| Sl. No. | Item Description |
| 1 | Taking out existing CC interlocking paver blocks/ PCC tiles from footpath/ centralverge, including removal of rubbish etc., disposal of unserviceablematerial to the dumping ground, for which payment shall be madeseparately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge (DSR 16.83) |
| 2 | Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 3 | Taking out existing channel stones of all types from footpath/ central verge, including cleaning of channel stone from cement mortar and stacking of serviceable material within 50 metre lead as per direction of Engineer in Charge. (N.S.) |
| 4 | Scarrifying/Dismantling of SDBC/Bitumen concrete with latest mechanical means complete in all respect and disposal of dismantled material with a (average) lead of 3 km and to the entire satisfaction of the Engineer-In-Charge. |
| 5 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer in charge Nominal concrete 1:4:8 or leaner mix (DSR 15.2.2) |
| 6 | Carriage of building rubbish by mechanical transport including loading, unloading and stacking for lead upto 10 km. (DSR 1.1.1) |
| 7 | Dismantlling of M.S. railing and removing of CC 1:2;4 block of size 1'-0\\" x 0'-9\\" x 1'-0\\" complete in all respect to the entire satisfaction of Engineer-in-Charge. |
| 8 | Providing and laying in position cement concrete 1:5:10 of specified grade excluding the cost of centring and shuttering all work upto plinth level: (1 cement: 5 coarse sand: 10 graded stone aggregate 40mm nominal size). Complete in all respect to the entire satisfaction of the Engineer-In Charge. |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering 1:1½:3 (1 Cement :1½ coarse sand :3 graded stone aggregate 20 mm nominal size). |
| 10 | Providing and cutting of 4mm wide grooves with average depth 25mm to 40mm (i.e. depth of groove = d/3 i.e.d is thickness of floor) with 3.2mm thick blade & mechnical rotor at requisite distance as specified by Engineer-in-Charge after 5 to 7 days curing period of concrete including arrangement of electricity generator for running of rotor machine complete in all respect to the entire satisfaction of Engineer-in-Charge. |
| 11 | Providng and laying exposed aggregate flooring of thickness 20-25mm over freshly laid cement concrete. The aggregate used in flooring shall be as per the approved design, shade, size and texture alongwith proportionate mixing as desired by design consultant/ EIC. The aggregate shall be mixed with bonding agent and placed in uniform thickness. The top layer of exposed aggregate shall be kept intact with lithium based densifier/hardener complete in all respect to the entire satisfaction of engineer-in-charge. |
| 12 | Providing and fixing PCC kerbs of size 1’-0” x 1'-0” having 4” thickness at bottom and 3” thickness at top and made of plain cement concrete 1:2:4 duly vibrated and compacted. The rates also includes the cost of filling and pointing of joints between kerbs with cement mortar 1:4 (1 cement 4 course sand) Complete in all respect to the entire satisfaction of Engineer In Charge. |
| 13 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR : 10.25.2) |
| 14 | Providing and fixing Merry-go-round entry gate (revolving gate) with 1 No vertical MS pipe of 50mm dia 2'-9\\" long above ground level and 2'-0\\" in ground to support revolving shutters. The revolving shutter frame consists of MS flat of size 50x8mm 2 nos horizontal flats of size 2'-9\\" long and 2 nos vertical flats of size 1'-0' long with perforated jalli welded to one section of both frames of size 1'-3 1/4\\"x 1'-8\\".The gate shall be properly embedded in cement concrete 1:2:4 be painted with two coats of approved quality deco paint over one coat of primer complete in all respect to the entire satisfaction of Engineer- in-Charge. |
| 15 | Providing and fixing 18mm thick gang saw cut mirror polished (premoulded and prepolished) machine cut for kitchen platforms, vanity counters ,window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing moulding and polishing to edge to give high gloss finish etc. complete at all levels: Granite of any colour and shade: Area of slab over 0.50 sqm(DSR 8.2.2.2) |
| 16 | Providing and making various structural/ aesthetic elements of various shapes and size as specified in the drawings. The elements shall be made up of reinforced cement concrete grade of grade M25, complte in all respect to the entire satisfaction of EIC.(Only payment upto RCC finished structure shall be paid after calculation of volume involved) |
| 17 | Surface finish with terrazzo chips (granite, marble, quartz etc) / broken tiles to be placed on RCC structure of laid uniformly over already prepared surface using bonding agent to provide required finish . The chips shall be placed using paste made up of white cement, marble dust and chips (ratio 2 chips: 1 white cement). The surface shall be finished to achieve required texture and uniformness to provide required shade and finish as desired by EIC and complete in all respect to the entire satisfaction of Engineer In Charge |
| 18 | Preparation of mounds and landscaping of various shape and size by available excavated/supplied earth in layers not exceeding 20cm in depth, breaking clods, watering of each layer, dressing etc lead upto 50m and lift upto 1.5 . The rate also include grassing with selection no 1 door grass including watering and maintenance of lawn for 30 days or more till the grass forms a thick lawn, free from weeds, complete in all respect to the entire satisfaction of EIC |
| 19 | Construction of Bioswale for rain garden along road and garden spaces. The rate includes excavation of earth, dressing of surface, providing and laying geotextile layer on dressed surface.The stone aggregate of size 40mm of thickness 12”, 20mm of thickness 9”, 6mm of thickness 3” shall be laid in layers from thickness varying minimum to maximum from top to bottom. The bio retention soil of thickness of 3” shall be laid on top of stone layer. The mulch layer of thickness 2” shall be placed on bio retention soil and plantation of low growing wetland plant shall be done on top layer. The rate also include providing and placing pvc perforated pipe of dia 4” in stone aggregate layer, complete in all respect to the entire satisfaction of Engineer In Charge |
| 20 | Construction of perforated pavement by excavation of earth, dressing of surface, providing and laying geotextile layer on dressed surface.The stone aggregate of size 40mm of thickness 12”, 20mm of thickness 9”, 6mm of thickness 3” shall be laid in layers from thickness varying minimum to maximum from top to bottom. The paver blocks of desired shape and size and colour as specified by the EIC shall be placed on top layer with 5-10mm groove in between which shall be filled with crushed stone aggregate.The rate also include providing and placing pvc perforated pipe of dia 4” in stone aggregate layer, complete in all respect to the entire satisfaction of Engineer In Charge |
| 21 | Providing and fixing 60 mm thick high density factory made rectangular shape cement concrete interlocking paver blocks of M-30 grade made by rubbermoulding or block making machine with strong vibrating compaction and of approved size and design/shape laid in required color and herringbone pattern over 20mm thick cement mortar 1:3 complete as per directions of Engineer- in -charge. (Any colour Grey/black/red/yellow/green) |
| 22 | P/F Precast M35 SFRC (brass coated Steel Fiber reinforced concrete) tile of size 1200 x 600mm and 40mm thick to be casted in customised rubber mould using coloured concrete made of UV resistant pigment and Minimum 5% content of steel Fiber. The cycle logo for light transmission is made by embedding 6mm thick acrylic milky white sheet (040 grade).The top surface is to be grinded and polished ( with final coat of deep penetration lithium silicate based sealer. The rear side of acrylic is to be filled with extra clear transparent epoxy to enhance rigidity of embedded acrylic and seal the interface joint of acrylic and concrete. Waterproof LED strips (Osram / Ledvance) of grade IP68 and warm white Color tone (4000k) is to be fixed on waterproof & termite resistant board and placed 35mm beneath the SFRC tile for uniform light transmission. Duly primed and painted metal frame work to be pasted using PU adhesive (Keralastic/ kerakol) onto the SFRC tile with sufficient support provided and with additional base frame for light board to be used. Complete in all aspect as per approved drawing. The rate also include fixing of panel at site in complete respect to the entire satisfaction of EIC |
| 23 | P/F Precast M35 SFRC (brass coated Steel Fiber reinforced concrete) tile of size 1200 x 600mm and 40mm thick to be casted in customised rubber mould using coloured concrete made of UV resistant pigment and Minimum 5% content of steel Fiber. The pedestrian crossing for light transmission is made by embedding 6mm thick acrylic milky white sheet (040 grade).The top surface is to be grinded and polished ( with final coat of deep penetration lithium silicate based sealer. The rear side of acrylic is to be filled with extra clear transparent epoxy to enhance rigidity of embedded acrylic and seal the interface joint of acrylic and concrete. Waterproof LED strips (Osram / Ledvance) of grade IP68 and warm white Color tone (4000k) is to be fixed on waterproof & termite resistant board and placed 35mm beneath the SFRC tile for uniform light transmission. Duly primed and painted metal frame work to be pasted using PU adhesive (Keralastic/ kerakol) onto the SFRC tile with sufficient support provided and with additional base frame for light board to be used. Complete in all aspect as per approved drawing. The rate also include fixing of panel at site in complete respect to the entire satisfaction of EIC |
| 24 | Providing and Fixing of bidirectional Solar Road Stud of self illummation made of multi crystalline silicon solar panel flashing hype having 4 nos ultra bright LED'S of red made of metallic body , ultra LED's red/yellow/blue/green/white coloured. It shall have flashing rate of 2HZ or 5HZ and 2 rechargeable NI-CD or Ni-MH battery which give backup of at least five days from fully charges condition aluminum die cost housing having reflector stip in addition to LED's. The stud is capable of withstanding the load if 12n tons having tampering both m anchor of minimum 50mm length It is water proof and capable of withstanding temperature betweets 25 degree C and 55 C Fixing will be by drilling holes on the road for the twin moulded shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendationFixing will be by drilling holes on the road for the twin moulded shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendationcomplete in all respect to the entire satisfaction of the engineer in charge. Conditions: The Solar stud should carry test certificate for the compressive strength from reputed and independent NABL accredited laboratory. |
| 25 | Providing and fixing Signage for tree's name with discription about the tree on MS sheet base plate of 14 gauge of size 6\\"x9\\". two coats of approved quality paint over one coat of primer complete in all respect to the entire satisfaction of Engineer- in-Charge. |
| 26 | Providing and applying 2.5mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour ,T&P, cleaning the road surface of all dirt, seals,oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications. |
| 27 | Providing and fixing of clay tile of size 8\\"x8\\" x2.5\\" of desired pattern in MS frame as per details and drawings specified by EIC. The clay tiles are to be procured before the fixing and are to be checked for any breakage of defects. The tiles are to be fixed in the existing MS frame using clamps and adhesive complete in all respect to the entire satisfaction of EIC. |
| 28 | Re-fixing Of Old paver block of 60mm cement concrete interlocking paver blocks of M-30 grade made by block making machine with strong vibrating compaction and of approved size and design/ shape laid in required color and pattern over and including 20-30mm thick compacted bed of sand, filling the joints with coarse sand etc. complete as per the directions of Engineer-in-charge. |
| 29 | Manufacturing supplying and fixing retro reflective mandatory sign boards consisting of 600 mm diameter sign boards and definition plate of Size 600x230mm made up of 3mm. thick ACP sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming. to type IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message ,symbols and borders etc. as per IRC 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956 01 and welding the same with 3660mm high vertical post of M.S. angles of size 50x50x5 mm welded with hold fast of same size 250 mm long at the bottom end to be embedded in ground with cement concrete 1:2-4 block of size 300 x 300 x 450mm The plate is to be processed by stove enamel paint of approved brand and painting white and black colour alternate bands of 300mm long over one cost of priming coat to vertical post and steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat, complete in all respects and to be entire specification of Engineer-in charge (NS) |
| 30 | P/F rotary ahead / Pedestrain Crossing ahead sign boards have equilateral triangular shape having each side of 900 mm and the definition plate of size 600mm x 300mm both made out of 3mm thick aluminium sheet, fixed to back support frames of size of angle iron 25x25x3mm. The front side of both ACP sheet shall be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets to back support frame of M.S. angle iron along with theft resistant measures, mounted and fixed with welding / nut and bolts to 3660mm long vertical post made of M.S hollow square pipe having size 50 mm x 50 mm and thickness of 4.5mm @ 6.02 kg/mtr having anchorage piece made out of same angle of size 250mm long embedded in ground with cement concrete 1:2:4 block size 300x300x450mm. The steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS support to be painted in black and white colours). Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-charge. |
| 31 | Providing and fixing of Informatory sign board, rectangular of size 90x60cm consisting of ACP sheet 3mm thick. The retro reflective high density Type IV sheet will be provided on base of sign plate and definition plate having size 600x300mm. Red reflective border 65mm wide shall also fixed on sign plate and black reflective shall be used as sign on sign plate and lettering on the definition plate. Both sign plate and definition plate is to be fixed on 360mm long vertical post of M.S. angle iron 50x50x5mm with anchorage piece of same angle of size 9\\" long embedded in C.C.1:2:4 in the block of 1'x1'x1' 1/2\\" complete in all respect and to the entire satisfaction of Engineer in charge. |
| 32 | Providing and fixing coloured ceremic (Tactile) tile, ground surface indicators of size 300 x 300mm of approved make for guiding/direction/warning to the visually impaired visitors, in the centre/side of the pedstrain/approach pathway as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade to tiles as per design/ specification and guidelines complete in all respect to the entire satisfaction of Engineer-in-charge. Note: - The tile shall be premium quality (1st quality) of reputed manufacturer like NITCO, KAJARIA, SOMANI, ORIENT & JONHONSONS. |
| 33 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil ( DSR 2.6.1) |
| 34 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) |
| 35 | 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) (DSR 13.1.2) |
| 36 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge: Granite work (DSR 8.3.2) |
| 37 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone: Red sand stone (DSR 11.29.1) |
| 38 | Providing and laying granular sub base by providing and laying, spreading and compacting course graded sub base material sand, morrow, graval, crushed stone of combination thereof confirming to grading –I of table 400.2 of MORTH specification (5th revision). The material shall be mixed by mix in place method or with rotavator at OMC and carried to site, spread in uniform layers and compacted with 8-10 tones smooth wheeled/Vibratory roller to achieve desired density. Complete in all respect as per clause 401 of MORT&H specification (5th revision) |
| 39 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant,carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per clause 406 of MORT&H specification (5th revision). Complete in all respect to the entire satisfaction of Engineer In Charge. |
| 40 | Providing and fixing in position RCC manhole cover and frame of required shape and approved quality circular shape 560mm internal diameter. (DSR 19.19.3.1) |
| 41 | Providing & Fixing of pre-cast R.C.C. M-20 R.C.C. slab & frame in 1:2 Cement sand mortar on the top of brick masonry chamber complete in all respects as per the entire satisfaction of the E.I.C. size of cover 690 x 537x 80 mm size of frame 810 x 657 x 130 mm |
| 42 | Providing and fixing • UV stabilized Poly propylene module having wall thickness of 2mm. Each module having specially designed rib strip of 60-degree angle to maintain the center of gravity.. The installation of planter will be over poly propylene mounting strip to make it wind/theft proof.• Poly propylene mounting strip, including supply of the hardware of the same.• Providing and filling green wall modules with classified composition of longevity enabled growth media having water retention properties enriched with natural mineral nutrients and slow releasing natural fertilizers.• Providing & planting of suitable plants well settled and growing in longevity enabled light weight non- biodegradable growth medium. Selected on the basis of temperature, incidence of sun light and humidity on site, in pattern finalized in consultation with client/department. • Supply and installation of drip pipes with inline adequate pressure.Complete in all respect to the entire satisfaction of Engineer In Charge (NS) |
| 43 | MS Bench- Providing and fixing of M.S beam of size 1\\"x2\\" joined horizontally to M.S. frame(box section 1\\"x2\\") as per details and drawings, M.S. box section (1\\"x3\\") bolted to th ems. Frame and beam and finished with reflective paint wooden texture (asian) or charcoal grey duco painted complete in all respects and checked by the engineer in charge. |
| 44 | Bike station-Set of 6- providing , fabricated and installation of bike stations of size 1'-3\\"x1'- 3\\" of M.S. pipe of thk. 1/2\\" as per design and drawings fixed and bolted on M.S. flat platform fixed to ground by boltings. |
| 45 | Linear Seaters-M.S. BEAM Providing and Fixing of M.S. box section of size 4\\"x2\\" bolted and fixed on terrazo pedestal finshed with wood finish(ASIAN) reflective paint or charcoal grey, M.S. section 1\\"x2\\" bolted to central M.S. beam below with 1\\" gap and finished with wood finish(asian) reflective paint or charcoal grey duco paint as per approval or light weight F.R.P. finished in wooden texture complete in all respect as per design & drawings, complete in all respects and checke by the Engineer-in-charge.TERRAZO PEDESTAL-Providing and installing of pedestal made up of R.C.C. of suitable grade having size 1'-4\\"x1'-4\\" as detail and drawings resting on R.C.C. base or light weight F.R.P. fineshed with terrazo complete in all respect as per design & drawings, complete in all respects and checke by the Engineer-in-charge.Top Layer - The mix for terrazo shall consist of cement with or without pigment, marble powder, marble aggregate (marble chips) and water.The marble chips shall be white or pink Makrana, black Bhainslana, Chittoor black, Jaisalmer Yellow, Baroda green, Dehradun white, Chittoor pink, yellow Patam cherala (Madras), grey Gadu (Surat), Chittoor green and yellow and Alwar black . It shall be sound, dense and homogenous in texture with crystaline and coarse grains. It shall be uniform in colour and free from stains, cracks, decay and weathering. |
| 46 | Cycle Sculpture-Providing and installing of sculpture of M.S. Of suitable grade and size as drawings adn details And wood of size 15'-7.5\\"x3'-5\\" slides as design and details |
| 47 | Water ATM-RCC STAND- providing and instaling of stand made up of RCC of suitable grade having size 9\\"x9\\" with grove of 6\\" at 4 side creating troughs finshed with white terrazo as per details and drawings complete in all respect and checked byth eengineer in charge.nd detailsRCC vessel - providing and installing of RCC Bowl or Vessel having DIA- 2'-0\\" with height 10\\" finished with white terrazo complete in all respects and checked by the engineer in charge.RCC storage tank- providing and installing of RCC tank of DIA 4'-6\\" and height of 3'-0\\" finished with mosaic broken tile pattern as per details and drawings including necesary arrangements of G.I. water pipeline to the nearby water supply source. |
| 48 | Circular seaters around trees-M.S. BEAM Providing and Fixing of M.S. box section of size 4\\"x2\\" bolted and fixed on terrazo pedestal finshed with wood finish(ASIAN) reflective paint or charcoal grey, M.S. section 1\\"x2\\" bolted to central M.S. beam below with 1\\" gap and finished with wood finish(asian) reflective paint or charcoal grey duco paint as per approval or light weight F.R.P. finished in wooden texture complete in all respect as per design & drawings, complete in all respects and checke by the Engineer-in-charge.TERRAZO PEDESTAL-Providing and installing of pedestal made up of R.C.C. of suitable grade having size 1'-4\\"x1'-4\\" as detail and drawings resting on R.C.C. base or light weight F.R.P. fineshed with terrazo complete in all respect as per design & drawings, complete in all respects and checke by the Engineer-in-charge.Top Layer - The mix for terrazo shall consist of cement with or without pigment, marble powder, marble aggregate (marble chips) and water. |
| 49 | P/F of topiary tree sculptures with wire mesh or cutting in shape as per the details and design having miniumum height of 2` in the planters aling with fillinf of planter with filling of good earth and manure complete in all respect to the entire satisfaction of the Engineer in Charge. |
| 50 | Providing and Laying natural Cobble Stone of Size 100mm x 100mm top finished with average thickness 75-100mm over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and Jointing with same mortar. |
| 51 | Painting steel work with deco spray metal paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate filling with putty, priming coat, preparation of surface and applying on surface with compressor etc. complete in all respect to the entire satisfaction of the Engineer in Charge. |
| 52 | Extra for making moulds for various structural/aesthetic elements of various shapes as specified in the drawings. The moulds shall be in accordance with the drawings and detailing shall be given for curvature and shape. complete in all respect to the entire satsifaction of site engineer In Charge |
| 53 | ELECTRICAL WORK-PART B |
| 54 | Supply & Erection of Steel Pole 4 mtr. height are made of Galvanised Mild steel tubes having upper part is (Ø 75mm x 3mm) bottom part of the pole (Ø 140mm x 4.0mm) and length of pole (1000mm x 3000mm) made out of mild steel galvanised tubes. The bottom and middle part of the poles are fitted with cast Iron/Aluminium embellishments as shown in the drawing. The poles has a service window at the bottom containing 25 amp connector terminal and MCB of the desired rating. The antidoor theft strip 30mm x 4mm should be attached with junction box protection. The poles are primer coated and painted with polyurethane paint of the desired colour. Poles are suitable for Single/ Double/ Triple/ Four Side Post Top/Drop Down Luminaries. The Poles has a service window at the bottom comprising four way 25Amp Connector terminal and a MCB. Poles has a mild steel base plate having four numbers mounting holes as er drawing and can be mounted with four numbers anchor bolts. Prefered make,Havells Lux MaxSP-140-75 - Twinkle, MFMD 202D & Mayfair lighting (picture atteched) (over all diamation may very but shape must be as attached in picture) or its equivalent Surya, Bajaj, K-Lite. Rate inculdes the base plate of approx dimention (300x 300x 12mm) and J type nut bolt and all other material required for complete erection of poles and all relevant testing standard certificated must be submiied alond with geniune certificated . The work must be completed as per the entire satisfaction of Engineer-in-Charge. |
| 55 | Dismantling and Re-erection of Decorative Pole 4 Mtr. long alongwith Decorative Light Fitting etc. & other material complete in all respect. The job shall be completed to the entire satisfaction of Engineer-in-charge. |
| 56 | RCC FOUNDATION For 4 Mtr. Long pole:The foundation has to vetted from expert and submit the drawing. The work must be complete as per the entire satisfaction of Engineer-in-Charge. |
| 57 | DSR ITEM NO. 2.8.1 (CIVIL WORK) - 2022Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kinds of soil (Size 0.46mx0.46mx1.21m)= 0.26 cum (122 nos. x 0.26= 31.72cum) |
| 58 | DSR ITEM NO. 5.9.1 (CIVIL WORK) - 2022Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete Size 1x2 (3.100+3.100) 0.45 = 5.58 sq.mtr. Size 1 - 180mm x 380mm = (1.18mx0.38m) = (0.45x4=1.80 sq. mtr.) Total (122 nos. x 1.80= 219.60 sq. mtr.) |
| 59 | DSR ITEM NO. 5.2.2 (CIVIL WORK) - 2022Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)Size 1 - 380mmx380mmx118mm = (0.38mx0.38mx1.18m) = 1704. cum Total (122 nos. x 0.1704= 20.788 cum) |
| 60 | DSR ITEM NO. 4.1.11 (CIVIL WORK) - 2022b) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) (0.43mx0.43x0.05m =0.0092 cum) (122 nos. x 0.0092=1.122 cum) |
| 61 | DSR ITEM NO. 5.22.6 (CIVIL WORK) - 2022Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars1.Horizontal Bar10 mm dia = 8 nos.x 2.24mm= 17.92 r.mtr @ 0.390 Kg per mtr.= 6.98 kg2.Vertical Bar 12mm dia =4 nos.x 1.66 mm= 6.64 r.mtr @ 0.89 Kg per mtr.= 5.9 kgTotal (6.98 + 5.9=12.85+5% wastage = 13.49 kg) (122 nos. x 13.49= 164.78kg) |
| 62 | Supply, Erection, Testing & Commissioning of Decorative Post Top 90 watt (L-575+340=915, Width- 625) Colour Temperature 5500-7000K having efficacy >100 lum/W; Frequency 50 ~ 60 Hz, THD >10%, Power factor >0.95, CRI > 80°, Life > 50,000 Hrs, Operating Voltage Range - 100V - 270Volts.light made of die cast aluminum housing with bracket. A UV stabilized PC/ PMMA diffuser is provided for glare free lighting with high visual comfort. The Lantern is painted with polyester paint. Prefered make Lux Max PT 157 90 Watt, twinkle, MF PTL LED 664 of Mayfair lighting or its equivalent Surya, Bajaj, K-Lite, Havells. (over all diamation may very but shape must be as attached in picture) Rate includes all the accesriors inculding nipple and all other accessories required. The fixture should be comprehensively warranted to be replaced or repaired for any defect on site warranty within 2 Years of installations and all relevant testing standard certificated must be submiied alond with geniune certificated . The work must be completed as per the entire satisfaction of Engineer-in-Charge.The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 63 | G.I. Earth pipe electrode without salt/ Charcoal: DSR 5.2/2022 Supply and laying of earth electrode made out of ISI marked 'B' class earthing with G.I. earth pipe 4.5 mtr long, 40mm dia including accessories, G.I. pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom (without charcoal or coke and salt). The earth electrode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the Engineer-in-charge. |
| 64 | Painting of existing Decorative 4 Mtr pole in Gray Colour ISI marked with the help of gun machine before paint the pole should be proper dismantled at site with the help of labour and after paint pole should be re-erected same location at site. The work will be executed to the entire satisfaction of Engineer-in-charge. |
| 65 | P/F 6 SWG GI earth wire in pipe: DSR 5.12/2022 Providing & laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode, as required. |
| 66 | Dismantling of existing Steel tubular7.5/9. Long along with Junction Box, fittings with Wire & bracket etc. & other material complete in all respect to the satisfaction of Engineer-in-Charge. The entire “malba” shall be disposed off and send to C & D plant Industrial Area Phase-I.The contractor shall hand over the dismantled material to the J.E-in-Charge at central store in proper form duly accounted or the same may be considered as recovery/ buyback as per conditions of DNIT. |
| 67 | Dismantling of M.S. Junction Box 10\\"x12\\"x4\\" with CC Collar including dispose of the malba after disconnection of the same and dumpling at the Cooropriate place. The work shall be executed to entire satisfaction of Engineer-in-charge. The entire “malba” shall be disposed off and send to C & D plant Industrial Area Phase-I.The contractor shall hand over the dismantled material to the J.E-in-Charge at central store in proper form duly accounted or the same may be considered as recovery/ buyback as per conditions of DNIT. |
| 68 | S&E of Outdoor type both side with L-key lock arrangement openable M.S. Cubical Pedestal of size 1200mmx 900mm x350mm fabricated from 16 G.M.S. sheet welded on M.S. angle iron frame of size 50mmx 50mm x6mm with 4 Nos. legs of angle iron of same size each of length 600mm with M.S. sheet of size 100mm x 100mm x 6mm thick at the bottom of the legs. The front side and the back side of the pedestal should be openable with hinged door provided with Godrej type locking arrangements. A 'U' type support made from M.S. sheet of 16 G having width 75mmx 6mm be welded vertically in the inner side of the door to avoid entry of water. The door of the pedestal should be provided with rubber gasket to avoid entry of other insects etc. The top of the pedestal shall be covered with canopy made out of 16 G M.S. sheet projected outside to avoid entry of water. Four No. supporting members each of size 50mm x 6mm thick according to cubical size shall be welded for mounting switcher gear i.e. ICTPN, BBC, Timer and energy meter etc. The Pedestal shall be painted with two coats of P.O. red paint after applying one coat of red oxide. One No. The legs of the pedestal shall be embedded in the 1:2:4 C.C. mixture by digging 1' deep pit of 1' dia. The letter 'M.C.C.' in 4\\" size shall be written on the front door of the Pedestal. The job also included supply and erection one no. wooden plank/ board of size 1’-6’’ x 1’-6’’ and 25mm thick suitable for fixing energy mater including cost of screw, nuts and bolts in cubical pedestal complete in all respect. The pedestal will be housed on RCC foundation, Snowcem and platform of size 900mm deep (450mm underground and 450 mm above ground x 960 mm long x 410 mm wide including sufficient number of DWC pipe size of 51/63mm pieces to facility to entire the main cable and the circuit cable. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 69 | Supply & laying PVC insulated Aluminum Conductor armoured ISI Marked cable of 3.5 Core 35 mm sq in Trench/Pipe. Supply & laying of ISI marked 3.5 core 35 mm sq PVC Insulated Aluminum conductor armoured cable (PVC Sheathed) of make Sunhome/ Finolex/ Cirtina/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable to be laid in trench/ pipe as per DSR Code 7.5.1/2022 MV CB PIP-25 Part-II (External). The cable should be terminated existing/ new cc collar with proper thimbling. The job included all Connections, Commissioning and testing of phase supply Material Testing report to be submitted and material to be supplied at site after confirmation from Engineer-in-charge. The specification of the cable as below:- i) Conductor – Aluminumii) Core – 3.5iii) Working Voltage – 1100 Viv) Nominal Cross Section – 35mm2 v) Minimum No. of Wire – 7/6The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 70 | Supply & Erection of Three Phase Aluminum Bus BarSupply & Erection of Three Phase Aluminum Bus Bar of size 300mmx 25mmx 5mm with L type fuse unit to be fixed on Porcelein insulators in the existing pedestal with required nuts, bolts & M.S. sheet. The fuse links should be equal to the number of outgoing circuits. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 71 | S&E of Mouled Case Circuit Breakers (MCCB) of rating 100 Amp with Breaking Cap 16 kA, 415 Volts.Supply & Erection of 3 pole, 16 kA, 100 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 72 | Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminium armoured cable loose in trench/pipe:-Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminum conductor armoured cable (PVC Sheathed) of make Sunhome/ Finolex/ Cirtina/ Ecko/ Lapp/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable to be laid in trench/ pipe as per DSR Code 7.5.1/2022 MV CB PIP-25 Part-II (External). The cable should be terminated existing/ new cc collar with proper thimbling. The job included all Connections, Commissioning and testing of phase supply Material Testing report to be submitted and material to be supplied at site after confirmation from Engineer-in-charge. The specification of the cable as below:- i) Conductor – Aluminumii) Core – 4iii) Working Voltage – 1100 Viv) Nominal Cross Section – 16mm2 v) Minimum No. of Wire – 7/6vi) Insulation Thickness – 1.0mm (Nominal)vii) Inner Sheath Minimum Thickness – 0.3mm viii) Outer Sheath Minimum Thickness – 1.40mmix) Nominal size of Armoured Wire/Strip – 4x0.8mmx) Approximate O.D. – 22mmMaximum d.c. Resistance at 20 Deg. C – 1.91 ohm/kmThe work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 73 | Supply & Laying of DWC pipe 51/63mm with hand bockey:- DSR 14.15.1 (75 cm below) Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) With Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930/ IS 16205 complete with fitting and cutting, jointing etc.direct in ground (depth as per the direction of Engineer in charge or upto 75 cm below ground/ road level by digging the ground or cutting the road/ paver blocks upto required level & laying of DWC pipe for laying L.T. upto 1.1 KV grade) cables etc. including excavation and refilling the trench but including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Rex, Duraline. The entire satisfaction of Engineer-in-Charge of work. |
| 74 | S&E of Mouled Case Circuit Breakers (MCCB) of rating 200 Amp with Breaking Cap 26 kA, 415 Volts.Supply & Erection of 3 pole, 26 kA, 200 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 75 | Supply & Erection of 8 Mtr. long Hot dipped Galvanized pole of octagonal cross-section continuously tapered made out from high tensile steel of minimum thickness 3mm with the base plate of minimum size 225mm x225mm x16mm alongwith inbuilt lockable Jn. Box which should be operated with single key with connectors of Elmax / Connectwell / Essen / Wago make for the cable termination and 2/3 terminals and one no. 6 Amps. Single Pole MCB for each luminarie. The diameter across from the dimensions of the base and top of pole should be minimum of 13mm x 70mm A/F (Across Face). The size of the poles and foundation bolts shall be suitable to withstand the maximum wind speed / pressure 180 Km/hr. as per IS-875 Part-II. There should be no any circumferential welding on the pole and pole shall be preferably be fabricated in one singal section. The Antidoor theft strip 30mmx4mm should be attached with junction box protection and welding in Junction Box cover of Octagonal Pole for theft. The method and material shall comply with as per BSEN-10025 Grade with yield strength of 355 Mega Pascal. The Poles should be hot dipped galvanized in single dip to 65 micron min. confirming to IS 2629-1966 and IS 4759 / BSEN-146. The material and specification of flange plate/base plate shall be as per IS 2062. The street light poles shall be erected in the existing RCC foundation with 4 nos. special steel foundation bolts ‘J’ type minimum 700mm long galvanized M.S. rod of duly threaded of minimum 20mm dia in existing RCC foundation of suitable size as per approved drawing attached. The material of steel foundation belts shall be confirming to grade EM-8 exposed theaded portion of foundation bolts shall be hot dipped galvanized. (The cost of 8 Mtr. long S/L octagonal pole is including with 4 nos. ‘J’ type bolts and nuts, washers, anchor plates & templates etc.) Minimum weight should be 90 to 99 kg all relevant testing standard certificated must be submiied alond with geniune certificated . The make should be Bajaj/ Transrail/ Valmont/ Utkarsh. The Pole shall be got approved from Engineer in charge before executing the work. |
| 76 | SUPPLY & ERECTION OF G.I. PIPE BRACKET 5 FEET O/H SINGLE ARM (1.5 METER) HOT DIPPED GALVANISED SINGLE ARM BRACKET 1500 MM. LONG ON ONE SIDE WITH 48.3 OD GI PIPE. (SUITABLE FOR POLE TOP 70 MM).Supply and Erection of 5’ over hang bracket Single Arm made of G.I. pipe medium class ISI Marked with the following specifications of Make Tata/ Jindal/ Hissar or Ravindra. The work shall be executed to the entire satisfaction of engineer-in-charge.1. The bracket shall be made by G.I. pipe of 2” dia with an angle of inclination of 105 degrees to the vertical.2. The 2” dia G.I. pipe shall be welded to 3” dia G.I. pipe canopy at a distance of 2” from top end & top end of canopy shall be covered with 14 GMS sheet to avoid entry of rainwater in S/L Octagonal Poles.3. The bracket shall be slipped over the top section of the steel tubular pole and fixed with 2 Nos. of ½” dia nuts and bolts suitable to hold the pipe absolutely tight in positions.4. Triangular 14 GMS sheet pieces of 6” diagonal shall be welded between two pipe.5. The sample of bracket shall be got approved from the Engineer in Charge before installation at the workshop where these are fabricated. |
| 77 | Dismantling of existing M.S. Cubical Pedestal of size 1200mm high 900mm wide and 350mm deep complete in all respect as desired by the Engineer-in-Charge. The entire “malba” shall be disposed off and send to C & D plant Industrial Area Phase-I. The contractor shall hand over the dismantled material to the J.E-in-Charge at central store in proper form duly accounted or the same may be considered as recovery/ buyback as per conditions of DNIT. |
| 78 | Supply & Erection of 12 Watt LED Bulk Head Fitting with system Lumens 2700 to 3000 having efficacy 100 lm/W; THD <10%, Power factor >0.95, Rated Voltage 230V, Beam Angle of LED 120°, CRI > 80, LED Junction Temperature < 80°, Workign Temprature - 10° to 50°, Working Humnidity 10% to 90% RH, Life > 50,000 Hrs, Operating Voltage Range - 100V - 270Volts. The Pressure die cast aluminium housing, power coated with weather proof gasket ensuring IP65. Ref- Make of Twinkle LuxMax- CL-S-12/ Philips/ Osram/ Wipro/ Panasonic/ Crompton total system Power consumption 12 Watt complete in all respect as required. all relevant testing standard certificated must be submiied alond with geniune certificated The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. |
| 79 | Supply & Erection of high power 90 Watt (Max) LED Street Light luminaries:LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3- 2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specifiedrating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) all relevant testing standard certificated must be submiied alond with geniune certificated . .Make twinkle, wipro, surya, Havells, Bajaj The work must be completed as per the entire satisfaction of Engineer-in-Charge. |
| 80 | Supply & Erecton of 36 Watt Surface Mounted linear wall washer section size should not more then 35mm. Optics 10/30, Degree, CCT-3000 kelvin, CRI>90, Macadam Step <3, IP-66. with Visor a length of 1000mm (1 Meter) is a standard archtitectural lighti ng fixture used to highlight building facades, textured walls, and landscape features. These lights typically feature a series of high-power LEDs (often 36 individual 1W LEDs) housed in a durable aluminum profile designed for heat dissipation and outdoor resilience. Make- Lafit Lighting, Mascon Lighting, Philips Lighting, Osram. |
| 81 | Supply, Erection, Testing & Commissioning of 12.5 Meter High Mast based on the following parameters/ requirements of the Deptt. i) Height of Mast: 12.5 meter with power tool based. The power tool 3 phase motorized 1.1 KW complete in all respect should be installed in the pole Reputed ISI marked only. ii) Wind speed: 180 Km/hour as per IS-875 (Part-III). iii) The High Mast & head frame shall be structurally suitable to accommodate the 6 Nos. LED flood light fittings & its control gear boxes include MCB TPN 63 Amp (Make L&T, Schinder, ABB ) for On/off lighting of High Mast iv) The entire high mast structure (Internally & externally) and all MS parts shall be hot dip galvanized as per BS EN ISO 1461. v) Construction of the Mast: The mast shaft shall be manufactured from high tensile steel plates confirming to BS EN 10025 having minimum yield strength of 355N/Sq. mm. Each mast shaft section shall be without any circumferential weld joint except base flange. The mast base flange shall be free from any lamination or incursion and provided with supplementary gussets between the bolt-holes to ensure elimination of helical stress concentration. The minimum A/F dimension of top shall be 200 mm (min.) and bottom 410 mm (min.). The mast should have 2 sections and the sections shall be joined at site by slip-stress-fit method and minimum overlap distance shall be 1.5 times the diameter at penetration. A door reinforced with welded steel section, vandal resistant, weather proof with Allen bolts and pad locking facility of dimension not less than 1050 mm x 225 mm shall be provided at a height 2 times the width of door from the base of mast to provide clear access to base compartment Equipments winch, motor, cable, connector etc. For the environmental protection of the mast, the entire fabricated mast shall be hot dip galvanized internally and externally in single dip having a uniform average thickness of 85 microns for plates more than 5 mm and 70 microns for 5 mm and less thickness.a) Code No.: I.S. 875 (Part III) 1987 Amended up to date Title: Code and practice for design loads for structures under b) Code No.: BSEN 10025 Title: Grades of M.S. plates c) Code No.: BS 5135/AWS D 1.1 Title: Welding d) Code No.: BSEN ISO 1461 Title: Hot dip galvanizing e) Code No.: TR. No. 7 (2000 addition) of ILE, UK. Title: Specification of Mast and foundation. f) Code No.: IS 3459 / 2266 Title: Stainless steel Wire rope g) Code No.: IS 9968 Part – 1 Title: Trailing Cable h) Code No. IS 325 Title: Motor |
| 82 | vi) Dynamic Loading for the Mast: The mast structure shall be suitable to sustain an assumed maximum reaction arising from a wind speed as per IS 875 (three second gust), and shall be measured at a height of 10 metres above ground level. The design life of the mast shall be 25 years. The force co-efficient taken for design of the twenty sided polygonal structure is to be established from the wind tunnel test data.vii) Luminaries Carriage: A fabricated Lantern Carriage shall be provided for fixing and holding the flood light fitting and control gear boxes. The Lantern Carriage shall be of special design and shall be of steel tube construction, the tubes acting as conduits for wire, with holes fully protected by grommets. The Lantern Carriage shall be so designed and fabricated to hold the required number of flood light fitting and control gear boxes, and also have a perfect self balance. The Lantern Carriage shall be fabricated in two / three halves and joined by bolted flanges with steel nuts to enable easy installation or removal from the erected mast. The entire lantern carriage shall be hot dip galvanized after fabrication. The inner lining of the carriage shall be provided with protective PVC arrangement, so that no damage is caused to the surface of the mast during raising and lowering operation of the carriage.Weather proof junction box, made of cast Aluminum shall be provided on the Carriage Assembly as required, from which the inter-connections to the designed number of the flood light luminaries and associated control gears fixed on the carriage shall be made.viii) (a) RAISING AND LOWERING MECHANISM: For the installation and maintenance of the luminaries and lamps, it shall be necessary to lower and raise the Lantern Carriage Assembly. To enable this, a suitable Winch Arrangement shall be provided, with the winch fixed at the base of the mast the specially designed head frame assembly at the top Winch: The winch shall be of “Integral Power Tool” type with motor. The winch shall have provision for manual operation in case of failure of the motor. The winch shall be double drum and completely self sustaining type, without the need for brake shoe, springs or clutches. Each driving spindle of the winch shall be positively locked when not in use. The capacity, operating speed, safe working load, recommended lubrication and serial number of the winch shall be clearly marked on each winch. The winch drums shall be grooved to ensure perfect seat for stable and tidy rope lay, with no chances of rope slippage. The rope termination in the winch shall be such that distortion or twisting is eliminated and at least 5 to 6 turns of rope remains on the drum even when the lantern carriage is fully lowered and rested on the rest pads. It shall be possible to remove the hoisting mechanism after dismantling through the door opening provided at the base of the mast. The winch shall be type tested at a reputed institution and the test certificate shall be furnished before supply of materials. The test certificate shall include the maximum load operated by the winch. |
| 83 | (b) Head Frame:The head frame is to be designed as a capping unit of the mast, shall be of welded steel construction, galvanized both internally and externally after assembly. The top pulley shall be of appropriate diameter, large enough to accommodate the steel wire ropes and the multi-core electric cable. The pulley block shall be made of no corrodible material, and shall be of die cast Aluminum Alloy (LM-6). Pulley made of synthetic materials such as plastic or PVC are not acceptable. Self-lubricating bearings and steel shaft shall be provided to facilitate smooth and maintenance free operation for a long period. The pulley assembly shall be fully protected by a canopy galvanized internally and externally. The head frame shall be provided with guides and stops with PVC buffer for docking the lantern carriage. (c) Stainless Steel Wire Ropes:The stainless steel wire ropes shall be in AISI 316 grade, 7/19 construction with central core in the same material of diameter and the breaking load of rope shall not be less than 2x1450 Kg. giving a factor of safety of over 5 for the system at full load as per the TR7 referred to in the beginning of this specification. The end construction of rope for the winch drum shall be fitted with talurit and for two continuous ropes the end termination in luminary’s carriage shall be with stainless steel thimble and copper splicing and for others with stainless steel thimble and bull dog grips. (d) Electrical System, Cable and Cable Connections:Suitable terminal box shall be provided as part of the contract at the base compartment of the high mast for terminating the incoming cable. The electrical connections from the bottom to the top shall be made by special trailing cable. The cable shall be EPR / PVC insulated and PCP sheathed to get flexibility and endurance. At the top there shall be weather proof junction box to terminate the trailing cable. The system shall have in-built facilities for testing the luminaries while in lowered position. Also, suitable provision shall be made at the base compartment of the mast to facilitate the operation of internally mounted, electrically operated power tool for raising and lowering of the lantern carriage assembly. The trailing cables of the lantern carriage rings shall be terminated by means of specially designed, metal clad, multi pin plug and socket provided in the base compartment to enable easy disconnection when required(e) Power Tool for the Winch:Three phase, single speed, 6 pole high-powered motor of rating 1 HP suitable to lift the load mounted on adjustable plate to adjust the length of winch motor coupling chain is to be provided in base compartment. Mechanical torque limiter is to be mounted on motor shaft to stop transmission of motion from motor to winch in case of excess load and thus prevent the damage to winch and breakage of rope. 01 no. 4 Pole MCB TPN used for on/off purpose of flood light. 40/63 amp to be installed in high mast for lighting (L&T/ ABB/ SCHNEIDER) |
| 84 | (f) Lighting Finial:i) One number heavy duty hot dip galvanized lightning finial shall be provided for each mast. The lightning finial shall be minimum 1.2 M in length and shall be provided at the center of the head frame. It shall be solidly bolted to the head frame to get a direct conducting path to the center of the earth through the mast. The lightning finial shall not be provided on the lantern carriage under any circumstances in view of the safety of the system ii) 1 Nos. LED type single dome aviation obstruction light shall be provided each high mast. (g) Earthing Terminals: Earth terminal using 12 mm diameter hot dip galvanized bolts shall be provided on the door stiffener of the mast for lightning and electrical earthing of the mast. (h) The firm will give the high mast parameters as given below: i) Height of the High Mast. = 12.5 Mtr. ii) Nos. of sections = 2 Nos. iii) Thickness of each section in mm. = Top: 4 mm & Bottom 4 mm minimum iv) Bottom plate thickness = 25 mm (Minimum) v) No. of rag bolts along with Anchor plate = 6 Nos. (Minimum) vi) Makes of High Mast = Valmount/ Bajaj/ Transrail/ BPP/ Utkarsh/Surya only. The manufacturer should be ISO 9001 certified having their own marketing division and project cell with adequate qualified and experienced Engineers to carry out the job and must have experience of handling similar turnkey jobs in past and the proof of the same is to be furnished for issue of tender documents. The bidder has to conduct wind tunnel test on a specimen to establish the force coefficients of the 20 side polygon and the value received from the wind tunnel test is to be taken in design. Further type test is to be done on a full size mast at SERC or other reputed institutions to validate the structural program. The winches are to be type tested through reputed institutions like IIT as consultants. The high mast manufacturer should have in-house civil, structural and product design facilities. Also the shaft is to be manufactured from ISO 9001, ISO 14001 and ISO 18001 certified factory taking care of all aspects of design, quality, environment and safety. |
| 85 | FOUNDATION FOR 12.5 Mtr. MTR. LONG HIGH MAST:Design & casting of foundation with M20 cement Concrete & steel reinforcement suitable for installation of 12.5 Mtr. / 16mtr high mast: |
| 86 | DSR ITEM NO. 2.8.1 (CIVIL WORK)Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kinds of soil (Size 1600mmx2300mmx2300mm) (Total 1.6mx2.3mx2.3m)= 8.46 cum (3 nos.x 8.46= 25.38 cum) |
| 87 | DSR ITEM NO. 5.9.1 (CIVIL WORK)Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete Size 1x2 (3.100+3.100) 0.45 = 7.88 sq.mtr. Size 1 - 1550mm x 900mm = (1.55mx0.9m) = (1.395x4=5.58 sq. mtr.) Size 2 - 250mmx2300mm = (2.3mx0.25m) = (0.515x4=2.3 sq. mtr.) Total (5.58+2.3= 7.88 Sq. mtr.) (3 nos.x 7.88= 23.64sq. mtr.) |
| 88 | DSR ITEM NO. 5.2.2 (CIVIL WORK)Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)Size 1 - 250mmx2300mmx2300mm = (0.25mx2.3mx2.3m) = 1.3225 cumSize 2 - 1550mmx900mmx900mm = (1.55mx0.9mx0.9m)= 1.25 cumTotal (1.3225+1.25= 2.57 cum) (3 nos. x 2.57= 7.71 cum) |
| 89 | DSR ITEM NO. 4.1.11 (CIVIL WORK)b) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) (0.1mx2.3x2.3m =0.52 cum) (3 nos. x 0.52= 1.56 cum) |
| 90 | DSR ITEM NO. 5.22.6 (CIVIL WORK)Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars1.Horizontal Bar10mm dia = 48 nos.x 2400mm= 115.2 r.mtr @ 0.62 Kg per mtr.= 71.42 kg2.Vertical Bar 12mm dia =20 nos.x2400mm= 48 r.mtr. @ 0.89 kg/mtr. =42.72 kg3.Horizontal Ring 8mm dia =10 nos.x3200mm=32 r.mtr.@ 0.390kg per mtr.=12.48kg Total (71.42+42.72+12.48=126.62+5% wastage = 132.95 kg) (3 nos. x 132.95= 398.85 kg) |
| 91 | Supply, Installation, Testing and Commissioning of Polycarbonate Junction box shall be insulated and made out of Polycarbonate with glass fiber reinforced. The size in mm should not be less then 155 x 210 x 92 cat. Part no KF1616. The Polycarbonate JB shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive. The Jb shall be rated for Degree of Ingress Protection IP 66/67 in accordance with IEC 60529. The gasket material shall be Polyurethane and the gasket shall be internally embedded. The JBs shall be comples with requirements of the Standards IEC 60998-1, IEC 60998-2-1, IEC 60670 - 22 & 60670 - 2.5. The manufacturer of Junction Box shall submite a copy of IEC Certificate. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-11, DIV VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested and Glow Wire test for 960 deg. Cent. The impact strength of polycarbonate enclosures i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. The connecting terminal cable entry should be fixed in junction box for incoming and outgoing. The box shall be Hensel/ Siemens/ Schneider/ ABB (size suitable for termination of 2 x 10mm2 Armoured aluminium cable). Manufacturer should submit routine test certificate for CJB/PJB. The job includes supply and fixing of MS clamp of required size. The clamps is to be fixed on the backside of the box including welding/ drilling of holes complete in all respect and to be fixed on LT- RCC/ Steel tubular pole/ Wall at as certain height upto the entire satisfaction of Engineer-in-Charge. |
| 92 | Protection Jali Size 12\\"x12\\"x12\\" [36 Watt Wall Washer Projection Light)] Supply, Erection, Testing & Commissioning of MS wire mesh for Protection of LED fitting of following size 16 guage frame with MS angle 40mm x 40mm x 6mm, MS Flat 20mm x 3mm size including cutting, welding etc. complete in all respect and to the entire satisfaction of Engineer-in-Charge. Including foundation making foundation of size 16\\"x16\\" of RCC mixture 1:2:4. The job includes cost of labor and other petty material request to complete job to the entire satisfaction of Engineer-in-Charge of the work. |
| 93 | Supply & Laying of flexible PVC insulated FR PVC sheathed 3 Core 1.5 mm2 Copper Cable conforming to IS - 694:2010 of make KEI/ Havell's/ Cirtina/ Finolex/ Lapp/ Polycab within the already erected 9 mtr Steel Tubular Pole and within bracket fitted on pole with the help of ladder/crane. The job include the cost of dismantling & re-erection fitting, bracket, managing traffic using proper precaution, making the required connection as started above and other petty material required to complete the job to the entire satisfaction of engineer-in-charge precautions of the work. |
| 94 | Supply & Erection of Three Phase Automatic Timer and Contactor assembled in 22 gauge CRCA sheet enclosure duly powder coated with the following accessories (Three Phase) of Make Amsons/ L&T/ Schenider or equivalent as approved by the Engineer-in-Charge. It shall conform to latest relevant IS Code:-1. It shall have 3 contactors of capacity 40 Amp. each of made BCH, Legrand, L&T or Siemons. The contractor should be of AC-3 duty 2 pole, 220/240 V coil Voltage.2. It shall have Auto/Manual switch, light activated switching system with allied accessories as required. 3. It shall have kit-kat fuse unit of 40 Amp capacity. The fuse unit shall conform to latest relevant IS code for protection of timers, bakelite sheet & other components as per requirement as site. 4. It shall be housed in a powder coated 22 gauge M.S sheet cabinet for its protection. 5.The device shall be provided/fixed in the existing pedestal box in such a way so that it operates at correct time i.e. at rising/setting of Sun. The Sensor shall be included time watch to operate as required. The work shall be executed to the entire satisfaction of Engineer-in-charge. Warranty:- IT SHOULD STAND WARRANTY FOR ONE YEAR TOWARDS ANY MANUFACTURING DEFECTS. |
| 95 | Supply installation and testing and commissioning of LED Flood Light, 200 watt powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000- 4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with 440 5 Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Make twinkle, wipro, surya, Havells, Bajaj Alll relevant testing standard certificated must be submiied alond with geniune certificated . The work must be completed as per the entire satisfaction of Engineer-in-Charge. |
| 96 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including 25 mm X 5 mm· G.l. strip in 40 mm dia G.l. pipe from earth electrode including connection with G.l. nut, bolt, spring, washer excavation and refilling etc.with charcoal/ coke and salt as required. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 97 | Supplying & laying of 3core X1.5Sq mm PVC copper conductor armoured cable loose in trench/pipe:-with ISI Marked in existing DWC pipe. Make sunhome, havells, polycab, KEI,The work shall be executed as per the entire satisfaction of Engineer in Charge.. |
| 98 | Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 degree Celsius to +50 degree Celsius. Jumbo frame: 9/10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP- MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL/EN, CE, FCC, RoHS and relevent MTCTE(TEC) BIS Certification/Complaince, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India, Make CISCO/Juniper/ HPE/ Extreme/ Alcatel/Arista/Lucent/D-Link. 8port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+ Make : CISCO/Juniper/ HPE/ Extreme/ Alcatel/Arista/Lucent/D-Link . The work shall be executed as per the entire satisfaction of Engineer in Charge.. |
| 99 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 3 Network Switch having features and specifications etc. as mentioned here under: At least 20 X RJ-45 Gigabit Ethernet Ports and additional 4 combo 10/100/1000 baset/ SFP Ports with additional 4 SFP+ ports non-blocking rchitecture by having Switching capacity of min. 128Gbps and packet forwarding rate of 95Mpps or gher, 16K MAC table. Console Port, USB port, Internal AC Power supply with operating temperature of 0to +50 degree Celsius. Stacking port with stacking support of minimum 8 units per stack. 48K Mac address, 9K or more Jumbo frame, ERPS with enabling ring to converge in less than 50 ms from node or link failure, Static routing, Static, 6to4, ISATAP and GRE, IPv6 Neighbor Discovery (ND), BGP, ISIS, MPLS, VRRP v2, OSPFv2/v3, PBR, Route Redistribution, RIPv1/v2/ng, IP Helper all L3 Protocols should support from day 1 for both IPv6 and IPv4, 802.1x, Port security , Radius C TACACS+ authentication C accounting, DAD, DAI, DoS attack prevention, SSH, Guest VLAN, IP Access List, MAC Access List. Multicast: VLAN, PIM-SM, PIM-DM, PIM- SDM, PIMSMv6, DVMRP v3 and MSDP, IGMP C MLD Snooping, Flow mirroring, IGMP C MLD Snooping Ǫuerier, Per-VLAN IGMP C MLD Snooping. SNMP, Dual configurations, Multiple images, RMON, LLDP/LLDPMED, sFlow, DHCP/BOOTP Client, IPv4/IPv6, Syslog server, Debug command, 802.3ah Ethernet Link OAM, 802.1ag Connectivity Fault, Y.1731 OAM, 802.1Ǫbb Priority- based Flow Control (PFC), DyingGasp, Cable Diagnostics , 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India.Make -CISCO/Juniper/ HPE/ Extreme/ Alcatel/Arista/Lucent/D-Link. The work shall be executed as per the entire satisfaction of Engineer in Charge.. |
| 100 | Supplying, Installation, Testing and commissioning of small form plugable (SFP) for network switches must be hot plugable, RoHS complaint etc complete as required 1G Copper/SFP. Make:-CISCO/Juniper/ HPE/ Extreme/ Alcatel/Arista/Lucent/D-Link.The work shall be executed as per the entire satisfaction of Engineer in Charge. |
| 101 | Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. Copper Patch Cords of length 3m (10ft) Make : Molex, Systimax, R&M, Siemens, Beldon, Panduit, D-Link. The work shall be executed as per the entire satisfaction of Engineer in Charge. |
| 102 | Supplying, drawing, Installation, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non-Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA- 568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL. 1 Run of cable.Make:-CISCO/Juniper/ HPE/ Extreme/ Alcatel/Arista/Lucent/D-Link. The work shall be executed as per the entire satisfaction of Engineer in Charge. |
| 103 | Supplying, Installation, Testing and commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. Make Molex, Systimax, R&M, Siemens, Beldon, Panduit, D-Link. The work shall be executed as per the entire satisfaction of Engineer in Charge. |
| 104 | Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 deg C to +50 deg C and Storage Temperature shall be – 5 deg C to +50 deg C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 µm and 125 ± 0.7 µm corrospondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cut-off wavelength < 1260 nm etc complete as required. Single Mode Optical 6 Core fiber cable.Make Molex, Systimax, R&M, Siemens, Beldon, Panduit, D-Link. The work shall be executed as per the entire satisfaction of Engineer in Charge. |
| 105 | Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre- assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting screws, and spiral wrap tube etc complete as required. 6Port LIU. Make D-LINK/ DYNAMIC/ CCI/ APW/ Beldon/Syrotek/ rattal, comrack. The work shall be executed as per the entire satisfaction of Engineer in Charge. |
| 106 | Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre- assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting screws, and spiral wrap tube etc complete as required. 24Port LIU. The work shall be executed as per the entire satisfaction of Engineer in Charge. Make D-LINK/ DYNAMIC/ CCI/ APW/ Beldon/Syrotek/ rattal, comrack The work shall be executed as per the entire satisfaction of Engineer in Charge. |
| 107 | Supply and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 μm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R <25mm, Repeatability < 0.2 db, Working ambient Temperature – 5 deg C to +50 deg C, Storage Temperature – 10 deg C to +50 deg C, Length -- 2meter, Type -- LC-LC Duplex etc complete as required Make Molex, Systimax, R&M, Siemens, Beldon, Panduit, D-Link .The work shall be executed as per the entire satisfaction of Engineer in Charge. |
| 108 | Supply and fixing 42U Rack with 6 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1.6mm CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 8nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. Make Molex, Systimax, R&M, Siemens, Beldon, Panduit, D-LinkThe work shall be executed as per the entire satisfaction of Engineer in Charge. |
| 109 | Supply and fixing Outdoor Polel mount 9U Rack, IP55, Front Door with Filter, Louver & Unique key Lock. 3 Socket PDU 5Amp - 1 No. Self adhesive thermal foam from inside. Hood For Air Inlet at front side.1U Cantilever Tray 250mmDepth, Gasket. etc complete as required. Make D-LINK/ DYNAMIC/ CCI/ APW/ Beldon/Syrotek/ rattal, comrack The work shall be executed as per the entire satisfaction of Engineer in Charge. |
| 110 | Supplying Installation Testing and Commissioning of 8 MP IP IR Outdoor Bullet Camera having following spcifications and features etc :- 8 MP (3840 × 2160) or better IP IR 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens outdoor Bullet Camera.1) Type of Camera: Outdoor Bullet Camera2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition3) Signal System: PAL/NTSC4) Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both.7) Signal to Noise Ratio: > 50 dB8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt Smart IR LED's with effective distance upto 50 Meter integrated IR and 30 meter for colour view in night9) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A,G.711Mu, G.726, AAC, G.72310) Wide Dynamic Range: WDR (120dB or more)11) Digital Noise Reduction: DNR (2D/3D) On/Off12) Streaming: Triple streaming, configurable13) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 8MP (3840 × 2160)@20 fps, Sub streams: 4MP (2688 ×1520)@25/30 fps & D1@25/30 fps;14) Image Setting: Rotate Mode, saturation, brightness, contrast,sharpness adjustable through client software or web browser15) Profile Management: User configuration import, export329 DELHI ANALYSIS OF RATES (E&M) 202516) Security: User Authentication, Digital Water Marking17) Onboard Storage; Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.18) Recording Management: Format SD, overwrite, storage management, video to NAS device,19) Edge Analytics: Tripwire, Intrusion, Motion Detection20) Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection21) Alarm Support: It should have 1/1 Alarm In/ Out Port22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compreesion Network Compatibility23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP,HTTPS, SNMP , TCP/IP, PPPoE, NFS, UDP, ICMP, |
| 111 | SSL, DHCP, SMTP, RTSPS, unicast,24) User Access: Minimum 08 Users25) System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF official website (All the certifications & Credentials should be valid on the date of technical evaluation).26) VMS: Camera shall support open source VMS27) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade.28) Ethernet: 1 RJ 45 10/100 Ethernet port29) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source.30) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE31) Enclosure: IP67 weather proof, IK1032) Operating Condition: Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)33) IR life: 40000 hours or higher34) Video Bit rate: 32 KBPS - 8 MBPS or better35) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS 35) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS. Make Honeywell/ CP Plus/Matrix/ Prama The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 112 | Supplying Installation Testing and Commissioning of 8 MP IP IR Dome Camera having following specifications and features etc :- 8 MP (3840 × 2160) or better IP IR 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) Dome Camera,1) Type of Camera: Dome Camera2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition3) Signal System: PAL/NTSC4) Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, DigitalWatermarking.6) On Screen Display: Camera should display Camera title, Date &Time in live & recorded video both.7) Signal to Noise Ratio: > 50 dB8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Meter integrated IR and 30 meter for colour view in night.9) Video Compression (Minimum): H.265 or better,Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72310) Wide Dynamic Range: WDR (120dB or more)11) Digital Noise Reduction: DNR (2D/3D) On/Off12) Streaming: Triple streaming, configurable13) Video Streaming & Frame Rates: Triple streaming , configurable Main stream: 8MP (3840 × 2160)@20 fps, Sub streams: 4MP(2688×1520)@25/30 fps & D1@25/30 fps;14) Image Setting: Rotate Mode, saturation, brightness, contrast,sharpness adjustable through client software or web browser15) Profile Management: User configuration import, export16) Security: User Authentication, Water Marking17) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.18) Recording Management: Format SD, overwrite, storage management, video to NAS device,19) Edge Analytics: Tripwire, Intrusion, Motion Detection20) Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection21) Alarm Support: It should have 1/1 Alarm In/ Out Port 327 DELHI ANALYSIS OF RATES (E&M) 202522) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compreesion23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, |
| 113 | SSL, DHCP, SMTP, RTSPS, unicast,24) System Capability: ONVIF25) VMS: Camera shall support open source VMS26) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade.27) Ethernet: 1 RJ 45 10/100 Ethernet port28) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE—to ensure continuous operation in the event of a failure in one power source. 29) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE30) Enclosure: IP67 weather proof, IK1031) Operating Condition: Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)32) IR life: 40000 hours or higher33) Video Bit rate: 32 KBPS - 8 MBPS or better34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS. Make Honeywell/ CP Plus/Matrix/ Prama The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 114 | ANPR Camera: Supply installation Testing and Commissioning of commercial grade , 4MP IR IP H.265 Bullet/Box ANPR Camera with 10-50mm Lens, multiple Stream, WDR/HLC/ BLC, Video Encryption (AES/TLS/SRTP), SD Card Slot (support up to 256GB), 30 meter (Internal/External) IR, PoE,Alarm Interface 1 Input / 1 Output, Built-in/ external Surge Protection. ONVIF, Color: 0.005 lux and 0 Lux with IR. Certifications - UL, CE, FCC, IP67,IK10 & BIS. Cyber Security/Information Security Certificate. OEM Should have ISO 9001, ISO 14001, ISO 45001. Software Specs on board or through VMS : Supplying, Installation, Testing and commissioning of Automatic Number Plate Recognition Software/ inbuilt Smart Analytics and all required software/Hardware shall be Quoted Along in the price. The ANPR Application shall automatically detect the License plate in real-time. ANPR Application shall be designed to work for 24x7 unattended operations. The ANPR Application shall have more than 95% Accuracy during daytime and 85% during night-time for all different types and classes of vehicles. The ANPR Application should Detects for both Standardized (High Security Registration Plates) and Non-Standardized plates. Supplying, Installation, Testing and commissioning of 4MP IR IP H.265 Bullet/Box ANPR Camera with 10-50mm Lens Make Sony/ Bosch/ Nordon/ AXIS/ PELCO/Honeywell/ CP Plus/Matrix/ Prama . The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 115 | Supplying Installation Testing and Commissioning of PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :- 4 MP IP IR motorized PTZ (4MP @25/30fps or better) camera, Triple streaming , configurable on resolution Main stream: 4MP@25/30 fps Sub streams :1080p@25/30 fps & D1@25/30 fps or better, varifocal lens 4.5-135mm or better with Automatic & manual Focus Adjustment provisions, 30x Optical zoom and 12x Digital zoom with angle of viewH : 57˚–2.4˚, m, PAN Travel: Pan: 0° ~ 360° endless;Manual Pan: 300° /s, Preset : 300° /s, Tilt Travel: Tilt: 0-90°, auto flip 180°, Manual Tilt: 200° /s, Preset : 300° /s1) IP IR PTZ Camera: Motorized PAN TILT ZOOM with IR2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS3)Signal System: PAL/NTSC4) Minimum Illumination: 0.008 Lux@ F1.6, AGC ON,, 0 lux with IR, or better5) Imaging: 1/1s to 1/30000s, Auto Gain Control , White Balance- Auto,Back Light Compensation, Image Rotation, Multi zone Privacy Masking (Upto 24 Area), HLC, Defog, Region Of Interest and EIS features.6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both.7) Signal to Noise Ratio: > 50 dB8) Event Notification: Through Relays, E-Mails or FTP9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective 331 DELHI ANALYSIS OF RATES (E&M) 2025 distance. The camera should have IR LED’s and cover distance up to150 meter or above10) Auto Tracking: The camera should be equipped with Deep-learningbased auto tracking function using imultaneously all of the panning, tilting and zooming should be available. When a motion is detected in aregistered monitoring area, the camera should track the motion (object) and capture it.11) Pre/Post Event Buffering: The camera should support atleast of 5 seconds of pre & post event buffering.12) Presets: 300 Presets13) Video Compression (Minimum): H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72314) Wide Dynamic Range: WDR (120dB or more), HLC & BLC15) Digital Noise Reduction: DNR (2D+3D) On/Off16) Image Setting: Rotate Mode, ROI ,EIS, Defog, saturation, brightness, contrast, sharpness adjustable through client software or web browser17) Profile Management: User configuration import, export18) Cyber Security: Configuration encryption, AES 256-bit Encryption, Digest, account lockout, video encryption, IP/MAC filtering, trusted boot, trusted upgrade, trusted execution19) Onboard Storage: Camera should support built in Micro SD/SDHC/SDXC Card slot upto 512 GB . It should be |
| 116 | supplied with minimum 128GB Memory.20) Recording Management: Format SD, overwrite, storage management, video to NAS device, remote archive access via FTP login21) Edge based Video Analytics & Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection, Tripwire, Intrusion, ObjectAbandon/ Missing, SMD, Face Detection Network Compatibility22) Network Protocol: SFTP, IPv6, IPv4, DNS, NTP, HTTP, HTTPS, SNMP, TCP/IP, PPPoE, NFS, ICMP, DHCP, SMTP, RTSPS.23) System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF official website (All the certifications & Credentials should be valid on the date of technical evaluation).24) VMS: Camera shall support open source VMS25) Connectivity: 1x LAN RJ-45 (10/100Base-T)26) Audio Support: Audio Interface : The camera should have 1/1 Audio In/Out to connect External Mic and Speaker Audio Compression : PCM, G.711U/A, G.711MU, G.726, MPEG2-Layer2, G.722.127) Alarm In/Out : Alarm In/out- 7/2 Ch In/Out28) Power Input: The camera should support simultaneous dual power input—DC/ AC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source.29) Power Requirement: 24 VDC, 2.5 A (± 25%), PoE+ (802.3at)30) Enclosure & Weather Proof Standard: IP67 weather proof and IK10, TVS 8000V lightning proof, surge protection, voltage transient protection 33231) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)32) IR life: 40000 hours or higher33) Video Bit rate: 32 KBPS - 8 MBPS or better34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS. Make Sony/ Bosch/ Nordon/ AXIS/ PELCO/Honeywell/ CP Plus/Matrix/ Prama The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 117 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below :1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth.2) NVR should support video compreesions : H.265 or better, MJPEG.3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio compressions.4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10.6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)8) Video Output Ports: 2x HDMI and 2 VGA9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc. 10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF 21.12 (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need.13) Standards: CE, FCC, RoHS, BIS Certified14) Power Supply : Should support AC100-240V, 50/60Hz Power supply.15) Operating Condition : -5°C to 50°C, humidity 90% (max) (noncondensing)16) The VMS application shall support all the features & functionalities of the offered cameras.17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses , with no dependency ofVMS licenses by binding with the MAC address of the cameras to achieve the functionality.18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage.19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode |
| 118 | 21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm24) It should have Web and GUI interface.25) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection26) Face Recognition Database Capacity: It should support total Blacklist nd Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries & regions and state to each face image.27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes.29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.31) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.32) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency 33) VCA (Video Content Analytic): Should support multiple videocontented analytics based on camera analytics 34) Analytics by NVR: Perimeter protection and face recognation. Make Sony/ Bosch/ Nordon/ AXIS/ PELCO/Honeywell/ CP Plus/Matrix/ Prama The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 119 | 32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16. The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 120 | 64 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/36/64, 2nd screen: 1/4/8/9/16. The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 121 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. 6TB (Terabytes) Make : WD/ Toshiba/ Segate. The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 122 | Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required 55 inch or larger. Make Sony, Samsung, LG. The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 123 | Supplying & Fixing of Online UPS - Input supply: Single Phase, Output Supply: Single Phase.Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 °C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . TheUPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc Make APC Schneider, Legrand-Numeric , Emerson-Vertiv/ Microtek/ Eaton. The work shall be executed as per the entire satisfaction of Engineer in Charge6KVA |
| 124 | 10 KVA |
| 125 | Supply and fixing of wheather proof Protection boxes for All cameras, PVC Square Junction Box for CCTV Camera Mounting 4X4\\" with Cable glands and gasket seal for extra protecting, Col White/Cream shell be executed to the entire satisfaction of Engineer-in charge. |
| 126 | Pole 5 MTR: Supply Installation & Commissioning of L Shaped Pole 5 mtr with foundation 3feet / Earthing with complete all other accessories of Pole if any. Termination box(Indoor/ Outdoor) as per site requirement. Pole shall be able to withstand high wind speed during service and it is to be ensured that video feed quality is not impacted due to wind in different climatic condition. Rate includes the painting/ numbering if any. Pole should be hot dip galvanised Make Utkarsh, Bajaj, BPP, Translane,Wall mount. The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 127 | Pole 5 MTR with T brackets: Supply Installation & Commissioning of L Shaped Pole 5 mtr with foundation 3feet / Earthing with complete all other accessories of Pole if any. Termination box(Indoor/ Outdoor) as per site requirement. Pole shall be able to withstand high wind speed during service and it is to be ensured that video feed quality is not impacted due to wind in different climatic condition. Rate includes the painting/ numbering if any. Pole should be hot dip galvanised Make Utkarsh, Bajaj, BPP, Translane,Wall mount. The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 128 | Pole 7 MTR: Supply Installation & Commissioning of L Shaped Pole 7mtr with foundation 3feet / Earthing with complete all other accessories of Pole if any. Termination box(Indoor/ Outdoor) as per site requirement. Pole shall be able to withstand high wind speed during service and it is to be ensured that video feed quality is not impacted due to wind in different climatic condition. Rate includes the painting/ numbering if any. Pole should be hot dip galvanised. Make Utkarsh, Bajaj, BPP, Translane,Wall mount. The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 129 | Supply installation, testing and commissioning of Split AC 1.5 Ton , Computer (Supply, Installation, Testing and Commissioning of Client Desktop PC with Core i7 processor, 16GB RAM, | 512 SSD and 1TB HDD, Windows 64 bit OS, external DVD writer, wireless Keyboard, wireless mouse, 4GB Graphics card with dual monitor support, complete with high quality 5 mtrs HDMI cables for connecting displays complete as required.) (A.C Make Hitachi, carrear, Voltas, LG, Samsung, Harriar,loyad.The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 130 | 1 Nos. CCTV Cameras Operation Resident Engineers(8-10Hours per person) per day for two year (24 month) |
| 131 | Supply installation, testing and commissioning of Network Horn Speaker, POE wall mount, 30watt HDSpeaker, Weather Proof speaker. Network Speaker is an all-in-one speaker system connected with a single network cable. Make Axis/modern, Boosh,Hikvision, Dasscon, JB/Honeyweel, Marshall,Sony,The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 132 | Supply installation, testing and commissioning of 15 license configurred and expandible to 50 License Paging server for 50 paging points, Group Announcement, Zone Announcement, Support Multiple Zones, Individual Announcement, Group Hunting, Operator Panel, GUI Based etc Make Axix/Norden/Hikvision/Dasscom/TOA. The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 133 | Supply installation, testing and commissioning of Network Based Paging Microphone Equipped with a 7-inch highdefinition Touch display with goosenech Microphone, Alarm Input/Output.Make Axix/Norden/Hikvision/Dasscom/TOA The work shall be executed as per the entire satisfaction of Engineer in Charge |
| 134 | 1st Year (CMC rates) |
| 135 | 2nd Year (CMC rates) |
| 136 | 3rd Year (CMC rates) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail