| 1 | SUPPLY- GIS : 400kV, 63KA FOR 1S, GAS INSULATED SWITCHGEAR (GIS) AS PER TS (for item sl. No. 1.01-1.14):420KV, 5000A, 63 KA, SF6 GIS BUS BAR MODULE AS PER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 2 | 420KV, 3150A, 63 KA, SF6 GIS ICT FEEDER BAY MODULE AS PER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 3 | 420KV, 3150A, 63 KA, SF6 GIS BUS REACTOR BAY MODULE AS PERSECTION-PROJECT, TECHNICAL SPECIFICATION |
| 4 | 420 KV, 3150A, 63 KA, SF6 GIS LINE FEEDER BAY MODULE (WITHOUT PIR) AS PER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 5 | 420KV, 3150A, 63 KA, SF6 GIS TIE BAY MODULE (WITHOUT PIR) AS PER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 6 | 420KV, 3150A, 63KA SF6 TO AIR BUSHING INCLUDING SUPPORT STRUCTURE |
| 7 | CONTROLLED SWITCHING DEVICE FOR 420 KV, 3-PH CIRCUIT BREAKER |
| 8 | 420KV, 3000A, 63KA, SINGLE PHASE, SF6 GAS INSULATED BUS DUCT (GIB) OUTSIDE GIS HALL ALONG WITH ASSOCIATED SUPPORT STRUCTURE, ETC. AS PER TECHNICAL SPECIFICATION |
| 9 | 420KV, 4000 A, 63 KA, SF6 GIS BUS SECTIONALISER MODULE AS PER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 10 | 420KV, 3150 A, 63 KA, SF6 GIS AUXILIARY BUS MODULE FOR SPARE TRANSFORMER AS PER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 11 | 420KV, 3150 A, 63 KA, SF6 GIS COUPLING TRANSFORMER FEEDER BAY MODULE AS PER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 12 | 420KV, 3150 A, 63 KA, SF6 GIS AUXILIARY BUS MODULE FOR SPARE COUPLING TRANSFORMER AS PER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 13 | 420 KV, 3150 A, 63 KA, SF6 GIS LINE FEEDER BAY MODULE (WITH PIR) AS PER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 14 | 420KV, 3150 A, 63 KA, SF6 GIS TIE BAYMODULE (WITH PIR) AS PER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 15 | SUPPLY- GIS : 400KV, SPECIAL TOOLS AND TESTING & MAINTENANCE EQUIPMENTS AS PER TS (For item sls. No. 2.01-2.04):PORTABLE PARTIAL DISCHARGE MEASUREMENT TEST KITWITH ALL NECESSARY ACCESSORIES,INDUSTRIAL GRADE LAPTOP AND LICENSEDSOFTWARE AS PER TECHNICALSPECIFICATION. |
| 16 | SF6 GAS ANALYZER |
| 17 | SF6 GAS LEAKAGE DETECTOR |
| 18 | SF6 GAS PROCESSING UNIT FOR 400KV GIS STATION |
| 19 | SPARES- GIS : 400kV, 63KA FOR 1S, MANDATORY SPARES AS PER TS (For item sl. No. 3.01-3.51):400KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE |
| 20 | SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-400KV GIS |
| 21 | COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-400KV GIS |
| 22 | RUBBER GASKETS, ’O' RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-400KV GIS |
| 23 | 400KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5 % OF TOTALWEIGHT) |
| 24 | CONTROL VALVES FOR SF6 GAS OF EACH TYPE-400KV GIS |
| 25 | 400KV GIS-SF6 GAS (5 % OF TOTAL GAS QUANTITY) |
| 26 | LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES IN CLOSE OR OPEN POSITION IN CASEOF REMOVAL OF THE DRIVING MECHANISM-400KV GIS |
| 27 | UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 420KV GIS |
| 28 | 400KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS |
| 29 | 400KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)ALONG WITH ASSOCIATED CONTACTS AND SHIELDS |
| 30 | 400KV GIS- 3150A SF6 TO AIR BUSHING COMPLETE IN ALL RESPECT |
| 31 | LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES,LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-400KV GIS |
| 32 | 400KV GIS-ONE POLE OF 3150A CIRCUIT BREAKER WITHOUT PIR WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETEIN ALL RESPECT |
| 33 | TRIP COIL ASSEMBLY WITH RESISTOR FOR420KV GIS CIRCUIT BREAKER (AS APPLICABLE) |
| 34 | CLOSING COIL ASSEMBLY WITH RESISTOR FOR420KV GIS CIRCUIT BREAKER (AS APPLICABLE) |
| 35 | RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (AS APPLICABLE) OF EACH TYPE FOR 400KV GIS CIRCUIT BREAKER |
| 36 | AUXILIARY SWITCH ASSEMBLY OF EACH TYPE FOR 420KV GIS CIRCUIT BREAKER |
| 37 | 400KV GIS CIRCUIT BREAKER-OPERATION COUNTER |
| 38 | 400KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVEMOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) |
| 39 | HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-400KV GIS CIRCUIT BREKAER |
| 40 | 400KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE) |
| 41 | 400KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE) |
| 42 | VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER |
| 43 | PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER |
| 44 | PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-400KV GIS CIRCUIT BREKAER |
| 45 | PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER |
| 46 | 400KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY)(FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) |
| 47 | PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-400KV GIS CIRCUIT BREKAER |
| 48 | 400KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISMINCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) |
| 49 | 400KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) |
| 50 | PRESSURE SWITCHES OF EACH TYPE FOR420KV GIS CIRCUIT BREAKER (FOR HYDRAULIC-SPRING OPERATED MECHANISM, IF APPLICABLE) |
| 51 | PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-400KV GIS CIRCUIT BREKAER |
| 52 | 400KV GIS- SINGLE PHASE OF 3150A DISCONNECTOR SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISMAND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT |
| 53 | 400KV GIS- SINGLE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.,COMPLETE IN ALL RESPECT |
| 54 | 400KV GIS - SINGLE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT |
| 55 | OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS DISCONNECTORSWITCH |
| 56 | OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS MAINTENANCE EARTHSWITCH |
| 57 | OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 400KV GIS FAST EARTHINGSWITCH |
| 58 | LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-400KV GIS |
| 59 | LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-400KV GIS |
| 60 | LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-400KV GIS |
| 61 | DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH |
| 62 | DRIVE MECHANISM FOR 400KV GIS MAINTENANCE EARTH SWITCH |
| 63 | DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH |
| 64 | MOTOR FOR DRIVE MECHANISM FOR 400KV GIS DISCONNECTOR SWITCH |
| 65 | MOTOR FOR DRIVE MECHANISM FOR 400KVGIS MAINTENANCE EARTH SWITCH |
| 66 | MOTOR FOR DRIVE MECHANISM FOR 400KV GIS FAST EARTHING SWITCH |
| 67 | 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (3 CORES, TYPE-CTA)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT |
| 68 | 400KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (2 CORES, TYPE-CTB)WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALLRESPECT |
| 69 | 400KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALLRESPECT |
| 70 | SUPPLY- GIS : 400kV, 63kA FOR 1S, REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS(Unit Prices of Individual Equipment included here or in manadatory spares are required for any Addition/Deletion of Equipment andreplacement of damaged items. Vendor to ensure that the unit prices have a logical relationship with prices of assemblies in main items.Quoting for unit prices is mandatory and shall be considered for evaluation) (For item sl. No. 4.01-4.06):SUPPLY- GIS : 400kV, SINGLE PHASE BUS BAR |
| 71 | SUPPLY- GIS : 400kV, GIS METALLIC ENCLOSURE |
| 72 | SUPPLY- GIS : 400kV, EXPANSION BELLOWS/ JOINTS |
| 73 | SUPPLY- GIS : 400kV, TEE BEND |
| 74 | SUPPLY- GIS : 400kV, ANGLE BEND |
| 75 | SUPPLY- GIS : 400kV, L-BEND |
| 76 | SERVICES- GIS : 400kV, 63kA FOR 1S, GAS INSULATED SWITCHGEAR (GIS) AS PER TS (For item sl. No. 5.01-5.09):SERVICES- GIS : 400kV, SUPERVISION OF ERECTION OF GIS |
| 77 | SERVICES- GIS : 400kV, SUPERVISION OF ERECTION OF GAS INSULATED BUS DUCT |
| 78 | SERVICES- GIS : 400kV, SUPERVISION OF ERECTION OF SF6 TO AIR BUSHING |
| 79 | SERVICES- GIS : 400kV, TESTING & COMMISSIONING OF GIS |
| 80 | SERVICES- GIS : 400kV, TESTING & COMMISSIONING OF GAS INSULATED BUS DUCT |
| 81 | SERVICES- GIS : 400kV, TESTING & COMMISSIONING OF SF6 TO AIR BUSHING |
| 82 | SERVICES- ETC OF CONTROLLED SWITCHING DEVICE FOR 420 KV, 3-PH CIRCUIT BREAKER |
| 83 | SERVICES- GIS : 400kV, FINAL SUCCESSFUL HV/ POWER FREQUENCY TESTING OF GIS INCLUDING ARRANGING OF HV TEST KIT ALONG WITH OPERATOR |
| 84 | SERVICES- GIS : INSULATION CO-ORDINATION STUDIES FOR GIS SYSTEM |
| 85 | SERVICES- GIS : 400kV, 63kA FOR 1S, REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICESSERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES(Unit Prices of Individual services included here are required for any Addition/Deletion of Equipment and replacement of damaged items.Vendor to ensure that the unit prices have a logical relationship with prices of assemblies in main items. Quoting for unit prices ismandatory and shall be considered for evaluation) (For item sl. No. 6.01-6.05):SERVICES- GIS : 400kV, REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR SUPERVISION OF ERECTION OF GIS |
| 86 | SERVICES- GIS : 400kV, REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR TESTING & COMMISSIONING OF GIS |
| 87 | SERVICES- GIS : 400kV, DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GIS ERECTION SUPERVISION TEAM |
| 88 | SERVICES- GIS : 400kV, DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GIS TESTING & COMMISSIONING TEAM |
| 89 | SERVICES- GIS : 400kV, DEMOBILIZATION & REMOBILIZATION CHARGES OF HV TEST KIT ALONG WITH OPERATOR |
| 90 | SUPPLY- GIS : 220kV, 50kA FOR 1S, GAS INSULATED SWITCHGEAR (GIS) AS PER TS (for item sl. No. 1.01-1.08):245KV, 3000A, 50KA, SF6 GIS BUS BAR MODULE AS PER SECTION-PROJECT,TECHNICAL SPECIFICATION |
| 91 | 245KV,3000A, 50KA FOR 1 SECOND, SF6 GAS-INSULATED METAL ENCLOSED BUS SECTION BAY MODULE AS PER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 92 | 245KV, 3000A, 50KA, SF6 GIS BUS COUPLER BAY MODULE AS PER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 93 | 245KV, 3000A, 50KA, 3 SINGLE PHASE/ 3 PHASE, SF6 GAS INSULATED BUS DUCT (GIB) OUTSIDE GIS HALL ALONG WITH ASSOCIATED SUPPORT STRUCTURE(QUANTITY MENTIONED HERE IS FOR 3 PHASE TYPE) |
| 94 | 245KV, 1600A, 50 KA, SF6 GIS ICT FEEDERBAY MODULE AS PER SECTION-PROJECT,TECHNICAL SPECIFICATION |
| 95 | 245KV, 1600A, 50 KA, SF6 GIS LINE FEEDER BAY MODULE AS PER SECTION-PROJECT, TECHNICAL SPECIFICATION |
| 96 | 245KV, 1600A, 50KA, 3 SINGLE PHASE/ 3PHASE, SF6 GAS INSULATED BUS DUCT (GIB) OUTSIDE GIS HALL ALONG WITH ASSOCIATED SUPPORT STRUCTURE(QUANTITY MENTIONEDHERE IS FOR 3 PHASE TYPE) |
| 97 | 245KV, 1600A, 50KA SINGLE PHASE SF6 TO AIR BUSHING |
| 98 | SPARES- GIS : 220kV, 50kA FOR 1S, MANDATORY SPARES AS PER TS (for ietm sl. No. 2.01-2.52):220KV GIS-SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE |
| 99 | COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTING GAS HANDLING PLANT OF EACH TYPE-220KV GIS |
| 100 | SF6 PRESSURE GAUGE CUM SWITCH/ DENSITY MONITORS AND PRESSURE SWITCH AS APPLICABLE, OF EACH TYPE-220KV GIS |
| 101 | RUBBER GASKETS, ’O' RINGS AND SEALS FOR SF6 GAS FOR GIS ENCLOSURE OF EACH TYPE-220KV GIS |
| 102 | 220KV GIS-MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (5% OF TOTAL WEIGHT) |
| 103 | CONTROL VALVES FOR SF6 GAS OF EACH TYPE-220KV GIS |
| 104 | 220KV GIS-SF6 GAS (5% OF TOTAL GAS QUANTITY) |
| 105 | LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS) AND EARTHING/ FAST EARTHING SWITCHES (AS APPLICABLE) IN CLOSE OR OPEN POSITION IN CASEOF REMOVAL OF THE DRIVING MECHANISM-220KV GIS |
| 106 | UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 245KV GIS |
| 107 | 220KV GIS-SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITH METAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS |
| 108 | 220KV GIS-GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.) ALONG WITH ASSOCIATED CONTACTS AND SHIELDS |
| 109 | 245KV,2000A, 50KA SINGLE PHASE SF6 TO AIR BUSHING |
| 110 | LCC SPARES - AUX. RELAYS, CONTACTORS, PUSH BUTTONS, SWITCHES, LAMPS, ANNUNCIATION WINDOWS, MCB, FUSES, TIMERS, TERMINAL BLOCKS ETC. OFEACH TYPE & RATING-220KV GIS |
| 111 | 220KV GIS-ONE POLE OF 2000A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT |
| 112 | 220KV GIS-ONE POLE OF 3500A CIRCUIT BREAKER WITH INTERRUPTER, MAINCIRCUIT, ENCLOSURE AND OPERATING MECHANISM COMPLETE IN ALL RESPECT |
| 113 | TRIP COIL ASSEMBLY WITH RESISTOR FOR 245KV GIS CIRCUIT BREAKER (ASAPPLICABLE) |
| 114 | CLOSING COIL ASSEMBLY WITH RESISTOR FOR 245KV GIS CIRCUIT BREAKER (AS APPLICABLE) |
| 115 | RELAYS, POWER CONTACTORS, PUSH BUTTONS, TIMERS & MCBS ETC. (AS APPLICABLE) OF EACH TYPE FOR 220KV GIS CIRCUIT BREAKER |
| 116 | AUXILIARY SWITCH ASSEMBLY OF EACH TYPE FOR 245KV GIS CIRCUIT BREAKER |
| 117 | 220KV GIS CIRCUIT BREAKER-OPERATION COUNTER |
| 118 | 220KV GIS CIRCUIT BREAKER-HYDRAULIC OPERATING MECHANISM WITH DRIVE MOTOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) |
| 119 | HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER |
| 120 | 220KV GIS CIRCUIT BREAKER- HOSE PIPE OF EACH TYPE (AS APPLICABLE) (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) |
| 121 | 220KV GIS CIRCUIT BREAKER - N2 ACCUMULATOR (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) |
| 122 | VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER |
| 123 | PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER |
| 124 | PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER |
| 125 | PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER |
| 126 | 220KV GIS CIRCUIT BREAKER-HYDRAULIC OIL (5% OF TOTAL OIL QUANTITY) (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE) |
| 127 | PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER |
| 128 | 220KV GIS CIRCUIT BREAKER-COMPLETE SPRING OPERATING MECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE) |
| 129 | 220KV GIS CIRCUIT BREAKER- COMPLETE HYDRAULIC-SPRING OPERATING MECHANISM INCLUDING CHARGING MECHANISM ETC. (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE) |
| 130 | PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC-SPRING OPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREAKER |
| 131 | PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRING OPERATED MECHANISM, IF APPLICABLE)-220KV GIS CIRCUIT BREKAER |
| 132 | 220KV GIS- THREE PHASE OF 2000A DISCONNECTOR SWITCH INCLUDING MAIN CIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE IN ALL RESPECT |
| 133 | 220KV GIS- THREE PHASE OF 3500A DISCONNECTOR SWITCH INCLUDING MAIN CIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE IN ALL RESPECT |
| 134 | 220KV GIS- THREE PHASE MAINTENANCE EARTHING SWITCH INCLUDING MAIN CIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE IN ALL RESPECT |
| 135 | 220KV GIS - THREE PHASE FAST EARTHING SWITCH INCLUDING MAIN CIRCUIT,ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC., COMPLETE INALL RESPECT |
| 136 | OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKING COILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS, RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONEOF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS DISCONNECTORSWITCH |
| 137 | OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKING COILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS, RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONE OF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS MAINTENANCEEARTH SWITCH |
| 138 | OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKING COILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS, RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. (AS APPLICABLE) ONE OF EACH TYPE FOR ONE COMPLETE MOM BOX FOR 220KV GIS FAST EARTHINGSWITCH |
| 139 | LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR DISCONNECTOR-220KV GIS |
| 140 | LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR MAINTENANCE EARTHING SWITCH-220KV GIS |
| 141 | LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FAST EARTHING SWITCH (IF APPLICABLE)-220KV GIS |
| 142 | DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH |
| 143 | DRIVE MECHANISM FOR 220KV GIS MAINTENANCE EARTH SWITCH |
| 144 | DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH |
| 145 | MOTOR FOR DRIVE MECHANISM FOR 220KV GIS DISCONNECTOR SWITCH |
| 146 | MOTOR FOR DRIVE MECHANISM FOR 220KV GIS MAINTENANCE EARTH SWITCH |
| 147 | MOTOR FOR DRIVE MECHANISM FOR 220KV GIS FAST EARTHING SWITCH |
| 148 | 220KV GIS- SINGLE PHASE VT WITH ASSOCIATED ENCLOSURE COMPLETE IN ALL RESPECT |
| 149 | 220KV GIS- SINGLE PHASE OF CURRENT TRANSFORMER (5 CORES) WITH ASSOCIATED ENCLOSURE AND PRIMARY CONDUCTOR COMPLETE IN ALL RESPECT |
| 150 | SUPPLY- GIS : 220kV, 50kA FOR 1S, REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SUPPLY ITEMS (Unit Prices of Individual Equipment included here or in manadatory spares are required for any Addition/Deletion of Equipment and replacement of damaged items. Vendor to ensure that the unit prices have a logical relationship with prices of assemblies in main items.Quoting for unit prices is mandatory and shall be considered for evaluation) (For item sl. No. 3.01-3.06): SUPPLY- GIS : 245kV, SINGLE PHASE BUS BAR |
| 151 | SUPPLY- GIS : 245kV, GIS METALLIC ENCLOSURE |
| 152 | SUPPLY- GIS : 245kV, EXPANSION BELLOWS/ JOINTS |
| 153 | SUPPLY- GIS : 245kV, TEE BEND |
| 154 | SUPPLY- GIS : 245kV, ANGLE BEND |
| 155 | SUPPLY- GIS : 245kV, L-BEND |
| 156 | SERVICES- GIS : 220kV, 50kA FOR 1S, GAS INSULATED SWITCHGEAR (GIS) AS PER TS (For item sl. No. 4.01-4.08):SERVICES- GIS : 245kV, SUPERVISION OF ERECTION OF GIS |
| 157 | SERVICES- GIS : 245kV, SUPERVISION OF ERECTION OF GAS INSULATED BUS DUCT (QUANTITY MENTIONED HERE IS FOR 3 PHASE TYPE) |
| 158 | SERVICES- GIS : 245kV, SUPERVISION OF ERECTION OF SF6 TO AIR BUSHING |
| 159 | SERVICES- GIS : 245kV, TESTING & COMMISSIONING OF GIS |
| 160 | SERVICES- GIS : 245kV, TESTING & COMMISSIONING OF GAS INSULATED BUS DUCT (QUANTITY MENTIONED HERE IS FOR 3 PHASE TYPE) |
| 161 | SERVICES- GIS : 245kV, TESTING & COMMISSIONING OF SF6 TO AIR BUSHING |
| 162 | SERVICES- GIS : 245kV, FINAL SUCCESSFUL HV/ POWER FREQUENCY TESTING OF GIS INCLUDING ARRANGING OF HV TEST KIT ALONG WITH OPERATOR |
| 163 | SERVICES- GIS : INSULATION CO-ORDINATION STUDIES FOR GIS SYSTEM |
| 164 | SERVICES- GIS : 220kV, 50kA FOR 1S, REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICESSERVICES- GIS : REFERENCE UNIT PRICE FOR ADDITION / DELETION OF SERVICES(Unit Prices of Individual services included here are required for any Addition/Deletion of Equipment and replacement of damaged items. Vendor to ensure that the unit prices have a logical relationship with prices of assemblies in main items. Quoting for unit prices is mandatory and shall be considered for evaluation) (For item sl. No. 5.01-5.05):SERVICES- GIS : 245kV, REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR SUPERVISION OF ERECTION OF GIS |
| 165 | SERVICES- GIS : 245kV, REF. UNIT PRICE OF GIS INDIVIDUAL ITEM/ EQUIPMENT - SERVICES FOR TESTING & COMMISSIONING OF GIS |
| 166 | SERVICES- GIS : 245kV, DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GIS ERECTION SUPERVISION TEAM |
| 167 | SERVICES- GIS : 245kV, DEMOBILIZATION AND REMOBILIZATION CHARGES FOR GIS TESTING & COMMISSIONING TEAM |
| 168 | SERVICES- GIS : 245kV, DEMOBILIZATION & REMOBILIZATION CHARGES OF HV TEST KIT ALONG WITH OPERATOR Please Enable Macros to View BoQ information |