Defence Statutory Bodies & Commissions/Committees Closing in 2 days TDR #56108294

Tender For Special Repair Of Bldg No. Ht-03 (Necessary Group) Of Coy Asc Type F Under Ge(N) Ambala Cantt

Issued by Statutory Bodies & Commissions/Committees · Ambala, Haryana
Tender Value
37.38 Lakhs
Estimated cost
Bid Submission
15 Jul 2026
2 days left
EMD
74760
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ambala → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair Of Bldg No. Ht-03 (Necessary Group) Of Coy Asc Type F Under Ge(N) Ambala Cantt

BOQ

Name of Work:- Special repair of bldg No. HT-03 (Necessary Group) of Coy ASC Type F under GE(N) Ambala Cantt
Sl. No. Item Description
1Schedule 'A' Part-I (B/R itmes) Dismantling wrought iron or mild steel work of any description not otherwise provided for including gates , plates , fillets, grills, stiffener for securing chain link fencing including nuts, bolts, etc. complete, all as specified and as directed.
2Dismantling wooden scantling 40 sqcm and over in section in framed work in position complete all as specified and as directed
3Supply and fixing of steel tubular trusses including special shaped washer, etc. complete using ERW or induction butt welded tubes conforming to I S.1161-1979 grade St.-240 complete all as specified and as directed .
4Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment.complete all as specified and as directed .
5Material and labour preparation of steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engineer–in–Charge.
6Dismantling asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings complete all as specified and as directed .
7Supply and fixing Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick having zinc coating 150 grams per Sqm (Az 150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed .
8Supply and fixing Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa having zinc coating 150grams/Sqm (Az-150) as in roof ridge,valley gutter etc fixed with self tapping screws complete all as specified and as directed.
9Demolition of cement concrete (un–reinforced) in ground floors and pavings not exe 15 cm thickness (below or above ground level) complete all as specified and as directed.
10Material and labour 25 mm thick PCC 1:2:4, type B–0 as in sub base floor (using 12.50mm graded crushed stone aggregate), finished even & fair without using extra cement to receive floor topping, complete all as specified and as directed .
11Material and labour machine cut kota stone slab 18 to 22 mm thick (size each slab shall not less than 550mm x 550mm) in floor, set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 15 mm thick screed bed in Cement Mortar 1:4 complete all as specified and as directed .
12Material and labour machine cut kota stone slab 18 to 22 mm thick ( kota stone shall be cut from size not less than 550mm x 550mm) in skirting , set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 10 mm thick rendering in Cement Mortar 1:44 complete all as specified and as directed.
13Material & Labour providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (not exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed.
14Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed .
15Material and labour brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed.
16Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed .
17Material and labour rendering 15 mm thick on brick work or concrete wall surfaces in cement mortar 1:4 including mixing water proofing compound @ 2% by weight of cement or as per manufacturer's instruction and finished fair and even without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note:- WPC shall be measured & paid separately)
18Supply only water proofing compound complete all as specified and as directed .
19Material and labour preparation of newly plastered surfaces on walls and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre per 10 Sqm including 1 to 2 mm thick wall care putty white cement based in one or two coats to achieve smooth surfaces up to height of triple storey bldg, including necessary scaffolding etc complete all as specified and as directed .
20M&L for rendering 15mm thick in cement plaster (1:6) on any faces of brick work or concrete wall surfaces and finished even and smooth without using extra cement up to height of double storey bldg, including necessary scaffolding etc complete all as specified and as directed.
21Material and labour for preparation of new decorated brick/concrete, plastered / unplastered surfaces of wall and applying three coats of white lime wash on prepared surfaces of wall etc., up to height of double storey bldg, complete, all as specified and as directed .
22Taking down chowkats or frames with shutter area not exceeding 1.50 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed .
23Taking down chowkats or frames with shutter area exceeding 1.50 Square meter and not exceeding 4.00 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed.
24Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other frames/ chowkhat of size 50 x 75 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant complete all as specified and directed.
25Supply and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-in-Charge. (Note: stainless steel butt hinges and necessary SS screws shall be paid separately) complete all as specified and as directed.
26Material and labour PCC 1:3:6 type B-I using 20mm graded stone agg as in holdfasts bed blocks for etc, complete all as specified and as directed.
27Cutting holes in brick walls built in cement mortar exceeeding half brick thick and not exceeding one brick thick wall for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 (Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall)as required , ,complete all as specified and directed.
28Supply and fixing mild steel works in bands, straps, supports, stays, bolts, hooks, hold fasts etc, similar articles conforming to Fe-290.Gde-E-165, complete all as specified and as directed.
29Material and labour plain cement concrete 1:2:4 type B–1 (using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork for rough finished surfaces of concrete complete all as specified and as directed .
30Supply and fixing stainless steel butt hinges 100mm long medium weight complete all as specified and as directed.
31Supply and fixing 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed.
32Supply and fixing 150 mm long aluminium handle cast type anodised, complete, all as specified and as directed.
33Supply and fixing 300mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter complete all as specified and as directed.
34Supply and fixing double shutter steel window box type ERW hollow P section comprising of glazed and gauged skeleton shutter fabricated from following sections :–(a) ERW hollow P section frame of size 60 mm x25 mm made from 1.25 mm thick MS sheet (02 Nos i.e. 01 for glazed shutter and 01 for gauzed shutter). Both P section shall be welded with flat iron 25x03 mm thick all around of frame on both inner and outer faces.(b) Style and rails of window shutters shall be fabricated with ERW hollow P section of size 50 mm x25 mm made from 1.00 mm thick MS sheet and comprising of 02 Nos sash bars for glazed window leaf of T – section 20 x 03 mm thick and one No sash bar of 20 mm x 3 mm thick section for gauzed winodw leaf.(c) Vertical mullion shall be ERW hollow T –section of size 60 x 25 mm made from 1.25 mm thick MS sheet(d) The above steel window shall be deemed to include the following accessories/ fittings :i) Hold fast 150mm long mild steel flat iron 12x3 mm thick made to shape– 04 Nos per windowii) Handle of Z section 20mmx25mm, 100mm long – 01 No per leaf.iii) MS tower bolt stove enamelled 150mm long– 2 Nos per leaf.iv) Z section 20mmx25mm, 100mm long stopper – 01 No per leaf.(v) Cleat 55 mm long of solid square 15x20x.63mm square – 01 No per leafvi) Pintal hinges 12 x 75 mm – 2 Nos each leafvii) 10mm square Guard bar @ 10 cm c/c welded to frame.(viii) Two coat of Synthetic enamel paint over one coat of red oxide primer.(ix) 0.36mm nominal dia of stainless steel wire mesh and average width of aperture of 1.40mm fixed in gauzed skelton shutter of window with flat iron 15 x 03 mm with steel screws.(x) 3mm thick sheet glass, ordinary quality and with oil putty in square n. exc 0.5 sqm in each pane fixed in glass shutter of window.(xi) Fabrication and fixing arrangements as per specification including cutting holes and making good dismantled portion in PCC 1:2:4 type B–1 /cement plaster 1:4 as require and make finish good to the existing surface complete all as specified and directed.Notes : (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit.(ii) Unit rate quoted against this item shall also include the iron mongery, grill and other accessoriries as mentioned above.(iii) The window upto 1.00 metre width shall consists of two leaves both for gauzed shutter and glazed shutter and all the shutters are openable. The window more than 1.00 metre width shall have two openable leaves on both outer side for gauzed shutter and glazed shutter and middle leaf/shutter shall be fixed type.
35Material and labour sheet glass 3.00mm thick ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and as directed.
36Supply and fixing for galvanized mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed .
37Supply and fixing fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc.complete all as specified and as directed .
38Supply and fixing as in repair stainless steel curtain rod 25mm dia having wall thickness 1.00mm with and including stainless steel decorative brackets, two lotto for each rod length at both end etc fixed with stainless steel screws complete all as specified and as directed
39Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings.etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m.complete all as specified and as directed
40Supply and fixing 11 to 15mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n exc 30cm long complete all as specified and as directed.
41Dismantling kota stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in cement mortar.complete all as specified and as directed
42Material and labour for Mirror polishing on existing/ old marble/ Kota stone work where ever required to give high gloss finish, complete all as specified and as directed .
43Supply and fixing GI Metal Suspended ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, and as directed by Engineer-in-charge. GI Metal Ceiling laying perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
44Supply and fixing 5mm PVC hollow sheet (the thicknees of inner wall 0.7 to 1.00mm) panelling inclusive of solvent cement and fixing at site with U clip or PVC frame as per specifications and drawing complete all as specified including dismantling of existing paneling.,complete all as specified and as directed.
45Supply installation, testing and commissioning of new turbo ventilator of 600mm dia manufactured from high grade aluminum alloy sheet not less than 0.50mm thick, complete with stainless steel shaft, sealed maintenance free ball bearings, aluminum base plate/adopter suitable for fixing on sloping galvalume sheet roofing including cutting of existing roofing wherever required, providing weatherproof flashing, sealing washers, self drilling, self tapping galvanized fastener, application of approved weatherproof silicone sealant, making all joints completely watertight, fixing in position on galvalume sheet structure at all heights and pitches, including all labour tools, tackles, scaffolding/lifting arrangements, transportation, testing for smooth rotation and proper ventilation and handling over complete in all respects.,complete all as specified and as directed.
46Schedule 'A' Part-II (E/M itmes)Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc., complete all as specified and as directed .
47Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. for one light/fan/exhaust fan/bell point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
48Description all as per serial item No.47 here-in-before but for One 3 pin, 6 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed.
49Description all as per serial item No.47 here-in-before but for One 3 pin 6 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed.
50Description all as per serial item No.47 here-in-before but for one socket outlet 16 Amp with 2.50 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade, ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly, complete all as specified and as directed.Note : (i) Point wiring shall be done in a manner that not more than 02 socket point executed in one circuit.(ii) Each socket point will be measured and paid as per point.
51Description all as per srl item No 47 here-in-before but for one socket outlet 16 Amp with 4.00 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4.00 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly, complete all as specified and as directed .Note : (i) Point wiring shall be done in a manner that not more than 01 socket point executed in one circuit.(ii) Each socket point will be measured and paid as per point.
52Supply and fixing of modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts, complete all as specified and as directed .
53Supply and fixing of modular socket outlet multipin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed .
54Supply and fixing ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
55Supply and fixing in repair LED batten fitting 18-20 watt, 4 feet, aluminium housing with electronic driver cool/warm type industrial model complete, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge. Cat part No. LUMILINE+ BS20WLED865SPCSS of make Havells or equivalent in make given in Appx 'B'.
56Supply & fixing LED Bldg Security Light Fittings of capacity 35-45 watt made up of die cast Cast aluminium housing with balck epoxy powder coating with cover heat resistance glass safty input voltage range 170 to 270 volts, with IP-66 protection and other connected accessories including service bracket of MS pipe 25/32 mm bore of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting to MS pipe as required at site and making electrical connection complete all as specified and directed.
57Supply & fixing LED Flood lights, 100 watt, IP-66, aluminum die cast housing with unique lens system and toughened glass with gasket 240 volt, 50Hz, AC supply complete with all accessories internally pre wired including connecting with flexible copper conductor to connector of the light with necessary fixing arrangements, including disconnecting and taking down existing old unserviceable fitting, complete all as specified and as directed by the Engineer-in-Charge. Cat part No. LFSM-100-C-V3 of make Orient or equivalent in make given in Appx 'B'.
58Supply and fixing TPN, DB, 4 ways, double door. Including MCCB 63 Amps, four pole, Complete all as specified and directed. Note: Thimble/lugs of rating of MCB TPN should be used with wire for fixing in the MCB
59Supply and fixing sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811826 of make Indo Asian or equivalent in make given in Appx 'B'.
60Supply and fixing MCB SP, 6-32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed.
61Supply and fixing MCB SPN 32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed .
62S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'B' curve including removing old unserviceable enclosure complete all as specified and as directed.
63Supply and laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium grade ISI marked of adequate size for housing the wires, complete all as specified and as directed by the Engineer-in-Charge.Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
64Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth lead of 4mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
65Supply and laying in trenches service cable 16 Sqmm 4 core XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power 1100 Volts grade with stranded aluminium conductor omplete all as specified and directed
66Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc. and getting out for soft/loose soil, ,complete all as specified and as directed.
67Supply and lay in repair, GI tubes light grade with connected fittings laid in trenches/wall/ pole for protection to UG cables of size 32 mm dia., ,complete all as specified and as directed.
68Material and labour for cushioning for protection of cable using dry river sand, free from particles, ,complete all as specified and as directed.
69Material and labour for Protection to cable with one layer of new bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class ‘B’ bricks, ,complete all as specified and as directed.
70Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceedig 25cm for soft/loose soil, ,complete all as specified and as directed.
71Removing excavated material not exceeding 50m and depositing where directed at a level not exceedig 1.5 m above the starting point, ,complete all as specified and as directed.
72Note:- Amount of credit of Rs.1,33,590.00 for retrieved materials is mentioned in Schedule of Credit Page No. 123 of tender doCubic metre ents in pdf form which will be deducted offline while acceptance of tender. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56108294
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 37.38 Lakhs
LAST DATE 15-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair Of Bldg No. Ht-03 (Necessary Group) Of Coy Asc Type F Under Ge(N) Ambala Cantt
Basic Detail
Tender No GE(N)/AMB-24/2026-27
Bidding Type Tender
Location
City Ambala
State Haryana
Key Dates
Publish Date 22 Jun 2026
Submission Date 15 Jul 2026
Open Date 17 Jul 2026
Finance
Tender Value 37.38 Lakhs
Tender Fee 500
EMD 74760
Exemption Available
Document List
519d67ec-93de-4d40-a53d-430cf7c37c3a.html
BOQ_866673.xls
Tenderdocument.pdf
Tendernotice_1 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Jul 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

519d67ec-93de-4d40-a53d-430cf7c37c3a.html

xls

BOQ_866673.xls

pdf

Tenderdocument.pdf

pdf

Tendernotice_1 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders