| 1 | Dismantling of pucca brick work or lime work including stacking serviceable materials in countable stacks within 15m lead and disposal of unserviceable materials with all leads and complete as per directions of E/I [ 5.10.1] |
| 2 | Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of excavated earth within intial lead and lift as per specification and direction of E/I. (i) For classification of soil item -A.[JSOR DWSD- 3.3.1(i)] |
| 3 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance of 50m including all lifts, levelling, ramming the foundation trenches, removing roots of the tree, shrubs all cpmplete as per approved design, building specifications and directions of E/l …..do….do….. specification and direction of E/I. Extra for earthwork in hard soil.[BCD SOR -5.1.1+5.1.2 ] |
| 4 | Providing course clean sand in filling in foundation tranches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building a specification and direction of E/I.[BCD SOR-5.1.10] |
| 5 | Providing designation 75B one brick on flat soling joints filled with local sand including cost of watering taxes royality all complete as per buinidng specifiacation and direction of E/I.[BCD SOR-5.6.3] |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement – All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) [SOR BCD 5.3.9.1] |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) [SOR BCD 5.3.10] |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) [SOR BCD 5.311] |
| 9 | Providing Tor steel of reinforcement of 10mm,12mm &16mm dia. Bars as per approved design and drawing ......... do ........ do ...........E/I.[ BCD SOR- 5.5] |
| 10 | 8 mm dia main bar [5.5.4] @ 0.395kg/m |
| 11 | 10 mm dia main bar [5.5.5 b] @ 0.617kg/m |
| 12 | 12 mm dia longitudinal bar [5.5.5 a] @ 0.890kg/m |
| 13 | centering and shuttering including strutting and propping etc and removal of form for foundation….do…do…E/I [5.3.17.1] |
| 14 | Earthwork in back filling the trench after laying different types and sizes of R.C.C. spun pipes …do..do..E/I.[JSOR DWSD-3.3.2] |
| 15 | Disposal of excavated earth in borrow area of lead 1km(k) +2km(p) ( Add 50% extra for loose volume) |
| 16 | Providing and laying 80 mm thick factory made cement concrete interlocking paver block of M-40 grade made by block making machine with strong vibration compaction, of approved size, design and shape, laid in required colour and pattern over bed as per relevant IRC Code, filling the joints with fine sand etc., all complete as per direction of Engineer-in-charge SOR(4.23B) |
| 17 | Taking down chaukhats in door including stacking serviceable materials…do…do E/l [sor bcd 5.10.11] |
| 18 | Taking down chaukhats in window including stacking serviceable materials…do…do E/l [sor bcd 5.10.11] |
| 19 | Providing two coat of plastic emulsion paint of approved shade and make over old surface including washing, cleaning, and preparing the walls , scaffolding, washing the floor and taxes all complete as per building specificatons and directions of E/l [bcd 5.8.20] |
| 20 | Putty [M-243 ] @ 20 sqft per kg |
| 21 | Providing primer one coat of approved shade and make over new….do….do… E/I [bcd 5.8.26] |
| 22 | Providing, supplying & spreading of stone dust in filling in foundation tranches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of material, labour,royalty and taxes all complete as per specifications and directions of E/I. ( mode of measurement compacted volume) RCD 4/M004 |
| 23 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:1.5:3 (1 Cement : 1.5 coarse sand :3 graded stone aggregate 20mm nominal size) [BCD SOR - 5.3.1.1] |
| 24 | Labour for scrapping old paint with paint remover and below lamp as required on wooden or steel surface including cost of all labour and materials and scaffolding all complete as per building specification and direction of E/I. [BCD 5.8.40] |
| 25 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface…do…do E/I [5.8.45] |
| 26 | upplying fitting and fixing M.S. 40x40x4mm is2062 Grade A M.S. angle, hoisting steps, welded with 6mm dia and 75mm long M.S. rods, anchorage fixed in concrete steps at the time of casting including taxes all complete as per direction of E/l.[bcd 5.5.33] |
| 27 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat/squqre bar as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. [5.5.12] |
| 28 | Supplying, fitting and fixing fully glazed sleel door,window or ventilation of standard rolled 'Z' and mullion steel section and size as per IS-1038 joints met and welded with 100x16x3mm M.S. lugs fixed in cement concrete (1:2:4) blocks 15x10xx10cm, size including cost of oxidised iron fittings with hinges, handles per steps, catch springs, 3mm thick plain glass panes with Aluminium beads and inner frame fixed with lugs with 20mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction and of E/I. [5.5.18] |
| 29 | Supplying fitting and fixing 35mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handles, cleats and sand blocks and taxes all complete as per building specification and direction of E/l.[5.4.32] |
| 30 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing, polishing and cost of curing taxes, and all complete as per building specification and direction and of E/I. (i) With \\"A\\" grade white Tiles.[bcd-5.6.23.1] |
| 31 | Ceiling Fan (1400 mm) [M-773] |
| 32 | 9/10 w led bulb [M-855] |
| 33 | Suppying and fixing angle holde rincluding connection etc as required [1.34] |
| 34 | Carriage of Materials |
| 35 | Sand 1Km(K) + 5Km(P) |
| 36 | Cement 5Km(P) |
| 37 | Chips 1Km(K) + 40Km(P) |
| 38 | Bricks 1KM(k) +7 KM (p) |
| 39 | Reinforcemet bar 5KM (p) |
| 40 | Add 18% GST |
| 41 | Adding Labour Cess @ 1% |
| 42 | For Sign board and Photography Please Enable Macros to View BoQ information |