size 25 cm as per direction of the officer-in-charge. |
| 17 | Providing and stacking of Thuja compacta of height 75-90 cm., conical shaped, well formed with healthy foliage in earthen pots of size 30 cm as per direction of the officer-in-charge |
| 18 | Providing and Displaying Acalypha Different colour well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size of Earthen Pot/ Plastic Pot bushy as per direction of the officer-in-charge. |
| 19 | Providing and stacking of Murraya exotica of height 45-60 cm. in poly bags of size 15 cm as per direction of the officer-in-charge. |
| 20 | Providing and displaying of Croton Petra having ht. 45 cm & above with 2 to 3 branches, well developed, fresh and healthy leaves in 25 cm size of Earthen pot/Plastic pot. & as per direction of the officer-in-charge. |
| 21 | Providing and stacking of Schefflera green, having 3 to 4 branch, ht. 30 to 45 cm well developed with fresh & healthy in 20 cm size of Earthen Pot/ Plastic Pot as per direction of the officer-in-charge |
| 22 | Providing and stacking of Alternanthera species of height 15 cm to 20 cm, full of branches and foliage in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. |
| 23 | Providing and stacking of Dianella variegated, with 3 to 4 variegated leaves in 20 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge. |
| 24 | Providing and stacking of Chlorophytum-variegated, full of leafy suckers in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge |
| 25 | Providing and stacking of Portulacaria afra (Jade ) with 5 to 6 branches in 20 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge |
| 26 | Providing and stacking of plant Canna dwarf of height 25 to 30 cm., 2 to 3 suckers in earthen pots of size 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge |
| 27 | Providing and displaying of Spathiphyllum (peace Lilly), having 15 cm to 25 cm ht. blooming stag with fresh & healthy foliage well developed in 15 cm of Earthen pot/plastic pot & as per direction of the officer-in-charge. |
| 28 | Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. |
| 29 | Providing and stacking of Clerodendrum thomsoniae of height 30 cm.to 45 cm in 20 cm size of poly bag & as per direction of the officer-in-charge |
| 30 | Providing and stacking of Euphorbia milli hybrid variety, having ht. 30 cm to 45 cm with multi branch, full bloom, fresh and healthy leaves in 30 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.. |
| 31 | Providing and displaying of Areca Palm having ht. 2.40 m to 2.70 m with 12 to 14 suckers, well developed, fresh and healthy with lush green foliage in 35 cm size of Bucket type cement pots & as per direction of the officer-in-charge. |
| 32 | Providing and stacking of Foxtail palm of ht. 180-210 cm bottom girth 25 30 cm well developed in big size HDPE bags as per direction of the officer-in-charge. |
| 33 | Providing and Displaying Phoenix roebelenii palm well developed having 20 to 25 fresh & healthy leaves 90 to 105 cm ht. in 30 cm Cement Pot as per direction of the officer-in-charge. |
| 34 | Desilting of Lake/river etc. by using contractor's Amphibian dredger machine, having capacity of the dredger of minimum 67.2 cum per hour in solid state excluding isolated bolder and hard rock for distance of 600.0 mtr. from lake/river bank and de-silted soil to be dumped at suitable place for making road, Islands etc. as per direction of the Engineer-in-charge. |
| 35 | Providing, fabricating, supplying and installing designer public art installation (“Euphoria Art”), comprising a group of organically shaped, tree-inspired sculptural elements with multiple flared canopy forms, executed in custom-fabricated structural steel framework with curved tubular / plate members, ribs and branches, duly designed for wind and structural stability, complete with FRP / aluminium / MS skin panels finished in approved vibrant exterior-grade colour scheme with high-performance polyurethane / fluoropolymer paint. The installation shall include integrated decorative fins / wire elements at top, concealed connections, smooth edge detailing, internal stiffeners, access provisions for maintenance, and anchoring over RCC pedestal / foundation with base plates, anchor bolts and non-shrink grouting. Item includes surface preparation, anti-corrosive treatment (hot-dip galvanizing / epoxy system), shop fabrication, transportation, erection with cranes, alignment, levelling, touch-up painting, protection during execution, coordination with landscaping and walkway works, and all materials, labour, tools, equipment and incidentals, complete in all respects as per approved drawings, structural design, mock-up approval and directions of Engineer-in-Charge. |
| 36 | Providing and constructing a new sluice gate for controlled passage of excess water between connected water bodies, including site clearance, earthwork excavation in foundation, providing PCC bed, RCC M20 for base slab, side walls, piers and abutments with reinforcement steel, centering and shuttering, brick masonry where required, plastering and curing; supplying, fabricating and fixing MS sluice gate shutter and frame with guide channels, rubber sealing, embedded anchor plates and fasteners, including operating arrangement such as spindle, nut, hand wheel and pedestal; providing anti-corrosive treatment with approved primer and synthetic enamel paint to all steel components, backfilling and dressing of ground, and carrying out testing, trial operation and commissioning to ensure smooth and effective discharge of excess water, complete in all respects as per approved drawings, technical specifications and directions of the Engineer-in-Charge. |
| 37 | 2. CONSTRUCTION OF MAIN ENTRY GATEEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 38 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 39 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 40 | Providing and laying dry flat brick flooring in required pattern complete. |
| 41 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 42 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 43 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 44 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 45 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 46 | Centering shuttering including struttings, propping etc. and removal of form work for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 47 | Centering shuttering including struttings, propping etc. and removal of form work for:Columns, Pillars, Piers,Abutments, Post sand Struts with M.S. shutters |
| 48 | Centering shuttering including struttings, propping etc. and removal of form work for:Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 49 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 50 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 51 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 52 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 53 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 54 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 55 | 15mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 56 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
| 57 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade[Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 58 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 59 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 fine sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by theEngineer-in-Charge. |
| 60 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 61 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : Gamair Wood 50 × 20 mm |
| 62 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submissionof Test Certificate issued by the Manufacturer]:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10sqm of approved brand and manufacture. |
| 63 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 64 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high- pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 65 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto1.75 sqm) |
| 66 | Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm) |
| 67 | Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in- Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made Casement window double panels with S.S. friction hinges (300 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window above 0.75 sqm upto 1.50 sqm). |
| 68 | Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) |
| 69 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10sqm of approved brand and manufacture Hot finished seamless type tubes |
| 70 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 fine sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand) and finished neat etc. complete as per direction of Engineer-in-charge. |
| 71 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mmhigh having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern etc. complete as per direction of Engineer-in-charge. and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60 |
| 72 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 73 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:- In grating, frames, guard bar, railing, brackets, gates and similar works, all complete. |
| 74 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submissionof Test Certificate issued by the Manufacturer]: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10sqm of approved brand and manufacture |
| 75 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :White sand stone - Exposed face machine cut and table rubbed with rough backing.40mm thick |
| 76 | Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete : |
| 77 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete : 125 × 65 × 2.12 mm |
| 78 | Providing and fixing ISI marked oxidised M.S.sliding door bolts with nuts and screws etc. complete 300×16 mm |
| 79 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm |
| 80 | Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete. 300 mm weighing not less than 200 gms. |
| 81 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125 x 64 x 1.90 mm |
| 82 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 83 | Providing 40×5 mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30×10×15 cm 1:3:6 mix (1 cement :3 fine sand : 6 graded stone aggregate 20mm nominal size) |
| 84 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm |
| 85 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clampsat 1.00m spacing. This includes jointingof pipes & fittings with one step CPVC solvent cement and testing of joints complete asper direction of Engineer in Charge. Internal work - Exposed on wall15 mm nominal outer dia .Pipes. |
| 86 | 20 mm nominal outer dia .Pipes. |
| 87 | 25 mm nominal outer dia .Pipes |
| 88 | 32 mm nominal outer dia .Pipes |
| 89 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clampsat 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.15 mm nominal outer dia .Pipes |
| 90 | 20 mm nominal outer dia .Pipes. |
| 91 | 25 mm nominal outer dia .Pipes |
| 92 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot&cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling&testing of jointscompleteas per direction of Engineer in Charge. External work15 mm nominal outer dia .Pipes. |
| 93 | 20 mm nominal outer dia .Pipes. |
| 94 | 25 mm nominal outer dia .Pipes. |
| 95 | 32 mm nominal outer dia .Pipes |
| 96 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats complete :15 mm nominal bore |
| 97 | 20 mm nominal bore |
| 98 | Providing and fixing gunmetal gate valve with C.I. wheel of approved quality (screwed end):32 mm nominal bore |
| 99 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi Rigid PVC waste pipe for sink and wash basin 32 mm dia with length not less than 700 mm i/c PVC waste fittingsSemi rigid pipe 40 mm dia |
| 100 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 TypeA including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 101 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592Type-A including jointing with seal ring conforming to IS : 5382 leaving10mm gap for thermal expansionetc. complete as per direction of Engineer-in-charge :Coupler 110 mm |
| 102 | Single pushfit Coupler 110 mm |
| 103 | Single equal tee without door 110x110x110mm |
| 104 | Single equal tee with door 110x110x110mm |
| 105 | Bend 87.5° 110mm |
| 106 | Plain shoe 110mm |
| 107 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 108 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms. |
| 109 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore. |
| 110 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 111 | Providing and Fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm size respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 112 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 113 | Providing and laying cement concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mmnominal size) upto haunches of S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe |
| 114 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard designInside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
| 115 | Constructing soak pit 1.20 x 1.20 x 1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design |
| 116 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,PartI.Payment will be made separetly on the basis of actual height based on relevant I.S.Code.For 20 users |
| 117 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 118 | Chair CELLBELL C62 Folding Study Chair with Cushion and Adjustable Writing Pad for All Age for Work,Product Dimensions:30.5D x 30.5W x 45.7H Centimeters,Base Material: Metal,Height Suitability : 4.5 ft to 5.5 ft,Maximum Weight Recommendation:100 Kilograms |
| 119 | High-comfort pushback chair designed for auditorium seating. Upholstered in durable faux leather (leatherette) with high-density foam and a semi-automatic pushback mechanism. Built on a robust powder-coated metal frame, fixed to the floor for safety and stability. Ideal for auditoriums, seminar halls, conference rooms, and institutional use.Seat Type: Pushback with tilt (manual return),Upholstery: Leatherette (faux leather), stain-resistant,Seat Height: 18\\",Back Height: 36–38\\",Depth: 24–28\\" (including pushback allowance) |
| 120 | 3. CONSTRUCTION OF LEISURE SQUAREEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 121 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 122 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 123 | Providing and laying dry flat brick flooring in required pattern complete. |
| 124 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 125 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 126 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 127 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 128 | Neat cement punning. |
| 129 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 130 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 fine sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.14 mm thick stone slab |
| 131 | Providing and fixing Kota stone in floors over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with ordinary cement slurry including pointingwith ordinary cement mixed with pigment of matching shade, including rubbing and polishing etc. all complete as per direction of Engineer-in-charge.Kota stone slab 25mm thick |
| 132 | Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. |
| 133 | Providing and fixing circular/wavy shaped landscaped seating around existing tree, comprising ergonomically designed curved bench formed with vertical hardwood / treated timber / WPC slats mounted over a mild steel / galvanized steel circular supporting frame, including inner and outer circular seating rings with smooth rounded edges, proper spacing between slats, concealed fasteners, anti-rust treatment to steel members, factory-finished or site-applied weather-resistant exterior wood finish / polish, complete with RCC base / pedestal (if required), anchoring, alignment, levelling and making good surrounding paving, including all materials, labour, fabrication, transportation, erection, surface treatment, protection and incidentals, complete in all respects as per approved design, drawings and directions of Engineer-in-Charge. |
| 134 | 4. CONSTRUCTION OF STAFF QUARTEREarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 135 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 136 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 137 | Providing and laying dry flat brick flooring in required pattern complete. |
| 138 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 139 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 140 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 141 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 142 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 143 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 144 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 145 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 146 | Weather shade, Chajjas, corbels etc., including edges. |
| 147 | Columns, Pillars, Piers,Abutments, Post sand Struts with M.S. shutters |
| 148 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 149 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 150 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 151 | Neat cement punning. |
| 152 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 153 | 15mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 154 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
| 155 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 156 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats) over and including waterthinnable priming coat with cement primer. |
| 157 | Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622- 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-chargeSoluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid) |
| 158 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid)Size of tile 1200 mm x 600 mm |
| 159 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/ system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 160 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 161 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :Gamair Wood 50 × 20 mm |
| 162 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture. |
| 163 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high- pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 164 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 165 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm) |
| 166 | Fixed window / ventilator made of (small series) frame47 x 50 mm & mullion 47 x 6 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead ofappropriate dimension. (Area upto 0.75 sqm.) |
| 167 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 168 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 169 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete :125 × 65 × 2.12 mm |
| 170 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125 x 64 x 1.90 mm |
| 171 | Providing and fixing ISI marked oxidised M.S.sliding door bolts with nuts and screws etc. complete 300×16 mm |
| 172 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :250x10 mm |
| 173 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 174 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm |
| 175 | Providing 40×5 mm flat iron hold fast 40cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30×10×15 cm 1:3:6 mix (1 cement :3 fine sand : 6 graded stone aggregate 20mm nominal size) |
| 176 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm at 100 mm centre to centre and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia. steel pulleys & with riveted bolts, nuts, locking arrangement, stoppers, handles, hold fast/anchor bolt including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approvedsteel primer etc. complete as required. |
| 177 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clampsat 1.00m spacing. This includes jointingof pipes & fittings with one step CPVC solvent cement and testing of joints complete asper direction of Engineer in Charge. Internal work - Exposed on wall15 mm nominal outer dia .Pipes |
| 178 | 20 mm nominal outer dia .Pipes |
| 179 | 25mm nominal outer dia .Pipes |
| 180 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clampsat 1.00m spacing. This includes jointingof pipes & fittings with one step CPVC solvent cement and testing of joints complete asper direction of Engineer in Charge. Internal work - Exposed on wall32 mm nominal outer dia .Pipes |
| 181 | 40 mm nominal outer dia .Pipes |
| 182 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clampsat 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.15 mm nominal outer dia .Pipes |
| 183 | 20 mm nominal outer dia .Pipes. |
| 184 | 25 mm nominal outer dia .Pipes |
| 185 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot&cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling&testing of jointscompleteas per direction of Engineer in Charge. External work15 mm nominal outer dia .Pipes. |
| 186 | 20 mm nominal outer dia .Pipes. |
| 187 | 25 mm nominal outer dia .Pipes. |
| 188 | 32 mm nominal outer dia .Pipes |
| 189 | 40 mm nominal outer dia .Pipes |
| 190 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats complete :15 mm nominal bore |
| 191 | 20 mm nominal bore |
| 192 | 25 mm nominal bore |
| 193 | Providing and fixing gunmetal gate valve with C.I. wheel of approved quality (screwed end):32 mm nominal bore |
| 194 | 40 mm nominal bore |
| 195 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi Rigid PVC waste pipe for sink and wash basin 32 mm dia with length not less than 700 mm i/c PVC waste fittingsSemi rigid pipe 40 mm dia |
| 196 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 TypeA including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 197 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592Type-A including jointing with seal ring conforming to IS : 5382 leaving10mm gap for thermal expansionetc. complete as per direction of Engineer-in-charge :Coupler 110 mm |
| 198 | Single pushfit Coupler 110 mm |
| 199 | Single equal tee without door 110x110x110mm |
| 200 | Single equal tee with door 110x110x110mm |
| 201 | Bend 87.5° 110mm |
| 202 | Plain shoe 110mm |
| 203 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 204 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms. |
| 205 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore. |
| 206 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 207 | Providing and Fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm size respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 208 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 209 | Providing and laying cement concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mmnominal size) upto haunches of S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe |
| 210 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard designInside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
| 211 | Constructing soak pit 1.20 x 1.20 x 1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design |
| 212 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,PartI.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. For 20 users |
| 213 | Providing and fixing PTMT grating of approved quality and colour.125 mm nominal dia with 25 mm waste hole. |
| 214 | Providing and fixing toilet paper holder :C.P. brass |
| 215 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved makeconforming to IS:8931. 15 mm nominal bore. |
| 216 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with6 mm thick hard board backing :Rectangular shape 1500x450 mm |
| 217 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 218 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40 mm dia |
| 219 | 32 mm dia |
| 220 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support fortank. |
| 221 | Chair CELLBELL C62 Folding Study Chair with Cushion and Adjustable Writing Pad for All Age for Work,Product Dimensions:30.5D x 30.5W x 45.7H Centimeters,Base Material: Metal,Height Suitability : 4.5 ft to 5.5 ft,Maximum Weight Recommendation:100 Kilograms |
| 222 | Stylish and functional centre table crafted with a sturdy wooden or engineered wood frame. Features a smooth laminated or veneer top surface with a durable finish, designed to complement modern and classic interiors. Perfect for living rooms, lounges, or office reception areas.Material: Engineered wood / MDF with laminate or veneer finish,Top Surface: Smooth laminated/veneer top (resistant to scratches and stains),Frame & Legs: Solid wood or metal legs (powder coated if metal),Dimensions: Approx. 36\\" L x 24\\" W x 18\\" H (customizable) |
| 223 | Providing and supplying moulded plastic arm chair (Monoblock type) made of virgin polypropylene, heavy-duty quality, with arm rests and slotted back, weather-resistant, UV stabilized, smooth finish, suitable for outdoor/indoor use, complete in all respects, as directed by Engineer-in-Charge. |
| 224 | Providing and supplying foldable table having rectangular moulded plastic (HDPE / polypropylene) top, minimum thickness 18–25 mm, smooth finish with rounded edges, supported on powder-coated mild steel tubular folding legs, with locking arrangement, anti-skid rubber shoes at bottom, strong and durable, suitable for indoor and outdoor use, complete in all respects, as directed by Engineer-in-Charge. |
| 225 | Providing and supplying single bed (cot) made of seasoned hardwood / teak wood / sal wood / rubber wood (as approved), with strong frame, headboard, side rails, legs, proper joinery, smooth finished edges, complete with plywood/wooden slatted base, finished with melamine / PU polish / synthetic enamel, including all materials, labour, polishing, loading, unloading, transportation to site, complete in all respects, as directed by Engineer-in-Charge. |
| 226 | 5. CONSTRUCTION OF CENTRAL FOUNTAIN ISLANDEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 227 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 228 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 229 | Providing and laying dry flat brick flooring in required pattern complete. |
| 230 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 231 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 232 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 233 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 234 | Centering shuttering including struttings, propping etc. and removal of form work for:Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. using shuttering ply |
| 235 | Centering shuttering including struttings, propping etc. and removal of form work for:Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 236 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 237 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 238 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 239 | Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design etc. all complete as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge. |
| 240 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot&cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling&testing of jointscompleteas per direction of Engineer in Charge. External work32 mm nominal outer dia .Pipes |
| 241 | Providing, fabricating and installing a thematic decorative wood-finish boat sculpture (of 7m Length & approx. 8m height) positioned at the center of a circular waterbody, including MS structural framing for boat hull and mast, external cladding with FRP/GRP panels finished in premium wood-grain texture, fabric sail supported on treated timber/steel frame, anti-corrosive coating, anchoring arrangement within pond base, and complete construction of circular water feature with waterproofed RCC basin, smooth internal plaster finish, protective paint, inlet–outlet piping, mini circulation pump, required valves, fittings, edge coping and green-turfed embankment treatment; complete in all respects including design detailing, fabrication, painting, transport, installation, testing of water circulation system, and all incidental works as per direction of Engineer-in-Charge |
| 242 | 6. CONSTRUCTION OF PAVED PATHWAY & INTERNAL PATHWAYExcavation for Structures With dewatering Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out,Ordinary Soil (i) Upto 3 m depth |
| 243 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. All kinds of soil |
| 244 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 245 | Providing and laying dry flat brick flooring in required pattern complete. |
| 246 | Providing concrete for plain/reinforced concrete in open foundations complete including formworkasperdrawings &MoRD technical specifications Clauses 802, 803, 900, 1202 and1203. (including centering, shuttering, staging etc. but excluding reinforcement).II P.C.C grade M 15(i) Nominal mix (1:2.5:5) |
| 247 | Providing and fixing chequered terrazo tiles 22 mm thick with graded marble chips of size upto 6 mm, laid on floors, footpath & courtyard on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and polishing etc. all complete as per direction of Engineer-in-charge. Light shade pigment using white cement |
| 248 | 60 mm thick factory made c.c interlocking paver block of M -30Grade: Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of sand, filling the joints with fine sand etc. all complete as per specification and approval/ direction of the Engineer-in-charge. |
| 249 | Cast in Situ Cement Concrete M 20 Kerb:Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per drawings & MoRT&H technical specifications Clauses 409. A. Using Concrete Mixer |
| 250 | 7. CONSTRUCTION OF Parking Zone Toilet BlockEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 251 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 252 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 253 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 254 | Providing and laying dry flat brick flooring in required pattern complete. |
| 255 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 256 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 257 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 258 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 259 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 260 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 261 | Columns, Pillars, Piers,Abutments, PostsandStrutswith M.S. shutters |
| 262 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 263 | Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 264 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 265 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 266 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 267 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 268 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 269 | Neat cement punning. |
| 270 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 271 | 15mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 272 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
| 273 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture, of required shade and colour complete, as per manufacurer's specification. [Payment shall be made after submission of Test Certificate issued by the Manufacturer] New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 274 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 275 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 276 | Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622- 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-chargeSoluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid) |
| 277 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 fine sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand) and finished neat etc. Complete as per direction of Engineer-in-charge. |
| 278 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 279 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high- pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 280 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :Gamair Wood 50 × 20 mm |
| 281 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 282 | Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead ofappropriate dimension. (Area upto 0.75 sqm.) |
| 283 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 284 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture. |
| 285 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 286 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm |
| 287 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clampsat 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.15 mm nominal outer dia .Pipes |
| 288 | 25 mm nominal outer dia .Pipes |
| 289 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot&cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling&testing of jointscompleteas per direction of Engineer in Charge. External work32 mm nominal outer dia .Pipes |
| 290 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats complete :15 mm nominal bore |
| 291 | 25 mm nominal bore |
| 292 | Providing and fixing gunmetal gate valve with C.I. wheel of approved quality (screwed end):32 mm nominal bore |
| 293 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi Rigid PVC waste pipe for sink and wash basin 32 mm dia with length not less than 700 mm i/c PVC waste fittingsSemi rigid pipe 40 mm dia |
| 294 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 TypeA including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 295 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592Type-A including jointing with seal ring conforming to IS : 5382 leaving10mm gap for thermal expansionetc. complete as per direction of Engineer-in-charge :Coupler 110 mm |
| 296 | Single pushfit Coupler 110 mm |
| 297 | Bend 87.5° 110mm |
| 298 | Plain shoe 110mm |
| 299 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 300 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms. |
| 301 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore. |
| 302 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 303 | Providing and Fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm size respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 304 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 305 | Providing and laying cement concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mmnominal size) upto haunches of S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe |
| 306 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard designInside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
| 307 | Constructing soak pit 1.20 x 1.20 x 1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design |
| 308 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,PartI.Payment will be made separetly on the basis of actual height based on relevant I.S.Code.For 20 users |
| 309 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 310 | 8. CONSTRUCTION 0F TOILET BLOCK (3 nos.)Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 311 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 312 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 313 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 314 | Providing and laying dry flat brick flooring in required pattern complete. |
| 315 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 316 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 317 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 318 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 319 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 320 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 321 | Columns, Pillars, Piers,Abutments, PostsandStrutswith M.S. shutters |
| 322 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 323 | Weather shade, Chajjas, corbels etc., including edges. |
| 324 | Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 325 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 326 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 327 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 328 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 329 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 330 | Neat cement punning. |
| 331 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 332 | 15mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 333 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
| 334 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture, of required shade and colour complete, as per manufacurer's specification. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]New work ( two or more coats) over and including waterthinnable priming coat with cement primer. |
| 335 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 336 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 337 | Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622- 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-chargeSoluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid) |
| 338 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 fine sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand) and finished neat etc. complete as per direction of Engineer-in-charge. |
| 339 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 340 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high- pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 341 | Providing and fixing factory made laminated veneern lumber glazed shutter conforming to IS 14616 and TADS 15:2001 (Part B), using 4mm thick float glasspanes for doors, windows and clerestory windows including ISI marked black enamelled M.S butt hinges with necessary screws as per direction of Engineer-incharge.30 mm thick shutters |
| 342 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :Gamair Wood 50 × 20 mm |
| 343 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 344 | Providing and fixing factory made uPVC white colou fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in- Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) |
| 345 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 346 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture. |
| 347 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 348 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm |
| 349 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clampsat 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.15 mm nominal outer dia .Pipes |
| 350 | 25 mm nominal outer dia .Pipes |
| 351 | 32 mm nominal outer dia .Pipes |
| 352 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats complete :15 mm nominal bore |
| 353 | 25 mm nominal bore |
| 354 | Providing and fixing gunmetal gate valve with C.I. wheel of approved quality (screwed end):32 mm nominal bore |
| 355 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi Rigid PVC waste pipe for sink and wash basin 32 mm dia with length not less than 700 mm i/c PVC waste fittings Semi rigid pipe 40 mm dia |
| 356 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 TypeA including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 357 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592Type-A including jointing with seal ring conforming to IS : 5382 leaving10mm gap for thermal expansionetc. complete as per direction of Engineer-in-charge :Coupler 110 mm |
| 358 | Single pushfit Coupler 110 mm |
| 359 | Bend 87.5° 110mm |
| 360 | Plain shoe 110mm |
| 361 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 362 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms. |
| 363 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore. |
| 364 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 365 | Providing and Fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm size respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 366 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 367 | Providing and laying cement concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mmnominal size) upto haunches of S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe |
| 368 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard designInside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
| 369 | Constructing soak pit 1.20 x 1.20 x 1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design |
| 370 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,PartI.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. For 50 user |
| 371 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 372 | 9. CONSTRUCTION OF TICKET COUNTER (FOR 2 nos.)Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 373 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 374 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 375 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 376 | Providing and laying dry flat brick flooring in required pattern complete. |
| 377 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 378 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 379 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 380 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 381 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 382 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 383 | Columns, Pillars, Piers,Abutments, PostsandStrutswith M.S. shutters |
| 384 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 385 | Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 386 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 387 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 388 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 389 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 390 | Neat cement punning. |
| 391 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 392 | 15mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 393 | 12 mm cement plaster of mix Cement mortar 1:4 (1 cement : 4 fine sand) |
| 394 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture, of required shade and colour complete, as per manufacurer's specification. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]New work ( two or more coats) over and including waterthinnable priming coat with cement primer. |
| 395 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 396 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 397 | Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622- 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-chargeSoluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid) |
| 398 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 fine sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand) and finished neat etc. complete as per direction of Engineer-in-charge. |
| 399 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 400 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass (weight not less than 10ks/Sqm) panes including black enamelled ISI marked MS butt hinges with necessary screws.35 mm thick |
| 401 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :Gamair Wood 50 × 20 mm |
| 402 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 403 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture. |
| 404 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 405 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm |
| 406 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 TypeA including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 407 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592Type-A including jointing with seal ring conforming to IS : 5382 leaving10mm gap for thermal expansionetc. complete as per direction of Engineer-in-charge :Coupler 110 mm |
| 408 | Bend 87.5° 110mm |
| 409 | Providing and laying cement concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mmnominal size) upto haunches of S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe |
| 410 | Supply and placement of moulded plastic chairs made of heavy-duty, virgin polypropylene material, armless type, stackable design, having minimum load-bearing capacity of 100–120 kg, suitable for continuous public use. The chair shall be weather-resistant, UV-stabilized, easy to clean and maintain, with anti-skid legs. The item includes transportation, handling, placement at site in proper alignment, complete as per direction of Engineer-in-Charge. |
| 411 | 10. CONSTRUCTION OF ARTIFACTS(MOAI STATUE)Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 412 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 413 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 414 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 415 | Providing and laying dry flat brick flooring in required pattern complete. |
| 416 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 417 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 418 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 419 | Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 fine sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade etc. all complete as per direction of Engineer-in-charge.8mm thick Rajnagar marble tiles (polished) |
| 420 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 421 | Providing and installing artistic landscape artifacts in the form of abstract / tribal human head sculptures (of Height 6ft), consisting of a group of three (03) freestanding sculptural elements of varying heights, inspired by indigenous / heritage forms, manufactured out of fibre-reinforced polymer (FRP) with integral sculpted facial features, finished in weather-resistant textured exterior coating in approved colour and shade, including internal structural frame (if required), base plates / dowels, and fixing over prepared RCC pedestal / foundation with anchor bolts, grouting, alignment, levelling and making good the surrounding area, complete with all labour, materials, tools, transportation, erection, surface finishing, curing, protection and incidentals, as per approved drawing, design intent and direction of Engineer-in-Charge. |
| 422 | 11. CONSTRUCTION OF FLOATING RESTAURENTDesign, manufacture, supply, assembly and installation of Double HDPE modular floating dock system made from 100% pure virgin High Density Polyethylene (HDPE) by blow-moulding process, UV resistant, chemical resistant and suitable for freshwater bodies. Each module shall be of size 500 mm × 500 mm × 400 mm, square shape with interlocking arrangement through center pin system, lug thickness 22 mm, anti-skid top surface, weight approx. 7.5 kg (±5%), and minimum buoyancy of more than 350 kg per sqm. The item includes supply of all accessories such as center pins, nuts, bolts, washers, interlocking fittings and provision of double-layered jetty arrangement for enhanced stability, complete in all respects as per manufacturer’s specifications, including positioning, alignment and basic testing. |
| 423 | Supply and fixing of WPC (Wood Plastic Composite) decking boards over the HDPE floating dock system, suitable for outdoor and marine environment, water-resistant, termite-proof, anti-skid and UV-stable, including necessary sub-framing, fastening system, clips, screws and finishing complete.The item includes cutting, fixing, edge finishing and alignment to form continuous deck flooring over floating platform, complete as per approved layout and manufacturer’s recommendation. |
| 424 | Supply and fixing of WPC roofing / overhead decking panels including necessary supporting members, fixtures and fasteners, suitable for outdoor exposure and floating structure application, complete in all respects as per approved design and specification. |
| 425 | Providing services for installation, assembly and fixing of HDPE floating modules, WPC decking and associated components, including minor electrical wiring, alignment, adjustments, handling, labour charges and other incidental works required to make the floating platform functional and complete. |
| 426 | Design, fabrication, supply and installation of stainless steel gangway suitable for floating platform access, designed to accommodate water level variations, including handrails, non-slip walking surface, hinges/connectors and all fittings, complete in all respects. |
| 427 | Providing and fixing of anchoring and mooring system for floating platform including anchors, ropes, chains, shackles and fittings, positioned to prevent drifting and ensure stability of floating restaurant platform under operating conditions, complete as per site requirements. |
| 428 | Providing all other accessories, fittings and finishing works required for completion of the floating platform including minor consumables, adjustments, safety fittings and incidental items not specifically mentioned but necessary to complete the work in all respects. |
| 429 | 12. CONSTRUCTION OF SHED ALONG WITH ANCILIARY FACILITIES IN PICNIC SPOT (2 NOS)Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 430 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 431 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 432 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 433 | Providing and laying dry flat brick flooring in required pattern complete. |
| 434 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 435 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 436 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 437 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 438 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 439 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 440 | Columns, Pillars, Piers,Abutments, PostsandStrutswith M.S. shutters |
| 441 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 442 | Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 443 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 444 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 445 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 446 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 447 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 448 | Neat cement punning. |
| 449 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 450 | 15mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 451 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
| 452 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture, of required shade and colour complete, as per manufacurer's specification. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 453 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 454 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 455 | Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622- 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-chargeSoluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid) |
| 456 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 fine sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand) and finished neat etc. complete as per direction of Engineer-in-charge. |
| 457 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying apriming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes |
| 458 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required etc. complete as per direction of Engineer-in-charge.0.80mm thick with zinc coating not less than 275gm/m2 |
| 459 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 460 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high- pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 461 | Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS 14616 and TADS 15:2001 (Part B), using 4mm thick float glasspanes for doors, windows and clerestory windows including ISI marked black enamelled M.S butt hinges with necessary screws as per direction of Engineer-incharge.30 mm thick shutters |
| 462 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :Gamair Wood 50 × 20 mm |
| 463 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 464 | Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in- Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) |
| 465 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 466 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture. |
| 467 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 468 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm |
| 469 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clampsat 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.15 mm nominal outer dia .Pipes |
| 470 | 25 mm nominal outer dia .Pipes |
| 471 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot&cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling&testing of jointscompleteas per direction of Engineer in Charge. External work32 mm nominal outer dia .Pipes |
| 472 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats complete :15 mm nominal bore |
| 473 | 25 mm nominal bore |
| 474 | Providing and fixing gunmetal gate valve with C.I. wheel of approved quality (screwed end):32 mm nominal bore |
| 475 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi Rigid PVC waste pipe for sink and wash basin 32 mm dia with length not less than 700 mm i/c PVC waste fittingsSemi rigid pipe 40 mm dia |
| 476 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 TypeA including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 477 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592Type-A including jointing with seal ring conforming to IS : 5382 leaving10mm gap for thermal expansionetc. complete as per direction of Engineer-in-charge :Coupler 110 mm |
| 478 | Single pushfit Coupler 110 mm |
| 479 | Bend 87.5° 110mm |
| 480 | Plain shoe 110mm |
| 481 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 482 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms. |
| 483 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore. |
| 484 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 485 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 486 | Providing and laying cement concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mmnominal size) upto haunches of S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe |
| 487 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
| 488 | Constructing soak pit 1.20 x 1.20 x 1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design |
| 489 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470, PartI.Payment will be made separetly on the basis of actual height based on relevant I.S.Code.For 20 users |
| 490 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 491 | Supply and fitting of one complete Portable Folding Table and Chair Set (1 Table + 4 Chairs); the table (approx. 1.20 m L x 0.60 m W) shall feature an 18 mm thick PLPB or HDPE top and a foldable understructure constructed from 25 x 25 mm square section Mild Steel (MS) tubing with a secure spring-loaded locking mechanism; the four matching chairs shall be constructed from 19 mm round section MS tubing and feature a seat and backrest upholstered in durable Vinyl (Rexine) or commercial-grade Fabric/HDPE with a secure locking mechanism, with all metal parts finished with Powder Coating and the entire set supplied and delivered complete in all respects. |
| 492 | 13. CONSTRUCTION OF AQUARIUMEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 493 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 494 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 495 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 496 | Providing and laying dry flat brick flooring in required pattern complete. |
| 497 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 498 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 499 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 500 | Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1:2 ( 1 Cement: 1 fine sand : 2 graded stone aggregate20 mm nominal size) |
| 501 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 502 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 503 | Columns, Pillars, Piers,Abutments, Post sand Struts with M.S. shutters |
| 504 | Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 505 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 506 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 507 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 508 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 509 | Neat cement punning. |
| 510 | Providing and applyingwhite cement based putty ofaverage thickness 1 mm, of approved brand andmanufacturer,overtheplasteredwallsurfacetopreparethe surface even and smooth complete. |
| 511 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 512 | 15mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 513 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
| 514 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 515 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 516 | Designing and execution of designer wall painting on interior walls of public aquarium, depicting aquatic / marine life themes such as fishes, corals, underwater scenery, biodiversity and educational graphics, using approved high-quality, waterproof, non-toxic, low-VOC acrylic/emulsion paints (with primer) suitable for indoor public spaces with high humidity. The work shall include surface preparation (cleaning, minor crack filling, putty where required), application of primer, base coats, detailed artistic hand painting / stencil / mixed-media technique, shading, highlighting and finishing coats to achieve vibrant, durable and visually appealing artwork. The item includes involvement of skilled artists, all materials, tools, scaffolding, protection of adjacent surfaces, curing, cleaning after completion, and execution complete in all respects as per approved theme, drawings, colour scheme and direction of Engineer-in-Charge. |
| 517 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 518 | Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622- 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-chargeSoluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid) |
| 519 | Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design, fixing in customize design etc. all complete as per direction of Engineer-in- Charge. The glass mosaic tiles tobe fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of alloperation, material and required pattern approved by Engineer-in-Charge. |
| 520 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 fine sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand) and finished neat etc. complete as per direction of Engineer-in-charge. |
| 521 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 522 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm at 100 mm centre to centre and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia. steel pulleys & with riveted bolts, nuts, locking arrangement, stoppers, handles, hold fast/anchor bolt including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approvedsteel primer etc. complete as required. |
| 523 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 524 | 21mm thick clear toughened Laminated glass for fins with holes |
| 525 | Providing, supplying, fabricating and installing complete aquarium display units consisting of toughened safety glass panels(excluding rate of toughened glass), factory-polished edges, precision-cut and bonded with aquarium-grade neutral cure silicone sealant to form fully leak-proof tanks of specified size as per approved drawing; including all necessary edge supports, bonding accessories, top covers made of aluminium framing with sliding glass shutters, and waterproof laminated aquarium base cabinets fitted with stainless steel hinges, hardware and finishing; complete with all materials, fixtures, consumables, equipment, handling, installation, testing and commissioning to ensure a stable, functional and display-ready aquarium system, all as per manufacturer’s specification and as directed by the Engineer-in-Charge. |
| 526 | Providing, supplying, fixing, installing, testing and commissioning a complete aquarium filtration and water-treatment system comprising external canister filters of suitable LPH capacity, UV sterilizers, submersible heaters with thermostatic control, air pumps with multi-outlet diffusers, wave-maker circulation pumps, RO water purification system and all required filter media including ceramic rings, bio-media, activated carbon, sponge modules, piping, valves, connectors and fittings; complete with all accessories, consumables, electrical connections, mounting arrangements, leak testing, trial operation and ensuring full functional performance of water purification and biological filtration as per manufacturer’s specifications and as directed by the Engineer-in-Charge. |
| 527 | Supplying, installing, testing and commissioning a complete aquarium lighting system comprising high-efficiency LED aquarium luminaires of appropriate wattage with full-spectrum day/night mode, moisture-proof build, integrated drivers, mounting brackets, electrical wiring, control switches, automated timers and all necessary hardware; including fixing, alignment, cabling, protection, and ensuring uniform illumination suitable for aquatic display and plant growth, all complete as per manufacturer’s recommendations and as directed by the Engineer-in-Charge. |
| 528 | Supplying and introducing assorted freshwater ornamental fish, large feature species, marine ornamental species, aquatic plants and live/artificial corals into the display tanks, including acclimatization, water conditioning, quarantine procedure, safe transportation, release protocols, and provision of starter feed and health supplements; ensuring species diversity, colour variation and compatibility as approved, and handing over a fully stocked and stable biological ecosystem, complete as per direction of the Engineer-in-Charge. |
| 529 | Providing and placing aquarium substrates including natural/coloured gravel, nutrient substrate, decorative stones, driftwood, 3D background panels, aquarium-grade silicone sealants, artificial décor elements and related accessories; including washing, preparation, fixing, arrangement of aesthetic aquascaping layouts, and ensuring stability and safe placement inside the tanks; all complete with materials, labour and finishing as directed by the Engineer-in-Charge. |
| 530 | 14. CONSTRUCTION OF WATER CASCADEEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 531 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 532 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 533 | Providing and laying dry flat brick flooring in required pattern complete. |
| 534 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 535 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 536 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 537 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 538 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 539 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 540 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 541 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 542 | Neat cement punning. |
| 543 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 544 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 545 | Providing and laying of boulder apron laid in wire crates made with 4mm dia GI wire conforming to IS: 280 & IS:4826 in 100 mm x 100 mm mesh (weaved diagonally)including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 40 kg each as per drawing and MoRT&H Technical specifications clause 2503. |
| 546 | Providing, supplying, installing, testing and commissioning the complete MEP system for an artificial water cascade, including heavy-duty submersible cascade pumps (energy-efficient, multi-stage) sized as per required head and discharge, HDPE/UPVC pressure-rated delivery pipelines with valves, unions, strainers and flow-control arrangements, electrical cabling from panel to pump with weatherproof conduits, earthing, pump starter panel with MCB/MCCB, contactors, protection relays and auto–manual control, installation of inline filtration unit and mesh pre-filter to avoid debris choking, water level sensors for dry-run protection, return-line arrangements, spillway channels and distribution manifold ensuring uniform cascading flow across all tiers; complete with all accessories, testing, commissioning and handing over as per direction of Engineer-in-Charge |
| 547 | 15. CONSTRUCTION OF DG & ELECTRIC ROOMEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 548 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 549 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 550 | Providing and laying dry flat brick flooring in required pattern complete. |
| 551 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 552 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 553 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 554 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 555 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 556 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 557 | Columns, Pillars, Piers,Abutments, Post sand Struts with M.S. shutters |
| 558 | Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 559 | Weather shade, Chajjas, corbels etc., including edges. |
| 560 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 561 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 562 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 563 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 564 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 565 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 566 | 15mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 567 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
| 568 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 569 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats) over and including waterthinnable priming coat with cement primer. |
| 570 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 571 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent over 20 mm (average) thick base of cement mortar 1:4 (1cement : 4 fine sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by theEngineer-in-Charge. |
| 572 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at theend by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 275mm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters & with handles, hold fast including embedding in cement concrete of required grade required for fixing in position, all necessary fittings, including applying of approved steel primer etc. complete as required:-80xl.25mm M.S. laths with 1.25 mm thick top cover. |
| 573 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm) |
| 574 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 575 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 576 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/ system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 577 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 TypeA including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 578 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592Type-A including jointing with seal ring conforming to IS : 5382 leaving10mm gap for thermal expansionetc. complete as per direction of Engineer-in-charge :Coupler 110 mm |
| 579 | Single pushfit Coupler 110 mm |
| 580 | Single equal tee without door 110x110x110mm |
| 581 | Single equal tee with door 110x110x110mm |
| 582 | Bend 87.5° 110mm |
| 583 | Plain shoe 110mm |
| 584 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard designInside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
| 585 | Constructing soak pit 1.20 x 1.20 x 1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design |
| 586 | 16. PROTECTION WORK ALONG WITH POND SIDE RAILINGSupplying ballies 100 mm dia well dressed and making shoe with end tappered upto 300 mm from the bottom including marking length and part of a metre as per drawing and specification.i) Sal Ballies |
| 587 | Providing and fitting, fixing ballies of 100 mm dia for horizontal, diagonal bracing, strut etc. with nails/ spikes and binding wire (GI 2.0 mm) as per drawing and specification.i) Sal Ballies |
| 588 | Handling and driving ballies of 100 mm dia upto the length required by heavy hammer as per drawing and specification. |
| 589 | Applying coal tar at least two coats on wood work including handling and stacking the coal tarred material at the work site as per Specification. |
| 590 | Providing and placing gunny/ polythene (of minimum wall thickness of 500 micron) bags filled with sand (of minmum qty of 0.034 cum) and properly manually stitched to avoid any leakage of sand as per specification. |
| 591 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 592 | Excavation for Structures With dewatering Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out,dewatering, construction of shoring, shuttering & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material.Ordinary Soil (i) Upto 3 m depth |
| 593 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. All kinds of soil |
| 594 | Providing and laying dry flat brick flooring in required pattern complete. |
| 595 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 596 | Providing concrete for plain/reinforced concrete in open foundationscomplete including formworkasperdrawings &MoRD technical specifications Clauses 802, 803, 900, 1202 and1203. (including centering, shuttering, staging etc. but excluding reinforcement).II P.C.C grade M 15(i) Nominal mix (1:2.5:5) |
| 597 | v. R.C.C grade M 25 |
| 598 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 599 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 600 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 601 | Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in foundation complete as per drawings & MoRD technical specifications Clauses 1000 & 1202. |
| 602 | Providing weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7. |
| 603 | Providing and constructing decorative R.C.C. railing, cast in-situ with required formwork and reinforcement, designed in an artistic wooden branch–like pattern as per approved drawing and direction of Engineer-in-Charge. The work includes preparing the base, fixing necessary steel reinforcement, fabrication of irregular branch-shaped members, application of high-quality cement-based mortar for surface texturing, carving of natural wood grains and knots, finishing with two or more coats of exterior-grade acrylic paint in wooden shades, including primer, curing, all materials, labour, tools, scaffolding, colour shading, and complete workmanship to achieve the natural wooden appearance as per direction of Engineer-in-charge. |
| 604 | 17. CONSTRUCTION OF DRAGON BRIDGE( FOOT BRIDGE)CONSTRUCTION OF DRAGON BRIDGE(FOOT BRIDGE)Supplying ballies 100 mm dia well dressed and making shoe with end tappered upto 300 mm from the bottom including marking length and part of a metre as per drawing and specification.i) Sal Ballies |
| 605 | Providing and fitting, fixing ballies of 100 mm dia for horizontal, diagonal bracing, strut etc. with nails/ spikes and binding wire (GI 2.0 mm) as per drawing and specification.i) Sal Ballies |
| 606 | Handling and driving ballies of 100 mm dia upto the length required by heavy hammer as per drawing and specification. |
| 607 | Applying coal tar at least two coats on wood work including handling and stacking the coal tarred material at the work site as per Specification. |
| 608 | Providing and placing gunny/ polythene (of minimum wall thickness of 500 micron) bags filled with sand (of minmum qty of 0.034 cum) and properly manually stitched to avoid any leakage of sand as per specification. |
| 609 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 610 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 611 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 612 | Providing and laying dry flat brick flooring in required pattern complete. |
| 613 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level 1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 614 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 615 | Columns, piers, abutments, pillaras, posts and struts |
| 616 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level:1:1:2 ( 1 Cement: 1 fine sand : 2 graded stone aggregate 20 mm nominal size) |
| 617 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 618 | First class brick work in foundation and plinth including cost of all materials as required complete In cement mortar 1:4 ( 1 cement : 4 fine sand ) |
| 619 | 12 mm cement plaster of mix Cement mortar 1:6 (1 cement : 6 fine sand) |
| 620 | ProvidingandfixingPrecastchequeredcementconcrete tiles18mmthick, laid in footpath&courtyard, on20 mmthickbedof cementmortar1:4(1 cement :4 fine sand) jointedwithneatcementslurryincludingrubbing and cleaning etc. all complete as per direction of Engineer-in-charge.In dark shade using ordinary cement |
| 621 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 622 | Providing structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as required. |
| 623 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required: In stringers, treads, landingetc.of staircases including use of chequered plate wherever required, all complete. |
| 624 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of aluminium composite panel material of approved thickness and specification. The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bimetallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. upto two decimal places.\\" |
| 625 | 18. FUN FAIR ZONE EQUIPMENTSBREAK DANCE Supply, fabrication, transportation, installation, testing and commissioning of Break Dance Bogi/Cabin made of high-quality FRP (Fiber Reinforced Plastic) moulded to approved shape and design, including internal MS pipe framework and MS plates for mounting, stiffening ribs, seat base, safety handrails, footrest, fixing brackets and all necessary supports.The item includes colourful multi-shade painting, artwork, decorative graphics, surface finishing, lacquer / PU clear coat for weather resistance, fixing of seats with cushioning, safety belts, nuts, bolts, washers, and complete installation as per manufacturer’s design, complete in all respects. |
| 626 | Supply, fabrication, erection and installation of rotating platform constructed from M.S. angle framework using sections of 35×35 mm, 30×5 mm and 25×5 mm, fully welded, aligned and braced.Top surface to be finished with 3 mm thick aluminium chequered plate, properly fixed with countersunk bolts.The item includes 40 ft diameter platform (approx.), 2 HP electric motors – 4 Nos., complete with taper roller bearings, motor base frame, coupling, pulleys, belts, lubrication system, guards, alignment and load testing.Complete with all accessories, wiring up to motor terminal, trial run and commissioning. |
| 627 | Supply, fabrication and erection of main load-bearing steel structure for Break Dance ride using M.S. Channels of sizes 3\\", 4\\" and 6\\", 10\\" Girders, 7\\" diameter main shaft, heavy-duty 6½\\" × 11\\" taper roller bearings, and 3 HP drive motor with gearbox/coupling arrangement.The work includes cutting, welding, grinding, alignment, base plates, anchor bolts, anti-rust primer, finishing paint, load balancing and structural stability checks, complete as per approved design and safety norms. |
| 628 | Supply and installation of lower foundation drive assembly comprising 3\\" × 1½\\" M.S. channels, 7 Nos. tyre wheels, 18\\" diameter × 12 mm thick M.S. circular plates, complete gear set, 3\\" diameter shafts – 4 Nos., 18\\" × 12\\" M.S. plates, 3\\" × 6 mm M.S. patties – 16 Nos., bearing housings and all mechanical components.Includes fabrication, machining, alignment, grouting, lubrication system, protective covers and complete operational setup, tested for smooth rotation and load performance. |
| 629 | Supply, fabrication and installation of safety railing and booking counter system made of 1\\" diameter stainless steel pipe structure, including curved and straight railings around the ride area, 200 mm wide SS/MS pipe posts, fixing clamps and anchor fasteners. Includes booking counter, operative/control cabin, internal counter fittings, lighting fixtures, decorative lighting, Darshan/visual lighting arrangement, switches, wiring, and basic electrical fittings.Complete with polishing, finishing, signage provisions and integration with ride operation area, ready for public use. |
| 630 | CAROUSELSupply, fabrication, transportation, installation, testing and commissioning of Horse-shaped Bogi made of high-quality FRP (Fiber Reinforced Plastic), moulded to approved design and size, including internal iron/MS support framework, MS base plates for mounting, stiffeners, brackets and fixing arrangements.The item includes multi-colour decorative painting, artwork, surface finishing, lacquer / PU clear coating for weather and UV resistance, proper fastening with nuts, bolts and washers, and complete fixing on carousel arms, complete in all respects |
| 631 | Supply, fabrication and installation of FRP Chairs/Seats suitable for carousel ride, including MS pipe framework, MS mounting plates, supports, stiffeners and safety fittings.Includes colourful painting with lacquer finish, smooth edges, proper seating ergonomics, secure fixing to the rotating structure, and all accessories required for safe and durable operation, complete as per approved design. |
| 632 | Supply, fabrication, erection and installation of main carousel structure made from 2\\" diameter M.S. pipe frame, including vertical and radial members, bracing, mounting arms, and base supports.The item includes 7\\" diameter main shaft, heavy-duty bearings, electric drive motor of suitable capacity, motor base frame, coupling arrangement, alignment, welding, grinding, anti-corrosive primer and final paint.Complete with all mechanical accessories, alignment, trial run and structural stability checks. |
| 633 | Supply and installation of heavy-duty main gearbox suitable for carousel operation, including reduction gearbox, couplings, shafts, bearing housings, lubrication system, protective covers and mounting arrangements.Includes complete operating system comprising electrical control panel, on/off switches, emergency stop, wiring up to motor terminal, speed control (where required), earthing and safety interlocks.Complete with testing, commissioning, smooth operational trial and handing over in working condition. |
| 634 | JUMPING FROGSupply, fabrication, transportation, installation, testing and commissioning of frog-shaped bogi/cabin made of high-quality FRP (Fiber Reinforced Plastic), moulded to approved design and dimensions, including internal iron/MS support framework, MS base plates for mounting, stiffeners, brackets and all fixing arrangements.The item includes multi-colour decorative painting, artwork, surface finishing, lacquering / PU clear coat for weather resistance, proper fastening with nuts, bolts and washers, and complete fixing to the ride mechanism, complete in all respects. |
| 635 | Supply, fabrication, erection and installation of main jumping frog ride structure made of 2\\" diameter M.S. pipe frame, including vertical posts, cross bracings, arms, platforms and complete ground fixing system comprising base plates, anchor bolts, foundation grouting and alignment.Includes guard rails / safety railings, mounting frames, finishing with anti-corrosive primer and enamel paint, complete with all welding, cutting, grinding and structural stability checks, ready for operation. |
| 636 | Supply and installation of electric drive motor of suitable capacity for jumping frog operation, including motor base frame, coupling, shafts, bearings, alignment, lubrication arrangement and protective guards.The item includes integration with the main structure, trial run under load and smooth operation testing, complete. |
| 637 | Supply, fabrication, erection, installation, testing and commissioning of complete Ferris Wheel (Giant Wheel) amusement ride, including FRP cabins/bogies moulded to approved shape and size with internal MS/iron support framework, MS base plates, seating and safety handholds, multi-colour decorative painting, artwork and lacquer/PU clear coating; complete main structural framework fabricated from heavy MS pipes/channels/angles comprising central hub, rim and spoke structure, support towers, cross bracing, base plates, anchor bolts and foundation fixing; complete mechanical and drive system including heavy-duty main shaft, bearing housings, reduction gearbox, electric drive motor of suitable capacity, coupling/chain or belt drive arrangement, lubrication system and protective guards; and complete electrical, operating and safety system including control panel with on/off and emergency stop, wiring up to motor terminal, earthing, operator platform, access ladder, safety railing around operating area, alignment, load testing, trial run and handing over in fully functional condition, inclusive of all materials, labour, transportation, tools & tackles and incidentals, complete. |
| 638 | Supply, design, fabrication, erection, installation, testing and commissioning of complete Mirror Maze, comprising detailed planning and layout of internal maze pathways with entry and exit arrangement; fabrication and erection of internal structural framework using MS square pipe/angle sections including vertical posts, horizontal members, partitions, base plates, anchoring to floor, top bracing and stiffeners, complete with cutting, welding, alignment, anti-corrosive primer and final paint finish; supply and fixing of high-quality safety mirror panels of required thickness (toughened/laminated mirror glass) on all internal walls and partitions using aluminium channels, clamps, rubber beading and safety backing, with smooth finished edges and accurate alignment to achieve required mirror illusion effect; providing and fixing non-slip flooring using anti-skid vinyl/rubber mat/tiles over prepared base including edge finishing; providing and installation of complete lighting and electrical system comprising LED strip lights/spotlights suitable for mirror maze effect, concealed wiring, switches, control arrangements, earthing and testing; providing safety and user-protection features including mirror edge guards, corner protectors, warning and directional signage, emergency lighting and basic ventilation provision; and testing, commissioning and handing over of the entire mirror maze in safe, stable and operational condition, inclusive of all materials, labour, transportation, tools & tackles, scaffolding and incidentals, complete. |
| 639 | Supply, design, fabrication, erection, installation, testing and commissioning of complete Sky Driver amusement ride, comprising main structural system fabricated from heavy-duty MS pipes, channels, angles and plates including central mast/tower, radial arms, support frames, cross-bracings, base plates, anchor bolts and foundation fixing, complete with cutting, welding, alignment, anti-corrosive primer and final paint finish; ride arms and passenger seating units including MS fabricated arms, FRP/MS seating gondola/chairs with safety harness, restraints, handholds, footrests and protective padding, finished with decorative painting and lacquer/PU coating; complete mechanical and drive system including heavy-duty main shaft, bearings and bearing housings, reduction gearbox, electric drive motor(s) of suitable capacity, coupling/chain or belt drive arrangement, braking system, lubrication system, balancing mechanism and protective guards; complete electrical, operating and safety system including control panel with start/stop controls, speed regulation, emergency stop, interlocks, wiring up to motor terminals, earthing and safety cut-off devices; providing and fixing operator platform, access ladder/staircase, safety railing and barricading around ride area; and testing, commissioning, load trial, safety checks and handing over of the Sky Driver ride in fully functional, stable and safe operating condition, inclusive of all materials, labour, transportation, tools & tackles, scaffolding, permits, testing and all incidentals, complete. |
| 640 | 19. KIDDIE KINGDOM & Kid's TOT-LOT (Cottage District)Supply, fabrication, installation, testing and commissioning of 4-seater see-saw for children’s park, of approx. 8 ft length and 2 ft height, made of MS structural frame including main beam and pivot assembly, complete with FRP seats on MS seat frames, hand grips and foot rests, MS work finished with epoxy paint and FRP seats finished with polyurethane paint, including ground fixing, alignment, safety checks and handing over in working condition, inclusive of all materials, labour, transportation and incidentals, complete. |
| 641 | Supply, fabrication, installation, testing and commissioning of 3-in-one swing for children’s park, of approx. 6 ft height, made of GI pipe structural framework including posts, top beam and bracings, suitable for 3 × 2 seating arrangement, complete with swing seats, chains, hangers and safety fittings, finished with epoxy paint, including ground fixing, alignment, safety checks and handing over in working condition, inclusive of all materials, labour, transportation and incidentals, complete. |
| 642 | Supply, fabrication, installation, testing and commissioning of combination play set for children’s park, of approx. 5 ft height, made of GI pipe structural framework with platforms, ladders and guard rails, complete with FRP slide(s), GI structure finished with epoxy paint and FRP components finished with polyurethane paint, including ground fixing, alignment, safety checks and handing over in working condition, inclusive of all materials, labour, transportation and incidentals, complete. |
| 643 | Supply, fabrication, installation, testing and commissioning of Spider Net Rock Climber for children’s park, of approx. 10 ft height, made of GI pipe structural framework with spider-net rope climbing arrangement, finished with epoxy paint, including base plates, ground fixing, alignment, safety checks and handing over in working condition, inclusive of all materials, labour, transportation and incidentals, complete. |
| 644 | Supply, fabrication, installation, testing and commissioning of complete Roko Spiral Slide for children’s park, made of rotomoulded LLDPE (ROKO) spiral slide sections with entry and exit, complete with MS/GI supporting structure, platforms, ladder/steps, handrails, guard rails, base plates and ground fixing, finished with corrosion-resistant paint/powder coating, including all safety fittings, alignment, testing and handing over in safe and functional condition, inclusive of all materials, labour, transportation and incidentals, complete. |
| 645 | Supplying, Fitting & Fixing of 3 seater garden bench made of cast ironhegs and wooden/FRP plank as per approved design of Length 1500mm, Height 400mm, Width of seating portion 500mm. The Bench to be fixed to the ground using long anchor fasteners complete, all as per manufacturer‟s specification and direction of Engineer -in- charge. |
| 646 | 20. CONSTRUCTION OF AQUA PARK ENTRY GATEEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 647 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 648 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 649 | Providing and laying dry flat brick flooring in required pattern complete. |
| 650 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 651 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 652 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 653 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 654 | Columns, Pillars, Piers,Abutments, PostsandStrutswith M.S. shutters |
| 655 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 656 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 657 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 658 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 659 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 660 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 661 | Providing, fabricating and installing a thematic Aqua-wave entry gate structure on both sides of the pathway consisting of curved wave-form vertical fins made of MS framework with CNC-cut steel plates, finished with multi-shade exterior grade polyurethane paint, including embedded base plates, anchor bolts, grouting and anti-corrosive coating; integrated decorative rock-mount signage made of FRP/GRP with embossed 3D lettering, exterior UV-resistant paint finish, and internal steel bracing; formation of peripheral landscape beds at the base of each gate element including soil preparation, geo-membrane lining, decorative edging, plantation of ornamental shrubs/seasonal flowers and drip-line watering provision; complete in all respects including design detailing, fabrication, transport, erection, finishing and all incidental works as directed by Engineer-in-Charge |
| 662 | 21. AQUA PARK EQUIPMENTSSupply, design, fabrication, installation, testing and commissioning of complete Crazy Cruise Water Slide for aqua park, comprising FRP water slide flume sections of approved profile, thickness and colour, UV-stabilized, water-resistant and suitable for continuous wet operation, including entry section, spiral/curved slide body, splash landing section and exit arrangement; complete supporting structural framework made of hot-dip galvanized / epoxy-painted MS or GI members including vertical columns, bracings, platforms, stairway access, handrails and guard rails, complete with base plates, anchor bolts and foundation fixing; water circulation system including water inlet pipelines, spray nozzles, valves and connection to pump line; safety features including non-slip stair treads, side guards, rounded edges, signage and rider safety provisions; finishing works, alignment, hydraulic testing, trial operation, safety checks and handing over of the slide in safe, stable and fully functional condition, inclusive of all materials, labour, transportation, tools & tackles and incidentals, complete. |
| 663 | Supply, design, fabrication, installation, testing and commissioning of complete Rain Dance system for aqua park, comprising structural framework made of hot-dip galvanized / epoxy-painted MS or GI pipes including columns, overhead grid, arches or ring frame for mounting water effects, complete with base plates, anchor bolts and foundation fixing; water distribution system including PVC/HDPE pipelines, overhead spray lines, rain nozzles, mushroom showers, jets and fittings, complete with valves, unions and supports; pumping and control arrangement including connection to pump line, flow control valves and basic control panel/switching system; flooring and safety features including non-slip flooring/tiles, proper drainage slope, drain grating, safety railing or barricading where required, warning signage and rounded edges; finishing works, alignment, hydraulic testing, trial run, safety checks and handing over of the rain dance area in safe, stable and fully functional condition, inclusive of all materials, labour, transportation, tools & tackles and incidentals, complete. |
| 664 | Providing, fabricating and constructing Zorb Ball launching deck, comprising a raised, curved / inclined launching platform designed for safe entry and controlled release of zorb balls, constructed using structural steel / RCC framing with anti-corrosive treatment, complete with non-slip deck flooring in treated timber / WPC planks / chequered plate with rubberized matting, side safety kerbs, edge protection and smooth transition profile. Item includes guide rails / side barriers in MS / SS pipes, safety handrails with vertical balusters, entry gate arrangement, anchoring over RCC foundation / pedestal, shock-absorbing base, drainage provisions, surface finishing with weather-resistant coatings, signage fixing points, and all necessary fittings. The work includes design compliance for load, safety and operational requirements, all materials, labour, fabrication, transportation, erection, alignment, levelling, testing, protection during execution and incidentals, complete in all respects as per approved drawings and directions of Engineer-in-Charge. |
| 665 | Supply & Delivery of transparent inflatable Zorb Ball made from high-strength TPU / PVC material of approved thickness, UV-resistant, puncture-resistant and suitable for repeated water use. The item shall include zipper / airtight sealing system, safety harness (if applicable), air blower / pump, anchoring and guiding arrangement, and all necessary accessories for safe operation. The work shall also include testing, trial runs, safety checks, operational demonstration to park staff and handing over, complete in all respects as per approved specifications and direction of Engineer-in-Charge. |
| 666 | Supply, design, fabrication, erection, installation, testing and commissioning of artificial rock waterfall feature, comprising structural steel internal framework designed to required height and profile, including base frame, supports and anchoring; artificial rock formation developed using MS mesh, polymer-modified cement mortar / GFRC / shotcrete sculpting to create natural rock texture, contours and cavities, complete with surface carving and finishing; waterfall system including vertical spillway/weir arrangement, concealed water distribution pipes, inlet nozzles, flow regulators, splash basin and return outlets; water circulation system comprising connection to pump line, valves and fittings (pump measured separately unless specified), ensuring continuous and uniform water flow; surface finishing with weather-resistant, non-toxic mineral/oxide colouring, texture coating and protective sealant to achieve natural stone appearance; base pool interface and edge finishing including pebble bed/stone finish at splash zone; and testing, commissioning and trial operation of the complete waterfall feature to ensure smooth water flow, structural stability and visual effect, inclusive of all materials, labour, scaffolding, tools & tackles, transportation and incidentals, complete. |
| 667 | 22. CONSTRUCTION OF AQUA PARK CHANGING ROOMEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 668 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 669 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 670 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 671 | Providing and laying dry flat brick flooring in required pattern complete. |
| 672 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 673 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 674 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 675 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 676 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 677 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 678 | Columns, Pillars, Piers,Abutments, PostsandStrutswith M.S. shutters |
| 679 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 680 | Weather shade, Chajjas, corbels etc., including edges. |
| 681 | Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 682 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 683 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 684 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 685 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 686 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 687 | Neat cement punning. |
| 688 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 689 | 15mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 690 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
| 691 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture, of required shade and colour complete, as per manufacurer's specification. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 692 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 693 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 694 | Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622- 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-chargeSoluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid) |
| 695 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 696 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high- pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 697 | Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS 14616 and TADS 15:2001 (Part B), using 4mm thick float glasspanes for doors, windows and clerestory windows including ISI marked black enamelled M.S butt hinges with necessary screws as per direction of Engineer-incharge.30 mm thick shutters |
| 698 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :Gamair Wood 50 × 20 mm |
| 699 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 700 | Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where everrequired) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & sizeaccording to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shallbe also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in- Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead ofappropriate dimension. (Area upto 0.75 sqm.) |
| 701 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 702 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture. |
| 703 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 704 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm |
| 705 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clampsat 1.00m spacing. This includes jointingof pipes & fittings with one step CPVC solvent cement and testing of joints complete asper direction of Engineer in Charge. Internal work - Exposed on wall25 mm nominal outer dia .Pipes |
| 706 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clampsat 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.15 mm nominal outer dia .Pipes |
| 707 | 25 mm nominal outer dia .Pipes |
| 708 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot&cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling&testing of jointscompleteas per direction of Engineer in Charge. External work32 mm nominal outer dia .Pipes |
| 709 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats complete :15 mm nominal bore |
| 710 | 25 mm nominal bore |
| 711 | Providing and fixing gunmetal gate valve with C.I. wheel of approved quality (screwed end):32 mm nominal bore |
| 712 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi Rigid PVC waste pipe for sink and wash basin 32 mm dia with length not less than 700 mm i/c PVC waste fittingsSemi rigid pipe 40 mm dia |
| 713 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 TypeA including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 714 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592Type-A including jointing with seal ring conforming to IS : 5382 leaving10mm gap for thermal expansionetc. complete as per direction of Engineer-in-charge :Coupler 110 mm |
| 715 | Single pushfit Coupler 110 mm |
| 716 | Bend 87.5° 110mm |
| 717 | Plain shoe 110mm |
| 718 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 719 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms. |
| 720 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore. |
| 721 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 722 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 723 | Providing and laying cement concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mmnominal size) upto haunches of S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe |
| 724 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard designInside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
| 725 | Constructing soak pit 1.20 x 1.20 x 1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design |
| 726 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,PartI.Payment will be made separetly on the basis of actual height based on relevant I.S.Code.For 20 users |
| 727 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 728 | Supply and fitting of one complete Single-User Office Workstation Set, consisting of a linear desk (approx. 1.20 m W x 0.60 m D x 0.75 m H) constructed using 25 mm thick E1 Grade Pre-Laminated Particle Board for the tabletop with 2 mm PVC edge banding and supported by an MS Powder Coated Frame, complete with one Mobile Pedestal Unit (18 mm thick PLPB, three drawers, lockable castors, and telescopic channels); the set also includes one High-Back Ergonomic Revolving Chair featuring a breathable Mesh backrest, a seat cushion made of 45 kg/m^3 High-Density PU Foam, a Synchronous Multi-Locking Mechanism, and adjustable armrests on a durable Nylon/Chrome Base, with the rate being inclusive of all materials, fabrication, transport, and final installation complete in position. |
| 729 | Supply and fitting of one Double Door Steel Almirah (Overall Dimensions: 1.98 m x 0.90 m x 0.45 m D) constructed from high-grade CRCA (Cold Rolled Close Annealed) Steel Sheet, with the main body and doors having a minimum thickness of 20 Gauge (1.0 mm), treated via a Seven-Tank Process and finished with a durable Epoxy Polyester Powder Coating (min. 50 micronsb ); the Almirah shall include a secure Three-Way Locking Mechanism, one internal safe/locker box, a hanging rod, and adjustable internal shelving, with the rate being inclusive of all materials, detailed fabrication, finishing processes, transport, and final fixing complete in position. |
| 730 | Wooden Chair with arms (Standard Size) Made by Teak wood frame with back joint leg/curve leg, front leg of 45m x 45mm sec, ties are 70mm x 20mm thick and 45mm x 20mm, seat Hard wood planks of 15mm thick, nicely polish and all Complete. |
| 731 | 23.Construction of Food KiosksEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 732 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 733 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 734 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 735 | Providing and laying dry flat brick flooring in required pattern complete. |
| 736 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 737 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 738 | 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement |
| 739 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 740 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 741 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 742 | Columns, Pillars, Piers,Abutments, PostsandStrutswith M.S. shutters |
| 743 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 744 | Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 745 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 746 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 747 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 748 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 749 | Neat cement punning. |
| 750 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 751 | 15mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 752 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
| 753 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture, of required shade and colour complete, as per manufacurer's specification. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]New work ( two or more coats) over and including waterthinnable priming coat with cement primer. |
| 754 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 755 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 756 | Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622- 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-chargeSoluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid) |
| 757 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 fine sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand) and finished neat etc. complete as per direction of Engineer-in-charge. |
| 758 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 759 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass (weight not less than 10ks/Sqm) panes including black enamelled ISI marked MS butt hinges with necessary screws.35 mm thick |
| 760 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :Gamair Wood 50 × 20 mm |
| 761 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture. |
| 762 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm |
| 763 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 TypeA including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 764 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592Type-A including jointing with seal ring conforming to IS : 5382 leaving10mm gap for thermal expansionetc. complete as per direction of Engineer-in-charge :Coupler 110 mm |
| 765 | Bend 87.5° 110mm |
| 766 | Providing and laying cement concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mmnominal size) upto haunches of S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe |
| 767 | 24. Construction of Cottage District Entry GateEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 768 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 769 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 770 | Providing and laying dry flat brick flooring in required pattern complete. |
| 771 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 772 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 773 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 774 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 775 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 776 | Columns, Pillars, Piers,Abutments, PostsandStrutswith M.S. shutters |
| 777 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 778 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 779 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 780 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 781 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 782 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 783 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying apriming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes |
| 784 | Aluminium Composite Panels of 4mm total thickness with Top coil – 0.50mm AA3003 / AA3105 / AA5005 Grade manufactured as per IS-737 1986, FR Grade Class B1 with 3mm Mineral Core with minimum 70-72% Inorganic content (Aluminium Hydroxide and Magnesium Hydroxide) 28-30% Organic content (LDPE) conforming to ASTM E-119-16,18 and EN 13501-1, class B1,and Bottom coil – 0.50mm AA3003 / AA3105 / AA5005 Grade, manufactured as per IS-737 1986 with minimum 25 microns lead free PVDF Coating conforming to AAMA2605 on top coil and Service coating on Back Coil (4 - 6 microns) having minimum panel weight of 7.5 Kg/m2 |
| 785 | Design, fabrication, supply and installation of logo / name signage on the entry gate, made of 3D built-up letters / solid acrylic / FRP / HDU board (as approved), finished with weather-resistant paint / PU coating, fixed on gate structure with concealed supports, complete in all respects as per approved design and direction of Engineer-in-Charge. |
| 786 | Painting Steel work with Deluxe Multi Surface Paint to givean even shade. Two or more coat applied @ 0.90 ltr/ 10sqm over an under coat of primer applied @ 0.80 ltr/ 10sqm of approved brand and manufacture |
| 787 | 25. Construction of Cottage District Reception Block Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 788 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 789 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 790 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 791 | Providing and laying dry flat brick flooring in required pattern complete. |
| 792 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 793 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 794 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 795 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 796 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 797 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 798 | Columns, Pillars, Piers,Abutments, PostsandStrutswith M.S. shutters |
| 799 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 800 | Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 801 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 802 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 803 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 804 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 805 | Neat cement punning. |
| 806 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 807 | 15mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 808 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
| 809 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture, of required shade and colour complete, as per manufacurer's specification. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]New work ( two or more coats) over and including waterthinnable priming coat with cement primer. |
| 810 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 811 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 812 | Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622- 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-chargeSoluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid) |
| 813 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 fine sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand) and finished neat etc. complete as per direction of Engineer-in-charge. |
| 814 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 815 | Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS 14616 and TADS 15:2001 (Part B), using 4mm thick float glasspanes for doors, windows and clerestory windows including ISI marked black enamelled M.S butt hinges with necessary screws as per direction of Engineer-incharge.30 mm thick shutters |
| 816 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). |
| 817 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :Gamair Wood 50 × 20 mm |
| 818 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 819 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture. |
| 820 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 821 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm |
| 822 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 TypeA including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 823 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592Type-A including jointing with seal ring conforming to IS : 5382 leaving10mm gap for thermal expansionetc. complete as per direction of Engineer-in-charge :Coupler 110 mm |
| 824 | Bend 87.5° 110mm |
| 825 | Plain shoe 110mm |
| 826 | Providing and laying cement concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mmnominal size) upto haunches of S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe |
| 827 | Supply and fitting of one Luxury Custom Office Reception Table/Counter Desk (Overall Size: approx. 2.40 m L x 0.80 m D x 1.10 m H) constructed using 19 mm thick BWP/BWR Grade Plywood for the structure, fully finished with 1.0 mm thick high-gloss or matte decorative laminate in approved colours (e.g., Charcoal Grey/Light Grey); the design shall incorporate decorative Grade 304 Stainless Steel (SS) Pillars/Strips on the front, feature a premium front transaction top, utilize Light Grey/White Laminate for the interior workspace, and include one integrated three-drawer pedestal unit with centralized locking and premium soft-close hardware, with the rate being inclusive of all materials, fabrication, transport, and final installation complete in position. |
| 828 | Wooden Chair with arms (Standard Size) Made by Teak wood frame with back joint leg/curve leg, front leg of 45m x 45mm sec, ties are 70mm x 20mm thick and 45mm x 20mm, seat Hard wood planks of 15mm thick, nicely polish and all Complete. |
| 829 | Supply and fitting of one Three-Seater Fabric Sofa (Overall Dimensions: 2.00 m x 0.90 m x 0.85 mH) with the main internal structure constructed from Chemically Treated and Seasoned Sal Wood / Teak Wood (or equivalent approved hard timber), utilizing high-strength elastic webbing or zigzag springs for durable seat suspension; the seating shall incorporate High-Resilience (HR) PU foam with a minimum density of 40 kg/m^3 for the seat cushions and 32 kg/m^3 foam/Poly-fill for the back cushions; the sofa is to be fully upholstered in Approved Grade Commercial Fabric having a minimum GSM of 350 and a Rub Count of 25,000+, supported by Solid Wood/Stainless Steel Legs, with the rate inclusive of all materials, detailed stitching, finishing, transportation, and complete fixing as per approved sample and design. |
| 830 | 26. Construction of Family CottageEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 831 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 832 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 833 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 834 | Providing and laying dry flat brick flooring in required pattern complete. |
| 835 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 836 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 837 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 838 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 839 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 840 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 841 | Columns, Pillars, Piers,Abutments, PostsandStrutswith M.S. shutters |
| 842 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 843 | Weather shade, Chajjas, corbels etc., including edges. |
| 844 | Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 845 | Stairs (excluding landings) except spiral-staircases withwooden plank |
| 846 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 847 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 848 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 849 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 850 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 851 | Neat cement punning. |
| 852 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 853 | 15mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 854 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
| 855 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture, of required shade and colour complete, as per manufacurer's specification. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 856 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 857 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 858 | Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622- 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-chargeSoluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid) |
| 859 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 fine sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand) and finished neat etc. complete as per direction of Engineer-in-charge. |
| 860 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board. |
| 861 | Providing and fixing hand rail using structural steel etc. of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete as required:-M.S. tube |
| 862 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 863 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high- pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 864 | Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS 14616 and TADS 15:2001 (Part B), using 4mm thick float glasspanes for doors, windows and clerestory windows including ISI marked black enamelled M.S butt hinges with necessary screws as per direction of Engineer-incharge.30 mm thick shutters |
| 865 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at theend by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 275mm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters & with handles, hold fast including embedding in cement concrete of required grade required for fixing in position, all necessary fittings, including applying of approved steel primer etc. complete as required:-80xl.25mm M.S. laths with 1.25 mm thick top cover. |
| 866 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :Gamair Wood 50 × 20 mm |
| 867 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 868 | Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in- Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) |
| 869 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 870 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture. |
| 871 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 872 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm |
| 873 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clampsat 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.15 mm nominal outer dia .Pipes |
| 874 | 25 mm nominal outer dia .Pipes |
| 875 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot&cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling&testing of jointscompleteas per direction of Engineer in Charge. External work32 mm nominal outer dia .Pipes |
| 876 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats complete :15 mm nominal bore |
| 877 | 25 mm nominal bore |
| 878 | Providing and fixing gunmetal gate valve with C.I. wheel of approved quality (screwed end):32 mm nominal bore |
| 879 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi Rigid PVC waste pipe for sink and wash basin 32 mm dia with length not less than 700 mm i/c PVC waste fittingsSemi rigid pipe 40 mm dia |
| 880 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 TypeA including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 881 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592Type-A including jointing with seal ring conforming to IS : 5382 leaving10mm gap for thermal expansionetc. complete as per direction of Engineer-in-charge :Coupler 110 mm |
| 882 | Single pushfit Coupler 110 mm |
| 883 | Bend 87.5° 110mm |
| 884 | Plain shoe 110mm |
| 885 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 886 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms. |
| 887 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore. |
| 888 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 889 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 890 | Providing and laying cement concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mmnominal size) upto haunches of S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe |
| 891 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard designInside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
| 892 | Constructing soak pit 1.20 x 1.20 x 1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design |
| 893 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,PartI.Payment will be made separetly on the basis of actual height based on relevant I.S.Code.For 20 users |
| 894 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 895 | Supply ,Installation and Commissioning of LED Television (49 inch)Full HD (Resolution: 1920 x 1080p), Refresh Rate: 50 hertz, Connectivity - Input: 4xHDMI, 3xUSB, Audio: 10 W output Make: Sony/ LG or equivalent. |
| 896 | Supply & Installation of 6' x 40'' Antique Rustic Folding Farm Table Set with 6 Cross Back Chairs and Cushions |
| 897 | Supply and fitting of one Double-Sided Box-Type Double Bed (Incl. Mattress Size: approx. 1.83 m x 1.22 m or 6 ft x 4 ft ), constructed with 18 mm BWP Commercial Plywood for the frame and storage box sides and 12 mm BWP Plywood for the box bottom, fully finished with 0.8 mm thick decorative laminate and PVC/Teak lipping on all exposed edges, featuring a double-sided lift-up storage mechanism and necessary durable hardware, finished complete in all respects as per design and approval. |
| 898 | Supply and fitting of one Three-Seater Fabric Sofa (Overall Dimensions: 2.00 m x 0.90 m x 0.85 mH) with the main internal structure constructed from Chemically Treated and Seasoned Sal Wood / Teak Wood (or equivalent approved hard timber), utilizing high-strength elastic webbing or zigzag springs for durable seat suspension; the seating shall incorporate High-Resilience (HR) PU foam with a minimum density of 40 kg/m^3 for the seat cushions and 32 kg/m^3 foam/Poly-fill for the back cushions; the sofa is to be fully upholstered in Approved Grade Commercial Fabric having a minimum GSM of 350 and a Rub Count of 25,000+, supported by Solid Wood/Stainless Steel Legs, with the rate inclusive of all materials, detailed stitching, finishing, transportation, and complete fixing as per approved sample and design. |
| 899 | Supply and fitting of one Double Door Steel Almirah (Overall Dimensions: 1.98 m x 0.90 m x 0.45 m D) constructed from high-grade CRCA (Cold Rolled Close Annealed) Steel Sheet, with the main body and doors having a minimum thickness of 20 Gauge (1.0 mm), treated via a Seven-Tank Process and finished with a durable Epoxy Polyester Powder Coating (min. 50 micronsb ); the Almirah shall include a secure Three-Way Locking Mechanism, one internal safe/locker box, a hanging rod, and adjustable internal shelving, with the rate being inclusive of all materials, detailed fabrication, finishing processes, transport, and final fixing complete in position. |
| 900 | 27. Construction of Deluxe Cottage (For 3 nos.)Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 901 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 902 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 903 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 904 | Providing and laying dry flat brick flooring in required pattern complete. |
| 905 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 906 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 907 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 908 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 909 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 910 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 911 | Columns, Pillars, Piers,Abutments, PostsandStrutswith M.S. shutters |
| 912 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 913 | Weather shade, Chajjas, corbels etc., including edges. |
| 914 | Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 915 | Stairs (excluding landings) except spiral-staircases withwooden plank |
| 916 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 917 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 918 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 919 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 920 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 921 | Neat cement punning. |
| 922 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 923 | 15mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 924 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
| 925 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture, of required shade and colour complete, as per manufacurer's specification. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 926 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 927 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 928 | Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622- 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-charge Soluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid) |
| 929 | Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 fine sand) mixed with 2% integral water proofing compound laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand) and finished neat etc. complete as per direction of Engineer-in-charge. |
| 930 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board. |
| 931 | Providing and fixing hand rail using structural steel etc. of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete as required:- M.S. tube |
| 932 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 933 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high- pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 934 | Providing and fixing factory made laminated veneer lumber glazed shutter conforming to IS 14616 and TADS 15:2001 (Part B), using 4mm thick float glass panes for doors, windows and clerestory windows including ISI marked black enamelled M.S butt hinges with necessary screws as per direction of Engineer-incharge.30 mm thick shutters |
| 935 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm). |
| 936 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 275mm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters & with handles, hold fast including embedding in cement concrete of required grade required for fixing in position, all necessary fittings, including applying of approved steel primer etc. complete as required:- 80xl.25mm M.S. laths with 1.25 mm thick top cover. |
| 937 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :Gamair Wood 50 × 20 mm |
| 938 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 939 | Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in- Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) |
| 940 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 941 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture. |
| 942 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 943 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm |
| 944 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clampsat 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.15 mm nominal outer dia .Pipes |
| 945 | 25 mm nominal outer dia .Pipes |
| 946 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot&cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling&testing of jointscompleteas per direction of Engineer in Charge. External work32 mm nominal outer dia .Pipes |
| 947 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats complete :15 mm nominal bore |
| 948 | 25 mm nominal bore |
| 949 | Providing and fixing gunmetal gate valve with C.I. wheel of approved quality (screwed end):32 mm nominal bore |
| 950 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi Rigid PVC waste pipe for sink and wash basin 32 mm dia with length not less than 700 mm i/c PVC waste fittingsSemi rigid pipe 40 mm dia |
| 951 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 TypeA including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 952 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592Type-A including jointing with seal ring conforming to IS : 5382 leaving10mm gap for thermal expansionetc. complete as per direction of Engineer-in-charge :Coupler 110 mm |
| 953 | Single pushfit Coupler 110 mm |
| 954 | Bend 87.5° 110mm |
| 955 | Plain shoe 110mm |
| 956 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 957 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms. |
| 958 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore. |
| 959 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 960 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 961 | Providing and laying cement concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mmnominal size) upto haunches of S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe |
| 962 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard designInside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
| 963 | Constructing soak pit 1.20 x 1.20 x 1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design |
| 964 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,PartI.Payment will be made separetly on the basis of actual height based on relevant I.S.Code.For 20 users |
| 965 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 966 | Supply ,Installation and Commissioning of LED Television (49 inch)Full HD (Resolution: 1920 x 1080p), Refresh Rate: 50 hertz, Connectivity - Input: 4xHDMI, 3xUSB, Audio: 10 W output Make: Sony/ LG or equivalent. |
| 967 | Supply & Installation of Lancaster Table & Seating 24\\" x 30\\" Antique Walnut Solid Wood Live Edge Dining Height Table with 4 Chairs |
| 968 | Supply and fitting of one Double-Sided Box-Type Double Bed (Inner Mattress Size: approx. 1.83 m x 1.22 m or 6 ft x 4 ft ), constructed with 18 mm BWP Commercial Plywood for the frame and storage box sides and 12 mm BWP Plywood for the box bottom, fully finished with 0.8 mm thick decorative laminate and PVC/Teak lipping on all exposed edges, featuring a double-sided lift-up storage mechanism and necessary durable hardware, finished complete in all respects as per design and approval. |
| 969 | Supply and fitting of one Three-Seater Fabric Sofa (Overall Dimensions: 2.00 m x 0.90 m x 0.85 mH) with the main internal structure constructed from Chemically Treated and Seasoned Sal Wood / Teak Wood (or equivalent approved hard timber), utilizing high-strength elastic webbing or zigzag springs for durable seat suspension; the seating shall incorporate High-Resilience (HR) PU foam with a minimum density of 40 kg/m^3 for the seat cushions and 32 kg/m^3 foam/Poly-fill for the back cushions; the sofa is to be fully upholstered in Approved Grade Commercial Fabric having a minimum GSM of 350 and a Rub Count of 25,000+, supported by Solid Wood/Stainless Steel Legs, with the rate inclusive of all materials, detailed stitching, finishing, transportation, and complete fixing as per approved sample and design. |
| 970 | Supply and fitting of one Double Door Steel Almirah (Overall Dimensions: 1.98 m x 0.90 m x 0.45 m D) constructed from high-grade CRCA (Cold Rolled Close Annealed) Steel Sheet, with the main body and doors having a minimum thickness of 20 Gauge (1.0 mm), treated via a Seven-Tank Process and finished with a durable Epoxy Polyester Powder Coating (min. 50 micronsb ); the Almirah shall include a secure Three-Way Locking Mechanism, one internal safe/locker box, a hanging rod, and adjustable internal shelving, with the rate being inclusive of all materials, detailed fabrication, finishing processes, transport, and final fixing complete in position. |
| 971 | 28. Construction of Dining & Kitchen for Cottage DistrictEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 972 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 973 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 974 | Treatment of soil under plinth filling using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with sand filling: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 975 | Providing and laying dry flat brick flooring in required pattern complete. |
| 976 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 977 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 978 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 979 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 980 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 981 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 982 | Columns, Pillars, Piers,Abutments, PostsandStrutswith M.S. shutters |
| 983 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 984 | Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 985 | Stairs (excluding landings) except spiral-staircases withwooden plank |
| 986 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 987 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 988 | First class brick work in foundation and plinth including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 989 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 990 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required completeIn cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 991 | Neat cement punning. |
| 992 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 993 | 15mm cement plaster on the rough side of single or half brick wall of mix:Cement mortar 1:4 (1 cement : 4 fine sand) |
| 994 | 12 mm cement plaster of mixCement mortar 1:4 (1 cement : 4 fine sand) |
| 995 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture, of required shade and colour complete, as per manufacurer's specification. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]New work ( two or more coats) over and including waterthinnable priming coat with cement primer. |
| 996 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 1200 mm x 600 mm |
| 997 | Extra for providing and laying Vitrified tiles (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622- 2017, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. all complete as per direction of the Engineer-in-chargeSoluble Salt Stainfree vitrified tiles (Glossy) / Double charged Stainfree vitrified tiles (Glossy) / Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) / Glazed Vitrified Tiles - Full Body (Glossy / Mat Finish/ Anti-Skid) |
| 998 | Providing and fixing chequered terrazo tiles 22 mm thick with graded marble chips of size upto 6 mm, laid on floors, footpath & courtyard on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and polishing etc. all complete as per direction of Engineer-in-charge.Light shade pigment using white cement |
| 999 | Stone tile (polished) work for wall lining over 12mm thick bed of cement mortar 1:3 (1 cement : 3 fine sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete including rubbing, curing etc. complete at all levels as required:-Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble or equivalent duly aproved. |
| 1000 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board. |
| 1001 | Providing and fixing hand rail using structural steel etc. of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete as required:- M.S. tube |
| 1002 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 1003 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high- pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 1004 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm) |
| 1005 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified and as per direction of Engineer-in-charge. 2mm thick flat |
| 1006 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass (weight not less than 10ks/Sqm) panes including black enamelled ISI marked MS butt hinges with necessary screws.Local Teak wood 35 mm thick |
| 1007 | Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, window and clereslory window shutters (Area of opening of glass panes excluding portion inside rebate shall be measured) |
| 1008 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :Gamair Wood 50 × 20 mm |
| 1009 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 1010 | Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in- Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be madeFixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) |
| 1011 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture. |
| 1012 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm |
| 1013 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clampsat 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc.15 mm nominal outer dia .Pipes |
| 1014 | 25 mm nominal outer dia .Pipes |
| 1015 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stabilityfor hot&cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling&testing of jointscompleteas per direction of Engineer in Charge. External work25 mm nominal outer dia .Pipes. |
| 1016 | 32 mm nominal outer dia .Pipes |
| 1017 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats complete :15 mm nominal bore |
| 1018 | 25 mm nominal bore |
| 1019 | Providing and fixing gunmetal gate valve with C.I. wheel of approved quality (screwed end):32 mm nominal bore |
| 1020 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi Rigid PVC waste pipe for sink and wash basin 32 mm dia with length not less than 700 mm i/c PVC waste fittingsSemi rigid pipe 40 mm dia |
| 1021 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 TypeA including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 1022 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592Type-A including jointing with seal ring conforming to IS : 5382 leaving10mm gap for thermal expansionetc. complete as per direction of Engineer-in-charge :Coupler 110 mm |
| 1023 | Single pushfit Coupler 110 mm |
| 1024 | Bend 87.5° 110mm |
| 1025 | Plain shoe 110mm |
| 1026 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 1027 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms. |
| 1028 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore. |
| 1029 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 1030 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 1031 | Providing and laying cement concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mmnominal size) upto haunches of S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe |
| 1032 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks in cement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard designInside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
| 1033 | Constructing soak pit 1.20 x 1.20 x 1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design |
| 1034 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,PartI.Payment will be made separetly on the basis of actual height based on relevant I.S.Code.For 20 users |
| 1035 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 1036 | Providing, fabricating and erecting designer architectural roof shed, having sculptural curved / sloping profile as per approved architectural concept, comprising primary and secondary structural framework in structural steel / MS sections including rafters, purlins, brackets, connectors and stiffeners, complete with anti-corrosive treatment (zinc primer / epoxy primer and finishing coat). Over the framework, engineered timber / treated wooden battens or laminated members shall be fixed in inclined / radial pattern for architectural expression, finished with exterior-grade weather-resistant PU / melamine coating. The roofing shall be completed with high-quality pre-painted polycarbonate roof sheets (as approved), fixed over purlins with self-drilling fasteners, EPDM washers, laps, ridge pieces, flashing, gutters, drip edges and necessary waterproofing arrangements, ensuring complete weather tightness. Item includes anchoring to RCC / stone / masonry supports, integration with façade elements, scaffolding, lifting, alignment, levelling, safety provisions, protection during execution, and all materials, labour, tools, transportation and incidentals, complete in all respects as per approved drawings, structural design and directions of Engineer-in-Charge. |
| 1037 | Supply and fitting of one complete 4-Seater Dining Table and Chair Set (Table Dimensions: approx. 1.20 m L×0.75 m W×0.75 m H), with the structure and legs of both the table and the four chairs constructed from Chemically Treated and Seasoned Hardwood (e.g., Sheesham/Rubberwood); the tabletop shall feature a durable finish (such as 1.0 mm thick decorative laminate on BWP Plywood or solid hardwood), and the four matching chairs shall incorporate an 40 mm thick High-Density PU Foam seat cushion upholstered in durable Commercial Fabric or PU Leatherette; the entire set is to be finished with a durable Melamine or Polyurethane (PU) Polish/Finish, with the rate being inclusive of all materials, detailed fabrication, finishing, upholstery, transport, and final installation complete in position. |
| 1038 | Supply and fitting of one complete 6-Seater Dining Table and Chair Set (Table Dimensions: approx. 1.80 m L×0.90 m W×0.75 m H), with the structure and legs of both the table and the six chairs constructed from Chemically Treated and Seasoned Hardwood; the tabletop shall feature a durable finish (such as 1.0 mm thick decorative laminate on BWP Plywood or solid hardwood), and the six matching chairs shall incorporate a 40 mm thick High-Density PU Foam seat cushion upholstered in durable Commercial Fabric or PU Leatherette; the entire set is to be finished with a durable Melamine or Polyurethane (PU) Polish/Finish, with the rate being inclusive of all materials, detailed fabrication, finishing, upholstery, transport, and final installation complete in position. |
| 1039 | 29. Construction of Boating AccessoriesProviding and constructing a waterside angling deck using structural steel frame, suitable for boating and fishing activities. The work includes site preparation, installation of steel piles or supports anchored into the waterbed, fabrication and erection of steel beams and girders, and fixing of treated timber or composite wood decking with anti-slip surface. The deck shall have steel railings with toe-boards along the perimeter, seating benches, fishing rod holders, and mooring provisions for small boats. All steel members shall be treated with anti-corrosive paint, and timber surfaces treated for water resistance and durability. The work shall include excavation, hoisting, fasteners, jointing, temporary scaffolding, safety measures, and complete site cleanup. The rate shall cover all materials, labor, tools, and equipment required for full execution as per approved drawings and specifications. |
| 1040 | Providing and supplying a 4-seater recreational paddle boat, made of high-quality, UV-stabilized, water-resistant fiberglass or high-density polyethylene (HDPE), suitable for safe boating in lakes, ponds, or waterside parks. The boat shall be equipped with corrosion-resistant pedals, steering system, comfortable seating for four persons, and safety features including life jackets and non-slip floor. The work includes transportation to site, placement at designated launching area, assembly (if required), inspection, and demonstration for safe operation. The boat shall be finished with weather-resistant coating and designed to withstand prolonged exposure to sun and water, ensuring durability and low maintenance. |
| 1041 | Providing and supplying a 2-seater recreational boat made of high-quality, UV-stabilized, water-resistant fiberglass or high-density polyethylene (HDPE), suitable for boating in lakes, ponds, or waterside parks. The boat shall include corrosion-resistant pedals or paddles, steering mechanism, comfortable seating for two persons, and safety provisions such as life jackets and non-slip flooring. The work includes transportation to site, placement at designated launching area, assembly (if required), inspection, and demonstration for safe operation. The boat shall be finished with weather-resistant coating, designed for durability and minimal maintenance under continuous water exposure |
| 1042 | 30.Construction of PiscicultureDesign, supply, transportation, installation, anchoring, testing and commissioning of HDPE Floating Fish Caging System suitable for reservoirs and inland water bodies complete in all respects. The system shall comprise UV-stabilized HDPE floating blocks/pontoons of approved make, interconnected with hot-dip galvanized / stainless steel fasteners to form a stable floating base. The item shall include anti-skid walkways, safety lifelines, feeding arrangement and anchoring system comprising mooring ropes, chains, shackles and concrete anchor blocks suitable for water level fluctuation and current conditions of Tripura reservoirs. All materials shall be non-toxic, corrosion-resistant and suitable for continuous freshwater immersion. The rate shall include all materials, labour, transportation (including remote locations), installation, launching, positioning and incidentals, complete as per standard aquaculture practice and directions of Engineer-in-Charge. |
| 1043 | Design, supply, transportation, installation and commissioning of Fish Cage Enclosure System, complete in all respects for inland reservoirs.The item shall include knotless HDPE/nylon netting of approved mesh size comprising inner rearing net, outer predator protection net and bottom net, fixed with UV-resistant nylon ropes, clips and fittings. The rate shall include all materials, labour, transportation, installation, fixing, launching support and all incidental works, complete as per standard aquaculture practice and directions of Engineer-in-Charge. |
| 1044 | 31. Construction of Drainage SystemEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 1045 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 1046 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 1047 | Providing and laying dry flat brick flooring in required pattern complete. |
| 1048 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 1049 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 1050 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 1051 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 1052 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 1053 | Neat cement punning. |
| 1054 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 1055 | chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipeline with three or more inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1056 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.180x150 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 1057 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930. Part lI complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.200 mm dia (OD-200 mm & ID-175 mm nominal' |
| 1058 | 90 mm dia (OD-90 mm & ID-76 mm nominal) |
| 1059 | 32. Sinking of Mini Deep tubewell (5 nos.)Drilling and boring pilot hole in any soil strata by manual means, collection of soil samples of different strata met with during drilling at variuse suitable levels, preservation of samples in polythene bags/ sample box and disposal of excess soil or mud, including the cost of water etc, as required to mantain the pilot hole properly as per specification and direction of the Engineer-in charge. i) 100mm dia |
| 1060 | Reaming of pilot hole to an enlarged bore hole in any soil strata by manual means,disposal of excess soil or mud, including the cost of water etc, as required to maintain the pilot hole properly as per specification and direction of the Engineer-in charge. i) From 100mm dia pilot hole to 250mm bore hole |
| 1061 | Providing and lowering of PVC pipe of UPVC pipe as per IS:12818 after washing of the bore hole by manual means as per specification and direction of the Engineer-incharge. A) CM Casing pipe (UPVC)i) 150mm dia |
| 1062 | ii) 100mm dia |
| 1063 | A) RS pipeii) 100mm dia |
| 1064 | Washing and development of tube well by using hand pump or by any suitable method and testing of the well as per pecification and direction of the Engineer in charge |
| 1065 | Providing and shrouding of the deep tube well assembly with washed pea gravels (2.0 - 4.75 mm effective size) as per specification (IS: 4097) and direction of the Engineer in charge. A) With contractor rigi) with pea gravels obtained from Durgapur, West Bengal |
| 1066 | Providing and fixing of UPVC end cap/ well cap suitable for UPVC 'CM' casing or 'CS' casing or RS pipe as per specification and direction of the Engineer in chargei) 100mm dia |
| 1067 | Providing and fitting fixing GI pipe (Medium class) conforming to IS 1239 for column pipe assemble for instalation of submersible pump motor as per direction of Engineer in charge.d) 40mm NB |
| 1068 | Providing and fitting fixing GI bend/ elbow in the pipe line including testing of joints complete as per CPWD specification and direction of Engineer in charge.v) 40mm NB |
| 1069 | Providing and fitting fixing of GI flange (10mm wall thickness) by welding with GI/ MS pipe as per placing position as per specification and the direction of Engineer in charge.vi) 50mm dia |
| 1070 | Providing and fitting fixing of C.I. non return valve of approved quality as per CPWD pecification and the direction of Engineer in charge.i) 50mm nominal bore |
| 1071 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) |
| 1072 | Installation of submerssible pump and suitable motor upto requirede depth with GI column pipe in/c providing fitting fixing by necessaqry rubber washer , nuts & bolts, Ms safety clamp etc. As per required size and making necessary electrical connection with main switch/starter with motor in/c commissioning & trial run as per direction of the Engineerin charge (pump, motor with cable, GI Pipe will be issued by the Department at free of cost and fabrication of GI column pipe will be paid separately).i. 2500 GPH capacity |
| 1073 | Providing 2 HP submerssiblepump as per direction of Engineer in charge |
| 1074 | Providing and fixing of UPVC reducer suitable for UPVC 'CM' casing or 'CS' casing or RS pipe as per specification and direction of the Engineer in charge. i) 150 x 100mm dia |
| 1075 | 33. Construction of Water Tank & Water supplyEarth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 1076 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.All kinds of soil |
| 1077 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 1078 | Providing and laying dry flat brick flooring in required pattern complete. |
| 1079 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 1080 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 1081 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 1082 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 1083 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns etc. for mass concrete with steel formwork |
| 1084 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 1085 | Columns, Pillars, Piers,Abutments, Post sand Struts with M.S. shutters |
| 1086 | Suspended floors, roofs, landings, balconies and access platform with M.S. plates and props |
| 1087 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 1088 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 1089 | First class brick work In superstructure above plinth level & upto floor-five level including cost of all materials as required complete:In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 1090 | 20 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 1091 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 1092 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 1093 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 1094 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/ system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 1095 | Supplying, fitting and fixing cast iron heavy type spiral staircase of approved design with 50 mm.dia. Stem and C.I. Steps 150 mm as per design 900 mm. high C.I, railing including necessary M.S. tie of suitable section embedded to wall with cement concrete (1:2:4) including cost of intermediate C.I. platform secured with necessary tie to stem and wall with cement concrete (1:2:4) including fixing the stem in ground with cement concrete (1:3:6) complete in all respect with all labour and materials. |
| 1096 | WATER SUPPLY & DISTRIBUTIONProviding and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 1097 | Providing and fixing G.I. pipes of medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling etc. complete as per CPWD specification and direction of the Engineer - in - charge.19.12.8 80 mm dia. nominal bore |
| 1098 | 19.12.6 50 mm dia. nominal bore |
| 1099 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conforming to IS : 13592 TypeA including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc. complete as per direction of Engineer-in-charge :Single socketed pipe - 110 mm OD |
| 1100 | Providing and fixing on wall face unplasticised-PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592Type-A including jointing with seal ring conforming to IS : 5382 leaving10mm gap for thermal expansionetc. complete as per direction of Engineer-in-charge :Coupler 110 mm |
| 1101 | Single pushfit Coupler 110 mm |
| 1102 | Single equal tee without door 110x110x110mm |
| 1103 | Single equal tee with door 110x110x110mm |
| 1104 | Bend 87.5° 110mm |
| 1105 | Plain shoe 110mm |
| 1106 | 34. Construction of Watch Tower cum Zip StationEarth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 1107 | Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work as per MoRT&H Technical Specification clauses of section 300.Ordinary SoilBy manual means ( upto 3 m depth ) |
| 1108 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 1109 | Providing and laying dry flat brick flooring in required pattern complete. |
| 1110 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level 1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 20 mm nominal size) |
| 1111 | Providing and laying in position ready mixed concrete manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of RMC from transit mixer to site of laying but excluding the cost of centring, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per the direction of Engineer-in-Charge. (Note :- Cement content considered in this item is @ 418 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately)All Works upto Plinth LevelReinforced cement concrete grade M-25 using 418 kg of cement per cum |
| 1112 | Extra for providing richer mixes at all floor levels.Providing M-30 grade of concrete instead of M-25 grade of concrete B.M.C/R.M.C |
| 1113 | All works upto Floor five level Reinforced cement concrete grade M-25 using 418 kg of cement per cum |
| 1114 | Extra for providing richer mixes at all floor levels.Providing M-30 grade of concrete instead of M-25 grade of concrete B.M.C/R.M.C |
| 1115 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 1116 | Centering shuttering including struttings, propping etc. and removal of form work for:Foundations, footings, bases for columns. |
| 1117 | Columns, piers, abutments, pillaras, posts and struts |
| 1118 | First class brickwork in superstructure above plinth level & upto floor-five level including cost of all materials as required complete: In cement mortar 1:4 ( 1 cement : 4 fine sand ) |
| 1119 | 15 mm cement plaster on the rough side of single or half brick wall of mix Cement mortar 1:6 (1 cement : 6 fine sand) |
| 1120 | Chipping of unsound/weak concrete material from slabs,beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge.25 mm average thickness |
| 1121 | Providing and fixing Kota stone in floors over 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand) jointed with ordinary cement slurry including pointing with ordinary cement mixed with pigment of matching shade, including rubbing and polishing etc. all complete as per direction of Engineer-in-charge.Kota stone slab 25mm thick |
| 1122 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622- 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge..Double charged Stainfree vitrified tiles (Glossy) |
| 1123 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives as per manufacturers specifications [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 1124 | Providing and fixing handrail using structural steel etc. of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete as required:1. M.S. tube |
| 1125 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes |
| 1126 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 1127 | Aluminium Composite Panels of 3mm total thickness with Top coil– 0.25mm AA3003 Grade manufactured as per IS-737 1986, FR Grade Class B1 with 2.50mm Mineral Core with minimum 70-72% Inorganic content (Aluminium Hydroxide and Magnesium Hydroxide) 28 30% Organic content (LDPE) conforming to ASTM E-119 16,18 and EN 13501- 1 class B1 and Bottom coil 0.50mm AA3003 Grade manufactured as per IS-737 1986 with minimum 25 microns lead free PVDF Coating conforming to AAMA2605 on top coil and Service coating on Back Coil (4- 6 microns) having minimum panel weight of 5.25 Kg/m2 |
| 1128 | Supply, installation, testing and commissioning of a complete Zip Line System comprising high-strength 12 mm dia galvanized steel wire rope (6×19 steel core) conforming to ISO standards, including all end terminations such as bull grip clamps, ferrules, thimbles, pulley wheels, bow shackles, and jaw-to-jaw open type turnbuckles for proper tensioning and alignment. The system shall include zip line brake trolley / impact trolley (UIAA certified) suitable for 12 mm rope, designed for controlled deceleration and safe landing, with load capacity not less than 150 kg (330 lbs). The item shall also include suspension brake arrangement, anchoring system with self-anchor I-sling, and all necessary fittings, fixtures, fasteners, and accessories required to make the zip line fully operational. Complete installation shall be carried out as per approved design, OEM recommendations, and applicable international safety standards, including load testing, trial runs, and commissioning, complete in all respects. |
| 1129 | Supply of complete Zip Line Safety Accessories and Personal Protective Equipment (PPE) comprising sit harness (EN 12277 Type C / UIAA 105 certified) made of high-strength polyester, safety helmet (EN 12492 / UIAA 106 certified) with adjustable size, alloy screw carabiners (EN 12275 / EN 362), steel oval carabiners (EN 362), Y-lanyard (EN 17520), single rope pulley (EN 12278 certified) suitable for 12–13 mm rope, static rope (12 mm dia), protective gloves / mittens, and other compatible connectors and safety components as specified. All accessories shall be of reputed make, conforming to international safety standards, suitable for commercial zip line operation, complete in all respects and ready for use |
| 1130 | 35. ELECTRIFICATION WORKSSupplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required250 amps TPN 415 volts front handle cubical main switch (HRC) |
| 1131 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required300 amps 415 volts four strip Copper busbar chamber 6 ways of size (610mmx410mmx150mm):- |
| 1132 | Supplying and installation of Automatic Transfer Switch (ATS) of following the ratings with enclosure along with UV/OV protection controller including necessary connections etc. as required200 amps Four Pole ATS : - |
| 1133 | Design, Manufacturing, Supply, Installation, Testing & Commissioning of Feeder Pillar Box, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed with canopy, IP 54, leg mounting,outdoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering & protection instruments, earthings and following accessories in the FPB as per given outgoing details (Switchgear: L&T, ABB, Legrand, Schneider) There will be provision for manual overwrite with auto manual selector switch.INCOMER1 No. 63A, FP MCB Isolator & 63 Amp FP Power Contactor and other connecting accessories.BUSBARS1 Set of 415 V, 63A/80A , 3-Ph ,50Hz, FOR 1 SEC. busbars of high conductivity electrolytic quality Copper. (Cross section should not be less than 20mmx3mm)INSTRUMENTS1 No. 0 to 415 Volt digital voltmeter for 3 phase, 4 wire operation with LED display and selector switch for On, Off, Trip indication lamp. Digital time switch similar to make should be there for controlling of street lights1 Set of phase(R/Y/B) indicating lamps, LED typeOUTGOING |
| 1134 | Design, Manufacturing, Supply, Installation, Testing & Commissioning of Feeder Pillar Box, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed with canopy, IP 54, leg mounting,outdoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering & protection instruments, earthings and following accessories in the FPB as per given outgoing details (Switchgear: L&T, ABB, Legrand, Schneider) There will be provision for manual overwrite with auto manual selector switch.INCOMER1 No. 100 A, FP MCB Isolator & 63 Amp FP Power Contactor and other connecting accessories.BUSBARS1 Set of 415 V, 100/125 A , 3-Ph, 50Hz, FOR 1 SEC. busbars of high conductivity electrolytic quality Copper. (Cross section should not be less than 20mmx3mm)INSTRUMENTS1 No. 0 to 415 Volt digital voltmeter for 3 phase, 4 wire operation with LED display and selector switch for On, Off, Trip indication lamp. Digital time switch similar to make should be there for controlling of street lights1 Set of phase(R/Y/B) indicating lamps, LED typeOUTGOING1. 8 nos. 16/20 A DP MCB Isolator which feed power directly to the internal wiring circuit without any timmer circuit . 2. 8 Nos. 16A DP MCB with digital timmer. 3. 2 No. of 40 A FP MCB. |
| 1135 | Design, Manufacturing, Supply, Installation, Testing & Commissioning of Feeder Pillar Box, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed with canopy, IP 54, leg mounting,outdoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering & protection instruments, earthings and following accessories in the FPB as per given outgoing details (Switchgear: L&T, ABB, Legrand, Schneider) There will be provision for manual overwrite with auto manual selector switch.INCOMER1 No. 100 A, FP MCB Isolator & 100 Amp FP Power Contactor and other connecting accessories.BUSBARS1 Set of 415 V, 125 A , 3-Ph, 50Hz, 25KA FOR 1 SEC. busbars of high conductivity electrolytic quality Copper. (Cross section should not be less than 20mmx3mm)INSTRUMENTS1 No. 0 to 415 Volt digital voltmeter for 3 phase, 4 wire operation with LED display and selector switch for On, Off, Trip indication lamp. Digital time switch similar to make should be there for controlling of street lights1 Set of phase(R/Y/B) indicating lamps, LED typeOUTGOING1. 5 nos. 20/32 A DP MCB Isolator which feed power directly to the internal wiring circuit without any timmer circuit. 2. 5 Nos. 16A DP MCB with digital timmer. 3. 2 Nos. 40 A FP MCB without timmer. |
| 1136 | Design, Manufacturing, Supply, Installation, Testing & Commissioning of Feeder Pillar Box, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed with canopy, IP 54, leg mounting,outdoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering & protection instruments, earthings and following accessories in the FPB as per given outgoing details (Switchgear: L&T, ABB, Legrand, Schneider) There will be provision for manual overwrite with auto manual selector switch.INCOMER1 No. 160 A, FP MCB Isolator & 160 Amp FP Power Contactor and other connecting accessories.BUSBARS1 Set of 415 V, 125 A , 3-Ph, 50Hz, 25KA FOR 1 SEC. busbars of high conductivity electrolytic quality Copper. (Cross section should not be less than 20mmx3mm)INSTRUMENTS1 No. 0 to 415 Volt digital voltmeter for 3 phase, 4 wire operation with LED display and selector switch for On, Off, Trip indication lamp. Digital time switch similar to make should be there for controlling of street lights1 Set of phase(R/Y/B) indicating lamps, LED typeOUTGOING1. 3 nos. 20/32 A DP MCB Isolator which feed power directly to the internal wiring circuit without any timmer circuit. 2. 2 Nos. 16A DP MCB with digital timmer. 3. 4 Nos. 63/40 A FP MCB without timmer. |
| 1137 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way , Double door |
| 1138 | Supplying and fixing 5 A to 32 A rating, 240 V , 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 1139 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amp |
| 1140 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 1141 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required3 x 1.5 sq. mm [ for 2X6 Amp Separate Socket ] |
| 1142 | 3 x 2.5 sq. mm [ For Computer Board & 2X16 Amp separate Socket ] |
| 1143 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 1144 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.8 Module (125mmX125mm) [ For 2X6 & 2X16 A ] |
| 1145 | 12 Module (200mmX150mm) [ For Computer Board ] |
| 1146 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet |
| 1147 | 5/6 A switch |
| 1148 | 6 pin 15/16 A socket outlet |
| 1149 | 15/16 A switch |
| 1150 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes1.5 sq mm |
| 1151 | 2.5 sq mm |
| 1152 | 4 sq. mm |
| 1153 | 6 sq. mm |
| 1154 | 10 sq mm |
| 1155 | 16 sq mm |
| 1156 | Supply & delivery of one no. of cables of 4 core 95 sqmm AL, XLPE Armoured ( Make -Polycab/RR Cable/Finolex or equivalent )(NS) ( for to Meter to Main Switch & Main Switch to Busbar) |
| 1157 | Supply & delivery of one no. of cables of 4 core 50 sqmm AL, XLPE Armoured ( Make - Polycab/RR Cable/Finolex or equivalent )(NS) ( from LT Panel to Feeder-Pillar Box) |
| 1158 | Supply & delivery of one no. of cables of 4 core 25 sqmm AL, XLPE Armoured ( Make - Polycab/RR Cable/Finolex or equivalent )(NS) ( from BUSBAR to Feeder-Pillar Box) |
| 1159 | Supplying and Delivery of following sizes XLPE insulated PVC sheathed Aluminium conductor Un-armoured cable including necessary connection etc as required. 2 core 6 Sq mm |
| 1160 | 2 core 4 Sq mm |
| 1161 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm |
| 1162 | Above 35 sq. mm and upto 95 sq. mm |
| 1163 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 1164 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm dia |
| 1165 | 80 mm dia |
| 1166 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. [ Ref :- DSR-202/Item-1.25/Page-6] |
| 1167 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 1168 | Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. |
| 1169 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.] |
| 1170 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 1171 | PROVIDING AND FIXING CIRCULAR/ HEXAGONAL G.I. BOX FOR CEILING FAN CLAMP, OF INTERNAL DIA 140 MM, 73 MM HEIGHT, TOP LID OF 1.5 MM THICK G.I. SHEET WITH ITS TOP SURFACE HACKED FOR PROPER BONDING, TOP LID SHALL BE SCREWED INTO THE G.I. BOX BY MEANS OF 3.3 MM DIA ROUND HEADED SCREWS, ONE LOCK AT THE CORNERS. CLAMP SHALL BE MADE OF 12 MM DIA M.S. BAR BENT TO SHAPE AS PERSTANDARD DRAWING. |
| 1172 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 1173 | Supplying & installation of 400 mm sweep AC wall mounting fan with metal blade including connection etc as required |
| 1174 | Surface mounted integrated 10 watt LED batten with polycarbonate diffuser:- |
| 1175 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
| 1176 | Supplying and fixing of BOLLARD (MOUNT LED BOLLARD- Havells , Model - MOUNTBL10WLED830PSYMTOPMMAM) incl. all necessary connections. |
| 1177 | Supplying and fixing of 45 W Street Light incl. all necessary connections .[ Ref :- TRIPURA SCHEDULE OF RATES-2021/Item-1102/Page-36 ] |
| 1178 | Supplying and fixing of LED Spot Light (Make :- Havells, Model - LED Duospot Surface Round WHT 10 W 3000 K) incl. all necessary connections. |
| 1179 | Supplying and fixing of 36 W Hanging LED fittings (Make - Crompton, Model No - LCSUR4-36-CDL) incl. all necessary connections. |
| 1180 | Supplying and fixing of 25 W POST TOP (Make - Havells, Model No - RUBYPT25WLED757SSYMTOPC) incl. all necessary connections. |
| 1181 | Supplying and fixing of 50 W Posttop Light (Make - Havells ,Model - JUPITERMAXIPT50WLED830PSYMTOPC) incl. all necessary connections. |
| 1182 | Supplying and fixing of Post-top Light 70W ( Make - Havells, Model -TYCOONPT70WLED757PSYMTOPC) incl. all necessary connections. |
| 1183 | Supplying and fixing of SURFACE PANEL LED Fittings (Havells -TRIM CLICK FIX SURFACE PANEL ROUND --LHEABIP5IL1W012) incl. all necessary connections. |
| 1184 | Supplying and fixing of 3 W Spot LED Fittings ( Make - Havells, Model - LUNA LED JB DOWNLIGHT(LHEBAZP5UZ1W003)) incl. all necessary connections. |
| 1185 | Supplying and fixing of 15 W SPIKE LIGHT (Make :- Havells, Model - LYCUSSPS15WLED730PSYMBOTG) incl. all necessary connections. |
| 1186 | Supplying and fixing of UP-down WALL LIGHT (Make :- Havells , Model - CLIOWLS15WLED830PSYMTOTG) incl. all necessary connections. |
| 1187 | Supplying and fixing of 40W Solar Street Light (Bajaj, Model - SUNSOKO AIO BSZSL 60L - HYB) incl. all necessary connections. |
| 1188 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt)80 watt LED flood light fixture with integral driver and secondary lens (IP 66):- |
| 1189 | 120 watt LED flood light fixture with integral driver and secondary lens (IP 66):- |
| 1190 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required25 mm dia |
| 1191 | Supplying Delivery of 6mtr. Decorative Pole ( Make- Havells, Model - DECO POLE 6M TOP Ø 76 MM) with all necessary arrangements. |
| 1192 | Supply of 6 MTRS GI OCTAGONAL POLE FABRICATED PART AS PER DIMENSION :T0P DIA - 70 mm, BOTTOM DIA -130 mm, (SECTION LENGTH - 6000 mm) THICKNESS - 3 mm,BASE PLATE - 220 mm x 220 mm x 12 mm.. FOUNDATION BOLT - M20 x 600 mmx 4 nos 'J' type bolts [ Make :- Utkarsh Pole/Subham Pole/Bajaj Poles/Transrail] |
| 1193 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required Above 4.5 metre and upto 6.5 metre |
| 1194 | Supply & Delivery of 10.0 mtr. Long 3 mm thick Octagonal Poles incl all necessary arrangements and Ring Type Bracket for fixing 8 nos. of Flood Light Fittings. (Make: Bajaj / Transrail / Valmond/Utkarsh /Skipper) |
| 1195 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 1196 | Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting 250 x 250 x 100mm |
| 1197 | Supplying & installation of 300 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked) :- [ Ref :- TRIPURA SCHEDULE OF RATES-2021/Item-818/Page-33 ] |
| 1198 | Extra for fixing the louvers/ shutters complete with frame for aexhaust fan of all sizes. [ Ref :- DSR-2022/Item No - 1.50/Page-8 ] |
| 1199 | 36. Air Conditioning SystemSupply , Installation, Testing and Commissioning of Air Cooled Hi Wall splittype Air conditioners complete with Indoor unit(IDU), Out door unit (ODU),surface / concealed copper Refrigerant piping with insulation (closed cellelastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU),copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for workingbetween 180-260V with low & high voltage cutoff and 50 hz ,1 phase ACsupply capable of performing cooling, dehumidification, air circulation offollowing capacity with Scroll / rotary compressor. The system shall be ableto deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 yearOriginal Equipment Manufacturer (OEM) warranty both compressor andPrinted Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS9968 temperature sensing control IS /International Electro technicalCommission (IEC) 60730, hermetic compressor IS 10617, heat exchangerIS 11329, capacitor IS 2993 and motor IS 12615. The system shall be able to operateup to 50 0C (out door ambient temperature). (Make:- As approved by the concern authority)2.0 TR with 5 Star BEE Rating (Inverter Type - Cooling only |
| 1200 | Supply & Laying of soft drawn Copper pipe line with 0.6 mm or 0.7 mm (min) thick for Liquid Line and Suction Liine between ODU and IDU with fittings, elbows, bends, supports & brackets (Make-Ryoku/Hitachi/Nippon) [ For additional work as or where required ]Liquid Line 1/4\\" (6.35mm) Dia or as per manufacturer specification) |
| 1201 | Gas Line/Suction Line 5/8\\" (15.88mm) Dia or as per manufacturer specification) |
| 1202 | Supply & Fixing Pipe Insulation of Liquid Line and Suction Liine with 9 mm thick nitrile rubber tube also raping the insulation & copper wire with GKB Gold non adhesive raping tape (Make:- Accoflex/ Armacell/Supreme)Liquid Line 1/4\\" (6.35mm) Dia or as per manufacturer specification) |
| 1203 | Gas Line/Suction Line 5/8\\" (15.88mm) Dia or as per manufacturer specification) |
| 1204 | Supply and laying 4 core 2.5 sq mm control copper cable (PVC insulated & unshethed,un-armoured) from Condensing Unit to IDU control panel. (Make: Gloster/Havells/RR Kable /Finolex/ Polycab) [ For additional work as or where required ] |
| 1205 | Supply and laying of Drain Water piping work out of UPVC hard pipes of following sizes incl. nitrile insulation with fiting accessories bends, elbows, tees flanges, tapings, wall sleeves hangers, supports, anchors etc. as required.(Make : Supreme / Astral/ EIC approved).25 mm dia. |
| 1206 | Hiring Charge of Scafolding Arrangements for installation of all the Indoor & Outdoor Units. |
| 1207 | Supply and fixing of 25 A OLP 3+ AC Starter(Make: Electron) on 4 module GI board inclusive necessary connection as per direction of EIC [N.S] |
| 1208 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 1209 | Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32 A 240 V \\"C\\" curve DP MCB complete withconnections, testing and commissioning etc. as required. |
| 1210 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 4 sq. mm [ For AC Work ] |
| 1211 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: 4 sq. mm |
| 1212 | 37. DG SETSupply, installation, Testing & Commissioning of 'Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings:(A) Diesel Engine:Turbocharged Diesel engine 4 stroke water cooled, multi cylinder,dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all therequired accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.(B) Engine mounted Instrument Panel fitted with and having digital display for following :- (i) Start-stop switch with key. (ii) Water temperature indication. (iii) Lubrication oil pressure indication. (iv) Lubrication oil temperature indication. (v) Battery charging indication and Voltage indication. (vi) RPM indication. (vii) Over speed indication. (viii) Low lubricantion Oil trip indication. (ix) Engine Running Hours indication. (x) Fuel Level. (C) Alternator :Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame & Foundation :Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(E) FUEL TANK :Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.(F) Exhaust System :Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System :12V/24V DC starting system comprising of starter motors: voltageregulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.(I) AMF Panel:Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminum) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following :- (I) AMF Panel:Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminum) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set includingconnection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following :- 1. Suitable numbers and appropriate capacity 4 pole motorisedelectrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch.3. Protection for under and over voltage phase reversal (2 nos Overvoltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering.5. Energy analyser unit to indicate current, Voltage( L-N & L-L), kW, kVA (Phase & Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set.7. Fuse/ MCB for instruments.8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor.10. Supply failure timer.11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator.15. Audio/Video annunciation for ----(i) High water temperature, (ii) Low lubricating oil pressure. (iii) Engine over speed. (iv) Engine fails to start. (v) Full load/ maximum load warning.16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories17. Maintenance notification based on Engine Run Hour & due date.18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel, interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.200 KVA |
| 1213 | 38. CCTV systemSITC of 2MP IP Dome Camera , Infrared 1080p FHD, Night Vision, HD Resolution, Image Sensor, Connectivity Technology: Wireless, Connectivity Protocol: RTSP, Controller Type: Android, ios, Ceiling Mount, [Detail Specifications: 1/2.7” 2MP PS CMOS Image Sensor 3.6MM Lens, 25/30 fps@ Resolutin: 1080P (1920×1080), DWDR, Day/Night(ICR), 3D-DNR, ROI, AWB, AGC, BLC, HLC, IR Range of 30 Mtrs, IP67, PoE, H.265+ / H.265 dual-stream encodingwith.] Including all fixing accessories.(Make: CP Plus/ Hikvision/ Dahua/ equivalent as per EIC choice.) |
| 1214 | SITC of 2 MP + IP Bullet Camera + Night Vision Outdoor IR Camera: 30 Mtr. with 3.6mm Fixed Lens. [Detail Specifications: operating- Android and iOS , Can Be Watched Online, High Quality Branded Product, Easy to install, Night Vision : See crystal clear, black & white images even in complete darkness with Infra-Red LEDs, with CMOS Image Sensor for better and crisp picture quality, Smart IR Cut Filter, Up to 30m IR distance. including H.265+ & H.264+ dual-stream encoding, Max. 25/30fps@ Resolutin: 1080P (1920×1080) Full HD, 3.6mm fixed lens (2.8mm optional),DWDR, Day/Night(ICR), 3D-DNR, ROI, EIS, AWB, AGC, BLC, HLC,IR Range of 30 Mtrs, IP67, PoE,Mobile Software: iCMOB, gCMOB, CMS Software: KVMS Pro, Ceiling/ Wall Mount, viewing angle range: upto 84 deg, ] Including all fixing accessories. (Make: CP Plus/ Hikvision/ Dahua/ equivalent as per EIC choice.) |
| 1215 | SITC of 32 Channel. H.265 4K Network Video Recorder (NVR), Industrial-grade embedded processor, [Detail Specifications: User Interface: Web; local GUI, Video Output: 1-ch VGA output and 1-ch HDMI output; simultaneous/ heterogeneous video sources output for VGA and HDMI is configurable, Resolution : 16MP; 12MP; 8MP; 5MP; 4MP; 3MP; 2MP; 720P; D1, Video Compression : H.265/Smart H.264+/H.264/MJPEG, Encode Strategy : Instastream, Video Display Split : 1st Screen: 1/4/8/9/16/25/36 ; 2nd Screen: 1/4/8/9, Audio Compression : PCM; G.711A; G.711U; G.726, Decoding Capability : AI off: 1 channel × 16MP@20fps; 1 channel × 12MP@20fps; 2 channels × 8MP@30fps; 4 channels × 5MP@30fps; 5 channels × 4MP@30fps; 10 channels × 1080p@30fps AI on: 1 channel × 16MP@20fps; 1 channel × 12MP@20fps; 2 channels × 8MP@30fps; 3 channel × 5MP@30fps; 4 channels × 4MP@30fps ; 8 channels × 1080p@30fps, Hard Disk : 4 SATA ports, up to 10 TB. The maximum HDD capacity varies with environment temperature, operating- Android and iOS, Playback: Play, pause, stop, fast forward, fast backward, rewind, play by frame, Full screen, backup (cut/file), partially enlarge, audio on/off, Ethernet: 2 RJ-45 10/100/1000 Mbps self-adaptive, Interface Ports: 1 front USB 2.0 port, 1 rear USB 3.0 port , 1 RS485, 1 RS232, Protocols: HTTP; HTTPS; TCP/IP; IPv4/IPv6; UPnP; SNMP; RTSP; UDP; SMTP; NTP; DHCP; DNS; IP Filter; PPPoE; DDNS; FTP; Alarm Server; IP Search; InstaOn; auto register; ONVIF (profile T/S/G); CGI; SDK] Including all fixing accessories. (Make: CP Plus/ Hikvision/ Dahua/ equivalent as per EIC choice.) |
| 1216 | SITC of 24 port Power Over Ethernet (POE) Switches. [Detail Specifications: Provide 24x 100Mbps downlink PoE Ethernet ports, 2x gigabit uplink Ethernet ports and 1x gigabit Fiber port, Downlink Ethernet ports support PoE , each port supports max. 30W output, Support power consumption indication (LED indicates power output status), Accord with IEEE802.3 , IEEE802.3u, IEEE802. 3ab, IEEE802.3 af/at standard, 4K MAC address, 2.75Mb cache. operating- windows, Android and iOS] Including all fixing accessories. (Make: CP Plus/ Hikvision/ Dahua/ equivalent as per EIC choice.) |
| 1217 | SITC of Surveillance HDD 6TB Drive HDD 3.5 inches SATA 6 Gb/s 256 MB Cache for DVR NVR Security Camera System with Drive Health Management. [Specifications: Best-Fit Applications are Network Video Recorders (NVR), Embedded Surveillance DVRs (SDVR), Hybrid Surveillance DVRs, and Surveillance DVRs, Lower power consumption means a reduction in heat emissions, which improves reliability in surveillance solutions. Tarnish-resistant components help protect drive from environmental elements, increasing field reliability,] with including all fixing accessories. minimum 7200 rpm for video storage. (Make: SEAGATE/ WESTERN DIGITAL/ HITACHI/ equivalent as per EIC choice.) |
| 1218 | Supply & Laying of 6 core Fiber Optic Cable (Armoured) protected by Glass-yarn in between corrugated Steel tape & loose -tube, with Excellent Water Proof Layer & Good Moisture Resistance Suitable for Indoor / Outdoor (duct) Local Area Network System, [Specifications: Operating Temperature: -20 deg C to +60 deg C; Storage Temperature: -40 deg C to +60 deg C; Jacket Material: LSZH / HDPE; Outer Diameter: 9mm to 9.5mm +/- 0.3mm; Jacket Thickness: 1.8mm +/- 0.2mm; IEC: 60793-1/ 60794 -1-2; ISO: 11801; ITU-T: REC G.652D; Telecordia: GR-20 Core] (Make: Dlink/ Digisol/ Finolex / equivalent as per EIC choice.) |
| 1219 | SITC of 108 cm (43 Inches) HD LED Monitor, Resolution: Crystal Processor 4K (3,840 x 2,160), Refresh Rate: 60 Hz; Connectivity: 2 HDMI ports to connect set top box, Blu Ray players, 1 USB ports to connect hard drives and other USB devices; Sound : 20 Watts Output, Dolby Digital Plus, Personal Computer, Screen Share, Music System, Display: LED Panel, Mega Contrast, PurColor, HD Picture Quality, Picture Quality Index- 900, Slim & Stylish Design] (Make: Samsung/ Sony/ LG/ equivalent as per EIC choice.) |
| 1220 | Testing, commissioning & installation of whole CCTV system with qualified Engineer with own suitable tools as directed by EIC. |
| 1221 | Supplying & Drawing LAN cable (CAT6) (Brand approved by EIC) in prelaid PVC rigid conduit/ in polythene pipe embeded in wall. (Make: Dlink/ Digisol/ Havells / equivalent as per EIC choice.)[ Ref :- DSR-2022/Page- |
| 1222 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 1223 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm) |
| 1224 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm [ for 2X6 Amp Separate Socket ] |
| 1225 | 3 x 2.5 sq. mm [ For 2X16 Amp separate Socket ] |
| 1226 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet |
| 1227 | 5/6 A switch |
| 1228 | 6 pin 15/16 A socket outlet |
| 1229 | 15/16 A switch |
| 1230 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 1231 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 1232 | 39. Sunstation along with HT & LT PArtSUB-STATION HT PanelSupply & Delivery Indoor-type, floor mounted,metal clad, single tier, fully compartmentalized,free standing, 6/6.6/11 kV VCB Panel with 3 Nos VCBs (1 Incomer + 2 Outgoing), totally enclosed and fully interlocked , horizontal drawout, horizontal / vertical isolation type breaker as per IS 13118, as ammended upto date and as per detail specification attached ( uploaded in the specification section) , suitable for use on 6/6.6/11 KV, 3 Phase,50 Hz AC supply to energise TWO 250 KVA Dry Type/Oil Type Transformers. [ Make : ABB / Siemens / CGL]. |
| 1233 | Installation & commissioning of the above VCB Panel with P.T & all the accessories, incl. carriage, by placing in position, assembling, lining up, levelling and checking all instruments, relays, correctly set according to requirement. |
| 1234 | TransformerSupply & Delivery of Cast Resin Dry Type/Oil Type Transformer of 6.0/6.6/11 KV to 415V, 1 no. 250 KVA, 3 Phase,50Hz, Dyn11,copper wound, Class F insulation associated with winding temperature indicator/controller,having cable end box in the HV & LV sides and all accessories and conforming to IS 11171-1985 & IS - 2026 with latest modification (if any) & CBIP Specification and as per detail specification attached (uploaded in the specification section) [Make: ABB/Voltamp ( Vadodara)/CGL ].Installation & commissioning of 6/6.6/11 KV to 415 volt, 1 no. 250 KVA distribution transformer incl. carriage to the substation building within a lead of 30mtr by placing in position and fixing after leveling fitting all components, connecting, checking & set of all instrument, relays according to requirement as instructed by the EIC incl. S&F base channels etc.Supply & Drawing 1.1 KV Grade 7 Core 1.5 sq.mm PVC Armoured Copper Cable from Transformer WT relay to VCB WT relay for Power & Control Supply as per direction of EICMaking testing arrangement and submitting all the test reports for high voltage testing of specified voltage incl. checking & testing of all HT / LT equipments by authorized firm of Directorate of Electricity & commissioning the installation after obtaining the Approval of Directorate of Electricity.The scope shall be also included the necessary approval from Authority also. |
| 1235 | HT CABLING IN SUBSTATIONSupplying of 6.6/11 KV (UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable conforming to IS 7098, of earthed system of following size.[ From Supplier HT Gear to Consumer HT Gear and to Transformer]. [ Make : Nicco / Gloster/Polycab/Havells/Crystal/RR cabel ]a) 3 Core x 100 Sq.mmMaking heatshrinkable joints indoor type to the ends of the following XLPE HT cable at the transformer end as well as at the VCB ends supplying with necy. jointing kits, sockets, sleeves, anti-corrossive paste, wires, solders, jointing compounds, rubber sheets etc. incl. supplying of necy. tools & tackeles for crimping the end sockets, soldering irons & making of glands at the both end of the cable as per directions of EICa) 3 Core x 100 Sq.mm Laying of 1 No. 6.6/11 KV (UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable confirming to IS 7098, of earthed system of following size in the existing Masonary Open Duct as required.a) 3 core 100 sqmm |
| 1236 | [ SAFETY EQUIPMENT ]Providing & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscription in signal red colour on front side as required. a) 4 Nos. High Voltage - size 250mm x 200mmb) 4 Nos. Low Voltage - size 200mm x 150mmProviding and fixing carbon dioxide (CO2) type fire extinguishers conforming to IS 15222-2002 and cylinders fully charged of following capacity(4.5 Kg ) [Make - Fire Shield/ Ceasefire] ---- min 8 nos.Supply and fixing of foam fire extinguishers conforming to IS 4989-2006, Portable type 9 lit capacity hanged on wall with bracket complete as required. [Make - Fire Shield/ Ceasefire] ---- min 4 nos.Supply and fixing safety instruction chart in word duly framed with 5mm thick glass as required (approx. Front area 1.20 sq.mt.) --- 5 nos.Providing of set of 4 nos. 9.5 litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and written with white paint 'FIRE' and mounted on MS angle iron frame with bracket and suitable base of appropriate size & capacity I/c filling sand etc. --- 4 nos.Providing First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross conforming to IS 13115-1991. ---- 3 nos.Supply and fixing shock treatment chart duly mounted on a wooden frame with 5mm thick glass as reqd. (approximate front area 1.20 sq.metre). ---- 6 items.Providing of rubber mat 2 mtrs Length x 1 m. wide and 12mm thick to withstand 11 KV dielectric strength as per IS 15652-2006. --- 6 nos.Providing of rubber mat 2 mtrs Length x 1 m. wide and 6mm thick to with stand 3.3 KV dielectric strength as per IS 15652-2006. --- 6 nos. |
| 1237 | LT PANELS[ LT MAIN PANEL IN THE SUBSTATION ] SITC of floor mounted Indoor type extensible cubical MV switchboard,fabricated by CPRI approved panel maker having compartmentalized design, fabricated out of 14 SWG ( 2.0 mm ) nominal thickness CRCA sheet steel,front and back openable, hinged, single shuttered, with incoming ACBs & Outgoing MCBS and all accessories as per size, design & drawing to be approved by EIC and conforming to IS with latest modification and as per detail specification attached ( uploaded in the specification section Main LT Panel ) |
| 1238 | Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable(Armoured ) conforming to IS: 7098 / 1988 with its latest amendment and laying those in underground trenches incld. Socketing and finishing the ends of the socket of following size4 Core 120 Sq. mm |
| 1239 | MISCELLANENOUSSubmission of a Sub Station drawing ( Computer AUTOCAD generated & printed in A1 sheet in Triplicate) showing HT & LT cable ducts single line power diagram EI Layout Earthing system ( Equipment neutral earthing) etc entire plan asd per direction & satisfaction of EIC and as per reqirement of DOE( For GREEN SUB-STATION) |
| 1240 | Exhaust Fan Arrangement for better air circulation and heat dissipationS & F single phase Timer DB for automatic ON/OFF split AC machine in 10 way SPNDB enclosure (Make-Legrand/L&T) and following accessorirs & wiring complete.i) 240V, AC, 32A, 2P Power contactor type MNX22-2P (Make-L&T)-2 Nosii) Time switch FM Quartz Daily dial 15 minute interval settings (Cat No. J648 B1, Make- - L&T) -1no.iii) 25A, DP MCB (Legrand) - 2 Nos iv) 4 way terminal Block- 1No.v) 10A automatic Toggle switch - 1 no.vi) A.C. ON/OFF indicator- 1 setvii) ON/OFF push Button - 1setall interconnection wiring should be done with 1.5 Sq. mm FRLS copper wire end termination & making properly. |
| 1241 | Supply and fixing of 240V 1370 rpm AC exhaust fan(EPC Make) after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of given diameter.i) 12'' Sweep |
| 1242 | Supply & Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long)i) 12'' Sweep |
| 1243 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Havells/Polycab/Finolex/KEI/Gloster/RR Kable) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required ii) 2x1.5 sqmm + 1x1.5 sqmm as ecc. |
| 1244 | Sub Total Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail