| 1 | Pump and Others |
| 2 | Installation of Submersible Pump (0.5 HP) Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET, Single Phase with steel cable rope and submersible cable complete as directed and specified by the deptt. Single phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 0.5 HP STAGE 3 to 10 with control panel. |
| 3 | Installation of Centrifugal Pumpset (1 HP) Supplying, installation, fitting & fixing, testing and commissioning of Electric driven Single phase (for 1 HP pump) Centrifugal pump set of approved make with bronze impeller of suitable diameter with G.I. suction pipe, suction strainer, non-return valve, delivery piping up to sluice valve all complete. The pump set should be coupled with electric motor drive of adequate power suitable for operation at 230V / 415 V, 50 Hz input power with DOL Starter /Star delta Starter including Electric Control panel board enclosure made of MS Sheet duly painted with Anti- corrosive paints complete, fitted with all electrical accessories i.e. Off-On Switch, Voltmeter, Ammeter, Indicator light etc., Complete wiring from Panel Board to Main Line including supply of Aluminium Armoured Cable of adequate cross section, Earthing wire and all necessary materials for the same, including cost of CC pump foundation with base plate complete and other accessories and labour charge for installation of the pump etc. all complete as specified and directed by the Deptt. Recommended make:- Crompton Greaves/ Aquatic/ CRI/ GEC/ ALSTHOM/ V- Guard or equivalent |
| 4 | Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes (I) 1000 Lt capacity (a) Sintex make |
| 5 | Treatment Plant |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m2.8.1 All kinds of soil |
| 7 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:2.1.1 All kinds of soil |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. 10mm dia TMT(For footing, For Slab) 6-12 mm dia TMT(For Beam,For Column) |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. 8mm dia (Stirrup for Column ,Beam) |
| 11 | Centering and shuttering including strutting, propping etc. and removal i) footings ii)Columns |
| 12 | Centering and shuttering including strutting, propping etc. and removal i) Beam |
| 13 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : i)Footing ii) Post iii) Beam |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) derived from natural sources : 3 graded stone aggregate20 mm nominal size derived from natural sources). 1)Horizontal Slab 2)Vertical Slab |
| 15 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.For (i) Column (ii)BeamHorizontal Slab (iii) Vertical Slab |
| 16 | shallow well |
| 17 | Labour charge for making bore hole of 100 mm dia and collecting sample of soil at every 3.0 m depth or wherever there is a change of strata in sample boxes with the distinguishing marks including arranging and carriage of necessary boring materials / tools etc. and withdrawing the pipe for lowering well assembly etc. all complete as directed. |
| 18 | Labour charge for sinking, lowering, fitting, fixing in position of 100 mm dia U.P.V.C. pipe assembly comprising of strainer, pipes and cone in potable water bearing strata, washing the bore well etc. and supplying necessary jointing materials including carriage of materials and cleaning and priming the tube well all complete as directed. |
| 19 | Labour charge for packing coarse sand around strainer and casing pipe including supplying and carriage of materials all complete as directed and specified. |
| 20 | Labour charge for extraction against skin friction of 100 mm dia U.P.V.C./H.D.P. pipe assembly comprising of strainer, pipes and cone / plug (excluding the cost of side boring if necessary) clearing the site and if the bore hole make abandon then the bore hole to be sealed with bentonite clay including carriage of materials all complete as directed. |
| 21 | Construction of drain with cement concrete works in proportion 1:2:4 in slope 1:50 with a base layer of concrete of proportion 1:4:8 as per respective approved drawings including necessary earth work and refilling after completion of work all complete as directed. |
| 22 | 100 mm dia GI Nipple (100 mm length) |
| 23 | 100 mm dia UPVC casing pipe |
| 24 | 100 mm dia UPVC ribbed screen pipe |
| 25 | Filter Media |
| 26 | Supplying and placing of filter sand of hard andresistant quartz, uniform size and shape free fromdust, clay, soft grains, dirt and any other foreignmaterials includind inorganic salt and organicsubstance, washed and screened. Havinguniformity coefficient between 1.3 to 1.7, effectivesize between 0.45 to 0.70mm, ignition loss notexceeding 0.7% by weight, soluble fraction inHydrochloric acid not exceeding by 5% by weight,silica content not less than 90%, specific gravitybetween 2.55 to 2.65, wearing loss less than 3% asper IS: 1419 (Part-I):1977 all complete as directed |
| 27 | Supplying and placing of filter gravel of uniformsize and shape without flaxy shape free from dust ,clay, soft grains, dirt and other foreign materials,washed and screened to different sizes as givenbelow as per IS 8419 (Part-I) : 1977 all completeas directed.(a) Size from 2 mm to 6 mm |
| 28 | Supply, installation, testing and commissioning of storage type drinking water cooler of 30 litre/hour cooling capacity and 60 litre storage capacity, made of stainless steel tank and steel sheet body, complete with 2 nos. faucets, suitable for operation on 230V, single phase AC supply, having maximum power consumption of 400W, including all necessary fittings, accessories, connection to water supply and drainage, and making the system fully functional as per site requirement. Make: Blue Star or equivalent approved brand |
| 29 | SIGN BOARD |
| 30 | Supplying, fitting, fixing in position Multimedia pressure filter consisting of FRP vessel of Gratisco / TATA make filled with Anthracite, Kotax light media, White Sand, Treated Sand, Gravel, MnO2 filter media along with Cotton Candle to remove iron effectively at a max. pressure of 10 kg/sqcm and max flow rate of 1000 lph with back wash facility including all fittings, valves, Tee, Elbow etc. complete in all respect as directed including all Taxes. |
| 31 | Steel Staging |
| 32 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(A) Upto a depth of 2.00 m below the existing G.L. |
| 33 | Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. Brick on edge soling |
| 34 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a). In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine) |
| 35 | Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) M20 grade concrete |
| 36 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. Using 38mm thick plank |
| 37 | Supplying fitting and fixing M.S.angles, M.S. flat, M.S. bolts and nuts including painting with red lead paint one coat complete as directed. a) M. S. Angles……. |
| 38 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). a) From primary producer : TATA/ SAIL/ Jindal steel/ Shyam steel/RINL (i) TMT corrosion resistant steel (CRS) |
| 39 | Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe. (A) Exposed or in trenches25 mm nominal outer dia pipe a) Inlet Pipe b) Overflow & Backwash pipe Pipe |
| 40 | Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe. (A) Exposed or in trenches25 mm nominal outer dia pipe b) Overflow & Backwash pipe Pipe |
| 41 | 25 mm dia UPVC Elbow |
| 42 | 25 mm dia UPVC Bend |
| 43 | 25 mm dia UPVC Socket |
| 44 | 25 mm Bronze Ball valve (Screwed) (Zoloto or Equivalent) Please Enable Macros to View BoQ information |