| 1 | S& F MS Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes;framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings, framework of water tanks and similar work conforming to Fe 290, Gde-E-165 for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts for ornametal and intricate design complete all as specified and directed. |
| 2 | S& F MS rolled sections as in main columns or cross beams, rafters, purlins etc.. of specified angular/ tubular sections, fixed with angle cleats or connecting plates confirming to Fe-410W (Gde E-250) quality B and upto height 10metre and including necessary scaffolding complete all as specified and directed. |
| 3 | S& F MS Frame work as in doors or gates of angle or other section with gusset plates,rails,braces,etc, complete, drilled for fixing of steel sheeting or other covering, Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (excluding of steel sheeting or other covering, running rails and guides) and hanging; also fastering and fixing confirming to Fe 410-W ,Gde-E-250 Quality A complete all as specified and as directed. |
| 4 | S& F MS Rolled sections fixed with angle cleats and connecting plates, etc as per direction by Engr-in-charge complete all as by Engr-in-charge complete Fe 410-W ,Gde-E-250 Quality A all as specified and directed. |
| 5 | S& F MS Mild steel screw bolts of 16mm dia with hexagonal or square heads at one end and screwed at another end each screwed end to be fitted with washers and one hexagonal or square length of bolt n exc 30cm long all as specified and directed. |
| 6 | M & L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel over a coat of red oxide zinc chrome primer Complete all as specified |
| 7 | Surface excavation not exceeding 30cm deep and averaging 15 cm deep and getting out of in soft/loose soil complete all as specified and directed by Engineer-in-Charge. |
| 8 | M&L for 100mm thick Cement concrete type B-1,1:2:4 (20mm graded aggregate) as in flooring and finished the surface without using extra cement complete all as specified and as directed |
| 9 | Material and labour for plain cement concrete (1:2:4) type B-2 using 40 mm graded stone aggregate as foundation filling and mass concrete in drain, complete all as specified and as directed. |
| 10 | M&L 100 mm thick plain cement concrete Type D2 1:4:8 (using 40 mm grtaded stone aggregate) as in sub floors all as spcifed and as directed. |
| 11 | M & L 15mm thick rendering on fair faces of brick work or concrete surface in cm 1:6 to be finished fair & even without using extra cement |
| 12 | M&L for Preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer |
| 13 | M&L Hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge. |
| 14 | M&L 75 mm thick for PCC 1:2:4, type B2 (using 40mm graded stone aggregate) for subbase in floor and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 15 | M&L sand filling 50 mm thick under floors or in foundation including watering and consolidation complete all as specified and directed by Engineer-in-Charge. |
| 16 | M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and directed by Engineer-in-Charge. |
| 17 | M&L PCC 1:2:4, Type B-1, (using 20mm graded stone aggregate) as in kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer-in-Charge. |
| 18 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point. |
| 19 | Supply and fix of Turin LED bollard light fitting 10 W or nearest higher wattage,230v,IP 66 to ensure sustainable suitable for Surface mounting, with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable base freme to fix the light all as specified and as directed. make Havells cat part no TURINBLS10W LED830PSYMTOPC OR its equivalent in CG/ Philips/ Bajaj |
| 20 | Supply and fix in replacement of Con LED bollard light fitting 08 W or nearest higher wattage,230v,IP 66 to ensure sustainable suitable for Surface mounting, with integrated Le Nxe ED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable base freme to fix the light all as specified and as directed. make Havells cat part no PSYM830TOPC OR its equivalent in CG/ Philips/ Bajaj |
| 21 | Supply and fixing in replacement of thermoplastic cable junction boxes IP 66 \\"halogen free and weather proof\\" for outdoor Installation with metric knockout for cable entry of size139 x119x70mm fixing on PCC block and glands suitable for 10 Sq mm 02 core cable all as specified and directed. Make : HENSEL Cat No K-9065.OR its equivalent in Sintex or any other approved make |
| 22 | Supply and laying/Clading with wall of LT UG XLPE insulated of size 10 Sq mm 4 core 1100 volt grade heavy duty cable multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel strip wire or tape and connecting up to the electrical system with suitable size of aluminium lugs complete all as specified and directed. |
| 23 | Excavation in trenches in Soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables/pole and getting out of excavated material complete all as specified and directed. |
| 24 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the pipes have been laid and tested complete all as specified and directed. |
| 25 | Supply and fixing High density poythelyne (HDPE) pipes of pressure rating 6kgf/ sq/ m of size 40 mm for cable protection laid in trenches complete all as specified and directed |
| 26 | Supply and fixing of feeder pillar box with 200 amp bus bar of having 63 amp MCCB as incoming fixed with angle iron of size 45x45 above the 45 cm ground level with PCC 1:3:6 all as specified and directed |
| 27 | Supply and fix 2 core 2.5 sqmm PVC insulated PVC sheathed weather proof multistranded Copper conductor cable 1100 volts grade drawn through in GI conduit, pole etc with MS clamps from junction box to street light fitting all as specified and directed. |
| 28 | Supply and fixing of PCC ring suitable for bollard light of dia 200 mm and 30 cm of height all as specified and directed |
| 29 | Supply and fix in replacement of Ruby LED post top 40W or nearest higher wattage,230v,IP 65 to environmental frindly ,long life aesthetically suitable for mounting, with integrated etcwith high power LED ,bright illumination . complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable base freme to fix the light all as specified and as directed. make Havells cat part no PSYM830PSYMTOPC OR its equivalent in CG/ Philips/ Bajaj Please Enable Macros to View BoQ information |