| 1 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in SOFT/LOOSE soil complete, all as specified and directed. |
| 2 | Excavation in trenches in SOFT/LOOSE soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for foundation, etc. and getting out complete all as specified and directed. |
| 3 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete all as specified and directed. |
| 4 | Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. |
| 5 | M&L for 15 mm thick plaster on fair faces of brick work or concrete surfaces, finished even and fair without using extra cement mixed with WPC in CM 1:4 complete all as specified and directed. Note:- WPC shall be measured and paid seperately. |
| 6 | M&L for new plastered surfaces of any description complete all as specified and directed and aplying the following :-(a) applying wall care putty in two coats on wall surfaces and smoothening the surfaces with sand paper / machinized sanding etc.(b) applying two coats of exterior acrylic emulsion paint over and including a coat of exterior primer complete all as specified and directed. |
| 7 | M&L for Plain Cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping,weathering, slightly rounded or chamfered angles and throating complete all as specified. |
| 8 | M&L for PCC type C-2 (1:3:6), using 40 mm graded crushed stone aggregates as in wall or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts , complete all as specified and directed. |
| 9 | M&L for Brick work using bricks as specified in PS, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified and directed. |
| 10 | M&L for Brick work using old size bricks (EXCEPT BRICKS) straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar (1:6), complete all as specified and directed. |
| 11 | S&F, Framed mild steel work such as grills, grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings, barred iron doors including side hung gates with pintel hinges, spop, hand made sliding bolts, framed work of water tanks, door chowkhats and similar work confirming to Fe-290-Gde E-165 quality A, complete all as specified and directed. |
| 12 | M&L for mild steel work as in rolled sections as in farming for cladding, glazing and the like fixed with angle cleats and connecting plates etc. quality conforming to grade Fe-290-Gde E-165 complete all as specified and directed. |
| 13 | M&L for Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members of weight not exceeding 4 kilogram/ sq. m, complete all as specified and directed. |
| 14 | S&F, Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of any colour hving tensile strength of 550 Mpa as in roof coverng/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 15 | S&F, Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm of any colour hving tensile strength of 550 Mpa as in roof coverng/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 16 | M&L for 100 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, finished even & rough, as in sub floors, complete all as specified and directed. |
| 17 | M&L for Endura/ Parking vitrifed paving coloured tles 18 to 20 mm thick (square/rectangular) area of each tile exc. 0.11 sqm but not exc. 0.18 sqm laid in floors etc, sent and jointed in neat cement slurry and pointed in grout of matching shade , laid and including 15 mm thick bedding layer in cement mortar (1:4) complete all as specified and directed. |
| 18 | M&L for 18-20 mm thick granite (of any type) work (table rubbed and polished) for wall lining (veeneering to wall) 15 mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite etc. complete all as specified and directed. |
| 19 | M&L for Providing and laying at or near ground level factory made kerb stone and drainage channel of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. complete all as specified and directed |
| 20 | M&L for 80 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 25mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 21 | M&L for 60 mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 25mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 22 | Fixing only cement concrete paver block as in footpath, parks, lawns, drive ways or light traffic parking etc including taking out paver block of any size fromsunk portion with and including requisite PCC 1:4:8 type D-2(40 mm graded aggregate) exceeding 50 mm thick but not exc 100 mm thick, including 25mm thick compacted bed of coarse sand, compacting complete all as specified and directed. |
| 23 | Supply only water proofing compound, ISI marked, complete all as specified. |
| 24 | S & F UV protected multi layered Polycarbonate sheet minimum 5 mm thick with complete fixing assembly , Polycarbonate sheet panel shall be minimum 4 layered and with grip lock notch standing seam running length way allow the connectors to be attached. The installation of panels with connectors guarantee a guard of water with 10-15 mm height . Panel shall be with additional end cap/aluminium U/F profile /Glazing bars for ends as required . Panel shall be fixed on purlins with continious twin wall aluminium spacers and HD polycarbonate U connector , complete all as specified and directed. |
| 25 | S&F Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections of grade Fe 410-W (Gde- E- 250) quality- A complete all as specified and directed. |
| 26 | M&L for Two coats of synthetic enamel paint over & including a coat of red oxide primer over steel or iron surfaces (new) of any description not other wise described over 10cm width or girth including preparation of surfaces, complete all as specified and directed. |
| 27 | Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 28 | Demolition of brickwork, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, complete all as specified and directed. |
| 29 | M&L for 600 mm bore RCC pipes class NP-2 (ISI marked) laid and jointed complete with collars, laid in trenches, and tested complete all as specified and directed. |
| 30 | M&L for 450 mm bore RCC pipes class NP-2 (ISI marked) laid and jointed complete with collars, laid in trenches, and tested complete all as specified and directed. |
| 31 | M&L for 300 mm bore RCC pipes class NP-2 (ISI marked) laid and jointed complete with collars, laid in trenches, and tested complete all as specified and directed. |
| 32 | M&L for providing and laying concrete bed in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in bed to drain pipes of 600 mm bore including packing under and haunching against the sides of the pipes completely after they are laid and tested complete all as specified and directed. |
| 33 | M&L for providing and laying concrete bed in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in bed to drain pipes of 450 mm bore including packing under and haunching against the sides of the pipes completely after they are laid and tested complete all as specified and directed. |
| 34 | M&L for providing and laying concrete bed in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in bed to drain pipes of 300 mm bore including packing under and haunching against the sides of the pipes completely after they are laid and tested complete all as specified and directed. |
| 35 | Demolition and breaking up of drain pipes (salt glazed ware or AC or reinforced cement concrete) set in cement mortar of 300mm dia complete all as specified and directed |
| 36 | Demolition and breaking up of drain pipes (salt glazed ware or AC or reinforced cement concrete) set in cement mortar of 450mm dia complete all as specified and directed |
| 37 | Demolition and breaking up of drain pipes (salt glazed ware or AC or reinforced cement concrete) set in cement mortar of 600mm dia complete all as specified and directed |
| 38 | S & F “RAJSHRI” Brand Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) JALI of required size comprising of virgin PVC resin of K Value 58-60 (Suspension Grade ), Calcium Carbonate and natural fibres ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm manufactured by \\"RAJSHRI\\" an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free. Water/ Moisture Proof and Fire Retardant. WPC Jali to be fixed with stainless Steel butt hinges ( if required ) of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For Interiors / Kitchen shutters / Balcony & Internal Doors and Partitions complete all as specified and directed. |
| 39 | Supply & Fixing \\"RAJSHRI\\" Brand factory made 100% Solid WPC ( Wood Polymer Composite ) - Door Frame 62mm x 32 mm Single Rebated, made from Wood Polymer Composite ( Single Extruded Process ) material comprising of virgin PVC polymer of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and Natural Fibres ( Wood Powder/ Rice Husk/ Wheat Husk ) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/ cum & manufactured by \\"RAJSHRI\\" an ISO 9001 - 2015 Certified Company, having good screw holding capacity resistance to spread of flame of class A category with property of being termite / borer proof , water / Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of required dia and length, all as per specifications drawings as directed by the Engineer-In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company ( Hold Fast or Dash Fasteners shall be paid separately ) - For WC/Bathroom/ Toilet etc, complete all as specified and directed. |
| 40 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any moratar complete all as specified and directed. |
| 41 | Dismantling expanded metal, any thickness or mesh , Weight per sq m not exc 4.00 kg, fixed with steel or wood fillets, if any complete all as specified and directed . |
| 42 | Dismantling of wrought iron of mild steel work of any description in any position not otherwise specifically provided for all as specified. |
| 43 | Dismantling timber scantlings Framed work in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed . |
| 44 | Dismantling Trellis work (Jafri), including taking as under of battens in trellis (posts and rails measured separately) complete all as specified and directed. |
| 45 | Demolition of cement concrete of any description and in any position not otherwise specficially provided for complete all as specified and directed |
| 46 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed |
| 47 | Notes: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline. Please Enable Macros to View BoQ information |