Drinking Water Supply and Sanitation Government Departments Closing in 3 days TDR #56105654

Tender For Estimate For Repair Of Choked/Damaged Underground Pipeline Of Outlet At Rd 5100M Of Mehngrowal Distributary Of Kandi Canal Stage-2

Issued by Government Departments · Hoshiarpur, Punjab
Tender Value
9.40 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
3 days left
EMD
18800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hoshiarpur → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Estimate For Repair Of Choked/Damaged Underground Pipeline Of Outlet At Rd 5100M Of Mehngrowal Distributary Of Kandi Canal Stage-2

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 02-Jul-2026 corrigendum1702062026 Date 06-Jul-2026
2 07-Jul-2026 corrigendumboq07072026 Other 13-Jul-2026
3 09-Jul-2026 corrigendum1709072026 Date 13-Jul-2026
4 06-Jul-2026 corrigendum3606072026 Date 09-Jul-2026
5 13-Jul-2026 CORRIGENDUM1713072026 Date 16-Jul-2026
6 07-Jul-2026 corrigendumboq07072026 Other 16-Jul-2026
7 07-Jul-2026 corrigendumboq07072026 Other 20-Jul-2026
8 16-Jul-2026 corrigendum1716072026 Date 20-Jul-2026
9 22-Jul-2026 CORRIGENDUM1722072026Q Date 24-Jul-2026
10 07-Jul-2026 corrigendumboq07072026 Other 24-Jul-2026
11 20-Jul-2026 CORRIGENDUM1720072026 Date 22-Jul-2026
12 07-Jul-2026 corrigendumboq07072026 Other 22-Jul-2026
13 30-Jul-2026 CORRIGENDUM1730072026 Date 03-Aug-2026
14 24-Jul-2026 CORRIGENDUM1724072026 Date 27-Jul-2026
15 27-Jul-2026 CORRIGENDUM1727072026 Date 30-Jul-2026
16 03-Aug-2026 CORRIGENDUM1703082026 Date 06-Aug-2026
17 06-Aug-2026 CORRIGENDUM1706082026 Date 10-Aug-2026

BOQ

Name of Work:- ESTIMATE FOR REPAIR OF CHOKED/DAMAGED UNDERGROUND PIPELINE OF OUTLET AT RD 5100M OF MEHNGROWAL DISTRIBUTARY OF KANDI CANAL STAGE-2
Sl. No. Item Description
1Providing & fixing C.I/D.I Flanged end, stem of SS (AIS1410) and Bronze(gunmetal) working parts Sluice ValvesISI marked 14846-2000, including jointing , testing &cost of Nut ,Bolt & insertion sheet, all carriage complete(with the approval of Engineer in-charge). (B) Class PN-1.6 as per ISI (( c)) 150mm i/d Sluice valve flanged
2Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.(b) Size 0.9 m. x 0.9 m.
3Excavation by mechanical means(JCB or Hydraulicexcavator) in trenches for pipe lines with straight or opencutting in streets or open area including dressing sideslevelling of beds of trenches to correct grade, cutting jointholes, refilling consolidation,watering , including the cost of diversion for traffic, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. (a) Earth work upto 1.5 m. Depth for (i) All classes of soil except rocky
4Laying ,fixing & jointing of 140 mm UPVC pipes@ 2.5 kgf pressure as per ISI-4985 (ISI marked with the prior approval of Engineer in charge ) along the tranches and laying the same in trenches to correct alignment and gradient , cutting ,jointing and testing complete as per specifications.
5Laying ,fixing & jointing of 125 mm UPVC pipes@ 2.5 kgf pressure as per ISI-4985 (ISI marked with the prior approval of Engineer in charge ) along the tranches and laying the same in trenches to correct alignment and gradient, cutting ,jointing and testing complete as perspecifications.
6Supply & fixing 140 mm socket 6kg/cm2 including carriage, rehandling , loading, unloading and testing etc complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
7Supply & fixing 125 mm socket 6kg/cm2 including carriage, rehandling , loading, unloading and testing etc complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
8Providing and fixing euqal Tee of 6kg/cm2 pressure as IS4985 Incuding testing comissioning and complete inall respect to the specification of Engineer in charge.For 140mm
9Providing and fixing euqal Tee of 6kg/cm2 pressure as IS4985 Incuding testing comissioning and complete inall respect to the specification of Engineer in charge.For 125 mm
10Providing and fixing Alfa valve as IS 4985 Incudingtesting comissioning and complete in all respect to thespecification of Engineer in charge.For 140mm
11Providing and fixing Alfa valve as IS 4985 Incudingtesting comissioning and complete in all respect to thespecification of Engineer in charge.For 125 mm
12Laying ,fixing & jointing of 160 mm UPVC pipes@ 2.5 kgf pressure as per ISI-4985 (ISI marked with the prior approval of Engineer in charge ) along the tranches and laying the same in trenches to correct alignment and gradient, cutting, jointing and testing complete as perspecifications.
13Supply & fixing 160 mm socket 6kg/cm2 including carriage, rehandling , loading, unloading and testing etc complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
14Supply of 125mm UPVC pipes@ 2.5 kgf pressure asper ISI-4985 (ISI marked with the prior approval of Engineer in chaarge
15Supply of 140 mm UPVC pipes@ 2.5 kgf pressure asper ISI-4985 (ISI marked with the prior approval of Engineer in chaarge
16Supply of 160 mm UPVC pipes@ 2.5 kgf pressure as per ISI-4985 (ISI marked with the prior approval of Engineer in chaarge
17First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth
18Laying ,fixing & jointing of 180 mm UPVC pipes@ 2.5 kgf pressure as per ISI-4985 (ISI marked with the prior approval of Engineer in charge ) along the tranches and laying the same in trenches to correct alignment and gradient, cutting, jointing and testing complete as perspecifications.
19Supply & fixing 180mm socket 6kg/cm2 includingcarriage, rehandling , loading, unloading and testing etccomplete in all respects as per design and P.W.D.specifications and instructions of engineer in charge.
20Providing & fixing 180 mm Dia. Equal Tee (6 kg/cm2pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D.
21Providing & fixing 180 mm Dia. Short OR long Bend (90Degree)(6 kg/cm2 pressure) conforming to IS codes withlatest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
22Supply of 180mm UPVC pipes@ 2.5 kgf pressure asper ISI-4985 (ISI marked with the prior approval of Engineer in chaarge
23Providing & fixing 200 mm Tail end point 6kg with M.S./C.I. flange(6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
24Providing & fixing 160 mm Tail end point 6kg with M.S./C.I. flange(6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge.
25Providing and fixing of Alfa valve of 160 mm dia complete Including all tax and charges
26Providing and fixing of Alfa valve of 180 mm dia complete Including all tax and charges
27Providing & fixing C.I/D.I Flanged end, stem of SS (AIS1410) and Bronze(gunmetal) working parts Sluice ValvesISI marked 14846-2000, including jointing , testing &cost of Nut ,Bolt & insertion sheet, all carriage complete(with the approval of Engineer in-charge). (B) Class PN-1.6 as per ISI (( d)) 200mm i/d Sluice valve flanged
2810mm thick Cement Plaster 1:3
2910mm thick Cement Plaster 1:3 on floors
30Any Other Item (CSR + SP) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56105654
AUTHORITY Government Departments
TENDER VALUE 9.40 Lakhs
LAST DATE 10-08-2026
Authority
Authority Name Water Resources Department
Work Description Tender for Estimate For Repair Of Choked/Damaged Underground Pipeline Of Outlet At Rd 5100M Of Mehngrowal Distributary Of Kandi Canal Stage-2
Basic Detail
Tender No 17/2026-27
Bidding Type Tender
Location
City Hoshiarpur
State Punjab
Key Dates
Publish Date 06 Aug 2026
Submission Date 10 Aug 2026
Open Date 10 Aug 2026
Finance
Tender Value 9.40 Lakhs
Tender Fee 500
EMD 18800
Exemption Available
Document List
BOQ_347319.xls
c1524038-539a-49e4-a2f0-6cc5dd57e8d0.html
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 06, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 06, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 13, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 13, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 09, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 16, 2026
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 16, 2026
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 20, 2026
18:00 IST

Corrigendum-7 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 20, 2026
18:00 IST

Corrigendum-8 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 24, 2026
18:00 IST

Corrigendum-9 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 24, 2026
18:00 IST

Corrigendum-10 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 22, 2026
18:00 IST

Corrigendum-11 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 22, 2026
18:00 IST

Corrigendum-12 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 03, 2026
18:00 IST

Corrigendum-13 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 27, 2026
18:00 IST

Corrigendum-14 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 30, 2026
18:00 IST

Corrigendum-15 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 06, 2026
18:00 IST

Corrigendum-16 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 10, 2026
18:00 IST

Corrigendum-17 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Aug 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_347319.xls

html

c1524038-539a-49e4-a2f0-6cc5dd57e8d0.html

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders