| 1 | Providing, painting,finishing walls with two coats of anti-algae, weather proof acrylic smooth emulusion paint of approved make with silicon additives on sand face plaster/ plain plaster & concrete surfaes of required shade over new work over a base coat of exterior cement primer including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge. |
| 2 | Providing and fixing double tubular scaffolding system using H- frames with cup lock type on the exterior side upto seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and as approved by the Engineer -in - charge. The elevational area of the scaffolding shall be measured for payment purposes. The payment shall be made once irrespective of duration of scaffolding |
| 3 | Providing and fixing PVC rain water pipes conforming to relevant IS type B and PVC SWR fittings & specials conforming to relevant IS including jointing with seal ring / With PVC solvent adhesive including fixing in walls using clamps etc complete all as per drawings, specifications and as directed by the Engineer-in-charge |
| 4 | SWR PIPE 110 mm O/D |
| 5 | Providing and applying wall painting two coats on new work with premium plastic emulsion paint of approved brand to give an even shade, including a coat of approved cement primer, including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge |
| 6 | Providing SFMC Micro concrete for strengthening of structural members including mixing, pouring, curing as per manufacturer specifications and as directed by the Engineer-in-charge |
| 7 | Using SFMC with 50% Quartz aggregate by weight (Only SFMC consumed alone will be measured for payment) |
| 8 | Providing 20 mm thick plastering using Ready mix external plastering compound of approved make for external faces of brickwork / concrete surfaces including preparation of the surface, curing, cleaning scaffolding up to 10 metres height complete.all as per specifications including forming drip moulds wherever necessary and as directed by the Engineer-in-charge |
| 9 | Extra for cement punning for all types of mixes complete all as per specifications and as directed |
| 10 | Providing and laying in position cement concrete of 1:2:4 (1 cement, 2 crushed sand, 4 graded stone aggregate of nominal size 20 mm) including consolidation, finishing, curing etc. complete as per specification and drawings but excluding the cost of Formwork shuttering, centering and steel reinforcement at all Level. Note :The minimum cement content for cement concrete works should be as per the latest revision of the relevant IS code. |
| 11 | Providing and laying in position Reinforced Cement Concrete (RCC) of grade M-30 using 20mm maximum size aggregates and crushed sand of approved quality including admixtures of approved brand and quality (plasticiser or super plasticiser) if required, including weigh batching, mechanical mixing, transporting, placing, vibrating, consolidation, finishing, curing etc. complete but excluding the cost of centering, shuttering and reinforcement complete as per specifications up to Plinth Level. Note :The minimum cement content for RCC works should be as per the latest revision of the relevant IS code. |
| 12 | Extra for RCC Using Ready Mix Concrete from outside project area including transporting and pumping from approved batching plants . |
| 13 | Providing, supplying and laying heavy duty paving tiles for parking area, footpath, plinth protection area etc. meeting all the technical specifications as per relevant codes and standards of size 300x300mm/250x250mm with minimum thickness of 10 mm/20 mm laid over cement mortar 1:4 up to 30 mm thick bedding, setting with cement slurry, closed jointed, as per finished levels, slope etc. including, grouting the gaps between tiles as per manufactures specification, curing cleaning and fixing to required level complete all as per manufacturers specifications and as directed by the Engineer-in-Charge. |
| 14 | Providing and applying white cement based wall putty of approved make over concrete or Plastered surface up to 3 mm thick to get uniform surface free from undulation including cleaning complete all as directed by the Engineer-in-charge |
| 15 | Providing and Painting with Epoxy PU paint using 2 coats of (120 Micron dry film thickness) coating as finishing coat over a priming coat of of 50 micron thickness over steel surfaces at all locations prepared and applied as per manufacturer' specifications including preparation of surface by cleaning with wire brush and rubbing, scraping , applying sand paper , making free of Rust, dust, dirt etc. filling the holes, joint, cracks if any using epoxy putty complete. all as per manufacturers technical data and as directed at site to achieve minimum overall dry Film thickness of 170 micron (50 Micron primer Coat + 120 micron finishing Coat). On STEEL surfaces |
| 16 | Providing , centering ,shuttering Form work using PVC film faced plywood to get a neat form finish surface for all types of structures including necessary strutting, proping, staging, supports etc and deshuttering the same after the specified time all as per drawings, specifications and as directed by the Engineer-in-charge at all levels |
| 17 | For Sub Structure |
| 18 | For Super Structure |
| 19 | Providing and laying water proofing treatment in sunken portions of WCs, bath rooms etc. by appying cement slurry mixed with water proofing cement compound consisting of applying: (a) 1st layer of slurry of cement @ 0.488 kg / sq.m mixed with water proofing cement compound @ 0.253 kg per sq.m. including injecting cemnt slurry .This layer will be allowed to air cure for 4 hours. (b) 2nd layer of slurry of cement @ 0.242 kg / sq.m mixed with water proofing cement compound @ 0.126 kg / sq.m. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with cement slurry. Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (using crushed sand) admixed with proprietary water proofing compound conforming to relevant IS and approved by Engineer-in-charge including mixing 'RECRON 3S' fibre at the rate of 125 grams per 50 kg of cement in top layer of plaster and finally finishing the surface with trowel with neat cement slury in bottom and all the sides of sunken portion. complete as directed by the Enginer-in-charge. The treatment to be tested for water tightness before filling the sunken areas. |
| 20 | Providing and laying minimum 25 mm thick uniform shade Kotah stone flooring over 20 mm thick (Avearge) base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing in minimum three levels to obtain mirror polish complete with base cement mortar 1:4 (using crushed sand) all as per specifications, patterns and drawings complete. |
| 21 | Providing and Laying Minimum 25 mm thick uniform shade Kotah stone treads and risers of steps, skirting,window sills in single length up to 2.00 metres length slab dado and pillars laid on 12 mm thick (average) cement mortar 1:3 (using crushed sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing to obtain mirror finish complete as per specifications, drawings and as directed by the Engineer-in-charge |
| 22 | Painting (two coats) on rain water, soil, waste and vent pipes of 100 mm Dia and fittings with black anticorrosive bitumastic paint of approved brand and manufacturer over and including a priming coat of ready mixed zinc chromate yellow primer on new work Pipes of all diameter including preparation of the surfaces, scaffolding complete. as per specifications and as directed by the Engineer-in-charge |
| 23 | Providing and Fixing 3.00 mm thick Homogeneous PVC sheet / tile in flooring and skirting of aproved make in approved pattern on a smooth and damp prrof base using rubber based adhesive of approved manufacture including levelling small undulations with plasterof paris if required, rolling with light wooden roller weighing about 5 kg all complete as directed by Engineer-in-charge in approved colour and shade |
| 24 | Dismantling of RCC works carefully manually without damaging adjacent structures excluding cutting of reinforcement including stacking of steel reinforcement bars and disposal of unserviceable materials within 200 m lead as per direction of Engineer-in-charge |
| 25 | Dismantling plain cement concrete manually / by mechanical means carefully without damaging adjacent structures including disposal of debris within 200 m lead as per direction of Engineer-in charge |
| 26 | Supplying man power along with necessary spades, shovels, punjas, ropes, small special spades, rain coats, broom, mop etc, minimum two labours per day and maximum any number of labour as and when decided by Engineer Incharge to work for eight hours per day to carry out the cleaning work, loading work etc as directed by Engineer Incharge. Please Enable Macros to View BoQ information |
| 27 | Supplying man power along with necessary spades, shovels, punjas, ropes, small special spades, rain coats, broom, mop etc, minimum two labours per day and maximum any number of labour as and when decided by Engineer Incharge to work for eight hours per day to carry out the cleaning work, loading work etc as directed by Engineer Incharge. Please Enable Macros to View BoQ information |