| 1 | Rewiring (Labour and Mtrl) for light point/Fan Point/Exhaust point with 1.5 Sq,mm FRLS PVC insulated Cable copper conductor single core cable and 1.5 sq .mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface /recessed steel / PVC conduit including dismantintling/removing of burnt cable from the existing conduit and making good to surface as required . |
| 2 | Rewiring (Labour and Mtrl) for Twin control Light point with 1.5 Sq,mm FRLS PVC insulated Cable copper conductor single core cable and 1.5 sq .mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/ PVC conduit including dismantintling/Removing of burnt cable as required . |
| 3 | Rewiring (Labour and Mtrl) for circuit /Submain wiring along earth wire with the sizes 2x2.5 Sq. mm + 1x2.5 Sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface /recessed conduit including dismantintling/Removing of burnt cable as required (For Power Plug) . |
| 4 | Point wiring in repair for light point/fan point/exhaust fan point /call bell with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate and cover with GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.including dismantintling/removing of burnt cable/including accessories and making good surface as per site required . |
| 5 | Point wiring in repair for 5 Amp socket outlet point for Independent board with 2x 1.5 sq mm single core PVC insulated and unsheathed FRLS cable, 1100 volts grade IS -694 marked with multistrandard copper conductors and earth continuity wire with similar 1x1.5 sq mm cable (incl connecting to earth dolly) drawn through and single core cable in surface/recessed medium class PVC conduit as required at site complete all as specified and directed. |
| 6 | Supply and fixing in repair suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular switch and 5/6A modular socket ,connection etc. as required at site complete all as specified and directed . |
| 7 | All as per item no 6 above but wiring for circuit alongwith 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit as required .wire 2x2.5 sq.mm + 1x2.5 sq.mm earth wire for 15/25 power plug/socket. |
| 8 | Supply and fixing in repair suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 15/16 A modular switch and 15/16A modular socket ,connection etc. as required at site complete all as specified and directed.(for 15/25 Power plug) |
| 9 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 10 | Supply & fixing in repair piano type 5/6 amps switch on the existing Switch box including connection as required on site. |
| 11 | Supply & fixing in repair piano type 2 way 5/6 amps switch on the existing Switch box including connection as required on site. |
| 12 | Supply & fixing in repair piano type 15/16 amps switch on the existing Switch box including connection as required on site. |
| 13 | Supply & fixing in repair piano type 3 pin 5/6 amps socket outlet switch on the existing Switch box including connection as required on site. |
| 14 | Supply & fixing in repair piano type 6 pin 15/16 amps socket outlet switch on the existing Switch box including connection as required on site. |
| 15 | Supply & fixing in repair piano type Telephone socket on the existing Switch box including connection as required on site. |
| 16 | Supply & fixing in repair 5/6 A modular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. |
| 17 | Supply & fixing in repair 2 way 5/6 A modular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. |
| 18 | Supply & fixing in repair 15/25 A modular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. |
| 19 | Supply & fixing in repair 3 pin 5/6 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. |
| 20 | Supply & fixing in repair 6 pin 15/25 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. |
| 21 | Supply & fixing in repair modular telephone socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. |
| 22 | Supply & fixing in repair modular bell push on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. |
| 23 | Supply and fixing in repair 1or 2 module base & cover plate on existing modular metal boxes etc as required. |
| 24 | Supply and fixing in repair 3 module base & cover plate on existing modular metal boxes etc as required. |
| 25 | Supply and fixing in repair 4 module base & cover plate on existing modular metal boxes etc as required. |
| 26 | Supply and fixing in repair 6 module base & cover plate on existing modular metal boxes etc as required. |
| 27 | Supply and fixing in repair 8 module base & cover plate on existing modular metal boxes etc as required. |
| 28 | Supply and fixing in repair 12 module base & cover plate on existing modular metal boxes etc as required. |
| 29 | Supply and fixing in repair of metal box of size 150mm/75mm/60mm deep (normal size) on surface or in recess with suitable size of modular plates /phenolic laminated sheet cover in front including providing and fixing 3/6 pin 5/6 A Socket outlet 5/6 A switch piano/modular type switch,connections,painting etc. as required |
| 30 | Supply and fixing in repair of metal box of size 180mm/100mm/60mm deep (normal size) on surface or in recess with suitable size of modular plates /phenolic laminated sheet cover in front including providing and fixing 6 pin 15/16 A Socket outlet 15/16 A switch piano/modular type switch,connections,painting etc. as required |
| 31 | Supply and fixing in repair PVC batten /angle holder including connections etc as required. |
| 32 | Supply and fixing in repair call bell ding dong suitable for single phase,230V V, complete as required. |
| 33 | Supply and fixing in repair of electronic industrial gong bell type size upto 10 inch wired door chime , 220v Ac , steel body ,wall hanging, suitable for office complete as required. |
| 34 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 35 | M & L in repair for PVC surface mounted Size upto 8 inch Dummy plates/Plastic modular fan plates /PVC electrical round sheets for covering junction box complete including making good to surface as per site requirement. |
| 36 | Supply and fixing in repair of 25 mm medium class PVC conduit along with acessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 37 | Supply and fixing in repair LED light fitting 1X20W,220V high efficiency (efficiency upto 100lm/w) polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution. |
| 38 | Supply and fixing in repair LED light fitting 1X10W,220V high efficiency (efficiency upto 100lm/w) polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution. |
| 39 | Supply and fixing in repair of LED 12w/10w LED Downlighter surface /recess type having high performance low height back lit downlighter suited for any modern professional workspace .Robodust PDC aluminium housing ensures long life. Available in 3000K,4000K,and 5700K CCT. Efficiency :100lm/W. |
| 40 | S & F in repair LED 20W T8 Tube with inbuilt driver and efficiency of 100lm/w having glare free lighting distribution, double sided connection, housing made of high grade polycarbonate cover,2.5 Kv internal surge protection,IP20 ingress protection,Pcb mounted on extruded metal plate. |
| 41 | Supply and fixing in repair of Compact industrial LED box type fitting 1X20W,220V having housing made of CRCA pre coated sheet steel suitable for office having single polycarbonate aluminum and glass tube. |
| 42 | Supply and fix in repairs of Compact industrial batten LED box type fitting 2x20W,220V having housing made of CRCA pre coated sheet steel suitable for office having twin polycarbonate aluminum and glass tube. |
| 43 | S&F in repair Building security light fitting LED 45 W, made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistance of IK07 with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to suitable shape out of GI pipe 40 mm bore light grade, 1.5 mtr length and fixed with MS Clamps of size 40x5 mm- 02 nos ,nuts, bolts and washers on wall. complete all as specified and directed. |
| 44 | Supply and fixing in repair of 9 watt LED lamp on the existing holder . |
| 45 | Supply and fixing in repair 4 way,(4+12), Double door surface/recess mounting, vertical type ,415 V,TPN, MCB distribution board of sheet steel, dust protected, duly powder painted ,inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs as required. |
| 46 | Supply and fixing in repair 4 way, Double door single pole and neutral sheet steel,MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) |
| 47 | Supply and fixing in repair 6 way, Double door single pole and neutral sheet steel,MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) |
| 48 | Supply and fixing in repair 8 way, Double door single pole and neutral sheet steel,MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) |
| 49 | Supply and fixing in repair 12 way, Double door single pole and neutral sheet steel,MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required. |
| 50 | Supply and fixing in repair 4 way,(4+12) double door horizontal type , Three pole and neutral sheet steel,MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required. |
| 51 | Supply and fixing in repair of 5A to 32 A rating,240/415V, 10kA \\"C\\" curve miniature circuit Breaker suitable for inductive load of single pole in the existing MCB DB Complete with connections, testing and commissioning etc as required. |
| 52 | Supply and fixing in repair of 5A to 32 A rating,240/415V, 10kA \\"C\\" curve miniature circuit Breaker suitable for inductive load of single pole and neutral in the existing MCB DB Complete with connections, testing and commissioning etc ax required. |
| 53 | Supply and fixing in repair of 63 A rating,240/415V, 10kA \\"C\\" curve miniature circuit Breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB Complete with connections, testing and commissioning etc as required. Make : IndoAsain/LT/Havells. |
| 54 | Supply and fix in repair MCCB 63 Amp,4 pole 415 volts,16 KA Complete all as specified and direted. |
| 55 | Supply and fix in repair MCCB 100 Amp,4 pole 415 volts,16 KA Complete all as specified and direted. |
| 56 | M&L in repair of existing industrial laminated sheet board/hylem sheet/phenolic laminated sheet 4/6 mm thick of any size for mounting switches, sockets, fan regulator, etc by punching required slots for switches/Sockets /Regulators as per site requirement including taking down the existing laminated top cover all as directed. |
| 57 | Supply and fixing in repair of casing and caping of size upto 50 mm including removing of old unserviceable one complete all as specified and as directed, |
| 58 | S&F in repair in repairs switch socket combination 5 Amp with PVC box suitable for 230 Volt. |
| 59 | S&F in repair in repairs switch socket combination 15 Amp with PVC box suitable for 230 Volt. |
| 60 | Wirirng in repair for circuit /Submain wiring along earth wire with the sizes 2x4 Sq. mm + 1x4 Sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface /recessed conduit including dismantintling/Removing of burnt cable as required . |
| 61 | Wirirng in repair for circuit /Submain wiring along earth wire with the sizes 2x 6 Sq. mm + 1x6 Sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface /recessed conduit including dismantintling/Removing of burnt cable as required . |
| 62 | Wirirng in repair for circuit /Submain wiring along earth wire with the sizes 4x 10 Sq. mm + 2x6 Sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface /recessed conduit including dismantintling/Removing of burnt cable as required . |
| 63 | Supply and fixing in repair 25 A,240V ,SPN Industrial type socket outlet with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve ,SP,MCB Protected Heavy Duty AC Box with 16A Plug for AC, Refrigerator, Geyser, Industrial Use and complete with connections, testing and commissioning etc.as required. |
| 64 | Supply and fixing in repair LED surface full fit luminaire 2 fit X2 fit (>100 Lumen/Watt) suitable for false ceiling ,white powder coated CRCA housing and high translucent frosted diffuser with glare free uniform illumination with longer life and less maintenance including all necessary electric connection. |
| 65 | Supply and fix in repairs of driver as per sample for indoor type LED fitting of following watt complete all as specified and as directed. |
| 66 | LED driver 10 Watt. |
| 67 | LED driver 18/20 Watt. |
| 68 | LED driver 36/40 Watt suitable for 2x2 false ceiling lights. |
| 69 | Dismantling and taking down ceiling fan any size for servicing by cleaning dust, filling cavities with filler and painting complete with synthetic enamel paint by spraying and re fixing the same in position, connecting and testing all as specified and directed. |
| 70 | M & L in repair for carry out rewinding of ceiling fan motor of any size/ make including taking down from any height , dismantling ceiling fan motor , removing old burnt winding wire, cleaning the armature thoroughly and replacing the same with new enameled copper wire of adequate size/gauge including class B insulation, varnishing heating etc, reassembling and removing the old painting and providing new painting to ceiling fans complete with synthetic enamel Grey paint by spraying using machine including filling cavities with filler one coat after cleaning all dust making the surface in good finishes etc , testing, refixing the same in original position complete all as specified and as directed by the Engineer-in-Charge. Note: Rate include the taking down the ceiling fan and deposited to MES store for checking and repairing) |
| 71 | All as per Item No.67 above but for the Exhaust fan of 300 /450 mm sweep sizes: |
| 72 | Materials and labour for repairing of the earthing complete with digging and filling the salt and charcoal 5-10kg and refiling sand including chamber plaster, providing the RCC cover of the required size including all neccessary work as per direction complete all as specified & directed |
| 73 | M&L in repair Earthing complete with galvanized steel earth plate electrode 600x600x6.0mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron strip 25 X 4mm as earthing by means of bolts nuts and washers of galvanized iron including excavation and earth work and disposal of surplus soil including 40 mm GI tubing light grade and necessary fittings for protection of GI strip including laying of charcoal , dust and common salt, PCC 1:2: 4 type B 1 using 20 mm graded aggregate with earth pit with 40 X 40 X 6.0 mm MS angle iron frame RCC cover 40 mm thick (1:2: 4) Type C0 (using 12.50 mm graded stone aggregate) reinforced with 8 mm dia round bar @ 75 mm C/C both way with plastering 15 mm thick CM ( 1: 6) internally and up to 150 mm below ground level externally, PGI funnel with wire mesh, 20 mm dia medium grade GI pipe for watering complete all as shown on electrical plate No : 03 of SSR part - I 2009 and connected to earth test point including testing and taking out old earthing complete all specified and directed. Note: No JCB excavation permitted. Please Enable Macros to View BoQ information |