Tender For Special Repair To It Section At Afac Coimbatore.
Tender Value
20.76 Lakhs
Estimated cost
Bid Submission
10 Jul 2026
2 days left
EMD
41600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To It Section At Afac Coimbatore.
BOQ
| Sl. No. | Item Description |
| 1 | Material & Labour for Excavating in post holes (or similar holes) in hard/dense soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,in any type of soil complete all as specified and directed. |
| 2 | Precast cement concrete block masonry with solid blocks Type C1, 1:3:6(20mm graded aggregate), exc.10cm in width and setting in mortar of 1:6, complete all as specified and directed. |
| 3 | Material & Labour for cement concrete Type B2, 1:2:4 (40mm graded aggregates) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases), complete all as specified and directed. |
| 4 | Taking down of chowkats with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each complete all as specified and directed. |
| 5 | Taking down of chowkats with shutters (without taking off shutters from the frames) exceeding 1.5 sqm and not exceeding 4 Sqm each complete all as specified and directed. |
| 6 | Providing and fixing factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm),Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories for area not exceeding 2.00 sqm each complete all as specified and directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) |
| 7 | Providing and fixing factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm),Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories for area exceeding 2.00 sqm each complete all as specified and directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) |
| 8 | Supply & Fixing PVC insulation panels of 10mm thick with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing complete all as specified and directed. |
| 9 | Taking down Repairs to shutters of any discription ex 2sqm each shutters and refixing in the same opening complete all as specified and directed. |
| 10 | Taking down Repairs to frames or chowkats exc 1.5 sqm but n exc 4 sqm each and refixing in the same opening complete all as specified and directed. |
| 11 | Supply & Fixing 1st class hardwood Plain,solid,straight chowkats and frames,wrought,framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints complete all as specified and directed. |
| 12 | Supply &Fixing in repairs Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each on 1st class hardwood complete all as specified and directed. |
| 13 | Supply & Fixing for Solid PVC Wall Lining consisting of 5mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications complete all as specified and directed. |
| 14 | Supply & Fixing for 5mm thick 5mm Prelam PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent,complete all as specified and directed. |
| 15 | Supply & Fixing for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification,complete all as specified and directed. |
| 16 | Supply & Fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples. |
| 17 | Supply &Fixing in repairs 140 mm floor door stopper of aluminum alloy body and tongue,anodised with hard drawn steel spring fixed in floor complete all as specified and directed. |
| 18 | Supply &Fixing in repairs 200 mm long aluminium anodised barrel tower bolt complete all as specified and directed. |
| 19 | Supply &Fixing in repairs150 mm long extruded aluminium anodised handle fabricated type complete all as specified and directed. |
| 20 | Supply &Fixing in repairs100mm size Butt hinges, heavy weight,cold rolled mildsteel complete all as specified and directed. |
| 21 | Supply &Fixing in repairs100 mm Aluminium 4 lever Mortice lock,vertical type complete all as specified and directed. |
| 22 | Supply & Fixing in repair Continuous (piano) hinges,brass 40mm width of flaps (when open) complete all as specified and directed. |
| 23 | Supply & Fixing in repair 100mm extruded brass handles, fabricated type polished complete all as specified and directed. |
| 24 | Supply & Fixing Ball catches/magnet catches with 8mm dia steel ball, and brass body and striking plate including letting in complete all as specified and directed. |
| 25 | Supply & Fixing 2Lever brass Locks, cupboard, grade I, size 50 mm complete all as specified and directed. |
| 26 | Supply & Fixing for plates Fe410-W(Gde E-250) quality A(plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes,with riveted, bolted or welded attachment complete all as specified and directed. |
| 27 | Supply & Fixing Fe410-W(Gde-E-250) quality-A, Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed. |
| 28 | Supply &Fixing Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 29 | Material & Labour for Anodised aluminium powder coated snap grid frame work of grid size 605x605mm supported by hanger 6mm dia G.I. (upto length as per site requirement) for false ceiling, adjusting level fixed to roof slabs/walls/wooden members by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60cm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specifiedfor false ceiling fixed with screws as per manufacturers instructionsin flat or slope ceiling complete all as specified and directed. |
| 30 | Supply & Fixing Powder coated aluminium(minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and all as specified and directed. |
| 31 | Supply & Fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge |
| 32 | M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed. |
| 33 | Material & Labour for 18/19mm Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and directed. |
| 34 | Material & Labour for Cement concrete type B-1,1:2:4 (20mm graded aggregate) 40mm thick for sub base of floors complete all as specified and directed. |
| 35 | Material & Labour for Light shade Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 36 | Dismantling wall floor hearth tiling including cement mortar bedding (but not backing) and removing unserviceable material complete all as specified and as directed. |
| 37 | Material & Labour for Coloured glazed ceramic tiles of size300x200x7mm / 450x300x7mm / 600 x 300 x 7 mm thick with rectified edges as in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and incl rendering of 10 mm thick backing with cm 1:4 complete all as specified and directed. |
| 38 | Material & Labour for Screed bed or bedding layer of mortor 15 mm thick in CM 1:4 for laying floor finishes all as specified and directed. |
| 39 | Material & Labour Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set jointed and pointed in neat cement slurry in floors with grey cement and red colour pigments complete all as specified and directed. |
| 40 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc.of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 41 | Material & Labour for Rendering 10mm thick on fair faces of brick work or concrete surfaces with cement plaster in CM 1:6 even & smooth with or without using extra cement complete all as specified and directed. |
| 42 | Material and labour Rendering 15 mm thick cement plaster in CM 1:4 for fair faces of brickwork or concrete surfaces wall finished even & smooth with or without using extra cement complete all as specified and directed. |
| 43 | Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed. |
| 44 | M & L for new surface of wall by washing including perpration of surface and priming plastered and other surfaces with alkali resistant priming paint and then applying 3mm layer of wall putty (JK or Birla) and applying two coat of oil bound distemper complete all as specified and directed. |
| 45 | Material & Labour for preparation of old treated surfaces of ceiling by complete removal of existing treatment and applying two coats of white wash on ceiling.surface all as specified. |
| 46 | Material & Labour for Complete removal of existing treatment on old surfaces of wall and Finishing walls with two coat of Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 47 | Material & Labour for Complete removal of existing treatment on old surfaces of wall and Distempering with 1st quality acrylic distemper(ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on one coat of primer over 1mm thick wall care putty on wall complete all as specified and directed. |
| 48 | Supply & Fixing of Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5sq.m in each pane having thickness 4mm complete all as specified and directed. |
| 49 | Supply & Fixing Sheet glass,ordinary quality and glazing with oil putty in square exc 0.5sq.m in each pane having thickness 4mm complete all as specified and directed. |
| 50 | Material & Labour for Painting and preperation of new wooden surfaces applying pink primer and two coats of synthetic enamel paint (ordinary tint) over 10cm width or girth all as specified and directed. |
| 51 | Material & Labour for Painting and preperation of old wooden surfaces applying pink primer and two coats of synthetic enamel paint (ordinary tint) over 10cm width or girth all as specified and directed. |
| 52 | Material & Labour for one coats of synthetic enemal paint on old steel surfaces including preparation of surface complete all as specified and directed. |
| 53 | Material & Labour for two coats of synthetic enemal paint over a coat of red oxide on new steel surfaces including preparation of surface complete all as specified for members not exceeding 10cm in width or girth when unconnected with other painting or when painted in a different tint complete all as specified and directed. |
| 54 | Demolition of (Unreinforcement) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 55 | Demolition of brickwork or stone/boulder masonary, build in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but complete all as specified and directed. |
| 56 | Demolition of RCC of any description and in any position not otherwise specifically provided for( reinforcement cut as required to facilitate demolition) |
| 57 | Separating, scraping and cleaning of reinforcement complete all as specified and directed. |
| 58 | Demolition of wall and ceiling boards (Fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets, frame work complete all as specified and directed. |
| 59 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. |
| 60 | Taking down old unserviceable point wiring (light, fan socket or power) complete, including fixture and fittings such as switches,ceiling rose, pendents, regulators,sockets, light fittings, energy meters etc.removing materials for keeping for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc complete all as specified and directed. |
| 61 | Taking down old unserviceable submain wiring of any size including GI/copper earth continuity conductor in PVC conduit on wall/roof and making good to disturbed complete all as specified and directed. |
| 62 | Disconnecting electric connection and taking down main switch/SPN DB/TPN DB of any size and keep in safe custody for taking credit complete and good/levelling the disturbed surfaces of wall to match with existing surface complete all as specified and directed. . |
| 63 | Taking down Ceiling fan sealing cable end, dismantling blades from fan and keeping in safe custody for reuse at site and making good disturbed surfaces complete all as specified and as directed. |
| 64 | Refixing only Ceiling fan with and including carrying out cleaning servicing, oiling and greasing of ceiling fans and connecting up including provision of cable from celling rose/ connector to fan all as specified and as directed. |
| 65 | M&L painting of Ceiling fan complete, in situ with synthetic enamal paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc all as specified and as directed. |
| 66 | Taking down exhaust fan, sealing cable end, dismantling blades from fan and keeping in safe custody for reuse at site and making good disturbed surfaces complete all as specified and as directed. |
| 67 | Refixing only exhaust fan ( In Repair) and connecting up including provision of cable from celling rose/ connector to fan complete all as specified and directed. |
| 68 | Material & Labour for concealed Point wiring with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC casing caping with all accessories such as internal bend, end caps etc complete in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc, for one light/bell point controlled by one, one way switch complete all as specified and as directed. |
| 69 | Material & Labour for concealed Point wiring with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC casing caping with all accessories such as internal bend, end caps etc complete in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc, for one ceiling/exhaust fan point controlled by one, one way switch, complete all as specified and as directed. |
| 70 | Material & Labour for concealed Point wiring with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC casing caping with all accessories such as internal bend, end caps etc complete in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc, for one 05 Amps socket outlet point on same board controlled by one, one way switch, complete all as specified and as directed. |
| 71 | Material & Labour for concealed Point wiring with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC casing caping with all accessories such as internal bend, end caps etc complete in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc, for one switch socket outlet point 5 Amps on independent board controlled by one, one way switch, complete all as specified and as directed. |
| 72 | Material & Labour for concealed Point wiring with 2.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC casing caping with all accessories such as internal bend, end caps etc complete in walls and surface in ceiling/roof/etc including 2.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc, for one Three Pin socket outlet outlet, 15 Amps as earth continuity conductor on independent Board complete all as specified and as directed. |
| 73 | Material & Labour for concealed Point wiring with 4 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC casing caping with all accessories such as internal bend, end caps etc complete in walls and surface in ceiling/roof/etc including 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc,for one switch socket outlet point 15 Amps on independent board controlled by one, one way switch complete all as specified and as directed. |
| 74 | Supply & Fixing for Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed. |
| 75 | Supply & Fixing for Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed. |
| 76 | Supply & Fixing for Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed. |
| 77 | Supply & Fixing socket Modular 6/16A 2/3 pin combined 2 module complete all as specified and as directed. |
| 78 | Supply & Fixing Modular fan regulator step type 120 W, 2 module complete all as specified and as directed. |
| 79 | Supply & Fixing Modular Modular Bell Push 6A 1 Module complete all as specified and as directed. |
| 80 | Supply and fixing LED lights fitting 1 x 18/ 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with white three core flexible copper conductor cable of suitable size from ceiling rose/connector complete all as specified and directed. |
| 81 | Supply and fixing LED lights fitting 600 mm x 600 mm 35/36 watts 220 Volts recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with driver holders and LED lamp suitable for roof/ceiling including connecting up with driver white three core flexible copper conductor of suitable size from celing rose/connector complete all as directed |
| 82 | Supply and fixing LED mirror light fitting with high output diffuser two feet 10 watts 230 volts AC decorative type with driver holder and LE lamp including connecting up with white hree core flexible copper conductor of suitable size from celing rose/connector complete all as specified and directed. |
| 83 | Supply & Fixing Call Bell Ding Dong AC 230 V single pole complete connecting up with flexible copperconductor cable of suitable size complete all as specified and directed. |
| 84 | Supply and laying PVC non metalic conduit including tees, bends, elbows, reducers, and fixing accessaries etc for telephone/Lan connection of size 25 mm dia including taking down Lan cable any type complete all as specified and directed. Note (i) Cutting chases will be Measured and paid seperately (ii) Telephone/Lan cable provide by user section . |
| 85 | Supply and fixing PVC non metalic junction boxes one to four way for telephone/TV connection of size 20 mm dia complete all as specified and directed. |
| 86 | Supply and fix modular telphone socket RJ 11 one module including taking down unserviceable socket complete all as specified and directed. |
| 87 | Supply and fix MCB DB, SPN, 8 ways, double door, 240 volt, Isolated neutral bar with IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete complete all as specified and directed. Make: L&T/Legrand/ Havells |
| 88 | Supply and fix MCB DB, SPN, 12 ways, double door, 240 volt, Isolated neutral bar with IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete complete all as specified and directed. Make: L&T/Legrand/ Havells |
| 89 | Supply and fix MCB DB, TPN, 4 ways, Double door, 415 volt, isolated neutral bar with IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete all as specified and directed. Make: L&T/Legrand/ Havells |
| 90 | Supply and fix MCB DB, vetical MCCB as a incommer TPN, 8 ways, Double door, 415 volt, isolated neutral bar with IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete all as specified and directed. Make: L&T/Legrand/ Havells |
| 91 | Supply and fix MCCB 415 volts 16 KA four pole suitable for vertical TPN of capacity 63 amps including taking down unserviceable MCCB complete all as specified and directed. |
| 92 | Supply and fix MCB SP 6 to 32 Amps, 240Volts, 10 KA, \\"B\\" Curve complete all as specified and directed. Make: L&T/Legrand/ Havells |
| 93 | Supply and fixing SPN 32 Amp rating 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) complete all as specified and directed. Make: L&T/Legrand/ Havells |
| 94 | Supply and fixing TPN/FP 40 to 63 Amp rating 415 V, 10 KA 'B' curve miniature circuit breaker (MCB) complete all as specified and directed. Make: L&T/Legrand/ Havells |
| 95 | Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals complete all as specified and directed. |
| 96 | Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc and cutting chases for concealed wiring,etc and making good, cutting not exc 10 cm girth complete all as specified and directed. |
| 97 | Material & Labour for concealed/surface Sub main wiring by making recess in wall/surface complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etc from Main DB to MCB DB all as specified and as directed by engr - in- charge. Note :- 2 runs of 6 sqmm, + 1 run of 6 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length. |
| 98 | Material & Labour for concealed/surface Sub main wiring by making recess in wall/surface complete with 2 runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etc from Main DB to MCB DB all as specified and as directed by engr - in- charge. Note :- 2 runs of 4 sqmm, + 1 run of 4 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length. |
| 99 | Material & Labour for concealed/surface Sub main wiring by making recess in wall/surface complete with 4 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etc from Main DB to MCB DB all as specified and as directed by engr - in- charge. Note :- 4 runs of 6 sqmm, + 1 run of 6 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length. |
| 100 | Material & Labour for earthing complete with GI earth plate electrode 600 x 600 x 6.3 mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI earth lead 4 mm wire by means of bolts, nuts, check nuts/bracing and washers all as shown in electrical plate No. 3 of SSR Part-I and including necessary excavation and earth work in any type of soil, removal and refilling of soil and funnel with wire mesh and GI watering pipe 20mm dia, Chamber in PCC 1:3:6, type C1 using 20mm graded stone aggregate and 40mm thick cover in RCC 1:2:4, type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 150mm c/c on both ways, with flush type handle with 16mm dia round bars and 15 mm dia GI pipe upto 7.5m for protection and connected to earthing test point all as specified or indicated including testing on completion. |
| 101 | Supply and install test and commisioning cassette type air conditioning units of capacity 1.5 TR indoor/outdoor complete with cordless remote control unit twin rotary compressor single phase unit 220 volts to 240 volts 50 HZ inverter type fitted in any height/location including outdoor unit mounting stand complete all as specified and directed. |
| 102 | Supply and fix pre wired powerunit with 20 amps mimi MCB and plug top for AC socket complete all as specified and directed. |
AI Tender Summary
Tender Timeline
Jun 20, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysJul 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender