| 1 | Dismantling of asbestos cement sheet (corrugated or semi corrugated etc) as in roof covering complete all as specified and as directed. |
| 2 | Dismantling structural steel work including door and gates etc, complete all as specified and as directed. |
| 3 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa & minimum AZ @150 gm/Sqm( be coated with hot dip alloy of 55 % aluminium, 43.5% Zinc, 1.5% Silicon and finished with resin coat on both surface @ 150 gm/Sqm of coating both surfaces) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed. |
| 4 | Taking down carefully cement plaster on stone or brick wall surfaces, ceilings ,sunsheds, beams, chajjas, facia, roof projection etc upto cover depth by chipping out lightly including necessary scafolding & raking out joints , hacking for key & scrubbing down with water etc and removing of debris from site, complete all as specified and as directed. |
| 5 | M&L for 15 mm thick rendering in CM 1:6 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finished surface even and smooth without using extra cement etc, complete all as specified and as directed.Note -Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. |
| 6 | M&L for 15 mm thick rendering in CM 1:4 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finished surface even and smooth without using extra cement and including mixed with water proofing compound (WPC)as per manufactureres instructions, cplete all as specified and as directed.Note -(i) Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures.(ii) WPC shall be measured and paid seperately as \\"Supply only\\" in respective items. of BOQ. |
| 7 | M&L for 10mm thick rendering in cement mortar 1:4 on concrete ceiling surfaces / sunsheds / facia / RCC chajja, finished even and smooth without using extra cement, complete all as specified and directed.Note -Rate are deemed to be included for scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. |
| 8 | M&L for preparation of newly plastered or unplastered surfaces of ceiling and applying two coats of white wash on ceiling surface complete all as specified and directed. |
| 9 | Demolition of plain cement concrete(un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as directed. |
| 10 | Dismantling floor, hearth or wall glazed tiles/ kota stone/ terrazzo tiles any type including cement mortar bedding (but not backing) including removing broken tiles and removing the all rubbish off from the premises complete all as specified and directed. |
| 11 | M&L for 25mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in subbase of floor to receive tile finishes, complete all as specified & directed. |
| 12 | M&L for non-skid coloured ceramic tiles joint free 7 to 8 mm thick (Square/Rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 sqm ,as in floors etc., over & including 15mm thick screed bed in CM 1:4, set & jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed. |
| 13 | M&L for double charged light coloured Virified Ceramic tiles 9 mm to 10 mm thick, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match ,over & including 15 mm thick screed bed or bedding layers in CM (1:4) for laying in floors finishing ,complete all as specified and directed. |
| 14 | M&L for double charged light coloured Virified Ceramic tiles 9 mm to 10 mm thick, area of each tiles not exceeding 0.36 Sqm ,as in vertical surface such as dado/skirting etc ,set and jointed in neat cement slurry and pointed in colour cement to match the tiles,over & including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 15 | M & L glazed ceramic coloured tiles of size 300 mm x 450 mm x7mm thick/350 mm x 250 mm x7mm thick ,as in vertical surface such as dado/skirting etc ,set and jointed in neat cement slurry and pointed in colour cement to match the tiles,over & including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 16 | M&L for 18-20 mm thick machine cut Udaipur Green marble stone slab mirror polished as in steps, cills etc including rounding of edges at nosing, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, over & including 10 mm thick cement screed bed in CM 1:3 complete all as specified and directed. |
| 17 | M&L for 18 to 20 mm thick Black granite stone in single piece as in cooking plateform, slab for oval type WHB, sink / cills etc complete, laid over & including 15mm thick rendering layer in CM 1:3 and jointed with white cement with admixture of pigment to match shade of granite stone including grinding and polishing complete and providing necessary holes for gas pipe / water supply pipe etc. complete all as specified and directed. |
| 18 | M&L for preparation of new plastered or unplastered surfaces of wall and applying with 2.0 mm thick(minimum) wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper (shade or tint as approved by GE), over a coat of primer on walls surface complete all as specified and as directed |
| 19 | M&L for preparation of old decorated surfaces of wall including cornices, by brooming down or steel wire brushing to remove dust, dirt and loose scales and other foreign material, scrapping down, smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including filling the cracks and depressions with one layer of putty and applying two coats of oil bound distemper (shade or tint as approved by GE) on walls at any height applying by pump roller applicator of any shade or tint complete all as specified & directed. Please Enable Macros to View BoQ information |
| 20 | M&L for preparation of old decorated surfaces of wall including cornices, by brooming down or steel wire brushing to remove dust, dirt and loose scales and other foreign material, scrapping down, smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including filling the cracks and depressions with one layer of putty and applying two coats of oil bound distemper (shade or tint as approved by GE) on walls at any height applying by pump roller applicator of any shade or tint complete all as specified & directed. Please Enable Macros to View BoQ information |