Tender For Special Repair To Building No T-7 At Sahapore Mil C Under Ge (C) Kolkata
Tender Value
39 Lakhs
Estimated cost
Bid Submission
15 Jul 2026
7 days left
EMD
78016
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Building No T-7 At Sahapore Mil C Under Ge (C) Kolkata
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE ( C ) KOLKATA Name of Work:SPL REPAIR TO BLDG NO T-7 AT SAHAPORE MIL CAMP UNDER GE (C) KOLKATA Contract No: GE (C )/KOL/ /OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # ItemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), and removing rubbish off the Premises, complete all as specified and as directed. |
| 3 | Demolition of cement concrete (Un-reinforced) of any description and in any position not otherwise specifically provided for all as specified and directed. |
| 4 | Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed. |
| 5 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm and n.exc 4 Sqm each complete all as specified and directed. |
| 6 | Dismantling of GI (corrugated, semi corrugated, Plain) sheet in roof covering incl ridges complete all as specified and directed. |
| 7 | Dismantling AC Corrugated Sheets as in Roofing including Ridge or Similar Pattern Roof Coverings, complete all as specified and as directed. |
| 8 | Taking down roof trusses, coupled rafters or trussed beams Clear span above 4 meters & upto 8 meters. complete all as specified and directed. |
| 9 | Dismantling of Wall and Ceiling Board (Fibre, Pulp, Insulation etc.) or Insulation Board/Slab /Blankets, any thickness including Cover Fillets, complete all as specified and as directed. |
| 10 | Dismantling Timber Scantlings, 40 Sqcm and over in Section, in any Position, in Unframed Work, complete all as specified and as directed. |
| 11 | Taking down cement plaster of any description on brick work or stone msonary wall including racking ot joints hacking for key scrubbing down with water etc. complete all as specified and directed. |
| 12 | Excavation in trenches not exc. 1.5 Metre wide and not exc. 1.50 Metre in depth for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. or for cable protection not exc. 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 13 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 Cm as in soft/loose soil complete all as specified and directed. |
| 14 | Removing excavated material ( soils of any type) n exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 15 | M&L Brick work using Pulverizes fly ash bricks of class designation 75, straigth or curved on plan exc 6m mean radius built in CM (1:4) cmplete all as specified and directed. |
| 16 | Supply and fixing factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality including 4.8mm thick tinted glass complete all as specified and directed by Engineer-in-Charge. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 17 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi-chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality aand including stainless steel wire cloth 0.45 mm nominal dia of wire and average width of apperture 1.4mm and fixed with steel wire staples 4.8 mm thick sheet glass upto 1.5 mtr including necessary fitting and fixture, uPVC snap beading , complete all as specified and directed by Engineer-in-Charge.Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 18 | S&F Aluminium body(extruded section) door closer hydraulically regulated, designation No 2, universal type suitable for door shutters of 701 to 850 mm in width and weight between 36 to 60 kg and fixed as in repair complete all as specified and as directed. |
| 19 | S&F Fancy type, Powder coated 20/25 mm dia of drapery rod fixed in position as in repair complete all as specified and as directed |
| 20 | S&F Bracket for fixing Fancy type,Chromium Plated 20mm dia curtain rod/ drapery rod etc as in repair complete all as specified and as directed. |
| 21 | S&F MS Roof trusses (framed) , trussed , purlines, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or Flat section) including distance pieces , cleats etc Fe-410W (Gde E-250 Quality `A' complete all as specifed and directed. |
| 22 | M&L Mild steel Framed Work such as Grills, Gratings, etc. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed. |
| 23 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified and directed. |
| 24 | S&F Pre-painted colour galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 25 | M&L 4mm thick suspended false ceiling HPSC (high pressure steam curved) pre-primered fibre cement non asbestous building board similar to E-Board Classic placed in a grid of size 605x605mm with aluminium powder coated angle/channel/tee section duly suspended with 4mm dia GI hanger fixed with GI hooks 4mm dia and fastner as required at the site including two coat of oil bound distemper complete all as specified and directed. Detail of section are as under:-(i) Aluminium Angle 25mm x 25mm x 1.5mmt thick.(ii) Aluminium Cross Tee 25mm x 25mm x 1.5mmt thick.(iii) Aluminium Main Tee 25mm x 38mm x 1.5mmt thick.Note:-The bidder quoted rate included for all straight, Raking or circular cutting, wastage on ceiling board |
| 26 | M&L Cement Concrete type B0 (1:2:4) (12.5mm graded aggregate) 25mm thick, in Flooring, finishing concrete surfaces fair and even, complete all as specified and as directed. |
| 27 | M&L for 75mm thick PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) as in plinth protection laid in panels, finish the top surfaces even and smooth without using extra cement complete all as specified and directedNote:- Construction joints will be provided at interval of 2.5m length and filled with bitumen 80/20 mix with sand in ratio of 1:3 and cost of the same shall be deemed included in quoted rate |
| 28 | M&L Non-skid Ceramic Coloured Tiles, 7.0mm to 8.0mm thick (square/rectangular), area of each tile exc 0.18 sqm but not exc 0.38 sqm in Floors, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over 15mm thick screed bed (1:6) in cement mortar complete all as specified and as directed. |
| 29 | M&L Non-skid Ceramic Coloured Tiles, 7.0mm to 8.0mm thick (square/rectangular), area of each tile exc 0.18 sqm but not exc 0.38 sqm on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layer in cement mortar (1:4) complete all as specified and as directed. |
| 30 | M&L 20 mm thick rendering in cement mortar (1:4) on fair faces of brick or concrete external surfaces in two layers (each 10mm thick) finished even and smooth without using extra cement using water proofing compound on top layer @2% by weight of cement or as per manufactures instruction on external wall surface upto height of 4th storied bldg complete all as specified and directed.Note : WPC shall be measured and paid seperately |
| 31 | M&L rendering 15mm thick in CM (1:6) on other than fair faces of brick work or concrete surfaces even & fair without using extra cement complete all as specified and directed |
| 32 | \\"Supply only\\" liquid water proofing compound (ISI marked) complete all as specified and directed.Make:- STP NO 1/ PEDILITE(DR FIXIT)/ FOSROC/ CICO/ SIKA/Icannano |
| 33 | M&L Preparing new Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion over a coat of primer and applied over 1.5mm thick (appx) water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 34 | M&L Complete removal of existing Treatment of old decorated Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion over a coat of primer and applied over 1.5mm thick (appx) water proof wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed. |
| 35 | M&L preparing newly plastered surfaces and Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed. |
| 36 | M&L complete removal of old decorated surfaces and Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: Old work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed. |
| 37 | M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Red Oxide/ Zinc Chrome Primer, complete all as specified and as directed. |
| 38 | Taking down carefully existing unserviceable copper/aluminium point wiring (light, fan, socket or power point etc) complete with fittings/fixures such as switches sockets, ceiling rose, fan regulators, FTL fittings and making good to the disturbed surface complete all as directed by Eng-in-Charge. |
| 39 | M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium duty with all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps incl Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3, cutting not exceeding 10 cm girth in brick walls etc complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. |
| 40 | All as per item No. 38.00 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge. |
| 41 | All as per item No. 38.00 here-in-before but one 3pin switch socket outlet 5A on independent board complete all as specified and directed by engineer incharge. |
| 42 | All as per item No. 38.00 mentioned here-in-before but using 2.5 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board including 2.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly complete all as specified and directed by engineer incharge. |
| 43 | All as per item No. 38.00 mentioned here-in-before but using 4.0 sq mm size stranded copper conductor cable for one AC starter/Geyser point including 4.0 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly complete all as specified and directed by Engr-in-Charge. |
| 44 | S&F A C starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewire complete all as specified and directed by Engineer-in-Charge. |
| 45 | S&F Ceiling rose surface bakelite three terminals 240 volts complete all as specified and as directed. |
| 46 | Supply & fix Switch piano, flush type, SP, one way, 5/6 Amps 230/240 Volts, white/ivory finish complete all as specified and directed. |
| 47 | \\"Supply & fix Bell/buzzer push 5/6 amps, flush type, white/ivory finish complete all as specified and as directed. |
| 48 | Supply and fix Socket outlet 3/5 pin, 6 Amps, 240 volt flush type complete all as specified and as directed. |
| 49 | Supply and fix Switch socket combination multipurpose 2 in 1, 3 pin 6 Amps 230/240 volt flush type complete all as specified and as directed. |
| 50 | Supply and fix Switch socket combination multipurpose 2 in 1, 3 pin 5 & 15 Amps 230/240 volt flush type complete all as specified and as directed. |
| 51 | Supply and fixing ceiling Fan regulator step type 240 Volt complete all as specified and directed by the Engr-in-Charge. |
| 52 | \\"Supply and fix Call bell ding dong AC 230 volts, single pole complete all as specified and as directed. |
| 53 | S&F Energy efficient LED fittings of capacity 1 x 20W suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length complete all as specified and as directed. |
| 54 | S&F LED bulb 9 Watts 240Volts 50 hz with angular PVC/ Policarbonate bulb holder having luminous Efficacy of minimun 110 Lm/ Watts and life of atleast 15000 Hours ,opearting temperature of 0 C to 35 C , colour rendering index of 80 , colour temoerature of Min 6500K with start up time less than 2seconds, voltage withstand range of 140V- 270V complete all as specified and as directed. |
| 55 | Supply and fixing LED 2x2 ceiling light with superior efficacy of min 100lm/W, AC 120-300V, 50Hz CRI 80+ CCT 6500 35/36W to be fixed in ceiling and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length with all the connection as directed by Engr in Charge. |
| 56 | S&F building security light pressure die cast housing with individual LEDs with modular secondary optics security light luminaires 35 watt LED with 50mm dia light grade GI pipe bent to shape of 45'' 1.5 mtr long and nuts bolts including fixing arrangement after taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge. |
| 57 | Taking down unserviceable rusted / damaged MCB DBs of any type including MCBs and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed. |
| 58 | S&F Sheet metal enclosure for DB's when MCBs to be used 4 way single pole and neutral double door with 200 amps rated bus bar complete 240 volts complete all as specified and as directed. |
| 59 | S&F Sheet metal enclosure for DB's when MCBs to be used 8 way SPN double door with 200 amps rated bus bar complete 240 volts complete all as specified and as directed. |
| 60 | S&F Sheet metal enclosure for DB's when MCBs to be used 12 way SPN double door with 200 amps rated bus bar complete 240 volts complete all as specified and as directed. |
| 61 | S&F Sheet metal enclosure for DB's when MCBs to be used 4 way TPN double door with 200 amps rated bus bar complete 240 volts complete all as specified and as directed. |
| 62 | S&F MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve breaking capacity 10 kA complete all as specified and as directed. |
| 63 | S&F MCB 40 to 63 Amps, DP 240 Volts ,C- Curve breaking capacity 10 KA including necessary connection complete all as specified and as directed. |
| 64 | S&F MCB 40 to 63 Amps, TPN 240 Volts ,C- Curve breaking capacity 10 KA including necessary connection complete all as specified and as directed. |
| 65 | Taking down aluminimum sub mainwiring alongwith dameged casing capping /PVC conduit pipe from the wall roof or in floor and making good disturbuted surfaces complee all as directed |
| 66 | M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 6.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 25 mm dia including all fittings complete all as specified and as directed.Note:- Two runs of 6 Sqmm conductor as main wire and one run of 6 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. |
| 67 | Taking down and opening out the fan blade of exhaust/ceiling fan and keep it to safe custody for refixing after painting of ceiling fan/wall fan/exhaust fan of any size and sweep complete with synthetic enamel paint by spraying including filling with cavities with filler, after cleaning all dust etc andf refing to original/ new position after rewiring complete all as specified and directed by Engineer-in-charge. |
| 68 | M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 15 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and directed. |
| 69 | Taking out unserviceable UG cables of any type and any sizes from trenches etc and removing from the site of work complete all as specified and directed.Note:- (i) Serviceable bricks obtained shall be stacked properly for re-use. (ii) Excavation and earth work shall be measured and paid separately under relevant item of these schedule. |
| 70 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 50 Sqmm 4 core in trench/duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge. |
| 71 | Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge.Note:- Thickness after punning down shall be measured for payment. |
| 72 | Supply and laying double wall corrugated pipe (DWC) conforming to IS 19430 Part - I of size 80mm outer dia complete all as specified and as directed Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysJul 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender