Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #56108298

Tender For Special Repair Of Bldg No. Ht-150 And Ht-151 (Rice Shed) Of Coy Asc (Sup) Type F Under Ge(N) Ambala Cantt

Issued by Statutory Bodies & Commissions/Committees · Ambala, Haryana
Tender Value
20.08 Lakhs
Estimated cost
Bid Submission
13 Jul 2026
9 days left
EMD
40160
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ambala → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair Of Bldg No. Ht-150 And Ht-151 (Rice Shed) Of Coy Asc (Sup) Type F Under Ge(N) Ambala Cantt

BOQ

Name of Work:- Special repair of bldg No. HT-150 and HT-151 (Rice Shed) of Coy ASC (SUP) Type F under GE(N) Ambala Cantt
Sl. No. Item Description
1Schedule 'A' Part-I (B/R itmes)Dismantling asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings complete all as specified and as directed.
2Supply and fixing Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick having zinc coating 150 grams per Sqm (Az 150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall curved/lgloo type curved structure of minimum radius not exceeding 6 metre,fixed with self tapping screws complete all as specified and as directed.
3Supply and fixing Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa having zinc coating 150grams/Sqm (Az-150) as in roof ridge,valley gutter etc fixed with self tapping screws complete all as specified and as directed.
4Demolition of cement concrete (un–reinforced) in ground floors and pavings not exe 15 cm thickness (below or above ground level) complete all as specified and as directed.
5Preparing disturbed surface of earth incl well ramming and watering as required complete all as specified and as directed.
6Material and labour for treating the top surface of compacted earth at the rate of 5 litres of emulsion per square metre of surface using Chlorophosphorus 20EC complete all as specified and as directed.
7Material and labour for providing PCC (1:4:8) Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and as directed.
8Material and labour 100 mm thick PCC 1:4:8 Type D–2 using 40mm graded crushed stone aggregate as in floor etc. and finished even and fair without using extra cement complete all as specified and as directed .
9Material and labour machine cut kota stone slab 18 to 22 mm thick (size of each slab not less than 550mm x 550mm) in floor, set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 15-20 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
10Material and labour machine cut kota stone slab 18 to 22 mm thick ( kota stone shall be cut from size not less than 550mm x 550mm) in skirting , set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 10 mm thick rendering in CM 1:4 complete all as specified and as directed.
11Material & Labour providing 75 mm thick cement concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregates as in plinth protection, laid in alternate bays (not exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work, complete, all as specified and as directed.
12Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed
13Material and labour brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed .
14Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed.
15Material and labour for rendering 15mm thick in cement plaster (1:6) on any faces of brick work or concrete wall surfaces and finished even and smooth without using extra cement including necessary scaffolding etc complete all as specified and as directed.
16Material and labour for preparation of new plastered surface of ceilling applying three coat white wash complete all as specified and directed.
17Taking down MS sliding shutters of any description exc 10 sq. m but n.exc 15 Sqm each and refixing in same position after greasing etc.complete all as specified and as directed.
18Material and labour for 02 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer as in roof, wall etc.complete all as specified and as directed.
19Dismantling kota stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in cement mortar., complete all as specified and as directed.
20Material and labour preparation of old decorated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
21Taking down existing 600mm dia turbo ventilator, carefully from roof without damaging the existing ventilator and refixing the same ventilator on roofing structure including necessary alingment, fastening screws, sealent application, waterproofing treatment around base, replacement of minor consumables such as nuts, bolts, rubber washers and sealent complete in all respect as specified and directed .
22Schedule 'A' Part-II (E/M itmes)Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc., complete all as specified and as directed .
23Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. for one light/fan/exhaust fan/bell point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
24Description all as per serial item No.23 here-in-before but for One 3 pin, 6 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed.
25Description all as per srl item No 23 here-in-before but for one socket outlet 16 Amp with 4.00 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4.00 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly, complete all as specified and as directed by the Engineer-in-Charge.Note : (i) Point wiring shall be done in a manner that not more than 01 socket point executed in one circuit.(ii) Each socket point will be measured and paid as per point.
26Supply and fixing of modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts, complete all as specified and as directed.
27Supply and fixing of modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed.
28Supply and fixing of modular socket outlet multipin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed.
29Supply and fixing of modular socket outlet multipin combined, (6pin), 6/16 Amp, one way, two module, 230 volts complete all as specified and as directed .
30Supply and fixing ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed ..
31Supply and fixing SMD LED highbay light 100 watts with innovatively designed alumnium heat shrink for excellent thermal management luminaire efficiency 150 Lm/W at any height, with suitable clamp, complete all as specified and direced.
32Supply and fixing in repair, LED Bldg Security Light Fittings of capacity 35 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including electronic driver and making electrical connection, complete all as specified and as directed . Cat part No.ENDCITYLIT PLAT + SL35WLED757SASYBOPCWOSPD of make Havells or equivalent in make given in Appx 'B'.
33Supply and fixing sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811826 of make Indo Asian or equivalent in make given in Appx 'B'.
34Supply and fixing MCB SP, 6-32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed.
35Supply and fixing MCB SPN 32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed .
36Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth lead of 4mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
37Supply and fix sheet metal enclosure Vertical triple pole & neutral(VTPN) IP-43 including MCCB 63 Amp, 16 KA, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed .
38Supply and laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed .Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
39Supply & laying as sub main wiring with four run of 10 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 10 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge.Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Five runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
40Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one Double pole MCB,.20 Amps, 10 KA 'B' curve including removing old unserviceable enclosure complete all as specified and as directed.
41Supply and fixing single pole and neutral enclosure with a five pin and earth plug and socket Triple pole and earth 63 Amp complete with and including one three pole MCB,.63 Amps, 10 KA 'C' curve including removing old unserviceable enclosure complete all as specified and as directed .
42Note:- Amount of credit of Rs.1,49,482.00 for retrieved materials is mentioned in Schedule of Credit Page No. 123 of tender doCubic metre ents in pdf form which will be deducted offline while acceptance of tender. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56108298
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20.08 Lakhs
LAST DATE 13-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair Of Bldg No. Ht-150 And Ht-151 (Rice Shed) Of Coy Asc (Sup) Type F Under Ge(N) Ambala Cantt
Basic Detail
Tender No GE(N)/AMB-18/2026-27
Bidding Type Tender
Location
City Ambala
State Haryana
Key Dates
Publish Date 22 Jun 2026
Submission Date 13 Jul 2026
Open Date 15 Jul 2026
Finance
Tender Value 20.08 Lakhs
Tender Fee 500
EMD 40160
Exemption Available
Document List
acd996cc-d2c2-4986-be13-760c0f5c466f.html
BOQ_866658.xls
Tenderdocument.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Jul 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

acd996cc-d2c2-4986-be13-760c0f5c466f.html

xls

BOQ_866658.xls

pdf

Tenderdocument.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders