| 1 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil. |
| 2 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, leadupto50 meter and lift upto 1.5m, as directed by Engineer-in-Charge. All kinds of soil : |
| 3 | Filling of good earth including diging, loading, unloading, royality, carriage & spreading in proper lines and grades and consolidation with power road roller complete. |
| 4 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level using 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 8 | Reinforcement for RCC work including straightening cutting,bending,placing in position & binding complete. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form work for: Suspended floors, roofs, landings, balconies and access platforms. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form work for Edges of slabs and breaks in floors and walls above 20 cm wide |
| 13 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 14 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacture, over the plastered wall surface to prepare the surface even and smooth complete. |
| 15 | Finishing walls with premium Acrylic smooth exterior paint with silicon additives of required shade: Old work (Two or more coats applied @ 1.43 liters/ 10 sqm) over existing cement paint surface. |
| 16 | Stone tile work for wall lining upto 10m height with special adhesive like araldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade Granite stone of any colour and shade |
| 17 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 18 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work |
| 19 | Providing and fixing aluminium work for doors, windows,ventilators and partitions with extruded built up standard tubular sections/appropriate Z. sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber Ineoprene gasket felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing /panelling, C.P.brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- Charge (glazing, panelling and dash fasteners to be paid for separately.) Anodised aluminium (anodised transparent or Dyed to required shade according to IS: 1868, minimum anodic coating of grade AC 15) |
| 20 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)Powder coated aluminum (minimum thickness of powder 50 microns) |
| 21 | Providing and fixing 4 mm thick ACP Sheet in panelling fixed in aluminum doors, windows shutters and partition frames (aluminum/ woodedn) with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharg |
| 22 | Providing and fixing glazing in alluminium doors, windows and ventilatior shutter and fixed partition with rubber and gasket,etc complete as per the direction of engineer in charge . With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm) |
| 23 | Providing and fixing Aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colours or shade with necessary screws etc complete job. 200x10mm |
| 24 | Providing and fixing Aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colours or shade with necessary screws etc complete job. 150x10mm |
| 25 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colours and shade with necessary screws etc complete including all leads, lifts and carriages complete. 125 mm |
| 26 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS :1868) transparent or dyed to required colours and shade with necessary screws etc complete including all leads, lifts and carriages complete. 100mm |
| 27 | Providing and fixing on wall face unplasticised -Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring comforming to IS : 5382 leaving 10mm gap for the thermal expansion complete job. Single Socket Pipes. 75 mm diameter |
| 28 | Providing and fixing on wall face unplasticised -Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring comforming to IS : 5382 leaving 10mm gap for the thermal expansion complete job. Single Socket Pipes. 110 mm diameter |
| 29 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion 110 mm Bend 87.5° |
| 30 | Providing and placing on terrace (at all floor levels) Polythylene water stoarge tank ISI 12701 marked indicating the BIS license No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license. |
| 31 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) Medium 15mm nominal bore |
| 32 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) Medium 25 mm nominal bore |
| 33 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete 25 to 40 mm nominal bore |
| 34 | Providing and fixing PTMT grating of approved quality and colour 100 mm nominal dia. |
| 35 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Semi rigid pipe 40 mm dia |
| 36 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 37 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 893115 mm nominal bore |
| 38 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 893 |
| 39 | providing and fixing uplasticized PVC connection pipe with brass unionS 5 cm length 15 mm nominal bor |
| 40 | providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete |
| 41 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 42 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 38mm of 83 mm length and 77 mm breadth weighing not less than 60gms |
| 43 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms |
| 44 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms |
| 45 | Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality Square shape 450mm internal dimensions |
| 46 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 20 mm nominal bore |
| 47 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 15 mm nominal bore |
| 48 | Manufacturing supplying and fixing retro reflective overhead signage boards made up of 2mm thick aluminum sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type-III of ASTM-D-4956-01 as approved by Engineer-in-charge; letters, borders etc. as per IRC : 67-2001 in silver white with blue colour background and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class -II of ASTM-D-4956- 01 and fixing the same to the plate of structural frame work by means of suitable sized aluminum alloys, rivets or bolts and nuts @ 300mm c/c all along the periphery as well as in two vertical rows along with theft resistant measures including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminum sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing nd erecting the same in position all complete as per drawing, specification and direction of Engineer-in-charge (Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). 16.67.1 Overhead informatory road signage |
| 49 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded |
| 50 | Applying priming coat: With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works |
| 51 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work |
| 52 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work. |
| 53 | Providing and installation of Vertical / Roller blinds complete in all aspects. |
| 54 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 55 | Extra for cutting reinforcement bars manually/by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional areas of R.C.C. or R.B. work) as per direction of Engineer-in-charge. |
| 56 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 57 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 58 | consolidation of sub grade with PRR of 8-10 tonne capacity |
| 59 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. In two layers |
| 60 | Dry brick pitching half brick thick including supply of bricks and preparing the surface complete. With common burnt clay (non modular) bricks of class designation 7.5 (in two Layers) |
| 61 | Providing and laying 75mm thick compacted bed of dry brick aggregate 40mm thick nominal size including spreading, well rammed, consolidated and grouted with fine sand including finishing smooth etc. complete as per direction of Engineer-in-charge |
| 62 | Supplying and Digging, carring by lorry,filling of black soil from Rajasthan as per lines cross sections, grade and camber including watering and consolidation in layers with 8-10 tonne power road roller complete (Finished work including material and labour) with carriages, lead, lifts loading and unloading complete. The work shall be got Executed in Presence of BCCI Certified Curator. |
| 63 | supply of Cricket Pitch Manual Roller -1.o Ton Capacity with Roller MS Sheet Thickness 15 to 18 mm Net Weight: 600 Kg, Gross Weight: 1000 Kg. (after filling with oil/water) with width of 3 feet and Extra small Iron Roller attached for better performance. |
| 64 | Supply & fixing of 40mm wide PVC strips for joints |
| 65 | 40mm thick marble chips flooring rubbed, under layer 28mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) and top layer 12mm thick with white, black, chocolate, grey, yellow or green marble chips of sizes from 7 mm to 10mm nominal size, laid in cement marble powder mix 3:1 (3 cement : 1 marble powder) by weight in proportion of 2:3 (2 cement marble powder mix :3 marble chips) by volume including cement slurry and curing complete : Ordinary cement without any pigment. |
| 66 | Centering and shuttering including strutting, propping etc. and removal of form work for: Edges of slabs and breaks in floors and walls under 20 cm wide |
| 67 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 68 | Providing and fixing of heavy duty net of thickness 2.5mm (mesh size 48x48 mm) to cover cricket prctice pitch on 3 sides & Top, as per direction of engineer in charge |
| 69 | Supply and installation of multipurpose turf for cricket ptactice net wickets with PE texturised monofilament Yarn with minimum pile height of 9 mm of european make only with 5 years warrenty |
| 70 | Carriage of sand from source to site of work including & unloading complete |
| 71 | Carriage of agg from source to site of work including & unloading complete |
| 72 | Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Group-A) |
| 73 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supply installation testing and commissioning of IP:20 Aluminium Batten 36 W LED Wall Mounted 1200 mm with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K, CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)Firm has to submit Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab with 05 years of warranty. |
| 74 | Installation, testing and commissioning of 200 mm sweep exhaust fan with robust motor, gravity shutters with speed rating of 1350 revolution per minute complete with all accessories etc. directly on ventilator , including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. Firm has to submit originallity certificate of material from OEM or Authorized Distributor with 05 years of warranty. |
| 75 | Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V, 1200 mm dia, Min. Air Delivery 212 CMM, Service Value 5.3 Cu.m/min/watt, Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. |
| 76 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 77 | Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required. (Copper winding) 1 hp |
| 78 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 79 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 80 | Supply and laying of PVC insulated and PVC sheathed / xlpe aluminium power cable of 1.1 KV grade of following sizes on surface / direct in ground including sand cushioning protective covering and refilling the trench as required as per direction of Engineer Incharge 25 sq. mm 3.5 core |
| 81 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door SPN MCBDB |
| 82 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral 32 Amp |
| 83 | Single pole and neutral 63 Amp |
| 84 | LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissi oning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85% Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, 54 DELHI SCHEDULE OF RATES (E&M)-2025EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 200 watt |
| 85 | Provision for supply and Installation of Pedestal with plate for Inauguration as per direction of Engineer Incharge Please Enable Macros to View BoQ information |