Tender For Periodical Service To Md Accommodation In The Aor Of Age Br-I Under Ge Hisar At Hisar Mil Stn
Tender Value
40 Lakhs
Estimated cost
Bid Submission
10 Jul 2026
4 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hisar → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Periodical Service To Md Accommodation In The Aor Of Age Br-I Under Ge Hisar At Hisar Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement plaster or cement lime plaster on stone surface/brick surface of wall including racking out joints hacking for key scrubbing down with water etc. complete all as specified and directed by Engr-in-charge. |
| 2 | M&L for 10mm thick rendering in cement mortar (1:6) on fair faced or on other than fair face surface of brick masonary or concrete surface of wall, finished even & smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 3 | M&L for preparation of old/new plastered walls and applying avg 3mm wall care putty complete all as specified and directed. |
| 4 | M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over and including a coat of primer of same make complete all as specified and directed. |
| 5 | M&L for preparation of new surfaces (plastered or unplastered) of walls and applying two coat of white wash, complete all as specified & as directed. |
| 6 | M&L for rendering 5mm thick in CM 1:3 as in ceiling/landing etc on concrete surface finish even and smooth without using extra cement complete all as specified and directed. |
| 7 | M&L for preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash on undecorated surface complete all as specified and directed. |
| 8 | M&L for 15mm thick rendering in cement mortar (1:4) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge. |
| 9 | M&L for preparation of newly plastered surface of wall and applying two coats of external emulsion paint using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard techonology and capability of tracking pressure and paint usage as as per manufacturer instructions & technical data, accessories for applying external emulsion paint should be able to spray in hard to reach areas and penetration of external emulsion paint on the surface over and including one coat of acrylic waterbased exterior grade primer @ 0.8 ltr (undiluted)/ 10 sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of 01 ltr per minute having a pressure of 3300 PSI, (Allow 6-8 hrs to dry the surface for painting of before applying subsequent coats) over and including one coat of water proofing cement based putty @ 1 kg(undiluted) per sqm of average thickness 1mm over the plastered wall after prepare the surface even and smooth complete and sanding of the putty surfaces with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc, by skilled labour complete all as specified and directed by Engr-In-Charge. |
| 10 | M&L for complete removal of existing treatment and applying two coat of distemper oil emulsion over and including one coat of alkali resistance primer on wall surfaces complete all as specified and as directed. |
| 11 | M&L for preparing old surfaces and applying two coat of white wash on ceiling surface completel all as specified and directed. |
| 12 | M&L for preparation of old surfaces (plastered or unplastered) of walls including cornies, pilasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying two coat of white wash, complete all as specified & as directed. |
| 13 | M&L for complete removel of existing treatment of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including a priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L for preparing of old plastered or unplastered surfaces of walls and applying two coat of cement base paint on undecorated surface complete all as specified and directed. |
| 15 | M&L for preperation of old painted wooden or wood based surface of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamal paint complete all as specified and directed. |
| 16 | M&L for preparation of old painted steel surfaces & applying one coat of synthetic enamel paint on steel surface of any description over 10 cm in width or girth complete all as specified and as directed. |
| 17 | M&L for chipping of loose/ damaged /cracked / previously repaired / delaminated or weak concrete by chieseling to expose the sound core concrete where ever required and to expose rusted reinforcement upto depth n.exc 50mm and disposal of rubbish off the premises to a distance not exc 50 mtrs including cleaning of reinforced concrete surface by air compressor complete all as specified and directed. |
| 18 | Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using product: Rustoff-100 of Sika or equivalent make in Fosroc/ Thermax as approved by GE, with density 1.01 Kg/ltr at 30 degree celsius and consumption : 0.2 Kg/Sqm/coat complete all as specified and directed.Note : The mtrl to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar. |
| 19 | Supply and apply a cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and Product requirements: carbonation resistance: 2 mm of SikaTop Armatec®-108 of Sika or equivalent make in Fosroc / Thermax as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N / Sqmm according to ASTM C 882-78 complete all as specified and directed.Note: The mtrl to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar. |
| 20 | M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete surface in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions complete all as specified and directed. |
| 21 | M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc/Thermax as approved by GE at an average thickness of upto 10mm to the prepared concrete substrate in slffit of slabs, beam, columns, parapets, fins and facias at any height including finishing of applied Polymer mortar as per the technical specifications and manufacturer’s instructions complete all as specified and directed. |
| 22 | M&L for preparation of old surfaces of walls and applying one coat of distemper oil emulsion over and including a coat of alkali resistance primer on wall surfaces complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysJul 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender